Agilent E7574ADatacom 4-Link Interface Module
Reference Manual
7/30/2019 dcomref
2/36
Agilent Technologies5070 Centennial Boulevard
Colorado Springs, CO 80919-2497 USA
Copyright 2002
Agilent Technologies, Inc.
All rights reserved.
Reproduction, adaptation,
or translation without prior
written permission is
prohibited, except as
allowed under the
copyright laws.
Part No. 37907-90232
First edition, January 2002
Printed in U.K.
Trademarks
Microsoft is a U.S.
registered trademark of
Microsoft Corporation.
Windows and
MS Windows are U.S.
registered trademarks of
Microsoft Corporation.
Product Support
Call your local Agilent
Technologies
representative, or:
Tel: 1-800-452-4844
Fax: 303-754-4802
or call your local Agilent
Sales and Service Office.
DocumentationWarranty
The information contained
in this document is subject
to change without notice.
Agilent Technologies
makes no warranty of any
kind with regard to this
material, including, but
not limited to, the implied
warranties or
merchantability and fitnessfor a particular purpose.
Agilent Technologies shall
not be liable for errors
contained herein or for
incidental or consequential
damages in connection
with the furnishing,
performance, or use of thismaterial.
SAFETY
Warning
Warning denotes a
hazard. It calls attention
to a procedure, which if
not correctly performed
or adhered to could
result in injury or loss of
life. Do not proceed
beyond a warning note
until the indicatedconditions are fully
understood and met.
Caution
Caution denotes a hazard.
It calls attention to a
procedure, which if not
correctly performed oradhered to could result in
damage to or destruction
of the instrument. Do not
proceed beyond a caution
note until the indicated
conditions are fully
understood and met.
For details of safety, see
Safety Symbols, page 28.
7/30/2019 dcomref
3/36
Agilent E7574ADatacom 4-Link Interface Module
Reference Manual
7/30/2019 dcomref
4/36
2
The interface module provides the physical connection between the Signaling
Advisor and the network you are testing. The interface module extracts the signaling
information from up to four duplex links and adds a timestamp to the captured data
before routing it to the Signaling Advisor for storage and analysis.
Sources of information about the Signaling Advisor
The documentation supplied is listed below:
Mainframe Reference Manual - This manual describes the Signaling Advisor
hardware. It also covers the connection and configuration of accessories via PC
Cards in the PCMCIA slots.
Users Manual - This manual tells you how to use the Signaling Advisor to monitor
and emulate signaling data, view and interpret the results.
Software Recovery Guide - This manual provides detailed instructions for rein-
stalling Windows and the Signaling Advisor System Software. (Note: Your instru-
ment is shipped with all software installed.)
Interface Module Reference Manuals - Each interface module is provided with a
manual which tells you how to install and verify the operation of the module.
Unpacking and Installation Card - Identifies the items you will typically receive
with your instrument. It also shows you how to proceed when you first receive your
instrument.
Quick Start and Quick Reference - A summary of useful operating information.
Registration and Initial Setup for the Signaling Advisor - Contains the prelimi-
nary procedures you need to follow when you first receive your instrument.
Signaling Advisor Undercradle Installation Manual (Optional) - This manualcontains installation instructions on how to connect/disconnect the undercradle
to/from Signaling Advisor.
On-Line Help - The help comprises three parts: on-line help, context sensitive help,
and copies of the manuals supplied with the instrument, support information, con-
figuration information and frequently asked questions. Microsoft Windows on-line
help is also available.
Web Site - http://onenetworks.comms.agilent.com/
Introduction
7/30/2019 dcomref
5/36
3
List of Contents
List of Contents
Installing an Interface Module ............................................................................. 5
Connecting Interface Modules to Bearers............................................................ 7
Cabling Information .......................................................................................... 8
Connecting to a V35, RS-449 or RS-232 Network Monitor Point ................... 11
Connecting for End Emulation.......................................................................... 12
V.35 J4201A Cable Interconnections................................................................ 13
RS-449 J4202A Cable Interconnections ........................................................... 16RS-232 J4203A Cable Interconnections ........................................................... 19
Verifying Correct Operation ................................................................................ 22
Description ........................................................................................................ 22
Verification Prerequisites .................................................................................. 22
Procedure........................................................................................................... 23
Product Identification ....................................................................................... 25
Build Status ....................................................................................................... 25
Statement of Compliance ..................................................................................... 26Electromagnetic Compatibility (EMC) Information ......................................... 26
Safety Information............................................................................................. 26
Noise Declaration (German) ............................................................................. 26
Declaration of Conformity ................................................................................... 27
Safety Symbols..................................................................................................... 28
ESD Precautions................................................................................................... 29
Cleaning the Product............................................................................................ 29
Calibration Cycle.................................................................................................. 30Operating Environment ....................................................................................... 30
Storage and Shipment........................................................................................... 31
Returning for Service ........................................................................................ 31
Weight and Dimensions .................................................................................... 32
Web Site for Additional Product Information...................................................... 32
7/30/2019 dcomref
6/36
4
7/30/2019 dcomref
7/36
5
Installation and General Information
Installing an Interface Module
Installing an Interface Module
You can have up to two modules installed in your Signaling Advisor. However, the
number of modules can be extended by up to two if you have an undercradle fitted. The
modules operate in either slot. If only one module is fitted to your Signaling Advisor
then a Filler Panel must be fitted to the empty slot.
WAR NI NG If this product is not used as specified, the protection provided by the product
could be impaired. This product must be used in a normal condition only (in
which all means for protection are intact).
CAUTION To prevent possible system errors, you must turn off the power to the Signaling
Advisor before installing or removing a module.
To install a module (or Filler Panel) into a Signaling Advisor:
1 Ensure the Module Release Latch is in the unlocked position.
2 Fit and slide the module (or Filler Panel) into the opening on the side of the
instrument, see the following figure.
3 Push the module firmly into place until it is seated (the Module Release Latch
automatically moves to the locked position). If you are fitting a Filler Panel, you will
need to manually move the Module Release Latch to its locked position.
INTERFACE MODULE
LATCH
7/30/2019 dcomref
8/36
6
Installation and General Information
Installing an Interface Module
To remove an interface module (or Filler Panel) from a Signaling Advisor:
1 Depress the left end of the Module Release Latch (labeled PUSH TO UNLOCK)
then slide the latch to the left end (unlocked position).
2 Pull the module (or Filler Panel) out of the module.
To install an interface module into an undercradle:
1 Switch off the power to the instrument.
2 Fit and slide the module into the opening of the undercradle.
3 Push it into place until it is seated, see the figure below.
To remove an interface module from an undercradle:
1 Slide the Module Release Latch towards the left.
2 Pull the module out of the undercradle.
For more information, refer to the Installation Manual that is shipped with theundercradle.
Pull knob goes toward
outside of Signaling Advisor
UP
7/30/2019 dcomref
9/36
7
Installation and General Information
Connecting Interface Modules to Bearers
Connecting Interface Modules to Bearers
Connections to the network are made with the two connectors on the interface module.
Each connector provides two V.35/RS-449/RS-232 full duplex links in Monitor mode.
In Emulate mode, the interface module can transmit V.35/RS-449/RS-232 signals.
CAUTION The ports on this module go low impedance when the Signaling Advisor is switched
off. If any port is connected to an unprotected monitor point, disconnect the cable
from the Signaling Advisor before powering off, otherwise the low impedance state
could adversely affect the network.
CAUTION When connecting or disconnecting, ensure that you are grounded or, make contact
with the metal surface of the mainframe with your free hand to bring you, the module,and the Signaling Advisor to the same static potential. Modules remain susceptible
to ESD damage while the module is installed in the Signaling Advisor. Additional
ESD precautions are required when servicing, see page 29.
NOTE The Bearer settings will be disabled when there is no adapter cable fitted, or when an
invalid or unsupported cable is fitted, or when the loopback connector is fitted.
Bearers 1 and 2 Bearers 3 and 4
7/30/2019 dcomref
10/36
8
Installation and General Information
Connecting Interface Modules to Bearers
Cabling Information
Description Length Part No.
V.35 Dual Link cable. 2 m J4201A
For V.35 interconnections, see page 13.
RS-449 Dual Link cable. 2 m J4202A
For RS-449 interconnections, see page 16.
7/30/2019 dcomref
11/36
9
Installation and General Information
Connecting Interface Modules to Bearers
RS-232 Dual Link cable. 2 m J4203A
For RS-232 interconnections, see page 19.
Description Length Part No.
7/30/2019 dcomref
12/36
10
Installation and General Information
Connecting Interface Modules to Bearers
Self Test Loopback connector. 2 m J4204A
SCSI-1 to SCSI-2 cable. 2 m J4208A
All pins are connected with one to one mapping.
Description Length Part No.
Interconnections
Pin Pin
1 25
2 24
3 23
4 22
5 21
12 37
14 39
26 50
27 49
28 48
29 47
30 46
All other pins not used.
7/30/2019 dcomref
13/36
11
Installation and General Information
Connecting Interface Modules to Bearers
Connecting to a V35, RS-449 or RS-232 Network Monitor Point
The module is automatically configured for a V.35, RS-449 or RS-232 network when
you switch on the Signaling Advisor and the appropriate V.35, RS-449 or RS-232
adapter cable is fitted to the module via the J4208A cable. The adapter cable currently
being used and the other module settings are displayed in the Signaling Advisors
Bearer view.
CAUTION The ports on this module go low impedance when the Signaling Advisor is switched
off. If any port is connected to an unprotected monitor point, disconnect the cablefrom the Signaling Advisor before powering off, otherwise the low impedance state
could adversely affect the network.
For more information on configuring the Signaling Advisors V.35/RS-449/RS-232
bearer settings in Monitor mode, refer to the instruments On-Line Help.
The following diagram shows how you make a bridged connection on a duplex link
when a monitor point is available.
The maximum combined length for the link plus drop cable is 15 m (RS-232), 1200 m
(RS-449) and 100 m (V.35).
7/30/2019 dcomref
14/36
12
Installation and General Information
Connecting Interface Modules to Bearers
Connecting for End Emulation
In Emulate mode, you can send and receive messages to/from another piece of
Network Equipment. The Signaling Advisor terminates the Receive side of the Bearer
and generates V.35/RS-449/RS-232 compatible signals on the Transmit side. Maximum
cable length depends on cable quality and will typically be >15 m (RS-232), >1200 m
(RS-449) and >100 m (V.35)
For more information on configuring the Signaling Advisors V.35/RS-449/RS-232
bearer settings in Emulate mode, refer to the instruments On-Line Help.
7/30/2019 dcomref
15/36
13
Installation and General Information
Connecting Interface Modules to Bearers
V.35 J4201A Cable Interconnections
The pin assignment for V.35 connectors (J1, P1 and J2, P2) is shown in the following
table:
Pin Circuit Signal Name Mnemonic
Direction
DCE
Direction
DTE
A AA Protective Ground Shield
B AB Signal Ground GND
C CA Request to Send Input Output
D CB Clear to Send Output Input
E CC Data Set Ready Output Input
F
H CD Data Terminal Ready
J
K
R RD(A) Received Data RXD-A Output Input
T RD(B) Received Data RXD-B Output Input
V SCR(A) Serial Clock Receive RXC-A Output Input
X SCR(B) Serial Clock Receive RXC-B Output Input
P SD(A) Send Data TXD-A Input Output
S SD(B) Send Data TXD-B Input Output
U SCTE(A) Serial Clock Transmit
External DTE Source
XTC-A Input Output
W SCTE(B) Serial Clock Transmit
External DTE Source
XTC-B Input Output
Y SCT(A) Serial Clock Transmit
DCE Source
TXC-A Output Input
AA SCT(B) Serial Clock Transmit
DCE Source
TXC-B Output Input
BB
Z
EE
CC
7/30/2019 dcomref
16/36
14
Installation and General Information
Connecting Interface Modules to Bearers
The V.35 J4201A Dual Link cable pin assignment is shown below:
7/30/2019 dcomref
17/36
15
Installation and General Information
Connecting Interface Modules to Bearers
The V.35 Y Dual Link cable pin assignment is shown below:
7/30/2019 dcomref
18/36
16
Installation and General Information
Connecting Interface Modules to Bearers
RS-449 J4202A Cable Interconnections
The pin assignment for RS-449 connectors (J1, P1 and J2, P2) is shown in the
following table:
Pin Circuit Signal Name Mnemonic
Direction
DCE
Direction
DTE
1 Shield Ground Shield
2 +5 V Power
3 +12 V Power
4 SD(A) Send Data TXD-A Input Output
5 ST(A) Send Timing (DCE source) TXC-A Output Input
6 RD(A) Receive Data RXD-A Output Input
7 RS(A) Request to Send RS-A Input Output
8 RT(A) Receive Timing RXC-A Output Input
9 CS(A) Clear to Send CS-A Output Input
11 DM(A) Data Mode DM-A Output Input
12 TR(A) Terminal Ready TR-A Input Output
17 TT(A) Terminal Timing (DTE source) XTC-A Input Output
19 SG Signal Ground
20 Ground for power
21 -12 V Power
22 SD(B) Send Data TXD-B Input Output
23 ST(B) Send Timing (DCE source) TXC-B Output Input
24 RD(B) Receive Data RXD-B Output Input
25 RS(B) Request to Send RS-B Input Output
26 RT(B) Receive Timing RXC-B Output Input
27 CS(B) Clear to Send CS-B Output Input
29 DM(B) Data Mode DM-B Output Input
30 TR(B) Terminal Ready TR-B Input Output
35 TT(B) Terminal Timing (DTE source) XTC-B Input Output
7/30/2019 dcomref
19/36
17
Installation and General Information
Connecting Interface Modules to Bearers
The RS-449 J4202A Dual Link cable pin assignment is shown below:
7/30/2019 dcomref
20/36
18
Installation and General Information
Connecting Interface Modules to Bearers
The RS-449 Y Dual Link cable pin assignment is shown below:
7/30/2019 dcomref
21/36
19
Installation and General Information
Connecting Interface Modules to Bearers
RS-232 J4203A Cable Interconnections
The pin assignment for RS-232 connectors (J1, P1 and J2, P2) is shown in the
following table:
Pin EIA CCITT Signal Name Mnemonic
Direction
DCE
Direction
DTE
1 AA - Protective Ground Shield
2 BA 103 Transmitted Data TXD Output Input
15 DB 114 Transmit Clock
(DCE source)
TXC Input Output
7 AB 102 Signal Ground GND Input Output
3 BB 104 Received Data RXD Input Output
17 DD 115 Receive Clock
(DCE source)
RXC
24 DA 113 Transmit Clock
(DTE source)
XTC Output Input
7/30/2019 dcomref
22/36
20
Installation and General Information
Connecting Interface Modules to Bearers
The RS-232 J4203A Dual Link cable pin assignment is shown below:
I ll i d G l I f i
7/30/2019 dcomref
23/36
21
Installation and General Information
Connecting Interface Modules to Bearers
The RS-232 Y Dual Link cable pin assignment is shown below:
Installation and General Information
7/30/2019 dcomref
24/36
22
Installation and General Information
Verifying Correct Operation
Verifying Correct Operation
Description
You verify correct operation in Post Capture mode, by selecting All Tests from the
Signaling Advisors built-in Self Test function. When you select All Tests, the
program automatically detects which interface module(s) are housed in the Signaling
Advisor, it then selects and runs the appropriate self tests. It takes approximately 15
minutes to verify each interface module. The default settings are used which means
tests will continue to completion (even if an error is detected), and all results (Pass or
Fail) will be logged to disk.
For a detailed description of Self Test, refer to the instruments On-Line Help.
CAUTION To prevent network disruptions, ensure the Signaling Advisor is disconnected from
your network before you run Self Tests.
Verification Prerequisites
During Self Test you will be prompted to fit external loopback cables.
To minimize verification time ensure that you have following cables available before
you start the Self Test:
Self Test Loopback connector, part number Agilent J4204A.
Clock loopback cable (connects to the Signaling Advisor CLOCK/TRIG IN and
OUT ports), part number Agilent 8120-8820.
Telephone handset (this is an optional connection), part number Agilent 15722A.
Installation and General Information
7/30/2019 dcomref
25/36
23
Installation and General Information
Verifying Correct Operation
Procedure
1 Double-click the Signaling Advisor icon in the desktop.
2 Click the Post Capture button.
3 Click on the Tools menu, then select Self Tests.
Installation and General Information
7/30/2019 dcomref
26/36
24
Installation and General Information
Verifying Correct Operation
4 Click the All Tests button, then clickRun Tests.
5 Test progress and results can be viewed on the screen. A full set of results is available
from the specified log file.
If any of the Self Tests fail, see Returning for Service, Page 31.
6 Click the Close button to exit Self Test and return to the Monitor application.
Installation and General Information
7/30/2019 dcomref
27/36
25
Product Identification
Product Identification
Attached to the product is a serial number plate. The serial number on this label is in
the form GB00000101. The option number on this label indicates which hardware
options are fitted.
The contents of this manual apply to products with serial numbers GB00000101 and
above.
Build Status
Also attached to the product side panel is a BUILD STATUS label which indicates the
revision of hardware built into this product.
If you contact Agilent for service on this product the Agilent engineer may request the
Build Status number.
Installation and General Information
7/30/2019 dcomref
28/36
26
Statement of Compliance
Statement of Compliance
Electromagnetic Compatibility (EMC) Information
This product conforms with the protection requirements of European Council
Directive 89/336/EEC for Electromagnetic Compatibility (EMC).
The conformity assessment requirements have been met using the technicalConstruction file route to compliance, using EMC test specifications EN
55011:1991 (Group 1, Class A) and EN 50082-1:1992.
In order to preserve the EMC performance of the product, any cable which becomes
worn or damaged must be replaced with the same type and specification.
See the Declaration of Conformity on the next page.
Safety Information
This product has been designed and tested in accordance with publication EN61010-
1(1993) / IEC 61010-1(1990) +A1(1992) +A2(1995) Safety Requirements for
Electrical Equipment for Measurement, Control and Laboratory Use, and has been
supplied in a safe condition. The instruction documentation contains information
and warnings which must be followed by the user to ensure safe operation and to
maintain the instrument in a safe condition.
Noise Declaration (German)
LpA
7/30/2019 dcomref
29/36
27
Declaration of Conformity
Declaration of Conformity
For further information, please contact your local Agilent Technologies sales office, agent, or distributor.
DECLARATION OF CONFORMITYAccording to ISO/IEC Guide 22 and CEN/CENELEC EN45014
Manufacturers Name: Agilent Technologies UK Limited
Telecomms Networks Test Division
South Queensferry
West Lothian, EH30 9TG
Scotland, United Kingdom
Manufacturers Address:
Declares that the product
Product Name: Datacom Line Interface Module
Model Number: E7574A
Product Options: This declaration covers all options of the above product as detailed inTCF A-5951-9852-01.
EMC:
Conforms with the protection requirements of European Council Directive 89/336/EEC on the approximation of the
laws of the member states relating to electromagnetic compatibility, against EMC test specifications EN 55011:1991
(Group 1, Class A) and EN 50082-1:1992.
As Detailed in: Electromagnetic Compatibility (EMC)
Technical Construction File (TCF) No. A-5951-9852-01
Assessed by: DTI Appointed Competent Body
EMC Test Centre,GEC-Marconi Avionics Ltd.,
Maxwell Building,
Donibristle Industrial Park,
Hillend,
Dunfermline
KY11 9LB
Scotland, United Kingdom
Technical Report Number:6893/2200/CBR, dated 21 August 1997
Safety:
The product conforms to the following safety standards:
IEC 61010-1(1990) +A1(1992) +A2(1995) / EN 61010-1(1993)
The product herewith complies with the requirements of the General Product Safety Directive 92/59/EEC.
South Queensferry, Scotland. 15 May 2000
Installation and General Information
7/30/2019 dcomref
30/36
28
Safety Symbols
Safety Symbols
Safety Symbols Description
The Instruction Documentation Symbol. The product is marked with
this symbol when it is necessary for the user to refer to the
instructions in the supplied documentation.
Indicates hazardous voltages.
Indicates the field wiring terminal that must be connected to earth
ground before operating the equipment - protects against electrical
shock in case of fault.
Frame or chassis ground terminal - typically connects to the
equipments metal frame.
WARNING Warning denotes a hazard. It calls attention to a procedure, which if
not correctly performed or adhered to could result in injury or loss of
life. Do not proceed beyond a warning note until the indicated
conditions are fully understood and met.
CAUTION Caution denotes a hazard. It calls attention to a procedure, which if
not correctly performed or adhered to could result in damage to or
destruction of the instrument. Do not proceed beyond a caution note
until the indicated conditions are fully understood and met.
This symbol indicates that a device, or part of a device, may be
susceptible to electrostatic discharges (ESD) which can result in
damage to the product. Observe ESD precautions given on the
product, or its user documentation, when handling equipment
bearing this mark.
The CE mark shows that the product complies with all relevant
European Legal Directives.
The C-Tick mark is a registered trademark of the Australian
Communications Authority. This signifies compliance with the
Australian EMC Framework Regulations under the terms of the
Radio Communications Act of 1992.
ISM 1-A This is a symbol of an Industrial, Scientific, and Medical Group 1
Class A product.
ICES/NMB-001 This ISM device complies with Canadian ICES-001.Cet appareil ISM est conforme la norme NMB-001 du Canada.
Installation and General Information
ESD P i
7/30/2019 dcomref
31/36
29
ESD Precautions
ESD Precautions
CAUTION When making connections to the modules, review Connecting Interface Modules to
Bearers, Page 7.
The module contains components sensitive to electrostatic discharge.
To prevent component damage, carefully follow the handling precautions presentedbelow.
The smallest static voltage most people can feel is about 3500 volts. It takes less than
one tenth of that (about 300 volts) to destroy or severely damage static sensitive
circuits. Often, static damage does not immediately cause a malfunction but
significantly reduces the components life. Adhering to the following precautions will
reduce the risk of static discharge damage.
Keep the module in its conductive storage box when not installed in the Signaling
Advisor. Save the box for future storage of the module.
Before handling the module, select a work area where potential static sources are
minimized. Avoid working in carpeted areas and non-conductive chairs. Keep body
movement to a minimum. Agilent recommends that you use a controlled static work-
station.
Handle the module by its front-panel. Avoid touching any components or edge con-
nectors. When you install the module, keep one hand in contact with the protectivebag as you pick up the module with your other hand. Then, before installing the mod-
ule, ensure that you are grounded or make contact with the metal surface of the Sig-
naling Advisor with your free hand to bring you, the module, and the Signaling
Advisor to the same static potential. This also applies whenever you connect/dis-
connect cables on the front-panel.
Cleaning the Product
Use a soft, clean damp cloth to clean the outer surfaces.
Installation and General Information
C lib ti C l
7/30/2019 dcomref
32/36
30
Calibration Cycle
Calibration Cycle
This product does not require periodic calibration. Operational verification can be
confirmed by running the built-in Self Test, see page 22.
Operating Environment
This product is designed for indoor use only.
DO NOT operate the product in an explosive atmosphere or in the presence of
flammable gasses or fumes.
This product may be operated in environments within the following limits:
Temperature: +5o C to +40o C
Altitude up to 4,600 m
Humidity 20% to 80% relative humidity non condensing to 40oC. This
product should be protected from temperature extremes which may
cause condensation within the product enclosure.
To ensure adequate cooling do not obstruct air vents in the product cabinet. Air vents
are located at the front, on the underside and both sides of the product.
CAUTION This product is designed for use in Installation Category II and Pollution Degree 2
per IEC 61010 and 60664 respectively.
Installation and General Information
Storage and Shipment
7/30/2019 dcomref
33/36
31
Storage and Shipment
Storage and Shipment
This product may be stored or shipped in environments within the following limits:
Temperature -25o C to +60o C
Altitude Up to 15,250 m
Humidity 10% to 90% relative humidity to 60oC
This product should be protected from temperature extremes which could cause
internal or external condensation.
Returning for Service
When returning this product for service, please include the Signaling Advisor and
accessory cables.Tagging for Service. If the module is being returned to Agilent for service, please
complete a repair tag and attach it to the module. Ensure the following information is
sent with it:
Description of the problem (include the self-test results file, error messages or
specific performance data related to the problem).
Whether the problem is constant or intermittent.
Name and phone number of technical contact person.
Return address.
Model and option number of returned Signaling Advisor and module(s).
Full serial numbers of returned Signaling Advisor and module(s).
Mark shipping container FRAGILE to ensure careful handling.
Original Packaging. Containers and materials identical to those used in factory
packaging are available from Agilent offices.
Other Packaging. The following general instructions should be followed when
repackaging with commercially available materials:
Wrap instrument in heavy paper or plastic.
Use a strong shipping container. A double wall carton made of 350 pound test
material is adequate.
Installation and General Information
Web Site for Additional Product Information
7/30/2019 dcomref
34/36
32
Web Site for Additional Product Information
Use a layer of shock absorbing material 70 to 100 mm (3 to 4 inch) thick, around
all sides of the instrument to provide firm cushioning and prevent movementinside the container. Do not rely on pellets for shock absorption, as during transit
the instrument will sink to the bottom of the pellets.
Seal shipping container securely.
Weight and Dimensions
Weight: 0.5 kg
Dimensions: (height x width x depth)
21 mm x 122 mm x 150 mm
Web Site for Additional Product Information
You can use the Signaling Advisor to access the Web (requires a suitable LAN or
modem connection), or you can use any suitable PC with access to the Web.
http://onenetworks.comms.agilent.com/
Sales and Service Offices
7/30/2019 dcomref
35/36
An up-to-date list of Agilent Offices is available through
the Agilent Website at URL:
http://onenetworks.comms.agilent.com/
7/30/2019 dcomref
36/36
In this book
You will be shown how to install
an E7574A Datacom 4-Link
Interface Module into a Signaling
Advisor. Also provided is cabling
information and a verification
procedure.
Printed in UK 01/02
37907-90232