SchemesForDischargeOfConditions_v1 1
0115 993 2599
Schemes for Discharge of Conditions
Application Number: 5/16/00117/CCR Date of Application: 31/03/16 Site Address: Sunnyside Spencer Academy, Great Hoggett Drive, Beeston Condition(s) to be Discharged: 5 Text of Condition(s): Notwithstanding details approved by Condition 3, prior to being installed, details of the external elements of the proposed hall ventilation system, including the height, design and siting of wind-catchers if required, shall be submitted to and approved by in writing the CPA. Schedule of Attachments: Revised drawing DE-A-35001, Manufacturers details and Design Strategy Fee Paid: £97.00 Note: Condition number(s) must be specified in the journal Applicant Contact Name: Jeremy Crawford Tel No.: 0115 9418475 Applications to be submitted by email to: development.management@nottscc.gov.uk
For Planning Use Only
Date of Receipt Target date:
Sent Rec’d Sent Rec’d Sent Rec’d
Highways Coal Authority HSE
Countryside Access EA Sport England
Ecology Severn Trent Ramblers
Planning Policy Gas English Heritage
Forestry/Arb Electric Highways Agency
Landscape Anglian Water (Bassetlaw) Forestry Commission
Waste/Energy Mgt Natural England Airfield
Noise –Clayton NWT British Horse Society
Crime Disorder Canal & River Trust Internal Drainage Board
Land Reclamation Network Rail Sara Williams - CFCS
Road Safety National Grid
Conservation/Arch National Planning Casework Unit
Conservation L/B
Notes
Natural Ventilation and Daylighting Specialists
North Frith Oasts, Ashes Lane, Hadlow, Kent, TN11 9QU T: 01732 850770 F: 01732 850949
This Appraisal Document and the calculations it contains are the Copyright of Passivent Ltd, and should not be transferred to a third party without the written permission of Passivent Ltd.
Design Strategy for
Sunnyside Primary School
For: Mr Nick Clews ABSN (Mechanical and Electrical)
Bank House 29A Plains Road
Mapperley Nottingham
NG3 5JU
Sales Person Edward Richmond
Telephone 07920 811957
Job Number: PC114135 Appraisal: 02
Client Code: ABS017 Date Created: 23/03/2016
Compiled By: William Halligan
E: projects@passivent.com
......................................................................................................................
Page 3 of 6 Design Strategy for Sunnyside Primary School - 114135
Record of Project Documentation Issue
Document Requested Date and by Amendment notes Based on Drawings /
Specification received Issue Date
Designer
Design 1 17/09/2015 via NC from Contractor
-
2399-FEA2399-BU-ZZZ-DE-A-41000-RevE-ProposedElevationSheet1of2 2399-FEA2399-BU-ZZZ-DE-A-41001-RevE-ProposedElevationSheet2of2 SH0185-M-11-01 - Ventilation
17/09/15 WH
*Checking is undertaken only where required, and recorded for any Design warranty submissions.
......................................................................................................................
Page 4 of 6 Design Strategy for Sunnyside Primary School - 114135
PROJECT SUMMARY A Natural Ventilation and Day Lighting Proposal has been undertaken for this project, on the basis of natural ventilation being considered the default strategy for school ventilation by the DCSF (Department for Children, Schools and Families). This report outlines our proposal for your consideration, summarised within the tables at the back of this document. The main building is a two-storey primary school development. The Assembly Hall will use displacement ventilation via roof-mounted terminals with separated chambers to channel air down into the building regardless of wind direction. The cooler, denser external air displaces warmer, lighter air upwards, which is drawn out through the leeward chambers of the terminals. This system can be used to provide free night time cooling when required. Low level motorised louvres / manual opening windows are also provided to assist the system. PROPOSAL ASSUMPTIONS The following assumptions have been made in respect of the design of this building, with regard to the usage and occupancy levels as detailed in the design information provided by the client: Wind speed data is referenced from CIBSE Guide Book A. For example using urban conditions (Ks = 0.35, a = 0.25) with a 50% of hourly means wind speed of 4m/s and a building eves height of 5m provides a site mean wind speed of 2.1m/s. This project has been calculated using urban conditions. Building Regulations require that background ventilation be provided to maintain good indoor air quality during the winter period. It is the responsibility of the client to confirm that this flow rate will achieve internal comfort conditions. Thermal mass, solar shading, glazing material and floor to ceiling heights are all aspects that can be addressed to reduce internal peak temperatures.
Room Type Ventilation Flow Rates Occupancy
Level Background Rapid Assembly Hall (Main / Dining)1 3 l/s/p - 100 1. The Schools Premises Regulations
CALCULATION METHOD The Airscoop calculation tool predicts the ventilation flow performance of Passivent Airscoop wind driven ventilation terminals. Its is based on the first principle formulas developed for the EDSL (TAS Software) ‘Passivent Airscoop Builder’. It was possible to construct this calculator after many years of extensive site testing of Airscoops at the Silsoe Research Institute. The calculation tool predicts the flow performance of the Airscoop wind driven ventilators when also using low level façade openings, if available. The flow performance is calculated for 16 equally spaced wind directions around 360 degrees. These are then averaged to provide an overall flow performance.
......................................................................................................................
Page 5 of 6 Design Strategy for Sunnyside Primary School - 114135
CONTROL PANELS
Correct control of components in a natural ventilation system is essential if it is to provide effective ventilation at minimum energy cost. Passivent provide a range of controls from basic to enhanced systems especially developed for natural ventilation. Passivent suggest that an iC8000 Controller is to be provided. The Passivent iC8000 (Intelligent Controller) 24V modulating, supplied standard with external night cooling, heating interlock and fire interlock, external temperature sensor and portable display interface screen to adjust settings on site (with pass code). Supplied as 2 Zone Panel Modules / 4 Zone Panel Modules. Supplied with combined CO2 and averaging temperature sensor. Supplied as BACnet (MS/TP) Enabled for internal communication and to allow read/write communication with a central BMS system. Preloaded with Passivent Natural Ventilation control software featuring a compensated internal temperature adjustment based on external temperature for seasonal variations and CO2 regime control when heating enabled (when CO2 present). DESIGN RESPONSIBILITY
This Natural Ventilation and Day Lighting proposal produced by Passivent, is offered as an advisory service and supersedes any previous Passivent design recommendations, written or oral. Any Proposal Assumptions noted above for the project should be read and verified. Any alterations to the design and the proposal assumptions should be notified to Passivent to ensure that ventilation proposal can be amended accordingly. A member of the Project Design team will usually submit a detailed design package to building control to demonstrate that the requirements for ventilation design and overheating analysis have been met. Passivent can be engaged as part of the Design team to undertake detailed thermal modelling analysis to support this submission. Passivent can offer a 12 year Design Warranty (on application) for the ventilation system, details available on request. This includes ventilation flow predictions and classroom overheating analysis.
..........................................................................................................................................................................................
Page 6 of 6 Design Strategy for Sunnyside Primary School - 114135
Natural Ventilation Strategy
Room Background / Night
Ventilation Inlet Rapid Ventilation Inlet Transfer
Exhaust / Supply Roof
Assembly Hall - - -
3no. 800mm x 800mm Basic Airscoop Roof Terminal Systems (Supply & Extract)
Notes:
- See quotation for product sizing and quantities. Product information about geometric free areas and cd values are also available. - All diffuser components are motorised with 24V (0-10V signal) actuators and provide thermal insulation when closed. - Airscoops are predominantly wind driven devices and should not be placed in sheltered locations, as this will reduce their effectiveness. - Please confer with the project acoustic consultant to ensure that the dB levels are meet for the relevant spaces, using the data supplied.
Controls Strategy Table
Standard Panels (iC8000 controller) for Natural Vent control
Panel Module No.
Zone No. Room Sensors
Control via Analogue output (max 2 No) Control On/Off
Louvre Damper
24v Window Actuators
(iWAC No.)
240v Window
Actuators (iWAC No.)
0-10V output for 3rd party
Fans
Boost Sweep Fans
1 (Master)
1 Assembly Hall Avg Temp & CO2 Yes No No No No
2 - - - - - - -
Brick piers form rhythm toelevation and link tofeature hall spine walland feature security walls
Coloured glazing orsimilar to classrooms toprovide identification andvisual interest
Line of secure featurewall
Coloured glazing orsimilar to entrance toprovide identification andvisual interest
Text &
S
ignage
Text &
S
ignage
Text &
S
ignage
Vertical metal cladding towalls and roof give hall asolid form
Plant space on line of piersto create separation and
symmetry using contrastingBrickwork
Kitchen ventilation systemto be designed byspecialist to incorporateodour suppression
2943
7302
9000
6265
Sunnyside SpencerAcademy
Painted Timberfence to plant andkitchen enclosure
Spine wall to edge ofhall forms abutmentfor cladding
All signage indicated isindicative only and will besubject to a separateplanning application byothers
Marley Alutek or similar approvedAluminium rainwater goods.Colour Black
text &
Sig
nage
Spine wall definesedge of hall
Line of secure featurewall
text &
Sig
nage
text &
Sig
nage
text &
Sig
nage
Ventilation system design andinstallation by specialistProposed unit:- Passivent BasicAirscoop 800x800x1109mmColour RAL 7016
Red brick to be used as themain areas of brickworkwith natural mortar formed withyellow sand
Spine wall and all featurebrickwork detailing and splashcourse formed using blackbrickwork using natural mortarwith pigment.
FRANKLIN ELLIS
The Old Pumphouse5 The Ropewalk, Nottingham, NG1 5DU
T 0115 941 8475E enquiry@franklinellis.co.ukW www.franklinellis.co.uk
ARCHITECTSArchitecture / Landscape / Interiors / Graphics / Project Management
REVISION NOTES
FEA-Titles-Standard-A1-Landscape-BlockRight version 2014-10-15 © copyright
SHEET NAME
STATUS CODE
GENERAL NOTES
1. Do not scale off this drawing unless a scale bar is provided2. Any ambiguities, omissions and errors on this drawing should be notifiedimmediately to the Architect before the commencement of works on site3. Dimensions are in millimetres unless otherwise stated4. Dimensions, unless otherwise indicated, are to the face of unfinishedblock walls or to the finished plaster face of stud partitions5. Dimensions are to be checked on site. Discrepancies are to be notifiedimmediately to the Architect before the commencement of works on site6. All levels are in meters unless otherwise stated7. This drawing is to be read in conjunction with all other relevant drawingsand specifications for this project
Checker
CDM REGULATIONS
Denotes a significant hazard or difficult to manage procedure.Please refer to Designer Hazard Register for further informationregarding mitigation of hazards.
Date Description IssuerRev
FULL DOCUMENT REFERENCE
STATUS
ProjectCode
SHEET SIZE SCALE
Originator Code& Proj Number
Vol/Zone
Level/Location
Type Dis Number
A1
REVISION
PROJECT NAME
PROJECT ADDRESS
CLIENT / USER NAME
PARTNER/ASSOCIATE PROJECT ARCHITECT
!
PROJECT PARTNERS
Identification / Location Sheet Number
REVISION DATE
c:\users
\jere
mycra
wfo
rd\d
ocum
ents
\23
99-A
rchM
aste
r S
chem
e 0
2_je
rem
ycra
wfo
rd.r
vt
1 : 100
IDate 144
Proposed Elevations
Planning
SUN-FEA2399-BU-ZZZ-DE-A-35001
P1
Education Funding Agency
Sunnyside Spencer Academy
Great Hoggett Drive, Beeston, Nottingham
Joe Taylor Joe Taylor
A 2015-06-26 Planning Issue JSC JT
B 2015-08-20 Layout revised in relation. toFF&E layout and GFTcomments. ED-11 omitted.Window Profiles revised toinclude central mullion.
JSC JT
C 2015-08-27 Rainwater downpipes & noteadded
MN JT
D 2015-10-02 Kitchen ventilation Grillesadded.
MN JT
E 2015-10-13 Ventilation system revised JSC JT
F 2016-01-25 Plan revised to indicate 8Noclassrooms
JSC JT
G 2016-02-12 Revised to reflect Constructionissue
JSC JT
H 2016-02-19 Planning Dimensions Added JSC JT
I Date 144 Hall ventilation amended toreflect the latest design strategy
JSC JT
North Elevation Proposed
West Elevation Proposed
South Elevation Proposed
East Elevation Proposed
0 10m 20m
20 m²
REHEAT KITCHENSpace 03
151 m²
ASSEMBLY HALLSpace 04
4 m²
PE STORE
Space 05 16 m²
PLANT ROOMSpace 06 27 m²
STAFF ROOM/WORK ROOMSpace 07
15 m²
PRINCIPAL'S ROOM
Space 08
13 m²
GENERAL OFFICESpace 09
8 m²
REPROGRAPHICSSpace 10
55 m²
JUNIOR CLASSROOM 02Space 51
2 m²
STORESpace 53
2 m²
StoreSpace 55
69 m²
CORRIDOR 04
Space 33
2 m²
LOCKERSSpace 52
4 m²
CORRIDOR 03
Space 50
21 m²
TOILET 03Space 49
10 m²
GROUP ROOM 02 SEN-MI-MEDICAL
Space 48
55 m²
INFANT CLASSROOMSpace 45
55 m²
PRACTICAL PLUSSpace 42
2 m²
STORESpace 44
2 m²
STORESpace 46
2 m²
STORESpace 24
2 m²
STORESpace 26
55 m²
RECEPTION CLASSROOMSpace 25
55 m²
NURSERY CLASSROOMSpace 22
9 m²
INTERVIEW ROOMSpace 16
13 m²
Corridor 01Space 15
7 m²
HYGIENESpace 20
9 m²
GROUP ROOM 01 NURSERY
Space 19
2 m²
LOCKERSSpace 27
2 m²
LOCKERSSpace 43
55 m²
JUNIOR CLASSROOM 01Space 54
4 m²
SERVER ROOM
Space 18
2 m²
LOCKERSSpace 23
2 m²
LOCKERSSpace 47
2 m²
LOCKERSSpace 56
North
20 m²
LEARNING RESOURCE SPACESpace 17
Roof LightAbove
By Department Legend
Basic Teaching Space
Halls
Learning Resource Space
Staff and Administraion
Storage
Catering Facilities
Toilets and Personal Care
Plant
Circulation
18 m²
DINING EQUIPMENT STORESpace 01
W-01 W-02 W-03 W-04 W-05
W-13W-14W-15W-16W-17W-19W-20
W-24 W-25 W-26ED-01 ED-02 ED-03
ED-07ED-08ED-09ED-10ED-11
ED-12
D-S01
D-S02
D-S04
D-S07 D-S10
D-S55
D-S08
D-S13
D-S16
D-S20
D-S18-1
D-S24 D-S22 D-S25 D-S26
D-S44D-S42D-S45D-S46
ED-14
ED-13
D-S09
D-S11
D-S53
D-S32
D-S51D-S54
D-S48
W-29W-28 W-31 W-32 W-33
W-38W-39W-40W-41W-42W-43W-44
32 m²
CORRIDOR 02
Space 32
11 m²
Entrance LobbySpace 13
RS-01
RC
S-0
1
3 m²
Access WC 01Space 11
3 m²
Access WC 02Space 12
9 m²
WASH-UPSpace 02
56.285m
D-S12
W-23
W-22
W-21
12 m²
TOILET 01Space 21
55 m²
CLASSROOMSpace 28
2 m²
STORESpace 29
2 m²
LOCKERSSpace 30
31 m²
RESOURCE SPACESpace 31
4 m
²
CO
RR
IDO
R 0
5
Sp
ace
38
6 m²
OFFICESpace 34
3 m²
CLEANERS STORESpace 35
3 m²
STAFF WCSpace 36
15 m²
TOILET 02Space 37
2 m²
LOCKERSSpace 40
2 m²
STORESpace 41
55 m²
CLASSROOMSpace 39
D-S05
D-S18
D-S19
D-S28 D-S29
D-S31
D-S34
D-S35
D-S36
D-S41D-S39
ED-04
ED-05
ED-06
W-06 W-07
W-09
W-10
W-11W-12
W-08
W-34 W-35
W-36W-37
W-34 W-35
W-27
RWPSVP
SV
P
SV
P
SVP
SVP
SVP
SVP SVP
SVP
SVPSVPSVPSVP
SVPSVPSVPSVPSVP
SVP
SVP
RWP
RWP
RWP
RW
P
RWP RWP RWP
RWP RWP RWP RWP
Internal floor gullyExternal floor gully
RWP
1 m²
StoreSpace 57
D-S57
SVP
W-18
FRANKLIN ELLIS
The Old Pumphouse5 The Ropewalk, Nottingham, NG1 5DU
T 0115 941 8475E enquiry@franklinellis.co.ukW www.franklinellis.co.uk
ARCHITECTSArchitecture / Landscape / Interiors / Graphics / Project Management
REVISION NOTES
FEA-Titles-Standard-A1-Landscape-BlockRight version 2014-10-15 © copyright
SHEET NAME
STATUS CODE
GENERAL NOTES
1. Do not scale off this drawing unless a scale bar is provided2. Any ambiguities, omissions and errors on this drawing should be notifiedimmediately to the Architect before the commencement of works on site3. Dimensions are in millimetres unless otherwise stated4. Dimensions, unless otherwise indicated, are to the face of unfinishedblock walls or to the finished plaster face of stud partitions5. Dimensions are to be checked on site. Discrepancies are to be notifiedimmediately to the Architect before the commencement of works on site6. All levels are in meters unless otherwise stated7. This drawing is to be read in conjunction with all other relevant drawingsand specifications for this project
Checker
CDM REGULATIONS
Denotes a significant hazard or difficult to manage procedure.Please refer to Designer Hazard Register for further informationregarding mitigation of hazards.
Date Description IssuerRev
FULL DOCUMENT REFERENCE
STATUS
ProjectCode
SHEET SIZE SCALE
Originator Code& Proj Number
Vol/Zone
Level/Location
Type Dis Number
A1
REVISION
PROJECT NAME
PROJECT ADDRESS
CLIENT / USER NAME
PARTNER/ASSOCIATE PROJECT ARCHITECT
!
PROJECT PARTNERS
Identification / Location Sheet Number
REVISION DATE
c:\users
\jere
mycra
wfo
rd\d
ocum
ents
\23
99-A
rchM
aste
r S
chem
e 0
2_je
rem
ycra
wfo
rd.r
vt
1 : 100
I2016-02-02
Plan Proposed
Planning
SUN-FEA2399-BU-000-DP-A-15001
P1
Education Funding Agency
Sunnyside Spencer Academy
Great Hoggett Drive, Beeston, Nottingham
Joe Taylor Joe Taylor
A 2015-06-26 Planning Issue JSC JT
B 2015-07-16 Tags added JSC JT
C 2015-08-20 Layout revised in relation toFF&E layout and GFTcomments. ED-11 omitted.
JSC JT
D 2015-09-15 Additional Notes Added JSC JT
E 2015-09-21 Door & Window numbers added MN JT
F 2015-10-15 Hall ventilation outline added JSC JT
G 2015-12-09 EFA Amendments JET JT
H 2016-01-25 Plan revised to indicate 8Noclassrooms
JSC JT
I 2016-02-02 Revised for Construction Issue JSC JT
1 : 100
Proposed Floor Plan1
Recommended