Port Harcourt Cluster Pre-Drive Test Report
Title: Port Harcourt City VIP Route Drive Test Report (Long Calls)
Version:
Drive test dates:
Author: NE RF P & O
Issued date:
Language: English
Status:
Description: Port Harcourt City VIP Route Drive Test Report
DISTRIBUTION LIST:
Name: Company: Position:
DOCUMENT HISTORY:
Version: Date Author: Details:
APPROVAL
Name Position Date SignatureNational Optimisation
Page 3/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
Table of Contents
1. Coverage Analysis 4Method 4
Distribution of Measurement Data .................................................................................4-72G Rx Level Plot (UE) 8
2G Rx Quality Plot (UE) 92G SQI Plot (UE) 10
2G Coverage-Quality Statistic ..11
2. 2G KPI Trend 12No. Of Sites on Air 112G In Call KPI 12Event Summary 122G Drop Call causes breakdown 132G Call Setup Failure causes breakdown 13
2G Call Setup Success Rate and Drop Call Rate..........................................................14 2G Call Statistic 14-15 2G Performance 16
3. Appendix-1 16Legend 16Coverage-Quality Criterion 16
NE RF P & O December 24, 2009
Page 4/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
1. Coverage Analysis
MethodThe method used to collect data for the analysis can be divided into two different measurement types.
Short CallsA short voice call attempt was performed every 50 seconds, including 10 seconds of idle time between two consecutive calls. A script in the TEMS Investigation logging tool automatically initiates the short calls. An event “Call Attempt” was generated every time the script triggered a new call attempt meaning the number was dialled. The other event “Blocked Call” was generated every time the call setup procedure failed. The MS was inside the car and no external antenna was used.
Long CallsLong voice calls are established automatically and are ended by blocks, drops or normal user release. TEMS Investigation tool generated an event “Drop Call” every time the connection dropped. The MS was inside the car and no external antenna was used.
MEASUREMENT DATA DISTRIBUTION
Below gives the over all distribution summary
NE RF P & O December 24, 2009
Page 5/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
NE RF P & O December 24, 2009
Page 6/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
NE RF P & O December 24, 2009
Page 7/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
2G RX LEVEL PLOT (UE)
NE RF P & O December 24, 2009
Page 8/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
2G RX QUALITY PLOT (UE)
NE RF P & O December 24, 2009
Page 9/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
2G SPEECH QUALITY INDEX PLOT (UE)
NE RF P & O December 24, 2009
Page 10/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
NE RF P & O December 24, 2009
Page 11/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
2G COVERAGE QUALITY STATISTICS
2. 2G KPI Trend
NUMBER OF SITES ON AIR
NE RF P & O December 24, 2009
Page 12/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
2G IN CALL KPI
SUMMARY OF EVENTS
EVENTSCount of Event
Blocked Call 2Call Attempt 22Call Attempt Retry 1Call End 1Call Established 20Call Setup 20Cell Reselection 8Dedicated Mode 21Dropped Call 9Handover 352Handover Failure 12Handover Intracell 198Handover Intracell Failure 9Idle Mode 21Missing Neighbor Detection, GSM Symmetry 2
NE RF P & O December 24, 2009
Page 13/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
2G DROP CALL CAUSES BREAKDOWN
2G CALL SETUP FAILURE CAUSES BREAKDOWN
NE RF P & O December 24, 2009
Page 14/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
2G CALL SETUP SUCCESS RATE AND DROP CALL RATE
Figure 2.4 CSSR and DCR Plots
2G CALL STATISTIC
Week Begin 19/12/09 23/12/09
PH VIP Route
PRE-DT GOMBE POST-DT
Mean Rx Level (dBm) -80.99
Mean Rx Quality (0-7) 0.94
2G Coverage Quality
Radio Good 84.80%
Radio OK 4.49%
Interference 10.07%
Coverage limited 0.00%
2G Call Performance
Call Attempt 99
Attempt Failure 0
Attempt Failure Rate 0.00%
Good Initialization 58
NE RF P & O December 24, 2009
Page 15/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
Call Setup Success Rate 100.00%
Call Drop 2
Call Drop Rate 0.03%
Normal Termination 56
Call Retainability 99.7.00%
HO Attempt 292
HO Failure 4
HO Failure Rate 0.01%
HO Success 288
HO Success Rate 98.63%
Average Call Setup Time (sec)
% Call Setup Time < 6 secs 100.00%
Attempt Failure 0
SDCCH Blocking 0
SDCCH Blocking Rate 0.00%
TCH Blocking 0
TCH Blocking Rate 0.00%
Hardware Problem 1
Hardware Problem Rate 0.00%
No Service 0
No Service Rate 0.00%
Access Failure 0
Access Failure Rate 0.00%
Call Drop 0
HO Failure - Drop 0
HO Failure - Drop (%) 0.00%
Inconclusive - Drop 0
Inconclusive - Drop (%) 0.00%
Neighbor Issue/Cong - Drop 0
Neighbor Issue/Cong - Drop (%) 0.00%
Interference - Drop 1
Interference - Drop (%) 0.00%
Poor Coverage - Drop 0
Poor Coverage - Drop (%) 0.00%
Hardware problem - Drop 1
Hardware problem - Drop (%) 0.00%
Antenna problem - Drop 0
Antenna problem - Drop (%) 0.00%
Composite Score
NE RF P & O December 24, 2009
Page 16/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
2G PERFORMANCE
Attached is the summary of the overall events, with detailed recommendations/actions to be taken to improve performance.
3. Appendix-1
Legend
1. 2G Rx Level and Rx Quality
Coverage-Quality Criterion
2G Coverage-Quality Criterion
NE RF P & O December 24, 2009
Page 17/17
Port Harcourt VIP Roote Drive Test- Short Call W 51
NE RF P & O December 24, 2009
Recommended