SchemesForDischargeOfConditions_v1 1 0115 993 2599 Schemes for Discharge of Conditions Application Number: 5/16/00117/CCR Date of Application: 31/03/16 Site Address: Sunnyside Spencer Academy, Great Hoggett Drive, Beeston Condition(s) to be Discharged: 5 Text of Condition(s): Notwithstanding details approved by Condition 3, prior to being installed, details of the external elements of the proposed hall ventilation system, including the height, design and siting of wind-catchers if required, shall be submitted to and approved by in writing the CPA. Schedule of Attachments: Revised drawing DE-A-35001, Manufacturers details and Design Strategy Fee Paid: £97.00 Note: Condition number(s) must be specified in the journal Applicant Contact Name: Jeremy Crawford Tel No.: 0115 9418475 Applications to be submitted by email to: [email protected] For Planning Use Only Date of Receipt Target date: Sent Rec’d Sent Rec’d Sent Rec’d Highways Coal Authority HSE Countryside Access EA Sport England Ecology Severn Trent Ramblers Planning Policy Gas English Heritage Forestry/Arb Electric Highways Agency Landscape Anglian Water (Bassetlaw) Forestry Commission Waste/Energy Mgt Natural England Airfield Noise Clayton NWT British Horse Society Crime Disorder Canal & River Trust Internal Drainage Board Land Reclamation Network Rail Sara Williams - CFCS Road Safety National Grid Conservation/Arch National Planning Casework Unit Conservation L/B Notes

CPA. Revised drawing DE-A-35001, Manufacturers details and

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CPA. Revised drawing DE-A-35001, Manufacturers details and

SchemesForDischargeOfConditions_v1 1

0115 993 2599

Schemes for Discharge of Conditions

Application Number: 5/16/00117/CCR Date of Application: 31/03/16 Site Address: Sunnyside Spencer Academy, Great Hoggett Drive, Beeston Condition(s) to be Discharged: 5 Text of Condition(s): Notwithstanding details approved by Condition 3, prior to being installed, details of the external elements of the proposed hall ventilation system, including the height, design and siting of wind-catchers if required, shall be submitted to and approved by in writing the CPA. Schedule of Attachments: Revised drawing DE-A-35001, Manufacturers details and Design Strategy Fee Paid: £97.00 Note: Condition number(s) must be specified in the journal Applicant Contact Name: Jeremy Crawford Tel No.: 0115 9418475 Applications to be submitted by email to: [email protected]

For Planning Use Only

Date of Receipt Target date:

Sent Rec’d Sent Rec’d Sent Rec’d

Highways Coal Authority HSE

Countryside Access EA Sport England

Ecology Severn Trent Ramblers

Planning Policy Gas English Heritage

Forestry/Arb Electric Highways Agency

Landscape Anglian Water (Bassetlaw) Forestry Commission

Waste/Energy Mgt Natural England Airfield

Noise –Clayton NWT British Horse Society

Crime Disorder Canal & River Trust Internal Drainage Board

Land Reclamation Network Rail Sara Williams - CFCS

Road Safety National Grid

Conservation/Arch National Planning Casework Unit

Conservation L/B

Notes

Page 2: CPA. Revised drawing DE-A-35001, Manufacturers details and

Natural Ventilation and Daylighting Specialists

North Frith Oasts, Ashes Lane, Hadlow, Kent, TN11 9QU T: 01732 850770 F: 01732 850949

This Appraisal Document and the calculations it contains are the Copyright of Passivent Ltd, and should not be transferred to a third party without the written permission of Passivent Ltd.

Design Strategy for

Sunnyside Primary School

For: Mr Nick Clews ABSN (Mechanical and Electrical)

Bank House 29A Plains Road

Mapperley Nottingham

NG3 5JU

Sales Person Edward Richmond

Telephone 07920 811957

Job Number: PC114135 Appraisal: 02

Client Code: ABS017 Date Created: 23/03/2016

Compiled By: William Halligan

E: [email protected]

Page 3: CPA. Revised drawing DE-A-35001, Manufacturers details and
Page 4: CPA. Revised drawing DE-A-35001, Manufacturers details and

......................................................................................................................

Page 3 of 6 Design Strategy for Sunnyside Primary School - 114135

Record of Project Documentation Issue

Document Requested Date and by Amendment notes Based on Drawings /

Specification received Issue Date

Designer

Design 1 17/09/2015 via NC from Contractor

-

2399-FEA2399-BU-ZZZ-DE-A-41000-RevE-ProposedElevationSheet1of2 2399-FEA2399-BU-ZZZ-DE-A-41001-RevE-ProposedElevationSheet2of2 SH0185-M-11-01 - Ventilation

17/09/15 WH

*Checking is undertaken only where required, and recorded for any Design warranty submissions.

Page 5: CPA. Revised drawing DE-A-35001, Manufacturers details and

......................................................................................................................

Page 4 of 6 Design Strategy for Sunnyside Primary School - 114135

PROJECT SUMMARY A Natural Ventilation and Day Lighting Proposal has been undertaken for this project, on the basis of natural ventilation being considered the default strategy for school ventilation by the DCSF (Department for Children, Schools and Families). This report outlines our proposal for your consideration, summarised within the tables at the back of this document. The main building is a two-storey primary school development. The Assembly Hall will use displacement ventilation via roof-mounted terminals with separated chambers to channel air down into the building regardless of wind direction. The cooler, denser external air displaces warmer, lighter air upwards, which is drawn out through the leeward chambers of the terminals. This system can be used to provide free night time cooling when required. Low level motorised louvres / manual opening windows are also provided to assist the system. PROPOSAL ASSUMPTIONS The following assumptions have been made in respect of the design of this building, with regard to the usage and occupancy levels as detailed in the design information provided by the client: Wind speed data is referenced from CIBSE Guide Book A. For example using urban conditions (Ks = 0.35, a = 0.25) with a 50% of hourly means wind speed of 4m/s and a building eves height of 5m provides a site mean wind speed of 2.1m/s. This project has been calculated using urban conditions. Building Regulations require that background ventilation be provided to maintain good indoor air quality during the winter period. It is the responsibility of the client to confirm that this flow rate will achieve internal comfort conditions. Thermal mass, solar shading, glazing material and floor to ceiling heights are all aspects that can be addressed to reduce internal peak temperatures.

Room Type Ventilation Flow Rates Occupancy

Level Background Rapid Assembly Hall (Main / Dining)1 3 l/s/p - 100 1. The Schools Premises Regulations

CALCULATION METHOD The Airscoop calculation tool predicts the ventilation flow performance of Passivent Airscoop wind driven ventilation terminals. Its is based on the first principle formulas developed for the EDSL (TAS Software) ‘Passivent Airscoop Builder’. It was possible to construct this calculator after many years of extensive site testing of Airscoops at the Silsoe Research Institute. The calculation tool predicts the flow performance of the Airscoop wind driven ventilators when also using low level façade openings, if available. The flow performance is calculated for 16 equally spaced wind directions around 360 degrees. These are then averaged to provide an overall flow performance.

Page 6: CPA. Revised drawing DE-A-35001, Manufacturers details and

......................................................................................................................

Page 5 of 6 Design Strategy for Sunnyside Primary School - 114135

CONTROL PANELS

Correct control of components in a natural ventilation system is essential if it is to provide effective ventilation at minimum energy cost. Passivent provide a range of controls from basic to enhanced systems especially developed for natural ventilation. Passivent suggest that an iC8000 Controller is to be provided. The Passivent iC8000 (Intelligent Controller) 24V modulating, supplied standard with external night cooling, heating interlock and fire interlock, external temperature sensor and portable display interface screen to adjust settings on site (with pass code). Supplied as 2 Zone Panel Modules / 4 Zone Panel Modules. Supplied with combined CO2 and averaging temperature sensor. Supplied as BACnet (MS/TP) Enabled for internal communication and to allow read/write communication with a central BMS system. Preloaded with Passivent Natural Ventilation control software featuring a compensated internal temperature adjustment based on external temperature for seasonal variations and CO2 regime control when heating enabled (when CO2 present). DESIGN RESPONSIBILITY

This Natural Ventilation and Day Lighting proposal produced by Passivent, is offered as an advisory service and supersedes any previous Passivent design recommendations, written or oral. Any Proposal Assumptions noted above for the project should be read and verified. Any alterations to the design and the proposal assumptions should be notified to Passivent to ensure that ventilation proposal can be amended accordingly. A member of the Project Design team will usually submit a detailed design package to building control to demonstrate that the requirements for ventilation design and overheating analysis have been met. Passivent can be engaged as part of the Design team to undertake detailed thermal modelling analysis to support this submission. Passivent can offer a 12 year Design Warranty (on application) for the ventilation system, details available on request. This includes ventilation flow predictions and classroom overheating analysis.

Page 7: CPA. Revised drawing DE-A-35001, Manufacturers details and

..........................................................................................................................................................................................

Page 6 of 6 Design Strategy for Sunnyside Primary School - 114135

Natural Ventilation Strategy

Room Background / Night

Ventilation Inlet Rapid Ventilation Inlet Transfer

Exhaust / Supply Roof

Assembly Hall - - -

3no. 800mm x 800mm Basic Airscoop Roof Terminal Systems (Supply & Extract)

Notes:

- See quotation for product sizing and quantities. Product information about geometric free areas and cd values are also available. - All diffuser components are motorised with 24V (0-10V signal) actuators and provide thermal insulation when closed. - Airscoops are predominantly wind driven devices and should not be placed in sheltered locations, as this will reduce their effectiveness. - Please confer with the project acoustic consultant to ensure that the dB levels are meet for the relevant spaces, using the data supplied.

Controls Strategy Table

Standard Panels (iC8000 controller) for Natural Vent control

Panel Module No.

Zone No. Room Sensors

Control via Analogue output (max 2 No) Control On/Off

Louvre Damper

24v Window Actuators

(iWAC No.)

240v Window

Actuators (iWAC No.)

0-10V output for 3rd party

Fans

Boost Sweep Fans

1 (Master)

1 Assembly Hall Avg Temp & CO2 Yes No No No No

2 - - - - - - -

Page 8: CPA. Revised drawing DE-A-35001, Manufacturers details and
Page 9: CPA. Revised drawing DE-A-35001, Manufacturers details and

Brick piers form rhythm toelevation and link tofeature hall spine walland feature security walls

Coloured glazing orsimilar to classrooms toprovide identification andvisual interest

Line of secure featurewall

Coloured glazing orsimilar to entrance toprovide identification andvisual interest

Text &

S

ignage

Text &

S

ignage

Text &

S

ignage

Vertical metal cladding towalls and roof give hall asolid form

Plant space on line of piersto create separation and

symmetry using contrastingBrickwork

Kitchen ventilation systemto be designed byspecialist to incorporateodour suppression

2943

7302

9000

6265

Sunnyside SpencerAcademy

Painted Timberfence to plant andkitchen enclosure

Spine wall to edge ofhall forms abutmentfor cladding

All signage indicated isindicative only and will besubject to a separateplanning application byothers

Marley Alutek or similar approvedAluminium rainwater goods.Colour Black

text &

Sig

nage

Spine wall definesedge of hall

Line of secure featurewall

text &

Sig

nage

text &

Sig

nage

text &

Sig

nage

Ventilation system design andinstallation by specialistProposed unit:- Passivent BasicAirscoop 800x800x1109mmColour RAL 7016

Red brick to be used as themain areas of brickworkwith natural mortar formed withyellow sand

Spine wall and all featurebrickwork detailing and splashcourse formed using blackbrickwork using natural mortarwith pigment.

FRANKLIN ELLIS

The Old Pumphouse5 The Ropewalk, Nottingham, NG1 5DU

T 0115 941 8475E [email protected] www.franklinellis.co.uk

ARCHITECTSArchitecture / Landscape / Interiors / Graphics / Project Management

REVISION NOTES

FEA-Titles-Standard-A1-Landscape-BlockRight version 2014-10-15 © copyright

SHEET NAME

STATUS CODE

GENERAL NOTES

1. Do not scale off this drawing unless a scale bar is provided2. Any ambiguities, omissions and errors on this drawing should be notifiedimmediately to the Architect before the commencement of works on site3. Dimensions are in millimetres unless otherwise stated4. Dimensions, unless otherwise indicated, are to the face of unfinishedblock walls or to the finished plaster face of stud partitions5. Dimensions are to be checked on site. Discrepancies are to be notifiedimmediately to the Architect before the commencement of works on site6. All levels are in meters unless otherwise stated7. This drawing is to be read in conjunction with all other relevant drawingsand specifications for this project

Checker

CDM REGULATIONS

Denotes a significant hazard or difficult to manage procedure.Please refer to Designer Hazard Register for further informationregarding mitigation of hazards.

Date Description IssuerRev

FULL DOCUMENT REFERENCE

STATUS

ProjectCode

SHEET SIZE SCALE

Originator Code& Proj Number

Vol/Zone

Level/Location

Type Dis Number

A1

REVISION

PROJECT NAME

PROJECT ADDRESS

CLIENT / USER NAME

PARTNER/ASSOCIATE PROJECT ARCHITECT

!

PROJECT PARTNERS

Identification / Location Sheet Number

REVISION DATE

c:\users

\jere

mycra

wfo

rd\d

ocum

ents

\23

99-A

rchM

aste

r S

chem

e 0

2_je

rem

ycra

wfo

rd.r

vt

1 : 100

IDate 144

Proposed Elevations

Planning

SUN-FEA2399-BU-ZZZ-DE-A-35001

P1

Education Funding Agency

Sunnyside Spencer Academy

Great Hoggett Drive, Beeston, Nottingham

Joe Taylor Joe Taylor

A 2015-06-26 Planning Issue JSC JT

B 2015-08-20 Layout revised in relation. toFF&E layout and GFTcomments. ED-11 omitted.Window Profiles revised toinclude central mullion.

JSC JT

C 2015-08-27 Rainwater downpipes & noteadded

MN JT

D 2015-10-02 Kitchen ventilation Grillesadded.

MN JT

E 2015-10-13 Ventilation system revised JSC JT

F 2016-01-25 Plan revised to indicate 8Noclassrooms

JSC JT

G 2016-02-12 Revised to reflect Constructionissue

JSC JT

H 2016-02-19 Planning Dimensions Added JSC JT

I Date 144 Hall ventilation amended toreflect the latest design strategy

JSC JT

North Elevation Proposed

West Elevation Proposed

South Elevation Proposed

East Elevation Proposed

Page 10: CPA. Revised drawing DE-A-35001, Manufacturers details and

0 10m 20m

20 m²

REHEAT KITCHENSpace 03

151 m²

ASSEMBLY HALLSpace 04

4 m²

PE STORE

Space 05 16 m²

PLANT ROOMSpace 06 27 m²

STAFF ROOM/WORK ROOMSpace 07

15 m²

PRINCIPAL'S ROOM

Space 08

13 m²

GENERAL OFFICESpace 09

8 m²

REPROGRAPHICSSpace 10

55 m²

JUNIOR CLASSROOM 02Space 51

2 m²

STORESpace 53

2 m²

StoreSpace 55

69 m²

CORRIDOR 04

Space 33

2 m²

LOCKERSSpace 52

4 m²

CORRIDOR 03

Space 50

21 m²

TOILET 03Space 49

10 m²

GROUP ROOM 02 SEN-MI-MEDICAL

Space 48

55 m²

INFANT CLASSROOMSpace 45

55 m²

PRACTICAL PLUSSpace 42

2 m²

STORESpace 44

2 m²

STORESpace 46

2 m²

STORESpace 24

2 m²

STORESpace 26

55 m²

RECEPTION CLASSROOMSpace 25

55 m²

NURSERY CLASSROOMSpace 22

9 m²

INTERVIEW ROOMSpace 16

13 m²

Corridor 01Space 15

7 m²

HYGIENESpace 20

9 m²

GROUP ROOM 01 NURSERY

Space 19

2 m²

LOCKERSSpace 27

2 m²

LOCKERSSpace 43

55 m²

JUNIOR CLASSROOM 01Space 54

4 m²

SERVER ROOM

Space 18

2 m²

LOCKERSSpace 23

2 m²

LOCKERSSpace 47

2 m²

LOCKERSSpace 56

North

20 m²

LEARNING RESOURCE SPACESpace 17

Roof LightAbove

By Department Legend

Basic Teaching Space

Halls

Learning Resource Space

Staff and Administraion

Storage

Catering Facilities

Toilets and Personal Care

Plant

Circulation

18 m²

DINING EQUIPMENT STORESpace 01

W-01 W-02 W-03 W-04 W-05

W-13W-14W-15W-16W-17W-19W-20

W-24 W-25 W-26ED-01 ED-02 ED-03

ED-07ED-08ED-09ED-10ED-11

ED-12

D-S01

D-S02

D-S04

D-S07 D-S10

D-S55

D-S08

D-S13

D-S16

D-S20

D-S18-1

D-S24 D-S22 D-S25 D-S26

D-S44D-S42D-S45D-S46

ED-14

ED-13

D-S09

D-S11

D-S53

D-S32

D-S51D-S54

D-S48

W-29W-28 W-31 W-32 W-33

W-38W-39W-40W-41W-42W-43W-44

32 m²

CORRIDOR 02

Space 32

11 m²

Entrance LobbySpace 13

RS-01

RC

S-0

1

3 m²

Access WC 01Space 11

3 m²

Access WC 02Space 12

9 m²

WASH-UPSpace 02

56.285m

D-S12

W-23

W-22

W-21

12 m²

TOILET 01Space 21

55 m²

CLASSROOMSpace 28

2 m²

STORESpace 29

2 m²

LOCKERSSpace 30

31 m²

RESOURCE SPACESpace 31

4 m

²

CO

RR

IDO

R 0

5

Sp

ace

38

6 m²

OFFICESpace 34

3 m²

CLEANERS STORESpace 35

3 m²

STAFF WCSpace 36

15 m²

TOILET 02Space 37

2 m²

LOCKERSSpace 40

2 m²

STORESpace 41

55 m²

CLASSROOMSpace 39

D-S05

D-S18

D-S19

D-S28 D-S29

D-S31

D-S34

D-S35

D-S36

D-S41D-S39

ED-04

ED-05

ED-06

W-06 W-07

W-09

W-10

W-11W-12

W-08

W-34 W-35

W-36W-37

W-34 W-35

W-27

RWPSVP

SV

P

SV

P

SVP

SVP

SVP

SVP SVP

SVP

SVPSVPSVPSVP

SVPSVPSVPSVPSVP

SVP

SVP

RWP

RWP

RWP

RW

P

RWP RWP RWP

RWP RWP RWP RWP

Internal floor gullyExternal floor gully

RWP

1 m²

StoreSpace 57

D-S57

SVP

W-18

FRANKLIN ELLIS

The Old Pumphouse5 The Ropewalk, Nottingham, NG1 5DU

T 0115 941 8475E [email protected] www.franklinellis.co.uk

ARCHITECTSArchitecture / Landscape / Interiors / Graphics / Project Management

REVISION NOTES

FEA-Titles-Standard-A1-Landscape-BlockRight version 2014-10-15 © copyright

SHEET NAME

STATUS CODE

GENERAL NOTES

1. Do not scale off this drawing unless a scale bar is provided2. Any ambiguities, omissions and errors on this drawing should be notifiedimmediately to the Architect before the commencement of works on site3. Dimensions are in millimetres unless otherwise stated4. Dimensions, unless otherwise indicated, are to the face of unfinishedblock walls or to the finished plaster face of stud partitions5. Dimensions are to be checked on site. Discrepancies are to be notifiedimmediately to the Architect before the commencement of works on site6. All levels are in meters unless otherwise stated7. This drawing is to be read in conjunction with all other relevant drawingsand specifications for this project

Checker

CDM REGULATIONS

Denotes a significant hazard or difficult to manage procedure.Please refer to Designer Hazard Register for further informationregarding mitigation of hazards.

Date Description IssuerRev

FULL DOCUMENT REFERENCE

STATUS

ProjectCode

SHEET SIZE SCALE

Originator Code& Proj Number

Vol/Zone

Level/Location

Type Dis Number

A1

REVISION

PROJECT NAME

PROJECT ADDRESS

CLIENT / USER NAME

PARTNER/ASSOCIATE PROJECT ARCHITECT

!

PROJECT PARTNERS

Identification / Location Sheet Number

REVISION DATE

c:\users

\jere

mycra

wfo

rd\d

ocum

ents

\23

99-A

rchM

aste

r S

chem

e 0

2_je

rem

ycra

wfo

rd.r

vt

1 : 100

I2016-02-02

Plan Proposed

Planning

SUN-FEA2399-BU-000-DP-A-15001

P1

Education Funding Agency

Sunnyside Spencer Academy

Great Hoggett Drive, Beeston, Nottingham

Joe Taylor Joe Taylor

A 2015-06-26 Planning Issue JSC JT

B 2015-07-16 Tags added JSC JT

C 2015-08-20 Layout revised in relation toFF&E layout and GFTcomments. ED-11 omitted.

JSC JT

D 2015-09-15 Additional Notes Added JSC JT

E 2015-09-21 Door & Window numbers added MN JT

F 2015-10-15 Hall ventilation outline added JSC JT

G 2015-12-09 EFA Amendments JET JT

H 2016-01-25 Plan revised to indicate 8Noclassrooms

JSC JT

I 2016-02-02 Revised for Construction Issue JSC JT

1 : 100

Proposed Floor Plan1