Chapter 17 Loss Control. 17–2 Chapter 17 Lesson Goal After completing this lesson, the student...

Preview:

Citation preview

Chapter 17— Loss Control

17–2

Chapter 17 Lesson Goal

After completing this lesson, the student shall be able to perform loss control operations

17–3

Philosophy of Loss Control

• Minimize damage & provide customer service through effective recovery efforts

• Builds goodwill

(Continued)

17–4

DISCUSSION QUESTION

How does effective loss control contribute to goodwill in the community?

17–5

Salvage & Overhaul

• Most effective means of loss control

• Restoration of the property

• Salvage - methods & operating procedures that reduce fire, water & smoke damage during & after fires

• Overhaul – Searching for & extinguishing hidden fires

17–6

Salvage

Operations that aid in reducing primary & secondary damage during firefighting

• Primary damage is caused by the fire

• Secondary damage is caused by fire suppression activities

(Continued)

17–7

Salvage

• Both primary & secondary damage can be minimized through salvage

• Some damages cannot be avoided

• Starts as soon as adequate personnel are available

• May be done simultaneously with fire attack

17–8

Overhaul

• Consists of operations involved in searching for & extinguishing hidden or remaining fires

• Protecting the scene & preserving evidence are components of overhaul

(Continued)

17–9

Overhaul

If possible, do not start overhaul operations until

• Fire is under control

• Fire cause has been determined

• Evidence has been identified & protected

17–10

Salvage

Methods & operating procedures by which FFs attempt to save property & reduce further damage

• Removing property

• Covering property

• Other means

(Continued)

17–11

Salvage

Proper salvage operations

• Early planning

• Knowing the procedures

• Being familiar with tools & equipment

17–12

Planning for Salvage Operations

• Efficient operations require planning & training

• SOPs should be developed

(Continued)

17–13

Planning for Salvage Operations

Pre-incident plans

• High-value contents

• Residential occupancies

• Commercial occupancies

17–14

DISCUSSION QUESTION

What should be done with other smaller items, such as photographs & documents?

17–15

Salvage Procedures

• Operations can be started at same time as fire attack

• Members performing salvage should be in full PPE & SCBA

• Group building contents into compact piles

• Salvage usually begins a floor below fire

17–16

Salvage Procedures

• Group household furnishings in center of the room

• Remove pictures & place w/ furniture

• Raise furniture off wet floors

(Continued)

17–17

Salvage Procedures

• Commercial occupancies present special challenges

• Place stock on pallets

• Be very cautious of high-piled stock that gets wet at the bottom

(Continued)

17–18

Salvage Procedures

• Large quantities of water can be removed by a variety of methods

Remove toilets fixtures

Use water chutes

Use squeegee’s

• Water may ruin finishes; wipe off surfaces

17–19

Salvage Covers

• Made of waterproof canvas materials

• Manufactured in various sizes

• Have reinforced corners & edge hems

• Used to:

Control runoff water

Collect debris

Cover furniture

As a catchall

(Continued)

17–20

Salvage Covers

• Synthetic covers

Lightweight

Easy to handle

Economical

Indoor & outdoor use

• Some covers may be disposable

17–21

Salvage Cover Maintenance

Proper cleaning, drying, & repairing increases service life

(Continued)

17–22

Salvage Cover Maintenance

Canvas salvage covers

• Wetting or rinsing with hose stream & scrubbing w/ a broom

• Detergent solution if needed

• Don’t let dry when dirty

• Should be completely dry before being folded & placed in service

(Continued)

17–23

Salvage Cover Maintenance

Synthetic salvage covers

• Do not require as much maintenance as canvas

• Rinse w/ hose stream & scrub w/ broom

• Use approved detergent on heavy stains

• Do not dry in direct sunlight

(Continued)

17–24

Salvage Cover Maintenance

• After salvage covers are dry, examine for damage, i.e. holes

• Look up at the underside to locate holes

• Mark holes w/ chalk or marking pen

• Repair holes w/ duct tape

17–25

DISCUSSION QUESTION

Why should you repair holes in salvage covers?

17–26

Salvage Equipment

• Should be located in a readily accessible area on apparatus

• SOPs dictate where equipment is carried & who performs operations

(Continued)

17–27

Salvage Equipment

• Keep smaller tools/equipment in a salvage toolbox

• Plastic tub may be used for supplies

17–28

Typical Salvage Equipment

• Electrician’s pliers

• Sidecutters

• Various chisels

• Tin snips

• Tin roof cutter

• Adjustable wrenches

• Pipe wrenches

• Hammer

• Sledgehammer

• Hacksaw

• Crosscut handsaw

• Heavy-duty stapler and staples

• Linoleum knife

• Wrecking bar (Continued)

17–29

Typical Salvage Equipment

• Padlock & hasp

• Hinges

• Screwdriver(s)

• Battery-operated power tools

• Hydraulic jack

• Assortment of nails

• Assortment of screws

• Plastic sheeting

• Wooden laths

• Wooden wedges

• Soft wood plugs

• Sawdust

(Continued)

17–30

Typical Salvage Equipment

• Mops

• Squeegees

• Scoop shovels

• Brooms

• Mop buckets with wringers

• Automatic sprinkler kit

• Water vacuum

• Submersible pump & discharge hose

• Sponges

• Chamois

• Paper towels

• Assortment of rags

(Continued)

17–31

Typical Salvage Equipment

• 100-foot (30 m) length of electrical cable

• Junction boxes

• Approved ground fault interruption device

• Salvage covers

• J-Hooks

• S-hooks

• Floor runners

• Duct tape

• Plastic bags

• Cardboard boxes

• Styrofoam blocks

• Rope

• Bungee cords

17–32

Equipment Descriptions

Automatic sprinkler kit

• Needed for buildings protected by automatic sprinkler systems

• Used to stop flow of water from an open sprinkler

(Continued)

17–33

Equipment Descriptions

Carryalls — Used to carry debris, catch falling debris, & provide a water basin for immersing small burning objects

(Continued)

17–34

Equipment Descriptions

• Floor runners — Protect floor coverings; lightweight, tough material, heat & water resistant, easy to maintain

• Used in hallways or traffic areas

(Continued)

17–35

Equipment Descriptions

Dewatering devices

• Used to remove water from basements, elevator shafts, & sumps

• Do not use FrPD pumpers because water can damage pumps

• Trash-type pumps are best for salvage

(Continued)

17–36

Equipment Descriptions

• Water vacuum — removes water from areas where water is not deep enough to be picked up by other means

• 4-5 gallon capacity

• Backpack & floor models

• PPE, i.e. SCBA, limited w/ backpack model

17–37

Equipment Descriptions

• J-hooks — Driven into walls or wooden framing to provide a strong point from which to hang things

• S-hooks — Used like J-hooks but cannot be driven into walls or framing; must have a horizontal ledge

17–38

Equipment Descriptions

Grommets

• Found along the edges of salvage covers

• Can be used w/ rope, S & J hooks

17–39

One-Firefighter Spread with a Rolled Salvage Cover

• One person can quickly unroll a cover

• May be carried on the shoulder or under the arm

• Same may be done w/ folded cover

17–40

Two-Firefighter Spread with a Folded Salvage Cover

• Large covers cannot be easily handled by a single FF

• Carry this fold on the shoulder w/ open edges next to neck

• Position cover so carrier can grab lower corners & second FF can grab upper corners (Continued)

17–41

Two-Firefighter Spread with a Folded Salvage Cover

Balloon throw is most common method for deployment

(Continued)

17–42

Using Chutes: Removing Water

• Practical way to remove water that comes through the ceiling from upper floor

• Used to route water short distances through windows or doors

• May be constructed on floor below firefighting operations

(Continued)

17–43

Using Chutes: Removing Water

• Prepared chutes are approximately 10 feet (3 m) long

• Chutes can be constructed from plastic sheeting, a heavy-duty stapler, & duct tape & pike poles or a ladder

•Firefighter I•17–44

Using Chutes: Constructing a Catchall

• Constructed from a salvage cover placed on the floor to hold small amounts of water

(Continued)

17–45

Using Chutes: Constructing a Catchall

• Temporarily control large amounts of water

• Place into position as soon as possible

• Usually requires 2 people

Using Chutes: Constructing a Catchall

• Open salvage cover fully

• Roll sides inward to fit area

• Fold ends over to form a 90° angle

• Roll in

• Lock corner

17–46

17–47

DISCUSSION QUESTION

How much water do you think a catchall can carry?

17–48

Splicing Covers

• Used when:

Objects/groupings are large

Long chutes or catchalls need to be made

• Splice covers w/ watertight joints

(Continued)

17–49

Splicing a Chute to a Catchall

• Method of removing accumulated water should be prepared

• Submersible pumps may be used

• Water chute spliced to the catchall

17–50

Covering Openings

• One of final parts of salvage operations

• Prevents damage by weather

• Cover doors/windows

• Cover openings in roofs

(Continued)

17–51

DISCUSSION QUESTION

What is the point of covering doors, windows, and openings on a home that has already been affected by fire?

Overhaul

Operations conducted once main body of fire has been extinguished

• Searching for & extinguishing hidden or remaining fire

• Placing building & contents in safe condition

17–52

(Continued)

17–53

Overhaul

• Ideally, fire investigators begin their work before overhaul starts

• Overhaul is completed after:

Determining fire cause

Recognizing & preserving evidence of arson

17–54

DISCUSSION QUESTION

What is the purpose of overhaul?

17–55

Safety During Overhaul

Steps required

• Inspecting premises to ensure building is safe to work in

• Developing operational plan

• Providing tools & equipment

• Eliminating or reducing hazards

(Continued)

17–56

Safety During Overhaul

Toxic gases

• Common & dangerous threat during overhaul

• Wear appropriate PPE, including respiratory protection

(Continued)

17–57

Safety During Overhaul

• Other hazards are present, such as fire-weakened floors

• Mark or barricade hazardous areas

• Use gloves & eye protection

(Continued)

17–58

Safety During Overhaul

• Physical conditioning & correct lifting are necessary

• Fatigue is a preventable cause of injury

17–59

Overhaul Tools and Equipment

• Pike poles & plaster hooks

• Axes

• Prying tools

• Power saws, drills, & screwdrivers

(Continued)

17–60

Overhaul Tools and Equipment

• Carryall, buckets, & tubs

• Shovels, bale hooks, & pitchforks

• Thermal imaging camera

17–61

Supervision of Overhaul

• By a supervisor/officer not directly engaged in overhaul tasks

• Fire investigator should be involved

17–62

Fire Safety During Overhaul

• Size of charged hoselines in overhaul may not be the same as attack lines

• Do not disconnect all fire apparatus from hydrants

Leave at least one pumper connected

(Continued)

17–63

Fire Safety During Overhaul

• Attack lines used for overhaul are 1.5”

• One attack line should be available to put out hot spots or flare ups

• Place nozzle so it will not cause additional damage

• Do not allow water damage from leaking hoselines

(Continued)

17–64

Overhaul Safety Considerations

• Maintain situational awareness

• Work in teams of 2 or more

• Maintain awareness of exit routes

• Maintain a RIC

(Continued)

17–65

Overhaul Safety Considerations

• Monitor personnel for rehab

• Beware of hidden gas or electrical utilities in walls & floors

• Continue using accountability system

17–66

Locating Hidden Fires

• Before starting a search, evaluate condition of area

• Factors that affect condition of building:

Intensity of fire

Amount of water used for control

17–67

Indicators of Loss of Structural Integrity

• Weakened floors

• Concrete that has spalled

• Weakened steel roof members

• Walls offset

• Weakened roof trusses

• Mortar in wall joints opened

(Continued)

17–68

Indicators of Loss of Structural Integrity

• Heavy storage on mezzanines or upper floors

• Water pooled on upper floors

• Large quantities of wet insulation

Detecting Hidden Fires

• Sight

Cracked plaster, peeling paint, discoloration

• Touch

Using back of hand, feel walls for heat

17–69

Never remove gloves while inside

Detecting Hidden Fires

• Sound

Popping, crackling, or hissing of steam

• Electronic sensors

Thermal imaging camera

Sees heat signature

17–70

17–71

Overhaul Procedures

• Begins in area of most severe fire damage

• Looking for fire extension should begin as soon as possible after fire is declared under control

• Systematically carried out

(Continued)

17–72

Overhaul Procedures

• If fire extended to other areas, path must be determined

• When floor beams are burned at ends or where they enter a party wall, flush the voids in the wall w/ water

(Continued)

17–73

Overhaul Procedures

• Check far side of wall to see if fire or water has come through

• Thoroughly check insulation materials

Hidden fires can smolder for many hours

May be necessary to remove insulation

17–74

Understanding Basic Building Construction

• Assists FFs in searching for hidden fires

• Windows or doors

Fire may remain within frames or casings

Open these areas to ensure complete extinguishment

(Continued)

17–75

Building Construction and Overhaul

• When fire has burned around combustible roof or cornice, open cornice & inspect for hidden fires

• Balloon construction — Check the attic & basement for fire extension

(Continued)

17–76

Building Construction and Overhaul

• Opening concealed/void spaces

• Open all spaces immediately that may conceal a hot spot

Move the furnishings of the room to locations where they will not be damaged

Consider electrical wiring, gas piping, or plumbing

• Make neat, planned openings to ensure extinguishment & facilitate restoration

(Continued)

17–77

Building Construction and Overhaul

• Ceilings may be opened from below using a pike pole

• The plaster must first be broken on some ceilings

• When pulling a ceiling, do not stand directly under area to be opened

(Continued)

17–78

Building Construction and Overhaul

• Always position body between area being pulled & doorway to keep exit route from being blocked

• Pull down & away from your position

• Always wear full PPE, including SCBA

(Continued)

17–79

Building Construction and Overhaul

• Small burning objects

Submerge entire objects in containers of water

Bathtubs, sinks, lavatories, wash tubs

• Take mattresses & other large furniture outside & overhaul it

(Continued)

17–80

Building Construction and Overhaul

• Scorched or partially burned articles may prove helpful to an investigator

• Use of wetting agents such as Class A foam is valuable

Cotton, upholstery, & baled goods

Must break bales of rags, cotton, hay apart

17–81

Summary

• Customer service is the core of everything that fire departments do

• Loss control is an important component of fire department service delivery & is only one aspect of customer-service opportunities

(Continued)

17–82

Summary

• Salvage & overhaul operations are two of the most effective means of loss control

• Planning, procedures, & equipment are essential for effective loss-control operations

17–83

Skills

• Clean, inspect, and repair a salvage cover.

• Fold a salvage cover for a two-firefighter spread.

• Spread a folded salvage cover — Two-firefighter balloon throw.

• Construct a water chute with pike poles

• Construct a catchall. (Skill Sheet FF-I-112)