Dual-Band Combiner

Port 3

• Designedforco-sitingpurposes• Enablesfeedersharing• Suitableforindoororoutdoorapplications• Integratedauto-sensetechnologyforautomaticDC/AISGdetectionandby-passfunctionalityCombine Mode (near BTS):DC/AISGauto-senseforport1...2andshortcircuitdetectiononport3withbehaviouraccordingtologictableonpage2Split Mode (near antenna):AutomaticDC/AISGby-passfromport3toport1...2ifnoshortcircuitisdetected

• AshortcircuitdetectionisperformedbeforeallowingaDC/AISGsignaltobepassedfromoneoftheports1...2tothecommonoutput(port3)orviceversa.IfashortcircuitexiststhenaDC-StopisactivatedonthecorrespondingRF-path.

• ExternalDCstopavailableasanaccessory

1695 – 1780 / 2095 – 2200 MHzAWS4

1850 – 1920 / 1930 – 2000 MHzePCS

Technical Data

Type No. 78210778V01Double unit

Pass band Band 1 Band 2

[MHz][MHz]

1695 – 1780 (Rx) / 2095 – 2200 (Tx)1850 – 1920 (Rx) / 1930 – 2000 (Tx)

Insertion loss Port 1 ↔ Port 3 Port 2 ↔ Port 3

[dB][dB]

< 0.3 (1695 – 1780 / 2095 – 2200 MHz)< 0.3 (1850 – 1920 / 1930 – 2000 MHz)

Isolation Port 1 ↔ Port 2 [dB] > 50

VSWR < 1.25

Impedance [Ω] 50

Input power per Band [W] < 250 (operational)/<500(survival)Intermodulation products [dBc] < −160 (3rd order; with 2 x 20 W)

Temperature range [°C | °F] −40 ... +60 | −40 ... +140

Connectors 7-16 female (long neck)

Application Indoor or outdoor (IP 66)

DC/AISG transparency [mA] Auto-sense(max.2000)see logic table on page 2

DC supply [V DC] 7 – 30

Operating Current [mA] Typ. 6.5

Voltage drop [V] < 0.15

Lightning protection [kA] 3, 10/350 µs pulse

Mounting [mm | in] Wall mounting: With 4 screws (max. 8 | 0.315 diameter) / Mast mounting: With additional clamp set

Weight [kg | lbs] 6.1 | 13.45

Dimensions (w x h x d) [mm | in] 244 x 184.5 x 130.1 | 9.61 x 7.26 x 5.12(without connectors, without mounting brackets)

clamps

included

Port 1AWS

Port 2PCS

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com

All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com

Page2of378210778V01

936.

5085

Subj

ect t

o al

tera

tion.

Dual-Band Combiner

Clamp Set

50-Ohm load

Type No. Clamp set suitable for mast diameter of

734365 [mm | in] 45 – 125 | 1.77 – 4.92

Type No. Description78410367 50-Ohm load

Accessories (included)

1695 – 1780 / 2095 – 2200 MHzAWS4

1850 – 1920 / 1930 – 2000 MHzePCS

Please Note:Themountingplatescanberemovedbylooseningthescrews① to ④(M5x12)andreplacedwithothermeansofmounting,alwaysprovidedthatthemax.drilleddepthof7.5mmisrespectedwiththechoiceofreplacementscrews.As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions.Extraordinaryoperatingconditions,suchasheavyicingorexceptionaldynamicstress(e.g.straincausedbyoscillatingsupportstructures),mayresultinthebreakageofamastmounteddeviceorevencauseittofalltotheground.Thesefactsmustbeconsideredduringthesiteplanningprocess.TheDual-bandCombinerisdesignedtooperateundertheenvironmentalcondi-tionsasdescribedinETS300019-1-4class4.1Eandhavepassedenviron-mentaltestsasrecommendedinETS300019-2-4.The installation team must be properly qualified and also be familiar with the relevant national safety regulations.The details given in our data sheets have to be followed carefully when

installing the combiners and accessories.The limits for the coupling torque of RF connectors, recommended by the connector manufacturers must be obeyed.Terminate unused inputs with a suitable 50-Ohm load, e.g. 784 10367.Any previous datasheet issues have now become invalid.

DC/AISG Auto-Sense Functionality Table in Combine Mode

IncaseDC/AISGsignalsareappliedtotwoormoreportssimultaneouslythenallDC/AISGsignalswillbeblockedasshowninthelogictable below:

Connectors Logic table

Port 1 0 1 0 1Port 2 0 0 1 1Port 3 0 1 1 0

Order separately

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com

All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com

Dual-Band Combiner1695 – 1780 / 2095 – 2200 MHz

AWS41850 – 1920 / 1930 – 2000 MHz

ePCS

Dimensions

78210778V01 Page 3 of 3