AVL Opacimeter

Preview:

DESCRIPTION

opacimetru

Citation preview

08.04.2010

AVL Opacimeter 439

2Originator, location of data storage, date of creation

AVL Opacimeter Generations

G001 (1998)G001 (1998) G004 (2003)G004 (2003)

1992 1994 1996 1998 2000 2002 2004

3Originator, location of data storage, date of creation

Principle of Opacity Measurement

Full Flow Opacimeter

in - line

end - of - line

filled with dynamic

pressure

filled with pumpQ = const.•

Opacimeter

Opacimeter

Partial Flow Opacimeter

4Originator, location of data storage, date of creation

AVL 439 Measurement Principle

Lamp II00Detector II

T, pT, p

LL

I / I0 = Extinction = Absorption + Scattering

NN = 100 ·(1- e – kk · L)

kk = – · ln(1- )NN

100

1

L

= e – kk · L = (1 – )NN

100

I

I0

I0 ...... Light intensity without smoke

I ....... Light intensity with smoke

N ...... Opacity (%)

k ....... Absorption coefficient (m-1)

L ....... Measuring length (m)

5Originator, location of data storage, date of creation

AVL Opacimeter 439 G004

Partial Flow Opacimeter

� For test cell, chassis dynamometer

and on-board testing

� High sensitivity

� High time response

� Legal test runs according to

ECE-R 24

HD EURO 3/4 ELR test

ISO 8178

SAE J 1667

� Exhaust probe conditioning

6Originator, location of data storage, date of creation

AVL 439 Technical Specification

Measurement value resolution :Measurement value resolution : 0.1% opacity or 0.0025 m0.1% opacity or 0.0025 m--11

ZeroZero--level stability:level stability: 0.1% opacity or 0.0025 m0.1% opacity or 0.0025 m--11 / 30 min/ 30 min

Signal rise time:Signal rise time: 0.1 s (at flow rate 40 0.1 s (at flow rate 40 LpmLpm))

Sampling rate for opacity signal:Sampling rate for opacity signal: 50 Hz50 Hz

Electronic measurement value filterElectronic measurement value filter

Moving averageMoving average 0.02 ... 10 s0.02 ... 10 s

Bessel filter of 2nd orderBessel filter of 2nd order 0.2, 0.35, 0.5, 1.0, 1.077, 1.5, 2 s0.2, 0.35, 0.5, 1.0, 1.077, 1.5, 2 s

1st order low pass1st order low pass 0.02 ... 10 s0.02 ... 10 s

Not filteredNot filtered

7Originator, location of data storage, date of creation

AVL 439 Design Features

� Optical Length 430 mm

→ optimised sensitivity

� Diaphragm Sampling Pump

→ constant flow rate

→ constant filling of the measurement chamber

→ high accuracy

� Sample Conditioning

→ standard temperature 100°C

→ adjustable from 70 ... 120°C

→ signal stability

→ temperature protection

8Originator, location of data storage, date of creation

AVL 439 Measurement Chamber

ProbeProbeININ

ProbeProbeOUTOUT

ProbeProbeOUTOUT

ConditioningConditioning100100°°CC

Thermostatically Thermostatically controlled heatercontrolled heater

Orifice

Heated window

element

Light

detector

Light

source

OrificeFrame

Measurement

chamber

Calibration

cartridgeHeated window

element

9Originator, location of data storage, date of creation

AVL 439 Zero-Level Stability

0

-0.02

-0.01

0.01

0.02

0 300 600

-0.86

-0.43

0

0.43

0.86

sigma = 0.001 m-1

k [

m-1

]

N [

%]

Time (s)

10Originator, location of data storage, date of creation

AVL 439 Signal Rise Time

0

50

100

-50 50 150 250

Sig

na

l –

[%]

Time [ms]

90%

10% T10

T90

100 ms

11Originator, location of data storage, date of creation

AVL 439 for Engine Homologation

according to ECE-R24

physical response time ≤ 0.4 selectrical signal rise time 0.9 ... 1.1 s

electronic filter time 1.1 s

resolution N = 1%, k = 0.02 m-1

according to EURO 3 ELR

physical response time ≤ 0.2 s

electrical signal rise time ≤ 0.05 s

electronic filter time 1 s Bessel filter

resolution N = 1%, k = 0.02 m-1

Time – s

C1 C2 M1 M2 M3 M4 M5 M6Ab

so

rpti

on

co

eff

icie

nt

k –

[m

-1]

∆k

XM

Sp

eed

100 %

cycle 1

EURO 3 ELR Test

cycle 2 cycle 3 cycle 4

selectedpoint

C

B

A

Lo

ad

10 %

12Originator, location of data storage, date of creation

AVL 439 Functional Diagram

13Originator, location of data storage, date of creation

439 Opacimeter High Pressure Option

14Originator, location of data storage, date of creation

AVL 439 for Engine Homologation

Check with Certified Calibration Filters

according to

ECE-R24

� with 50% calibration filter

� limit of agreement is +/- 1%

EURO 3/4 ELR

ISO 8178-9

ISO 11614

SAE J 1667

� with 10%, 20% and 40% filters

� limit of agreement is +/- 2%

15Originator, location of data storage, date of creation

AVL 439 Test Cell Installation

Exhaust line

Tube 10 x 1

Welding piece

200Exhaust

Probe

Backflow

Engine

Silencer

16Originator, location of data storage, date of creation

AVL 439 Dimensions

650 mm

420 m

m

450 mm

Dimensions

650 × 420 × 450 mm (W × H × D)

Weight

approx. 47 kg

17Originator, location of data storage, date of creation

European Load Response (ELR) Test

Sp

eed

100 %

Cycle 1 Cycle 2 Cycle 3 Cycle 4

Selectedpoint

C

B

A

Lo

ad

10 %

18Originator, location of data storage, date of creation

AVL 439 for ELR Test Application

Time [s]

0 60 120 180 240 300 360

2500

2000

1500

1000

500

0

50

40

30

20

10

0

Op

ac

ity

[%]

Sp

ee

d[r

pm

]T

orq

ue

[Nm

]

19Originator, location of data storage, date of creation

AVL 439 for Transient Engine Development

Time [s]

2500

2000

1500

1000

500

0

50

40

30

20

10

0

Op

ac

ity

[%]

Sp

ee

d [

rpm

]T

orq

ue

[N

m]

0 200016001200800400

20Originator, location of data storage, date of creation

AVL 439 Load Response

0

200

400

600

800

1000

1200

1400

Lo

ad

[Nm

]

-20

0

20

40

60

80

100

120

Alp

ha

[%

]

0

10

20

30

40

50

60

-2 -1 0 1 2 3 4 5 6 7 8

Time [s]

Op

ac

ity

[%]

625 ml/30s594 ml/30s625 ml/30s - 30%Alpha

� Nozzle variation (injection rate/time)

� Heavy-duty 6-cylinder engine, vH=7 l

� n = 1200 rpm

� Limitation of max. opacity N = 30%

21Originator, location of data storage, date of creation

AVL 439 in NEDC Test: Start Phase

Comparison Opacity , Euro-Super, NEDC -7°C

0

10

20

30

40

50

60

70

80

90

100

0 100 200 300 400 500 600 700 800 900 1000 1100 1200

Time [s]

Opacity after Catalyst - NEDC

Op

acity [%

]

-350

-300

-250

-200

-150

-100

-50

0

50

100

150

1,8 l GDI, EURO 22,0 l MPFI, EURO 3Speed

Spe

ed

[km

/h]

Opacity scale 0-100%

22Originator, location of data storage, date of creation

Comparison Opacity , Euro-Super, NEDC -7°C

0

1

2

3

4

5

6

7

8

9

10

0 100 200 300 400 500 600 700 800 900 1000 1100 1200

Time [s]

Opacity after Catalyst - NEDC

Op

acity [

%]

-350

-300

-250

-200

-150

-100

-50

0

50

100

150

1,8 l GDI, EURO 22,0 l MPFI, EURO 3Speed

Sp

ee

d [

km

/h]

AVL 439 in NEDC Test: Running-In Phase

Opacity scale 0-10%

23Originator, location of data storage, date of creation

AVL 439 Data Handling

Opacity raw value

analogue + RS 232

ECE-R24

cycle aid and display

EURO III ELR

cycle pre-programmed

BESSEL filter

SLIDING AVERAGE

24Originator, location of data storage, date of creation

Opacity / Soot / Particulates

FS

N

Op

acit

y

SO42-

C

HC

AshF

ilte

r G

ravim

etr

y

Black CarbonBlack Carbon

0

0.4

0.8

1.2

1.6

2

0 2 4 6 8 10

Carbon particulates [mg/m3]

Op

acit

y [

%]

0

0.4

0.8

1.2

1.6

2

0 2 4 6 8 10

Total particulates [mg/m3]

Op

acit

y [

%]

Opacity can often be correlated to:

but:but:

not tonot to

ParticulatesParticulates

25Originator, location of data storage, date of creation

Opacity vs. Black Soot (FSN)

0

5

10

15

20

25

30

35

40

45

0 0,5 1 1,5 2 2,5 3 3,5 4 4,5

Filter Smoke Number (FSN)

Op

acity

(%)

2.5 l, TDI, CR

2.4 l, IDI

4l, TDI

12 l, TDI, CR

8 l, TDI

4,2 l, DI

26Originator, location of data storage, date of creation

Example of Sensitivity and Zero Stability

0.00

0.05

0.10

0 10 20 30

Time – minutes

FSN = 0.20 0.120.37 0.13

Opacity Values at Low Soot Emission

k (

m)

-1

Recommended