Alcatel-Lucent 7360INTELLIGENT SERVICES ACCESS MANAGER FX | RELEASE 4.3P R O D U C T I N F O R M A T I O N
3HH-10116-AAAA-TCZZA Edition 01 Released
Alcatel-Lucent ProprietaryThis document contains proprietary information of Alcatel-Lucent and is not to be disclosedor used except in accordance with applicable agreements.Copyright 2011 © Alcatel-Lucent. All rights reserved.
When printed by Alcatel-Lucent, this document is printed on recycled paper.
Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice.
Alcatel, Lucent and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
Copyright 2011 Alcatel-Lucent.All rights reserved.
Disclaimers
Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications.
This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products.
However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers.
This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 iii3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Preface
This preface provides general information about the documentation set for the 7360 Intelligent Services Access Manager FX (7360 ISAM FX).
Scope
This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, CLI and TL1 commands, and software upgrade and migration procedures.
Audience
This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the 7360 ISAM FX.
Prerequisite knowledge
The reader must be familiar with general telecommunications principles.
Safety information
For ETSI safety information, see the 7360 ISAM FX Safety Manual.
Preface
iv July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
The following are examples of how special information is presented in this document.
Document conventions
The following conventions are used in this documentation set.
AcronymsSee the glossary included with the System Description for FD 100/320Gbps NT and FX NT for the expansion of acronyms used in this documentation set.
Release notes
Be sure to refer to the release notes (such as the Customer Release Notes or Emergency Fix Release Note) issued for software loads of the 7360 ISAM before you install or use the 7360 ISAM FX . The release notes provide important information about the software load.
Danger — Danger indicates that the described activity or situation may result in serious personal injury or death; for example, high voltage or electric shock hazards.
Warning — Warning indicates that the described activity or situation may, or will, cause equipment damage or serious performance problems.
Caution — Caution indicates that the described activity or situation may, or will, cause service interruption.
Note — A note provides information that is, or may be, of special interest.
Preface
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 v3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Documents
Table 1 lists the documents that make up the 7360 ISAM FX Release 4.3 documentation set.
Table 1 7360 ISAM FX Release 4.3 documentation set
Title Description Part number
Documentation CD
7360 ISAM FX CD CD containing all the documents in the 7360 ISAM FX documentation set (1)
3HH-10103-AAAA
General documentation
Product Information Provides general system information for the 7360 ISAM FX 3HH-10116-AAAA-TCZZA
System Description for FD 100/320Gbps NT and FX NT
Provides conceptual information for:
• the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT
• the 7360 ISAM FX equipped with an FX NT
3HH-09811-BAAA-TQZZA
Safety Manual Provides general safety guidelines when handling, installing, or operating the 7360 ISAM FX equipment
3HH-10126-AAAA-TCZZA
Hardware documentation
FX Hardware Installation Guide
Describes the hardware installation for the 7360 ISAM FX equipment
3HH-10127-AAAA-RJZZA
TL1 documentation
TL1 Commands and Messages for FD 100/320Gbps NT and FX NT
Describes the TL1 commands and messages for:
• the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT
• the 7360 ISAM FX equipped with an FX NT
3HH-09857-BAAA-TCZZA
Operations and Maintenance Using TL1 for FD 100/320Gbps NT and FX NT
Provides task-oriented procedures using TL1 for operating and maintaining:
• the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT
• the 7360 ISAM FX equipped with an FX NT
3HH-09858-BAAA-TQZZA
CLI documentation
CLI Commands for FD 100/320Gbps NT and FX NT
Describes the CLI commands for:
• the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT
• the 7360 ISAM FX equipped with an FX NT
3HH-08079-DDAA-TCZZA
Operations and Maintenance Using CLI for FD 100/320Gbps NT and FX NT
Provides task-oriented procedures using CLI for operating and maintaining:
• the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT
• the 7360 ISAM FX equipped with an FX NT
3HH-10104-BAAA-TQZZA
IHub System Basics, Management and OAM Guide for FD 100/320Gbps NT and FX NT
Describes the IHub system basics, system management and OAM (Operations and Maintenance)
3HH-10106-AAAA-TQZZA
IHub Interface Guide for FD 100/320Gbps NT and FX NT
Describes the IHub system interfaces 3HH-10107-AAAA-TQZZA
(1 of 2)
Preface
vi July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Note(1) Software documentation is not included on the 7360 ISAM documentation CD
IHub QoS Guide for FD 100/320Gbps NT and FX NT
Describes the IHub Quality of Service 3HH-10108-AAAA-TQZZA
IHub Router Configuration and Protocols Guide for FD 100/320Gbps NT and FX NT
Describes the IHub router configuration and router protocols 3HH-10110-AAAA-TQZZA
IHub Services Guide for FD 100/320Gbps NT and FX NT
Describes the IHub services 3HH-10109-AAAA-TQZZA
IHub MPLS Guide for FD 100/320Gbps NT and FX NT
Describes the IHub MPLS services 3HH-10111-AAAA-TQZZA
Software documentation(1)
Software Installation Guide Describes the software management of the 7302 ISAM, the 7330 ISAM FTTN, the 7356 ISAM FTTB and the 7360 ISAM FX equipment
3HH-07196-AAAA-RJZZA
Software Upgrade and Migration Application Procedures
Provides instructions for using the automated tools for upgrading and migrating the software for the 7302 ISAM, the 7330 ISAM FTTN, the 7356 ISAM FTTB and the 7360 ISAM FX
3HH-08277-AAAA-TCZZA
Title Description Part number
(2 of 2)
Contents
Preface iiiScope ............................................................................................... iiiAudience ............................................................................................... iiiPrerequisite knowledge ............................................................................... iiiSafety information..................................................................................... iiiDocument conventions ................................................................................ ivRelease notes........................................................................................... ivDocuments ...............................................................................................v
1 — System Overview 1-11.1 Introduction.............................................................................. 1-21.2 System Architecture .................................................................... 1-61.3 Network Management ................................................................. 1-171.4 Equipment Management .............................................................. 1-181.5 Board Capabilities and Dimensioning ............................................... 1-191.6 NT Redundancy Support............................................................... 1-251.7 CLEI Codes............................................................................... 1-26
2 — Subracks 2-12.1 Introduction.............................................................................. 2-22.2 General ................................................................................... 2-22.3 7360 ISAM FX Subracks ................................................................. 2-22.4 Supported Plug-in Units ................................................................ 2-62.5 Dummy Front Panels.................................................................... 2-7
3 — Physical Rack Equipment 3-13.1 General ................................................................................... 3-23.2 Universal Rack ........................................................................... 3-2
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 vii3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Contents
3.3 Side Plates ............................................................................... 3-53.4 Rack Doors ............................................................................... 3-63.5 Key Locks ................................................................................. 3-7
4 — Rack Configurations 4-14.1 General ................................................................................... 4-24.2 Rack Configurations..................................................................... 4-2
5 — SFP Optical Modules 5-15.1 Introduction.............................................................................. 5-25.2 SFP Optical Modules .................................................................... 5-2
A. Board Mnemonics A-1A.1 Board Mnemonics........................................................................ A-2
Index
viii July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-13HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1 — System Overview
1.1 Introduction 1-2
1.2 System Architecture 1-6
1.3 Network Management 1-17
1.4 Equipment Management 1-18
1.5 Board Capabilities and Dimensioning 1-19
1.6 NT Redundancy Support 1-25
1.7 CLEI Codes 1-26
1 — System Overview
1-2 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1.1 Introduction
The 7360 ISAM FX is a frame based Multi Service Access Platform, offering high-density fiber connections for multimedia, high-speed internet access, voice and business services.
General Network Topology
Figure 1-1 shows the basic network topology.
Figure 1-1 General network topology
Note — Possible user interface types are not limited to the types shown on the figure.
xDSL ISAM
Video
FE/GE
FE/GE
IP Edge Router / BRAS
EMAN
EthernetSwitch NSP IP backbone
NSP IP backbone
NSP IP backbone
xDSLLT
EthLT
VoiceLT
GPONLT
xDSL
Ethernet
Voice
DS1/E1
Video
NT
ISAM shelf
ISAM
OMCIGPON
ISAM OLT
FE/GE/10GE
FE/GE/10GE
ONT/ONU
Ethernet
Voice
DS1/E1
EPONLT
OAMEPON
ONT/ONU
xDSL/Ethernet
Voice
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-33HH-10116-AAAA-TCZZA Edition 01 Released Product Information
User Side
At the user side, each 7360 ISAM FX shelf can terminate:
• Ethernet user interfaces• Passive Optical Network (PON) interfaces
It is possible to connect subtending DSLAMs to the FE/GE/10GE links at the user side in:
• cascading mode: a chain of 1 subtending ISAM per ISAM; see Figure 1-2• star mode: multiple subtending ISAMs per ISAM; see Figure 1-3• ring mode (except when there is a ring behind a Hub-ISAM); see Figure 1-4.
Figure 1-2 Cascading Topology
Figure 1-3 Star Topology
ISAMISAM
Cascading up to three levels
ISAM
Userinterfaces
k*FE/GE/10GEk*FE/GE/10GE
EMAN
Userinterfaces User
interfaces
ISAMISAM
ISAM
Userinterfaces
k*FE/GE/10GE
EMAN
k*FE/GE/10GE
Userinterfaces
Userinterfaces
1 — System Overview
1-4 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Figure 1-4 Ring Topology
Network Side
At the network side, the 7360 ISAM terminates FE, GE, or 10GE links. The following configurations are possible:
• Connected to one or more Ethernet SwitchesThe Ethernet links can be connected to one or more Ethernet Switches. These Ethernet Switches forward the frames over the Ethernet based aggregation access network until they reach the IP Edge Router or BRAS of the corresponding Network Service Provider (NSP). At the IP Edge Router or BRAS, the frames enter the IP backbone of the NSP.
• More than one FE/GE/10GE link (link aggregation)In case of more than one link, Ethernet link aggregation is used.
• Directly connected to an IP Edge RouterThe 7360 ISAM FX can be connected directly to the IP Edge Router or BRAS. The Ethernet aggregation network is reduced to one or more parallel Ethernet links.
• Can also be connected to a Multi-protocol Label Switching (MPLS) network.
ISAM
k*FE/GE/10GE
ISAM
Userinterfaces
k*FE/GE/10GE
ISAM
EMANISAM
k*FE/GE/10GEUserinterfaces
Userinterfaces
Userinterfaces
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-53HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Figure 1-5 Network Connections
Note — A link is a term which is used to refer to the physical layer of an interface of the 7360 ISAM FX, for example, an Ethernet link.
ISAMUserinterfaces
FE/GE
m x FE/GE/10GE
n x FE/GE/10GE
IP Edge Router /BRAS
EMAN
EthernetSwitch
NSP IP backbone
NSP IP backbone
NSP IP backbone
ISAMUserinterfaces
FE/GENSP IP backbone
1 — System Overview
1-6 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1.2 System Architecture
Functional DecompositionThe ISAM is built as a typical multiplexer which can be equipped with the following main boards:
• a Network Termination (NT) board (optionally 1+1 redundant)• a NT Input/Output board (optional)• a set of Ethernet Line Termination (LT) boards implementing the user interfaces.• Gigabit Passive Optical Network (GPON) LT boards• Ethernet Passive Optical Network (EPON) LT boards
Figure 1-6 ISAM Decomposition
The ISAM’s management plane, control plane, and most of the data plane is realized on the NT board and on the LT boards.
Figure 1-7 ISAM System Decomposition
ISAM
NT
NTIO
LT
LT-applique
…
LTNT
iHub
System control
iHub control
Switch/Router IWF
Transport
Data plane
Control plane
LT-Control
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-73HH-10116-AAAA-TCZZA Edition 01 Released Product Information
FX NT Board
The FX NT board consist of an IHub subsystem and a System Control subsystem.
• The IHub subsystem has enhanced L2 functionality (VPLS based) and L3 functionality (VPRN based) and consists of a 10-Gigabit-Ethernet switch/router device, and IHub control software (SW).
• The System Control subsystem implements the management plane of the system (both the NT board and the LT boards) and part of the control plane (subscriber management in particular). The System Control consists of SW running on a powerful general purpose processor. It shares this processor with the IHub control SW (on a separate processor core).
Line Termination (LT) Boards
Line Termination (LT) boards are built from an InterWorking Function (IWF), a Transport subsystem and an LT-Control subsystem.
• The transport subsystem terminates the physical layer of the subscriber interfaces. It varies with the type of access technology used (Ethernet,...).
• The IWF processes the packets in the fast path. It is capable of handling frames at L2 (basically bridging) and L3 (basically IP forwarding), including sophisticated filtering and traffic management, all at the line rate of the transport medium.
• The LT-Control subsystem takes care of the slow path control plane and internal Operations And Maintenance applications.
GPON LT Boards
The GPON functionality of the ISAM extends the system boundaries via up to 128 Optical Network Terminations (ONTs) over a fiber plant that can reach 10s of kilometers out from the GPON LT boards located in an ISAM shelf.
These GPON LT boards provide the physical interfaces from the ISAM shelf towards the Customer Premises Equipment, that is, the ONTs.
EPON LT Boards
The EPON functionality of the ISAM extends the system boundaries via up to 64 Optical Network Terminations (ONTs) over a fiber plant that can reach 10s of kilometers out from the EPON LT boards located in an ISAM shelf.
These EPON LT boards provide the physical interfaces from the ISAM shelf towards the Customer Premises Equipment, that is, the ONTs.
Physical DecompositionFigure 1-8 shows the general functional architecture of the ISAM, from the viewpoint of its forwarding capabilities.
1 — System Overview
1-8 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Figure 1-8 High-level ISAM Architecture
An ISAM shelf consists out of the following board types:
• NT board• LT boards
NT Board
Provisions are made to equip two NT boards in the shelf. These NT boards can act as an active / stand-by pair for all functions.
The following NT boards are supported in FX equipment:
• FANT-F (480 Gbps NT board):This NT board with integrated IHub subsystem provides the following links on the front panel:
• One electrical RJ45 interface:This port supports 10/100/1000Base-T
• Four 10GE SFPplus port:These ports can work both in 1 GE mode (with standard SFP optics) and in 10 GE mode (with SFPplus optics).
LT Boards
The LT boards consists of a IWF, the transport termination and the LT control.
The LT boards, also known as Line Interface Modules (LIMs), use a different interworking function between the user side and the Ethernet network side, depending on the board type. Table 1-1 shows the supported LT boards with their physical interface types, density (that is, number of lines per board) and Interworking function (IWF) capability.
Table 1-1 Supported LT Boards
LT Board PhysicalInterfaces
Overlay Density NT Interface IWF
NELT-B Ethernet - 36 10 GE L3 (2)
(1 of 2)
NT
NTIO
2 -
EPS
EMAN
IWF Transport
LTcontrol
n
Ethernet CPE
LT
Network links |Subtending links |
User links
Systemcontrol
IHubcontrol
IHubrouter GPON ONT
EPON ONT
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-93HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Notes(1) L2: IWF function capability on Layer 2. For an overview of the IWF capabilities, refer to section 1.5(2) L3: IWF function capability on Layer 2 and Layer 3. For an overview of the IWF capabilities, refer
to section 1.5(3) Not all L3 features are supported in these ports, see Table 1-13
GFC Board
The General Facilities Card (GFC) provides connections for external power, circuit breakers for system protection, visual indications for power availability and collection and cascading of external alarms.
NTIO Board
The NTIO board plays the role of an applique to either the single NT board, or to both NT boards, depending on the NT redundancy configuration. It allows to decouple NT equipment protection from up-link protection in case of a redundant NT pair. In case the active NT fails, traffic on the NTIO external links will be switched automatically to and from the stand-by NT.
Table 1-2 shows the supported NT I/O boards.
Table 1-2 NT I/O Boards
NGLT-A GPON - 8 10 GE L3 (2)(3)
FPLT-A EPON - 8 10 GE L2(1)
Note — These boards are only used on the FX-8 and FX-4 subracks.
Board Interfaces
FNIO-B Eight additional external Ethernet interfaces:
• eight optical 100/1000Base-FX
Eight additional external Ethernet interfaces:
• four optical 100/1000Base-FX• four combo uplink ports, which can be configured to optical uplink ports (SFP ports,
100Base-FX, 1000Base-FX) or electrical uplink ports ( RJ45, 10/100/1000BASE-T)
LT Board PhysicalInterfaces
Overlay Density NT Interface IWF
(2 of 2)
1 — System Overview
1-10 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Port mapping
The tables below list the port mapping for 7360 ISAM FX, that is, the mapping between the logical port numbers as used in the ISAM and the physical port numbers as visible on the equipment itself (frontplate numbering).
• Table 1-3 lists the different mapped items.• Table 1-4 lists the port mapping for the FANT-F board in a 7360 ISAM FX-16
subrack.• Table 1-5 lists the port mapping for the FANT-F board in a 7360 ISAM FX-16 in
dual NT + NTIO subrack mode for FNIO-B.• Table 1-6 lists the port mapping for the FANT-F board in a 7360 ISAM FX-8
subrack.• Table 1-7 lists the port mapping for the FANT-F board in a 7360 ISAM FX-8 in
dual NT + NTIO subrack mode for FNIO-B.• Table 1-8 lists the port mapping for the FANT-F board in a 7360 ISAM FX-4
subrack.• Table 1-9 lists the port mapping for the FANT-F board in a 7360 ISAM FX-4 in
dual NT + NTIO subrack mode for FNIO-B.
Table 1-3 Mapped Items
Table 1-4 FANT-F in 7360 ISAM FX-16
Item Description
Physical Port Number The physical switch device port number.
Logical Port Number The port number as denoted in the SNMP management interface
LT port number (index based)
For internal LT ports, the index of the LT in the main subrack that corresponds to this port (for local LTs only)
Faceplate port number For external ports, the manner in which this port is identified at the faceplate of the board.
Port state / configurability For NTIO ports, the manner in which this port can be configured:
• UP for uplinks/subtending/user links• DOWN for internal LT links
and
• FIXED for fixed configuration (UP or DOWN)• CONF for configurable configuration (UP or DOWN)
Physical PortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface
10 15 1
12 16 2
16 17 3
18 18 4
(1 of 2)
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-113HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Table 1-5 FANT-F + FNIO-B in 7360 ISAM FX-16
32 19 5
34 20 6
41 21 7
43 22 8
45 23 9
37 24 10
22 25 11
8 26 12
39 27 13
28 28 14
20 29 15
14 30 16
2 5 1 (NT-A) RJ45
4 6 X1 (NT-A) SFP+
5 7 X2 (NT-A) SFP+
6 8 X3 (NT-A) SFP+
7 9 X4 (NT-A) SFP+
3 3 IEEE1588 (NT-A)
2 10 1 (NT-B) RJ45
4 11 X1 (NT-B) SFP+
5 12 X2 (NT-B) SFP+
6 13 X3 (NT-B) SFP+
7 14 X4 (NT-B) SFP+
3 4 IEEE1588 (NT-B)
Physical PortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface
(2 of 2)
PhysicalPortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface FNIO-B
FaceplatePortNumber
Port State /Configurability
10 15 1
12 16 2
16 17 3
18 18 4
(1 of 2)
1 — System Overview
1-12 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
32 19 5
34 20 6
41 21 7
43 22 8
45 23 9
37 24 10
22 25 11
8 26 12
39 27 13
28 28 14
20 29 15
14 30 16
47 31 as on NTIO SFP 1 (SFP) UP, FIXED
48 32 as on NTIO SFP 2 (SFP) UP, FIXED
51 33 as on NTIO SFP 3 (SFP) UP, FIXED
52 34 as on NTIO SFP 4 (SFP) UP, FIXED
30 35 as on NTIO SFP or RJ45 5 (Combo) UP, FIXED
31 36 as on NTIO SFP or RJ45 6 (Combo) UP, FIXED
49 37 as on NTIO SFP or RJ45 7 (Combo) UP, FIXED
50 38 as on NTIO SFP or RJ45 8 (Combo) UP, FIXED
2 5 1 (NT-A) RJ45
4 6 X1 (NT-A) SFP+
5 7 X2 (NT-A) SFP+
6 8 X3 (NT-A) SFP+
7 9 X4 (NT-A) SFP+
3 3 IEEE1588 (NT-A)
2 10 1 (NT-B) RJ45
4 11 X1 (NT-B) SFP+
5 12 X2 (NT-B) SFP+
6 13 X3 (NT-B) SFP+
7 14 X4 (NT-B) SFP+
3 4 IEEE1588 (NT-B)
PhysicalPortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface FNIO-B
FaceplatePortNumber
Port State /Configurability
(2 of 2)
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-133HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Table 1-6 FANT-F in 7360 ISAM FX-8
Table 1-7 FANT-F + FNIO-B in 7360 ISAM FX-8
Physical PortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface
59 15 1
47 16 2
28 17 3
8 18 4
51 19 5
36 20 6
24 21 7
16 22 8
2 5 1 (NT-A) RJ45
4 6 X1 (NT-A) SFP+
5 7 X2 (NT-A) SFP+
6 8 X3 (NT-A) SFP+
7 9 X4 (NT-A) SFP+
3 3 IEEE1588 (NT-A)
2 10 1 (NT-B) RJ45
4 11 X1 (NT-B) SFP+
5 12 X2 (NT-B) SFP+
6 13 X3 (NT-B) SFP+
7 14 X4 (NT-B) SFP+
3 4 IEEE1588 (NT-B)
PhysicalPortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface FNIO-B
FaceplatePortNumber
Port State /Configurability
59 15 1
47 16 2
28 17 3
8 18 4
51 19 5
36 20 6
(1 of 2)
1 — System Overview
1-14 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Table 1-8 FANT-F in 7360 ISAM FX-4
24 21 7
16 22 8
63 23 as on NTIO SFP 1 (SFP) UP, FIXED
64 24 as on NTIO SFP 2 (SFP) UP, FIXED
14 25 as on NTIO SFP 3 (SFP) UP, FIXED
15 26 as on NTIO SFP 4 (SFP) UP, FIXED
40 27 as on NTIO SFP or RJ45 5 (Combo) UP, FIXED
41 28 as on NTIO SFP or RJ45 6 (Combo) UP, FIXED
12 29 as on NTIO SFP or RJ45 7 (Combo) UP, FIXED
13 30 as on NTIO SFP or RJ45 8 (Combo) UP, FIXED
2 5 1 (NT-A) RJ45
4 6 X1 (NT-A) SFP+
5 7 X2 (NT-A) SFP+
6 8 X3 (NT-A) SFP+
7 9 X4 (NT-A) SFP+
3 3 IEEE1588 (NT-A)
2 10 1 (NT-B) RJ45
4 11 X1 (NT-B) SFP+
5 12 X2 (NT-B) SFP+
6 13 X3 (NT-B) SFP+
7 14 X4 (NT-B) SFP+
3 4 IEEE1588 (NT-B)
PhysicalPortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface FNIO-B
FaceplatePortNumber
Port State /Configurability
(2 of 2)
Physical PortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface
27 15 1
23 16 2
12 17 3
8 18 4
2 5 1 (NT-A) RJ45
4 6 X1 (NT-A) SFP+
(1 of 2)
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-153HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Table 1-9 FANT-F + FNIO-B in 7360 ISAM FX-4
5 7 X2 (NT-A) SFP+
6 8 X3 (NT-A) SFP+
7 9 X4 (NT-A) SFP+
3 3 IEEE1588 (NT-A)
2 10 1 (NT-B) RJ45
4 11 X1 (NT-B) SFP+
5 12 X2 (NT-B) SFP+
6 13 X3 (NT-B) SFP+
7 14 X4 (NT-B) SFP+
3 4 IEEE1588 (NT-B)
Physical PortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface
(2 of 2)
PhysicalPortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface FNIO-B
FaceplatePortNumber
Port State /Configurability
27 15 1
23 16 2
12 17 3
8 18 4
31 19 as on NTIO SFP 1 (SFP) UP, FIXED
32 20 as on NTIO SFP 2 (SFP) UP, FIXED
35 21 as on NTIO SFP 3 (SFP) UP, FIXED
36 22 as on NTIO SFP 4 (SFP) UP, FIXED
20 23 as on NTIO SFP or RJ45 5 (Combo) UP, FIXED
21 24 as on NTIO SFP or RJ45 6 (Combo) UP, FIXED
33 25 as on NTIO SFP or RJ45 7 (Combo) UP, FIXED
34 26 as on NTIO SFP or RJ45 8 (Combo) UP, FIXED
2 5 1 (NT-A) RJ45
4 6 X1 (NT-A) SFP+
5 7 X2 (NT-A) SFP+
6 8 X3 (NT-A) SFP+
7 9 X4 (NT-A) SFP+
3 3 IEEE1588 (NT-A)
(1 of 2)
1 — System Overview
1-16 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
IHub
The IHub provides L2 bridging (based on VPLS) and IP routing (based on VPRN). It has at least 28 ports with a various specialization:
A number of ports are used to make a connection at 1 Gbps or at 2.5 Gbps or at 10 Gbps to an LT local in the shelf (one IHub link per LT). The actual connection speed depends on the LT capabilities; see Table 1-1.
The FE/GE ports, which are not used for connecting LT boards (local or remote), and the 10GE ports, are available as network interfaces, as interfaces to subtended DSLAM systems, or for connecting directly to users. These links serve network links, subtending links, or user links respectively.
Use of these ports is possible either through:
• Link interfaces which are physically located on an NTIO board, connected via bi-directional point-to-point high-speed tracks on the back-panel to both NT boards.These interfaces can also be used as electrical FE, electrical GE or optical GE, optical 10GE interfaces, for uplink, subtending or user links (depending on the NTIO board capabilities and software support). The NTIO board contains an NT equipment protection switch per external link interface.So link protection and NT equipment protection can be performed independently from each other for links terminated on the NTIO.
• Link interfaces that are physically located on the NT board itself, as electrical FE interfaces, electrical GE interfaces, optical GE interfaces, and optical 10 GE interfaces, for uplink, subtending or user links.
2 10 1 (NT-B) RJ45
4 11 X1 (NT-B) SFP+
5 12 X2 (NT-B) SFP+
6 13 X3 (NT-B) SFP+
7 14 X4 (NT-B) SFP+
3 4 IEEE1588 (NT-B)
PhysicalPortNumber
Logical PortNumber
LT SlotNumber(indexbased)
FaceplatePortNumber
Interface FNIO-B
FaceplatePortNumber
Port State /Configurability
(2 of 2)
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-173HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1.3 Network Management
Figure 1-9 shows how the 7360 ISAM FX can be managed in a network.
Figure 1-9 7360 ISAM FX Network Management
The remote Craft Terminal (CT) uses TL1 commands or Command Line Interface (CLI) commands. TL1 is used for pre-provisioning of the NT board. CLI is used to manage both the xHub subsystem and the IACM.
Figure 1-10 shows the management topology for the 7360 ISAM FX.
Figure 1-10 7360 ISAM FX Management Topology
The NT Controller and the xHub subsystem each contain a separate SNMP agent. These can be managed via an Element Management Station (EMS), such as the Alcatel-Lucent 5520 AMS.
It is also possible to use local TL1 or CLI craft terminal on the NT board to manage the LTs.
LIM
LIM
LIM
EMAN
EMS CT
RS232
Network Ports
Remote CT
Management Flow to cascaded ISAM
ISAM
IACM
xHub
CLI (via Telnet)TL1 (via UDP-login)
ISAM
CLIagent
TL1agent
SNMPagent
RS232RS232 SSH TelnetUDPSNMPv2
orSNMPv3
Debugagent
SSH UDP
EMS(e.g. AMS 5520)
TL1Gateway
CLITerminal
TL1CT
CLICT
TL1Terminal
DebugTerminal
Telnet
1 — System Overview
1-18 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
An integrated CLI approach is implemented on the NT board using an CLI agent. This agent implements CLI commands for the NT Controller / LIMs and the xHub subsystem. However, there is no semantic integration.
Table 1-10 shows an overview of the involved managers.
Table 1-10 Manager Overview
1.4 Equipment Management
The NE equipment practice type does not have to be explicitly planned by the operator, but is auto-planned by the NT at startup, depending on the detected type. At the same time, the NT will autoplan the maximum number of racks supported by this equipment practice. The following ISAM type is defined:
• LNWW: Large New Equipment Practise Worldwide market (6 racks, 4 subracks per rack)
Subracks are automatically planned upon detection. The operator can control the administrative state of a subrack (lock/unlock).
The NE manages different types of boards. A complete overview of all supported board types in each type of subrack is given in the chapter “Subracks”. Board planning is supported for all types of boards, including the appliques. For LSMs, the operator can control the administrative state (lock/unlock).
Central Office Equipment managementCentral Office equipment only supports configurations consisting of a single rack/subrack.
ONT ManagementFor more information on the ONT management, see the System Description for FD 100/320Gbps NT and FX NT document.
Type Description
EMS Element Management System (EMS) based on SNMP. The Alcatel-Lucent WorkStation (5520 AMS) is commonly used.
CT Craft Terminal using TL1 commands or Command Line Interface (CLI) commands.
Note 1 — External OAM VLAN:
The IHub subsystem supports in-band management. This happens through a dedicated VLAN, which must be configured (if different than 4093) on both the IHub subsystem as on the NT.
Note 2 — VLAN 4094 and VLAN range 4088 and 4092 are reserved for internal use.
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-193HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1.5 Board Capabilities and Dimensioning
This section provides an overview of:
• dimensioning information for the NT boards; see Table 1-11• SyncE support on NT boards and NTIO boards; see Table 1-12• the IWF capabilities of the LT boards per forwarding type; see Table 1-13• Ethernet frame size; see Table 1-14• dimensioning information of the LT boards per forwarding type; see Table 1-15• GPON-specific dimensioning; see Table 1-16• EPON-specific dimensioning; see Table 1-17
NT Board DimensioningTable 1-11 shows the dimensioning for the different NT board and their variants.
Table 1-11 NT Board Dimensioning
Note(1) A number of MAC addresses are always used by the system for internal purposes.(2) The same resource is shared for L2 filters and L3 filters. So, the maximum cannot be obtained for
both at the same time.
Description FANT-F AC
Throughput 480 Gbps
Maximum number of MAC addresses (FDB)(1)
128 k
Maximum number of IP interfaces 512
ARP table size 16 k
Maximum number of IP routes:
FIB
RIB
16 k
16 k
Maximum number of L2 filters 512(2)
Maximum number of L3 filters 512
Maximum number of VLAN 4 k
Maximum number of cross-connect
4 k
L2 frame size (in bytes) 480 Gbps
External interfaces 1 x El. GE
4 x 1/10 GE
BITS in/out ports 1/1
SyncE input/output 4/4
1 — System Overview
1-20 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
SyncE SupportTable 1-12 indicates the port applicability of the Synchronous Ethernet NTR functionality for clock extraction (in) and generation (out).
Table 1-12 Faceplate port applicability for Synchronous Ethernet
Board Port SyncE In Support SyncE Out Support
FANT-F X1 1GE and 10GE 1GE and 10GE
X2 1GE and 10GE 1GE and 10GE
X3 1GE and 10GE 1GE and 10GE
X4 1GE and 10GE 1GE and 10GE
FNIO-B 1 - 1GE
2 - 1GE
3 - 1GE
4 - 1GE
5 - 1GE
6 - 1GE
7 - 1GE
8 - 1GE
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-213HH-10116-AAAA-TCZZA Edition 01 Released Product Information
IWF CapabilitiesTable 1-13 provides an overview of the IWF capabilities of the LT boards. Refer to Table 1-1 for an overview of the supported LT boards.
Table 1-13 IWF Capabilities
Feature L3 L3GPON
L3EPON
NELT-B
UNI NNI
ATM AAL5 encapsulation type
LLC/SNAP bridged (IPoE and PPPoE) Y - - - -
LLC/SNAP routed (IPoA) Y - - - -
LLC/NLPid (PPPoA) Y - - - -
VC Mux Bridged (IPoE and PPPoE) Y - - - -
VC Mux Routed (IPoA) Y - - - -
VC Mux PPPoA (PPPoA) Y - - - -
Encapsulation autodetect
Autodetect IP (between LLC/SNAP bridged and routed) Y - - - -
Autodetect PPP (between LLC/SNAP bridged, VC Mux Bridged and LLC-NLPID, VC Mux PPPoA)
Y - - - -
Autodetect IP+PPP Y - - - -
Autodetect PPPoA (between LLC-NLPID and VC Mux PPPoA)
Y - - - -
Bridged Encapsulation Ethernet Packet formats
Reception of untagged packets Y Y - Y Y
Reception of combination of untagged and priority tagged packets
Y Y - Y Y
Reception of single tagged packets Y Y Y Y Y
Reception of combination of untagged, priority tagged, single tagged packets
Y Y - Y Y
Packet processing
Port Based Default VLAN for untagged / priority tagged (if applicable) packets
Y Y - Y Y
Port and Protocol Based default VLAN for untagged / priority tagged packets of the IpoE Protocols
Y Y - Y Y
Port and Protocol Based default VLAN for untagged / priority tagged packets of the PPPoE Protocols
Y Y - Y Y
Priority Bit Remarking and Mapping table for tagged / priority tagged packets
Y Y Y Y Y
L2 Forwarding
RB mode: Protocol Filter (set of Ethertypes) for upstream traffic in VLANs in (PPPoE and IpoE)
Y Y Y Y Y
RB mode Ethernet packet types: Ethernet II Encap on Ethernet
Y Y Y Y Y
(1 of 2)
1 — System Overview
1-22 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Note(1) ARP relay only(2) Support policing on bridge port on L2
Ethernet Frame SizeTable 1-14 indicates the supported Ethernet frame size for the different line boards..
RB mode Ethernet packet types: LLC/SNAP on Ethernet Y Y Y Y Y
CC Mode: transparently pass all encapsulations (e.g. PPPoE and IpoE)
Y Y Y Y Y
CC Mode: Protocol Filter Y Y - Y -
CC Mode: IPoA to IPoE CC Y - - - -
VLAN stacking (S-VLAN CC and S-VLAN / C-VLAN CC) Y Y Y Y Y
VLAN stacking (S-VLAN / C-VLAN Residential Bridge) - - Y - Y
QoS-aware CC Y - - - -
L2 Forwarding user access protocols
ARP: enabling/disabling broadcast Y Y Y Y -
802.1X authentication Y Y - Y -
DHCP option 82 insertion Y Y Y Y -
PPPoE relay tag Y Y Y Y -
PPPoA-PPPoE relay Y - - - -
Multicast services Y Y Y Y -
L3 Forwarding
IPoE Y Y - Y -
IPoA Y Y - Y -
VLAN termination (at network side), forwarding at Layer 3
Y Y - Y Y
L3 Forwarding user access protocols
802.1X authentication Y - - Y -
ARP proxy user side for IPoE Y Y Y(1) Y -
DHCP relay Y - - Y -
QoS
CAC profile Y Y Y Y Y
Association of QOS profiles to ports Y(2) Y - Y Y
Association of QOS profiles to port-VLAN associations Y Y Y Y -
Feature L3 L3GPON
L3EPON
NELT-B
UNI NNI
(2 of 2)
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-233HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Table 1-14 Ethernet Frame Size for different LT boards
Dimensioning of the LT BoardsTable 1-15 provides dimensioning information of the LT boards. Refer to Table 1-1 for an overview of the supported LT boards.
Table 1-15 Dimensioning Information
LT Board Encapsulation Frame Size (bytes)
P2P Eth NELT-B UNI (with FCS) 1976
NELT-B NNI (with FCS) 2048
OLT NGLT-A (with FCS) 2000
OLT FPLT-A (with FCS) 2000
Feature L3 L3GPON
L3EPON
NELT-B
UNI NNI
General
Maximum number of PONs - 8 8 - -
Maximum number of UNIs - 4096 4096 - -
Maximum number of FE ports per board - - - 36 36
Maximum number of GE ports per board - - - 36 36
Maximum number of UNI port type (FE) per board - - - 36 -
Maximum number of UNI port type (GE) per board - - - 36 -
Maximum number of NNI port type (FE) per board - - - - 36
Maximum number of NNI port type (GE) per board - - - - 36
Maximum number of CC VLAN 768 11520 7680 4608 4608
Maximum number of RB VLAN 768 1296 1296 1296 1296
Maximum number of VLAN per PVC 16 8 768 - -
Maximum number of port-VLAN associations per LT 384 11520 11776 - -
Maximum number of VLAN port per UNI (FE/GE) - - - 8 -
Maximum number of VLAN port per NNI (FE/GE) - - - - 256
Maximum number of VLAN port per board (UNI) - - - 144 -
Maximum number of VLAN port per board (NNI) - - - - 4608
Maximum number of MAC addresses per VLAN port 64 64 8192 - -
Maximum number of MAC addresses per UNI - - - 64 -
Maximum number of MAC addresses per NNI - - - - 3072
Maximum number of MAC addresses per board (including static)
1024 16 K(2) 16 K 2304 32768
(1 of 2)
1 — System Overview
1-24 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Notes(1) Due to thermal restrictions(2) A few MAC addresses are used by the system for internal purposes.
ISAM OLT Service and System Capacity
Service and system capacity
Table 1-16 provides specific dimensioning information of the GPON LT boards.
Table 1-16 GPON-specific Dimensioning Information
Maximum number of user IP addresses per board (including static)
384 8 K 7680 - -
Average number of IPv4 subnets or addresses per board (=Average IP anti-spoofing entries, full/32 IP address or subnet, per board
- - - 288 0
Maximum number of IPv4 hosts per board - - - 288 0
Maximum number of IPv6 subnets or addresses per UNI
- - - 16 0
Maximum number of IPv6 subnets or addresses per VLAN port
- - - 4 0
Maximum number of IPv6 host addresses per board - - - 288 0
Maximum number of VRFs per board 128 NA NA - -
Multicast Dimensioning
Maximum number of simultaneous multicast channels per board
1024 1024 1024 1024 1024
Maximum number of multicast groups per user 100 100 100 100 1024
Maximum number of multicast VLANs 128 128 64 - -
802.1x
Maximum number of 802.1x sessions per PON - 288 - - -
Maximum number of 802.1x sessions per UNI - - - 1 -
Maximum number of 802.1x sessions per board - 2304 - 36 -
Feature L3 L3GPON
L3EPON
NELT-B
UNI NNI
(2 of 2)
Feature L3 GPON
Maximum number of ONT per PON 128
Maximum number of UNIs per PON 512
Maximum number of TCONTs per PON 1024
Maximum number of GEM ports per PON 2048
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-253HH-10116-AAAA-TCZZA Edition 01 Released Product Information
ISAM OLT performance and distance
The ISAM OLT provides performance and distance capacity of 2.488 Gb/s downstream and 1.244 Gb/s upstream, within a 40 km span, for all NGLT boards. The optical link budget is defined by both loss and bandwidth characteristics. The loss characteristic is determined by the difference between the optical transmitter and optical receiver for each direction, and is typically 28 dB. The bandwidth characteristic is determined by the maximum link distance parameter of each OLT and ONT transmitter specification, and is limited by the smaller of the upstream and downstream values.
ISAM OLT connection capacities
The ISAM OLT can accommodate a maximum of 16 NGLT boards. Each NGLT board provides eight ports.
EPON Service and System CapacityTable 1-17 provides specific dimensioning information of the EPON LT boards.
Table 1-17 EPON-specific Dimensioning Information
1.6 NT Redundancy Support
Four levels of redundancy can be identified:
• Link redundancy• Equipment redundancy• Subscriber Line redundancy• Application redundancy
NT redundancy will implement the Link Redundancy and Equipment Redundancy in a decoupled architecture. This results in the following redundancy cases:
• Only link protection:single NT, active-standby or load-sharing uplinks.
• Combined NT and link protection, no NTIO:dual active/standby NT, with direct uplink or link set.
Feature L3 EPON
Maximum number of ONT per PON 64
Maximum number of ONT per EPON LT board 512
Maximum number of ONTs per system 8192
Maximum number of LLIDs per ONT 1
Maximum number of UNIs per PON 512
Maximum number of UNIs per LT board 4096
Maximum number of UNIs per system 26214
1 — System Overview
1-26 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
• Decoupled NT and link protection, single NTIO:dual active/standby NT, NTIO board with link switches.
• NT protection, passive link protection, no NTIO:single, active-standby or load sharing uplinks.
• Subtending system protection.
Table 1-18 shows which hardware modules are ready for NT redundancy support.
Table 1-18 NT Redundancy Support Ready Hardware Modules
1.7 CLEI Codes
Table 1-19 lists the boards and fan units for which CLEI codes are available.
Table 1-19 CLEI codes
Type Module
Subrack FX-16
FX-8
FX-4
NT boards FANT-F
NTIO boards FNIO-B
LT boards FPLT-A
NELT-B
NGLT-A
Caution — The CLEI code changes whenever an item change (that is, an adaptation to a board) occurs.
The latest status of these CLEI codes is always available on the following website:
https://codecenter.commonlanguage.com/applogin.asp?app=clei_inquiry
An account is required before the CLEI database can be accessed.
Mnemonic Variant CLEI code CPR Bar code
AFAN-H 3EC 37533 NB VAUCAE2KAA 070LXX 154967
FANT-F 3FE 53701 AC VAUKAKG6AA 072BWS 179981
FNIO-B 3FE 54057 AA VAI2AHNNAA 072CUP 181294
NELT-B 3FE 62543 AA VAUCAJ36AA 072AEY 177909
NGLT-A 3FE 64279 AA VAI2AFHDAA 070YVT 175498
(1 of 2)
1 — System Overview
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 1-273HH-10116-AAAA-TCZZA Edition 01 Released Product Information
NFXS-E 3FE 64936 AA VAM9F10DRA 214460 462367
NGFC-E 3FE 64985 AA VAUCAJ76AA 072AXH 178685
NFXS-F 3FE 64991 AA VAMVV10KRA 214392 462173
NGFC-F 3FE 64993 AA VAUCAJ66AA 072ARH 178373
AFAN-X 3FE 64994 AA VAUCAJ56AA 072ARC 178361
AFAN-E 3FE 65060 AA VAUCAJ86AA 072AXJ 178692
NFXS-D 3FE 65209 AA VAM9G10DRA 214458 462357
Mnemonic Variant CLEI code CPR Bar code
(2 of 2)
1 — System Overview
1-28 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 2-13HH-10116-AAAA-TCZZA Edition 01 Released Product Information
2 — Subracks
2.1 Introduction 2-2
2.2 General 2-2
2.3 7360 ISAM FX Subracks 2-2
2.4 Supported Plug-in Units 2-6
2.5 Dummy Front Panels 2-7
2 — Subracks
2-2 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
2.1 Introduction
This chapter describes the different 7360 ISAM FX subracks supported for the European Telecommunication Standard Institute (ETSI) market.
2.2 General
The modular organization of the ISAM system allows a wide range of physical size and traffic capacity options.The basic building blocks of the ISAM system are the subracks or shelves(*).(*): Both names are used for the same item.The ISAM R 4.x is a one-subrack system. Daisy-chaining multiple subracks via extender boards is not supported.Multiple collocated subracks can be cascaded via the standard Fast Ethernet (FE)/Gigabit Ethernet (GE)/10Gigabit Ethernet (10GE) subtending links. In such a configuration, each subrack operates and is managed as a separate system.
2.3 7360 ISAM FX Subracks
Subrack Types
Table 2-1 lists the 7360 ISAM FX subracks supported in this release.
Table 2-1 7360 ISAM FX Subracks
Notes(1) Adapter brackets must be used
• Figure 2-1 shows the 7360 ISAM FX-16 subrack• Figure 2-2 shows the 7360 ISAM FX-8 subrack• Figure 2-3 shows the 7360 ISAM FX-4 subrack
Item 7360 ISAM FX Subracks
FX-16 FX-8 FX-4
Code 3FE 65209 AA 3FE64936 AA 3FE-64991 AA
Mnemonic NFXS-D NFXS-E NFXS-F
Dimensions (in mm) Width 529 482.5 482.5
Height 622.5 355 222
Depth max. 280 278.3 278.3
Can be mounted in: ETSI racks Y Y(1) Y(1)
19” racks N Y Y
2 — Subracks
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 2-33HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Figure 2-1 7360 ISAM FX-16 Subrack
Figure 2-2 7360 ISAM FX-8 Subrack
Figure 2-3 7360 ISAM FX-4 Subrack
2 — Subracks
2-4 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Subrack Configurations
Table 2-2 lists the possible subrack configurations.
Table 2-2 Subrack Configurations
The following figures show the general layout and the slot numbering for the different 7360 ISAM FX subracks:
• for a 7360 ISAM FX-16 subrack in LT mode; see Figure 2-4• for a 7360 ISAM FX-8 subrack; see Figure 2-5• for a 7360 ISAM FX-4 subrack; see Figure 2-6
Figure 2-4 7360 ISAM FX-16 subrack
Configuration 7360 FX-16 7360 FX-8 7360 FX-4
Maximum number of LT boards 16 8 4
Fan unit
CBs, LEDs and switches
Connectors
NT
A
NT
IO
NT
B
LT 8
LT 3
LT 9
LT 1
3
LT 4
LT 7
LT 1
2
LT 1
LT 2
LT 5
LT 6
LT 1
0
LT 1
1
LT 1
4
LT 1
5
LT 1
6
2 — Subracks
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 2-53HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Figure 2-5 7360 ISAM FX-8 subrack
Figure 2-6 7360 ISAM FX-4 subrack
NT RedundancyThe protection scheme for NT redundancy is 1+1 (active/active) in the data plane, and 1:1 (active/standby) in the control and management plane.
Fan UnitOne fan unit provides forced air cooling in the subrack.
The fan unit is a field replaceable unit in the subrack fan area, it plugs directly into the backplane. The fan unit can be equipped with a dust filter.
LT 7
LT 6
LT 5
LT 4
LT 3
LT 2
LT 1
NT A
NT I/O
NT B
NGFC-E
FAN
LT 8
LT 4
LT 3
LT 2
LT 1
NT A
NT I/O
NT B
NGFC-F
FAN
2 — Subracks
2-6 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
2.4 Supported Plug-in Units
Table 2-3 lists the supported plug-in units in the 7360 FX subracks for the current release.
Table 2-3 Supported Units in 7360 FX Subracks
Slot Plug-in Unit Description
NT A FANT-F AC 480 Gbps NT board
NT B FANT-F AC 480 Gbps NT board
NTIO FNIO-B NT I/O board with 8 supplementary uplinks
LT slot NELT-B 36-line Ethernet (FE/GE) LT board
NGLT-A GPON LT board with 8 GPON interfaces
FPLT-A EPON LT board with 8 EPON interfaces
General facilities board NGFC-E General facilities and control board for FX-8 subrack
NGFC-F General facilities and control board for FX-4 subrack
Fan area AFAN-H NB Fan unit for FX-16 subrack
AFAN-E Fan unit for FX-8 subrack
AFAN-X Fan unit for FX-4 subrack
Note — For detailed information about the plug-in units, refer to the relevant UDS. The used mnemonics are explained in Appendix “Board Mnemonics”.
2 — Subracks
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 2-73HH-10116-AAAA-TCZZA Edition 01 Released Product Information
2.5 Dummy Front Panels
Dummy front panels must be mounted on any unused slot of a subrack for the following purposes:
• To ensure EMC compliance• To ensure thermal compliance via a correct airflow in the subrack• To ensure safety by avoiding direct contact with backplane connectors• At slot deployment, the dummy front plate is replaced by the appropriate board
and the cables are connected to the board.
For NT BoardThis panel (code 3FE 65651 AA) must be used when the second NT board is not installed. Figure 2-7 shows the dummy front panel for NT board.
Figure 2-7 Dummy Front Panel for NT Board
For Optical BoardsWhen optical cabling is already foreseen for not-installed optical LT boards (NGLT-A, FPLT-A), the optical cables must be fixed on dummy front panels (code 3FE 65005 AA). Figure 2-8 shows the dummy front panel.
2 — Subracks
2-8 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Figure 2-8 Dummy Front Panel for Optical LT boards
Dust cap
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3-13HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3 — Physical Rack Equipment
3.1 General 3-2
3.2 Universal Rack 3-2
3.3 Side Plates 3-5
3.4 Rack Doors 3-6
3.5 Key Locks 3-7
3 — Physical Rack Equipment
3-2 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
3.1 General
The rack equipment can be delivered as a preassembled rack or in separate kits.
This rack assembly is a universal rack cabinet, dimensions 2200 mm x 600 mm x 300 mm, which can be equipped with subracks, accompanying fan units and power and alarm cabling. Each rack configuration is ordered with a specific ordering code.
Different parts can also be delivered separately or in kits, the assembly is done on site at the customer.
3.2 Universal Rack
Cabinet Types
Table 3-1 shows the specifications of the universal rack.
Table 3-1 Cabinet Type used for FX Equipment
Figure 3-1 Universal Rack
Type Code Height Floorspace Drawing
Universal 3FE 28688 AA 2200 mm 600 x 300 mm Figure 3-1
3 — Physical Rack Equipment
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3-33HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Transport Bracket
The transport bracket is mounted on the universal rack to protect the door from damage during transport.
Figure 3-2 Transport Bracket
On site the bracket must be removed.
Cabling SpaceAs shown in Figure 3-1, the universal cabinet provides the space required for cabling. Position and dimensions of side holes are adapted for routing cables of all subracks in any configuration.
If required, the bottom plate can be removed as shown in Figure 3-3, to free bottom holes that allow cable routing under raised floor.
Transportbracket
3 — Physical Rack Equipment
3-4 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Figure 3-3 Top and inside Bottom View
Top view
Bottom view inside cabinet
Floor plate mounted Floor plate removed(cable routing via bottom holes)
3 — Physical Rack Equipment
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3-53HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3.3 Side Plates
Table 3-2 specifies the items which are required to equip a universal rack with side plates (left or right).
Table 3-2 Side Plate Fixing Items
The same kit is used for mounting a side plate on the left or on the right. Figure 3-4 shows the right side plate.
Figure 3-4 Mounting Side Plate on Universal Rack
When mounting or dismounting the side plate, always remove the corner upright (item 4 in Figure 3-4) first. Each side plate is mounted with 5 screws and washers on the front and 5 screws and washers on the side.
Description Quantity Item No. on Figure 3-4
Side plate 2 1
Screw M4 20 2
Washer M4 20 3
3 — Physical Rack Equipment
3-6 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
3.4 Rack Doors
One universal door is available (code 3FE 20207 JC). The door opens to the left and can be closed by means of two door latch locks.
Figure 3-5 Universal Rack with Right Side Door
Refer to the 7360 ISAM FX Hardware Installation Manual for installation procedure.
3 — Physical Rack Equipment
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3-73HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3.5 Key Locks
The door latch locks can be replaced on site by key locks. A key lock kit can be ordered separately (code 3FE 25800 AA). This kit contains two key locks, two keys and instructions to replace the standard latch locks by key locks.
Figure 3-6 Key Lock Kit
Refer to the 7360 ISAM FX Hardware Installation Manual for installation procedure.
3 — Physical Rack Equipment
3-8 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 4-13HH-10116-AAAA-TCZZA Edition 01 Released Product Information
4 — Rack Configurations
4.1 General 4-2
4.2 Rack Configurations 4-2
4 — Rack Configurations
4-2 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
4.1 General
This chapter describes the supported rack configurations for the 7360 ISAM FX-16 subrack.
An rack contains:
• A rack cabinet: 2200 mm high.• A door opening/closing on the left or the right side with a handle or a lock.• One or two subrack(s) depending on the rack configuration.• One fan unit per equipped subrack, for equipment cooling.
4.2 Rack Configurations
Table 4-1 gives an overview of all the possible rack configurations with 7360 ISAM FX-16 subracks. These configurations are shown in Figure 4-1.
Table 4-1 Rack Configurations with 7360 ISAM FX-16 subracks
Code 3FE 65679 AA 3FE 65680 AA
Cabinet 3FE 28688 AA
SR 1 NFXS-D
(3FE 65209 AA)
NFXS-D
(3FE 65209 AA)
Fan1 AFAN-H(with dust filter)
(3EC 37533 NB)
AFAN-H(with dust filter)
(3EC 37533 NB)
SR 2 - NFXS-D
(3FE 65209 AA)
Fan 2 - AFAN-H(with dust filter)
(3EC 37533 NB)
4 — Rack Configurations
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 4-33HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Figure 4-1 Rack Configurations with 7360 ISAM FX-16 subracks
3FE 65679 AA 3FE 65680 AA
4 — Rack Configurations
4-4 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 5-13HH-10116-AAAA-TCZZA Edition 01 Released Product Information
5 — SFP Optical Modules
5.1 Introduction 5-2
5.2 SFP Optical Modules 5-2
5 — SFP Optical Modules
5-2 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
5.1 Introduction
This section lists the Alcatel-Lucent-approved Small Form Pluggable (SFP) modules that are supported for each board type.
5.2 SFP Optical Modules
Table 5-1 lists the Alcatel-Lucent-approved Small Form Pluggable (SFP) optical modules that are supported for each board type.
Table 5-2 lists different characteristics of these SFP modules.
Table 5-1 Supported SFP Modules per Board Type
Code Description
FA
NT
-F
FN
IO-B
NEL
T-B
NG
LT-A
FPLT
-A
Fast Ethernet SFP
3FE 25777 AA FE-FX Y
3FE 25778 AA FE-LX10 Y
3FE 29194 AA FE BX-10-D Y
3FE 29194 BA FE BX-10-D Y
3FE 29195 AA FE BX-10-U Y
3FE 63343 AA 100Base-T Y
Gigabit Ethernet SFP
3FE 25773 AA GE-SX
3FE 25774 AA GE-LX Y Y
3FE 25775 AA GE-EX Y
3FE 25776 AA GE-ZX Y
3FE 25771 AA GE-YX CWDM (24 dB)
3FE 25771 AB
3FE 25771 AC
3FE 25771 AD
3FE 25771 AE
3FE 25771 AF
3FE 25771 AG
3FE 25771 AH
(1 of 2)
5 — SFP Optical Modules
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 5-33HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Notes(1) This is a dual-rate compact SFP
3FE 25771 CA GE-VX CWDM (32 dB)
3FE 29549 CA
3FE 29550 CA
3FE 29551 CA
3FE 29552 CA
3FE 29553 CA
3FE 29554 CA
3FE 29555 CA
3FE 25772 AA GE-BX10-U Y
3FE 25772 AB GE-BX10-D Y Y Y
3FE 28784 AA 1000Base-T Y Y Y
3FE 28785 AA GE-BX40-U Y
3FE 28785 AB GE-BX40-D Y
SFP+
3FE 62600 AA 10GE-R
3FE 62600 CA 10GE-R
3FE 62600 DA 10GE-R Y
3FE 62600 EA 10GE-R Y
3FE 65608 AA 10GE-R Y
3FE 63264 AA 10GE-R Y
3FE 65831 AA 10GE-R Y
3FE 65832 AA 10GE-R
Dual SFP
3FE 65106 AA GE-BX10-D Y
3FE 65107 AA FE-BX10-D Y
3FE 66131 AA(1) FE-BX10-D
GE-BX-10-D
Y
Y
GPON SFP
3FE 53441 AC GPON SFP B+ Y
3FE 53441 BA GPON SFP C+ Y
3FE 53441 CC with OTDR GPON SFP B+ with OTDR Y
EPON SFP
3FE 53606 AA EPON PX20+ Y
3FE 66282 AA EPON PX20+ OTDR Y
Code Description
FA
NT
-F
FN
IO-B
NEL
T-B
NG
LT-A
FPLT
-A
(2 of 2)
5 — SFP Optical Modules
5-4 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Table 5-2 Characteristics of Approved SFP Modules
Code Description Wavelength(nm)
Operating CaseTemp. Range (°C)
OpticalBudget(dB)
Reach(km)
Fiber Bidi/Uni
UDS(1)
Fast Ethernet SFP
3FE 25777 AA FE-FX 1310 -40..+85 12 0.550 MM Uni DAAA
3FE 25778 AA FE-LX10 1310 -40..+85 16 15 SM Uni
3FE 29194 AA FE BX-10-D TX: 1550
RX: 1310
-40..+85 14 10 SM Bidi FAAA
3FE 29194 BA FE BX-10-D TX: 1490
RX: 1310
-40..+85 14 10 SM Bidi
3FE 29195 AA FE BX-10-U TX: 1310
RX: 1550
-40..+85 14 10 SM Bidi
3FE 63343 AA 100Base-T NA 0..+70 NA 0.100 Cat5 NA PAAA
Gigabit Ethernet SFP
3FE 25773 AA GE-SX 850 -40..+85 7 0.550 MM Uni CAAA
3FE 25774 AA GE-LX 1310 -40..+85 11 10 SM Uni
3FE 25775 AA GE-EX 1310 -40..+85 18 40 SM Uni
3FE 25776 AA GE-ZX 1550 -40..+85 24 80 SM Uni
3FE 25771 AA GE-YX
CWDM
(24 dB)
1471 -40..+85 22 62 SM Uni AAAA
3FE 25771 AB 1491
3FE 25771 AC 1511
3FE 25771 AD 1531
3FE 25771 AE 1551
3FE 25771 AF 1571
3FE 25771 AG 1591
3FE 25771 AH 1611
3FE 25771 CA GE-VX
CWDM
(32 dB)
1471 -5..+85 31 120 SM Uni
3FE 29549 CA 1491
3FE 29550 CA 1511
3FE 29551 CA 1531
3FE 29552 CA 1551
3FE 29553 CA 1571
3FE 29554 CA 1591
3FE 29555 CA 1611
(1 of 2)
5 — SFP Optical Modules
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 5-53HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3FE 25772 AA GE-BX10-U TX: 1310
RX: 1490
-40..+85 9 10 SM Bidi GAAA
3FE 25772 AB GE-BX10-D TX: 1490
RX: 1310
-40..+85 9 10 SM Bidi
3FE 28785 AA GE-BX40-U TX: 1310
RX: 1550
-40..+85 19 40 SM Bidi
3FE 28785 AB GE-BX40-D TX: 1550
RX: 1310
-40..+85 19 40 SM Bidi
3FE 28784 AA 1000Base-T NA 0..+85 NA 0.100 Cat5 NA EAAA
SFP+
3FE 62600 AA 10GE-R 1310 -40..+85 10 10 SM Uni MAAA
3FE 62600 CA 10GE-R 1310 -5..+85 10 10 SM Uni
3FE 62600 DA 10GE-R 1310 0..+70 10 10 SM Uni
3FE 62600 EA 10GE-R 1310 -40..+85 10 10 SM Uni
3FE 65608 AA 10GE-R 850 0..+70 11 0.3 MM Uni
3FE 63264 AA 10GE-R 850 -40..+85 11 0.3 MM Uni
3FE 65831 AA 10GE-R 1550 -40..+85 15 40 SM Uni
3FE 65832 AA 10GE-R 1550 -40..+85 24 80 SM Uni
Dual SFP
3FE 65106 AA GE-BX10-D TX: 1490
RX: 1310
-40..+85 9 10 SM Bidi
TAAA3FE 65107 AA FE-BX10-D TX: 1550
RX: 1310
-40..+85 14 10 SM Bidi
3FE 66131 AA FE-BX10-D
GE-BX10-D
TX: 1490
RX: 1310
-40..+85 8 (FE)
9 (GE)
10 SM Bidi
GPON SFP
3FE 53441 AC Class B+, normal
TX: 1490
RX: 1310
-40..+85 28 30 SM Bidi
RAAA3FE 53441 BA Class C+,
normalTX: 1490
RX: 1310
-5..+70 32 60 SM Bidi
3FE 53441 CC Class B+, with OTDR
TX: 1490
RX: 1310
-40..+85 28 30 SM Bidi
EPON SFP
3FE 53606 AA EPON PX20+ TX: 1490
RX: 1310
-40..+85 32 20 SM Bidi UAAA
3FE 66282 AA EPON PX20+ OTDR
TX: 1490
RX: 1310
-40..+85 32 20 SM Bidi
Code Description Wavelength(nm)
Operating CaseTemp. Range (°C)
OpticalBudget(dB)
Reach(km)
Fiber Bidi/Uni
UDS(1)
(2 of 2)
5 — SFP Optical Modules
5-6 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Note(1) For more detailed information on the different characteristics of the SFP module, refer to UDS 3HH
01046 xxxx TQZZA (where xxxx is the document variant indicated in this column).
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 A-13HH-10116-AAAA-TCZZA Edition 01 Released Product Information
A. Board Mnemonics
A.1 Board Mnemonics A-2
A. Board Mnemonics
A-2 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
A.1 Board Mnemonics
Table A-1 gives the used board mnemonics with their description.
Table A-1 Mnemonics
Mnemonic Description
AFAN-H Fan unit - version H
AFAN-E FX-8 Fan unit - version E
AFAN-X FX-4 Fan unit - version X
FANT-F Combined NT Unit - version F
FNIO-B FX FE/GE Network Termination I/O Applique - version B
FPLT-A EPON Line Termination Board - version A
NELT-B 36-line Fast Ethernet/Gigabit Ethernet Line Termination Unit - version B
NFXS-D FX-16 Shelf for ETSI/MII
NFXS-E FX-8 Shelf for ETSI/MII
NFXS-F FX-4 Shelf for ETSI/MII
NGFC-E General Facilities Card - version E
NGFC-F General Facilities Card - version F
NGLT-A GPON Line Termination Board - version A
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 IN-13HH-10116-AAAA-TCZZA Edition 01 Released Product Information
Index
Numbers
7360 FXrack configurations, 4-2subrack configurations, 2-4subrack types, 2-2Supported plug-in units, 2-6
C
CLEI codes, 1-26
D
Dimensioning, 1-19GPON, 1-24
Dummy front panels, 2-7
G
GPONdimensioning, 1-24
I
IWFcapabilities, 1-19
M
ManagementNetwork, 1-17
N
Network topology, 1-2Network side, 1-4User side, 1-3
P
Plug-in units, 2-6
R
Redundancy support1+1 NT, 1-25
S
SFP modules, 5-2System architecture, 1-6
IHub, 1-16
T
Technical specificationsP-OLT connection capacity, 1-25
Index
IN-2 July 2011 Alcatel-Lucent 7360 ISAM FX R4.3Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
U
Universal rack, 3-2Locks, 3-7Rack door, 3-6Side plates, 3-5type, 3-2
U — Universal rack
Customer documentation and product support
Customer documentationhttp://www.alcatel-lucent.com/myaccessProduct manuals and documentation updates are available at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.
Technical Supporthttp://www.alcatel-lucent.com/support
Documentation feedbackdocumentation.feedback@alcatel-lucent.com
© 2011 Alcatel-Lucent. All rights reserved.3HH-10116-AAAA-TCZZA Edition 01 Released