2G Parameter Template Data and Voice Optimization

Embed Size (px)

Citation preview

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    1/85

    3GIS RAN Parameter

    Version Date Review made Creator Approver

    1 9/5/2007 Bevan Smith; Waseem Aamer Ahmed Soltan New Paramete2 9/17/2007 Bevan Smith Ahmed Soltan Combined IBS

    2.1 9/27/2007 Bevan Smith Ahmed Soltan Added Classif

    2.2 10/3/2007 Bevan Smith Ahmed Soltan Network Align

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    2/85

    3GIS RAN Parameter

    Changes since previous version

    Change all PLMN Permitted to true, change GPRS CDED 15 - 5 and CDEF 30 - 28.

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    3/85

    NMS ID nms_id NWP

    BSC ID bscId NWP

    Address address -

    Alarm Threshold For TCH Failure Rate alrmChFail NWPAlarm Threshold For Number Of Channel Seizures alrmNoOfSei NWP

    Alarm Threshold For SDCCH Failure Rate alrmSchFail NWP

    Alarm Threshold For SDCCH Congestion alrmSdcch NWP

    Alarm Threshold For Number Of Channel Seizure Reque alrmSeizReq NWP

    Alarm Threshold For TCH Congestion alrmTch NWP

    AMH Lower Load Threshold amhLowerLoadThreshold NWP

    AMH Max Load Of Target Cell amhMaxLoadOfTgtCell NWP

    TRHO Guard Time amhTrhoGuardTime NWP

    AMH Upper Load Threshold amhUpperLoadThreshold NWP

    Bad Quality Limit badQualLimit NWP

    BTS Site Battery Backup Forced HO Timer batteryBackupTimer NWP

    BCSU Load Threshold bcsuLoadThr NWP

    BSC Call Number bscCallNumber NWP

    Real BSC SW Release bscSwRelease NWP

    Number Of Ignored Transcoder Failures callReleaseLimit NWP

    DCS Macrocell Threshold dcsMacrocellThreshold NWP

    DCS Microcell Threshold dcsMicrocellThreshold NWP

    Disable External DR disableExtDr NWP

    Disable Internal HO disableIntHo NWP

    Enable Emergency Call On FACCH emerCallOnFacch NWP

    BCSU Number extraTrxBcsuNumber NWP

    Max TRX Number in BCSU extraTrxMaxTrxInBcsu NWP

    Alarm Limit For Full Rate TCH Availability frTchALim NWP

    Good Quality Limit goodQualLimit NWP

    GSM Macrocell Threshold gsmMacrocellThreshold NWP

    GSM Microcell Threshold gsmMicrocellThreshold NWP

    HO Preference Order Interference DL hoPrefOrderInterfDl NWP

    HO Preference Order Interference UL hoPrefOrderInterfUl NWP

    Alarm Limit For Half Rate TCH Availibility hrTchALim NWP

    LAPD Load Threshold lapdLoadThr NWP

    Load Rate for Channel Search loadRateChSearch NWP

    Max BCF Capacity maxBcfCapacity NWP

    Max BTS Capacity maxBtsCapacity NWP

    Maximum Mean Holding Time For SDCCHs maxHldSdcch NWP

    Maximum Mean Holding Time For TCHs maxHldTch NWP

    Alarm Threshold For The Share Of High TCH Interferenc maxOnHiIf NWP

    Max TRX Capacity HW maxTrxCapacityHw NWP

    Max TRX Capacity Real maxTrxCapacityReal NWP

    Measurement Period For Supervision Of Congestion In B measPrdCh NWP

    Meas Period For Supervision Of Channel Failure Rate measPrdFail NWP

    Meas Period For SDCCH Mean Holding Time Supervisio measPrdSdcch NWP

    Meas Period For TCH Mean Holding Time Supervision measTchMhold NWP

    Threshold For High TCH Interference Level minHiIf NWP

    Minimum Mean Holding Time For TCHs minHldTch NWP

    MS Distance Behaviour msDistanceBehaviour NWP

    Full Name Database Abbreviation Class

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    4/85

    Upper Limit Of MS Speed Class 1 msSpeedC11 NWP

    Upper Limit Of MS Speed Class 2 msSpeedC12 NWP

    Name name -

    BTS Supervision Stopping Time Hour nokBtsOffHour NWP

    BTS Supervision Stopping Time Minute nokBtsOffMinute NWP

    BTS Supervision Starting Time Hour nokBtsOnHour NWP

    BTS Supervision Starting Time Minute nokBtsOnMinute NWP

    Number Of Preferred Cells noOfPrefCells NWP

    Enable Ordinary Calls On FACCH ordinaryCallOnFacch NWP

    Enable Answer To Paging Call On FACCH pagingAnsOnFacch NWP

    Subscriber Type 1 pieToSubscriberType1 NWP

    Subscriber Type 2 pieToSubscriberType2 NWP

    Subscriber Type 3 pieToSubscriberType3 NWP

    Subscriber Type 4 pieToSubscriberType4 NWP

    Subscriber Type 5 pieToSubscriberType5 NWP

    Subscriber Type 6 pieToSubscriberType6 NWP

    Subscriber Type 7 pieToSubscriberType7 NWP

    Subscriber Type 8 pieToSubscriberType8 NWP

    Subscriber Type 9 pieToSubscriberType9 NWPSubscriber Type 10 pieToSubscriberType10 NWP

    Subscriber Type 11 pieToSubscriberType11 NWP

    Subscriber Type 12 pieToSubscriberType12 NWP

    Subscriber Type 13 pieToSubscriberType13 NWP

    Subscriber Type 14 pieToSubscriberType14 NWP

    Meas Period For High TCH Interference Supervision prdHighIf NWP

    Meas Period For Supervision Of BTS With No Transact prdNokBts NWP

    Enable Call Re-Establishment On FACCH reestablishOnFacch NWP

    RX Antenna Supervision Period rxAntSupPer NWP

    RX Level Balance rxLevBalance NWP

    Alarm Limit For SDCCH Availability sdcchAlLimit NWP

    Signal Quality Limit 1 sigQualLimit1 NWPSignal Quality Limit 2 sigQualLimit2 NWP

    TCH Probability 1 tchProbability1 NWP

    TCH Probability 2 tchProbability2 NWP

    TCH Probability 3 tchProbability3 NWP

    GPRS Territory Update Guard Time terrUpdGuardTGprs NWP

    Variable DL Step Size variableDlStepSize NWP

    BSC SW Version Version NWP

    AMR Configuration In Handovers amrConfInHandovers NWP

    AMR Set Grades Enabled amrSetGradesEnabl NWP

    ANSI Environment ansiEnvironment NWP

    Lower Limit For FR TCH Resources btsLoadDepTchRateLower NWP

    Upper Limit For FR TCH Resources btsLoadDepTchRateUpper NWP

    FEP In PC HO Use fepInPcHoUse NWP

    Free TSL For CS Downgrade freeTSLsCsDowngrade NWP

    Free TSLs for CS Upgrade freeTSLsCsUpgrade NWP

    Frequency Band In Use frequencyBandInUse NWP

    Initial AMR Channel Rate initAmrChannelRate NWP

    Intra segment SDCCH HO guard intraSegSdcchHoGuard NWP

    Maximum Number Of DL TBF pcuMaxNoDLtbfInCH NWP

    Maximum Number Of UL TBF pcuMaxNoULtbfInCH NWP

    DL High Priority SSS schedStepSizeDlHighPrior NWP

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    5/85

    DL Low Priority SSS schedStepSizeDlLowPrior NWP

    DL Normal Priority SSS schedStepSizeDlNormPrior NWP

    UL Priority 1 SSS schedStepSizeUlPrior1 NWP

    UL Priority 2 SSS schedStepSizeUlPrior2 NWP

    UL Priority 3 SSS schedStepSizeUlPrior3 NWP

    UL Priority 4 SSS schedStepSizeUlPrior4 NWP

    Slow AMR LA Enabled slowAmrLaEnabled NWP

    TCH In Handover tchRateInternalHo NWP

    BSC Type bscType NWP

    Site Id siteId -

    CS TCH Allocation Calculation gprsTerritoryCalc NWP

    CS TCH Allocation RTSL0 rtsl0PrefInTCHAlloc NWP

    Number Of Adjacent Cell Freqs In MeasBA Information adjCellFreqsInMeasBAInfo NWP

    Number Of Frequencies In MeasBA Information freqInMeasBAInfo NWP

    WPS Priority Capacity wpsPriCapa NWP

    WPS Preference Capacity wpsPrefCapa NWP

    Public Served Count publicServCount NWP

    Time Limit WPS timeLimitWPS NWP

    Time Limit WPS Handover timeLimitWPSHO NWPTriggering Threshold For Service Area Penalty incomeRateThreshold NWP

    Penalty Trigger Measurement Period triggerMeasPeriod NWP

    Service Area Penalty Time wcdmaRanSaiPenalty NWP

    pre-emption usage in handover preemptionUsageInHO NWP

    BIM Confidence Probability bimConfidenceProb NWP

    BIM Interference Threshold bimInterfThreshold NWP

    BIM Update Guard Time bimUpdateGuardTime NWP

    BIM Update Period bimUpdatePeriod NWP

    BIM Update Scaling Factor bimUpdateScalingFactor NWP

    C/I Target UL Offset ciTargetUlOffset NWP

    Delay Of HO And PC For Emergency Calls delayHoPcEmergencyCalls NWP

    C/I Target 14.4 dfca144Connection_ciTarget NWPSoft Blocking C/I 14.4 dfca144Connection_softBlockingCi NWP

    Soft Blocking C 14.4 dfca144Connection_softBlockingCn NWP

    C/I Target AMR FR dfcaAmrFrConnection_ciTarget NWP

    Soft Blocking C/I AMR FR dfcaAmrFrConnection_softBlockingCi NWP

    Soft Blocking C AMR FR dfcaAmrFrConnection_softBlockingCn NWP

    C/I Target AMR HR dfcaAmrHrConnection_ciTarget NWP

    Soft Blocking C/I AMR HR dfcaAmrHrConnection_softBlockingCi NWP

    Soft Blocking C AMR HR dfcaAmrHrConnection_softBlockingCn NWP

    DFCA Channel Allocation Method dfcaChannelAllocMethod NWP

    C/I Target FR dfcaFrConnection_ciTarget NWP

    Soft Blocking C/I FR dfcaFrConnection_softBlockingCi NWP

    Soft Blocking C FR dfcaFrConnection_softBlockingCn NWP

    C/I Target HR dfcaHrConnection_ciTarget NWP

    Soft Blocking C/I HR dfcaHrConnection_softBlockingCi NWP

    Soft Blocking C HR dfcaHrConnection_softBlockingCn NWP

    Expected BSC-BSC Interface Delay expectedBscBscInterfaceDelay NWP

    IMSI Based Handover GSM Cells Anonymous MS ibhoGsmCellsAnoMs NWP

    IMSI Based Handover WCDMA Cells Anonymous MS ibhoWcdmaCellsAnoMs NWP

    NACC Enabled naccUsage NWP

    NCCR Control Mode nccrControlMode NWP

    NCCR Idle Mode Reporting Period nccrIdleModeRepPeriod NWP

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    6/85

    NCCR Neighbor Cell Penalty nccrNeighborCellPenalty NWP

    NCCR Return To Old Cell Time nccrReturnOldCellTime NWP

    NCCR Target Cell Penalty Time nccrTargetCellPenalty NWP

    NCCR Transfer Mode Reporting Period nccrTraModeRepPeriod NWP

    PFC Ack BLER Limit For Transfer Delay 2 pfcAckBlerLimit_legacyStream NWP

    PFC Ack BLER Limit For Transfer Delay 5 pfcAckBlerLimit_limit10004000ms NWP

    PFC Ack BLER Limit For Transfer Delay 3 pfcAckBlerLimit_limit10150ms NWP

    PFC Ack BLER Limit For Transfer Delay 4 pfcAckBlerLimit_limit200950ms NWP

    PFC Ack BLER Limit For Transfer Delay 1 pfcAckBlerLimit_notAvailable NWP

    Bg Traffic Class PFC NRT Nominal Bitrate For ARP 1 pfcNrtNominalBitr_backgroundARP1 NWP

    Bg Traffic Class PFC NRT Nominal Bitrate For ARP 2 pfcNrtNominalBitr_backgroundARP2 NWP

    Bg Traffic Class PFC NRT Nominal Bitrate For ARP 3 pfcNrtNominalBitr_backgroundARP3 NWP

    Interactive 1 TC PFC NRT Nominal Bitrate For ARP 1 pfcNrtNominalBitr_interactive1ARP1 NWP

    Interactive 1 TC PFC NRT Nominal Bitrate For ARP 2 pfcNrtNominalBitr_interactive1ARP2 NWP

    Interactive 1 TC PFC NRT Nominal Bitrate For ARP 3 pfcNrtNominalBitr_interactive1ARP3 NWP

    Interactive 2 TC PFC NRT Nominal Bitrate For ARP 1 pfcNrtNominalBitr_interactive2ARP1 NWP

    Interactive 2 TC PFC NRT Nominal Bitrate For ARP 2 pfcNrtNominalBitr_interactive2ARP2 NWP

    Interactive 2 TC PFC NRT Nominal Bitrate For ARP 3 pfcNrtNominalBitr_interactive2ARP3 NWP

    Interactive 3 TC PFC NRT Nominal Bitrate For ARP 1 pfcNrtNominalBitr_interactive3ARP1 NWPInteractive 3 TC PFC NRT Nominal Bitrate For ARP 2 pfcNrtNominalBitr_interactive3ARP2 NWP

    Interactive 3 TC PFC NRT Nominal Bitrate For ARP 3 pfcNrtNominalBitr_interactive3ARP3 NWP

    SMS PFC Predefined Nominal Bitrate pfcNrtNominalBitr_sms NWP

    Best Effort ARP 1 PFC Predefined Nominal Bitrate pfcPredefNominalBitr_PredefNbrARP1 NWP

    Best Effort ARP 2 PFC Predefined Nominal Bitrate pfcPredefNominalBitr_PredefNbrARP2 NWP

    Best Effort ARP 3 PFC Predefined Nominal Bitrate pfcPredefNominalBitr_PredefNbrARP3 NWP

    Signalling PFC Predefined Nominal Bitrate pfcPredefNominalBitr_PredefNbrSignaling NWP

    SMS PFC Predefined Nominal Bitrate pfcPredefNominalBitr_PredefNbrSms NWP

    PFC Predefined Traffic Class For Best Effort ARP 1 pfcPredefTrafficClass_bestEffortArp1 NWP

    PFC Predefined Traffic Class For Best Effort ARP 2 pfcPredefTrafficClass_bestEffortArp2 NWP

    PFC Predefined Traffic Class For Best Effort ARP 3 pfcPredefTrafficClass_bestEffortArp3 NWP

    PFC Predefined Traffic Class For Signaling pfcPredefTrafficClass_signaling NWPPFC Predefined Traffic Class For SMS pfcPredefTrafficClass_sms NWP

    PFC Unack BLER Limit For SDU Error Ratio 2 pfcUnackBlerLimit_legacyStream NWP

    PFC Unack BLER Limit For SDU Error Ratio 3 pfcUnackBlerLimit_limit110e1 NWP

    PFC Unack BLER Limit For SDU Error Ratio 4 pfcUnackBlerLimit_limit110e2 NWP

    PFC Unack BLER Limit For SDU Error Ratio 6 pfcUnackBlerLimit_limit110e3 NWP

    PFC Unack BLER Limit For SDU Error Ratio 5 pfcUnackBlerLimit_limit710e3 NWP

    PFC Unack BLER Limit For SDU Error Ratio 1 pfcUnackBlerLimit_notAvailable NWP

    QC Drop Action Trigger Threshold qcActionTriggerThr_drop NWP

    QC NCCR Action Trigger Threshold qcActionTriggerThr_nccr NWP

    QC QoS Renegotiation Action Trigger Threshold qcActionTriggerThr_qosRenego NWP

    QC Reallocation Action Trigger Threshold qcActionTriggerThr_realloca NWP

    RX Level Based TCH Access rxLevelBasedTchAccess NWP

    Background Traffic Class Scheduling Theta For ARP 1 schedulingTheta_backgroundARP1 NWP

    Background Traffic Class Scheduling Theta For ARP 2 schedulingTheta_backgroundARP2 NWP

    Background Traffic Class Scheduling Theta For ARP 3 schedulingTheta_backgroundARP3 NWP

    Interactive 1 Traffic Class Scheduling Theta For ARP 1 schedulingTheta_interactive1ARP1 NWP

    Interactive 1 Traffic Class Scheduling Theta For ARP 2 schedulingTheta_interactive1ARP2 NWP

    Interactive 1 Traffic Class Scheduling Theta For ARP 3 schedulingTheta_interactive1ARP3 NWP

    Interactive 2 Traffic Class Scheduling Theta For ARP 1 schedulingTheta_interactive2ARP1 NWP

    Interactive 2 Traffic Class Scheduling Theta For ARP 2 schedulingTheta_interactive2ARP2 NWP

    Interactive 2 Traffic Class Scheduling Theta For ARP 3 schedulingTheta_interactive2ARP3 NWP

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    7/85

    Interactive 3 Traffic Class Scheduling Theta For ARP 1 schedulingTheta_interactive3ARP1 NWP

    Interactive 3 Traffic Class Scheduling Theta For ARP 2 schedulingTheta_interactive3ARP2 NWP

    Interactive 3 Traffic Class Scheduling Theta For ARP 3 schedulingTheta_interactive3ARP3 NWP

    Streaming Traffic Class Scheduling Theta For ARP 1 schedulingTheta_streamingARP1 NWP

    Streaming Traffic Class Scheduling Theta For ARP 2 schedulingTheta_streamingARP2 NWP

    Streaming Traffic Class Scheduling Theta For ARP 3 schedulingTheta_streamingARP3 NWP

    Background Traffic Class Scheduling Weight For ARP 1 schedulingWeight_backgroundARP1 NWP

    Background Traffic Class Scheduling Weight For ARP 2 schedulingWeight_backgroundARP2 NWP

    Background Traffic Class Scheduling Weight For ARP 3 schedulingWeight_backgroundARP3 NWP

    Interactive 1 Traffic Class Scheduling Weight For ARP 1 schedulingWeight_interactive1ARP1 NWP

    Interactive 1 Traffic Class Scheduling Weight For ARP 2 schedulingWeight_interactive1ARP2 NWP

    Interactive 1 Traffic Class Scheduling Weight For ARP 3 schedulingWeight_interactive1ARP3 NWP

    Interactive 2 Traffic Class Scheduling Weight For ARP 1 schedulingWeight_interactive2ARP1 NWP

    Interactive 2 Traffic Class Scheduling Weight For ARP 2 schedulingWeight_interactive2ARP2 NWP

    Interactive 2 Traffic Class Scheduling Weight For ARP 3 schedulingWeight_interactive2ARP3 NWP

    Interactive 3 Traffic Class Scheduling Weight For ARP 1 schedulingWeight_interactive3ARP1 NWP

    Interactive 3 Traffic Class Scheduling Weight For ARP 2 schedulingWeight_interactive3ARP2 NWP

    Interactive 3 Traffic Class Scheduling Weight For ARP 3 schedulingWeight_interactive3ARP3 NWP

    Streaming Traffic Class Scheduling Weight For ARP 1 schedulingWeight_streamingARP1 NWPStreaming Traffic Class Scheduling Weight For ARP 2 schedulingWeight_streamingARP2 NWP

    Streaming Traffic Class Scheduling Weight For ARP 3 schedulingWeight_streamingARP3 NWP

    Signalling Point CodeIN0 signallingPointCodeIN0 NWP

    Signalling Point CodeIN1 signallingPointCodeIN1 NWP

    Signalling Point CodeNA0 signallingPointCodeNA0 NWP

    Signalling Point CodeNA1 signallingPointCodeNA1 NWP

    WCDMA FDD NCCR Enabled wcdmaFddNccrEnabled NWP

    WCDMA FDD NCCR Preferred wcdmaFddNccrPreferred NWP

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    8/85

    Definition Range & Step DB Nokia Default

    Identifier (ID) of NMS object 0 ... 63555 -

    Identification (c-number) of BSC. NOTE 0 ... 999999 -

    Site Address where the physical BTS is - -

    With this parameter you define an alar 1 ... 100 20The parameter supervises lost calls and 1 ... 65535 10

    With this parameter you define an alar 1 ... 100 80

    With this parameter you define an alar 1 ... 100 20

    The parameter supervises SDCCH and 1 ... 65535 100

    With this parameter you define an alar 1 ... 100 20

    With this parameter you define the lowe 0 ... 100 20

    With this advanced multilayer handling 0 ... 100 70

    With this parameter you define the guar 0 ... 120 30

    With this parameter you define the upp 0 ... 100 80

    With this parameter you define the limit 0 ... 100 100

    The parameter defines the maximum ti 1 ... 500 30

    With this parameter you define the thre 0 ... 10000 150

    With this parameter you define the BSC 0

    Version of the active BSC software rele -

    With this parameter you define how ma 0 ... 5 0

    With this parameter you define the mac 0 ... 31 2

    With this parameter you define the micr 0 ... 31 3

    With this parameter you disable or enab 0 ... 1 0

    With this parameter you define whether 0 ... 1 0

    With this parameter you enable or disab 0 ... 1 0

    Defines the number of BCSU units withi -

    Maximum allowed number of transceive -

    With this parameter you define the alar 0 ... 100 30

    With this parameter you define the limit 0 ... 100 100

    With this parameter you define the mac 0 ... 19 4

    With this parameter you define the micr 0 ... 19 5

    With this parameter you define the orde 0 ... 1 0

    With this parameter you define the orde 0 ... 1 0

    With this parameter you define the alar 1 ... 100 30

    With this parameter you define the thre 0 ... 10000 150

    With this parameter you define the gen 0 ... 100 100

    Defines the maximum allowed number -

    Defines the maximum allowed number -

    With this parameter you define the maxi 0 ... 1440 30

    With this parameter you define the maxi 0 ... 1440 120

    With this parameter you define the maxi 1 ... 100 50

    Defines the maximum transceiver capa -

    Defines the maximum transceiver capa -

    The parameter supervises SDCCH and 0 ... 1440 120

    The parameter supervises channel failu 0 ... 1440 60

    The parameter supervises too long mea 0 ... 1440 60

    The parameter supervises too short and 0 ... 1440 240

    With this parameter you define the inter 0 ... 4 4

    With this parameter you define the mini 0 ... 65535 10

    With this parameter you define the exec 0 ... 255 255

    Information

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    9/85

    With this parameter you define the upp 0 ... 255 10

    With this parameter you define the upp 0 ... 255 30

    Adjacent cell name, same as target BT -

    Attribute indicates the hour on which th 0 ... 23 18

    Attribute indicates the minute on which t 0 ... 59 0

    Attribute indicates the hour on which th 0 ... 23 8

    Attribute indicates the minute on which t 0 ... 59 0

    With this parameter you define the maxi 1 ... 16 3

    With this parameter you enable or disab 0 ... 1 0

    With this parameter you enable or disab 0 ... 1 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the subs 0 ... 2 0

    With this parameter you define the mea 0 ... 1440 120

    With this parameter you define the mea 0 ... 1440 120

    With this parameter you enable or disab 0 ... 1 0

    With this parameter you define the time, 15 ... 65535 65535

    With this parameter you define the bala 0 ... 20 5

    With this parameter you define the alar 0 ... 100 30

    With this parameter you define the lowe 0 ... 100 100With this parameter you define the upp 0 ... 100 100

    With this parameter you define the prob 0 ... 100 100

    With this parameter you define the prob 0 ... 100 100

    With this parameter you define the prob 0 ... 100 100

    With this parameter you set the time wh 1 ... 255 5

    With this parameter you define whether 0 ... 1 0

    BSC SW version S11.5

    With this parameter you define the pref 1 ... 2 1

    With this parameter you define whether 0 ... 1 0

    The attribute defines if the BSC is oper 0 ... 1 0

    The parameter controls the TCH chann 0 ... 100 40

    The parameter controls the TCH chann 0 ... 100 60

    With this parameter you can indicate w 0 ... 1 0

    The parameter gives a target probability 0 ... 100 95

    With this parameter you define a period 0 ... 10 4

    With this parameter you define the type 0 ... 5 0

    With this parameter you define the initi 1 ... 2 1

    With this parameter you define the guar 0 ... 255 255

    With this parameter you define the maxi 1 ... 9 9

    With this parameter you define the maxi 1 ... 7 7

    With this parameter you define the sche 1 -12 3

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    10/85

    With this parameter you define the sche 1 -12 12

    With this parameter you define the sche 1 -12 6

    With this parameter you define the sche 1 -12 3

    With this parameter you define the sche 1 -12 6

    Defines the scheduling step side (SSS) 1 -12 9

    Defines the scheduling step side (SSS) 1 -12 12

    With this parameter you define the AM 0 ... 1 0

    With this parameter you define the traffi 1 ... 5 1

    The type of BSC. BSC3i provides more - -

    Identifier (ID) of SITE object - -

    With this parameter you define how the 0 ... 2 0

    With this parameter you define the prior 0 ... 1 0

    With this parameter you define how ma 0 ... 32 10

    With this parameter you define how ma 1 ... 32 32

    With this parameter you define the porti 0 ... 100 25

    With this parameter you define how mu 0 ... 100 97

    With this parameter you define how ma 0 ... 10 3

    With this parameter you define the maxi 0 ... 30 28

    With this parameter you define the maxi 0 ... 30 5With this parameter you define the trigg 0 ... 255 127

    With this parameter you define the leng 0 ... 254 128

    With this parameter you define the dura 0 ... 255 127

    With this parameter you define if the pr 0 ... 1 1

    With this parameter you define the level 50 ... 95 90

    With this parameter you define an uppe 0 ... 35 30

    With this parameter you define the num 0 ... 63 10

    With this parameter you define the peri 0 ... 1440 60

    With this parameter you define the weig 0 ... 10 5

    With this parameter you define an offse -31 ... 31 0

    With this parameter you can temporarily 0 ... 10 5

    With this parameter you define the targ 0 ... 63 16With this parameter you define the mini -20 ... 43 -20

    With this parameter you define the mini 0 ... 63 14

    With this parameter you define the targ 0 ... 63 8

    With this parameter you define the mini -20 ... 43 -20

    With this parameter you define the mini 0 ... 63 7

    With this parameter you define the targ 0 ... 63 12

    With this parameter you define the mini -20 ... 43 -20

    With this parameter you define the mini 0 ... 63 12

    With this parameter you define if DCFA 0 ... 1 0

    With this parameter you define the targ 0 ... 63 14

    With this parameter you define the mini -20 ... 43 -20

    With this parameter you define the mini 0 ... 63 12

    With this parameter you define the targ 0 ... 63 14

    With this parameter you define the mini -20 ... 43 -20

    With this parameter you define the mini 0 ... 63 14

    This parameter is used in the Radio Re 0 ... 200 5

    With this parameter you define in the ca 0 ... 10 0

    With this parameter you define in the ca 0 ... 10 0

    With this parameter you define the usag 0 ... 1 0

    With this parameter you enable or disab 0 ... 4 0

    With this parameter you define the Net 0 ... 7 5

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    11/85

    With this parameter you define the pen 1 ... 60 6

    With this parameter you define the start 5 ... 20 10

    With this parameter you define the time 5 ... 60 10

    With this parameter you define the Net 0 ... 7 0

    With this parameter you define the maxi 0 ... 100 10

    With this parameter you define the maxi 0 ... 100 90

    With this parameter you define the maxi 0 ... 100 10

    With this parameter you define the maxi 0 ... 100 70

    With this parameter you define the maxi 0 ... 100 90

    With this parameter you define the PFC 0 ... 64 2

    With this parameter you define the PFC 0 ... 64 2

    With this parameter you define the PFC 0 ... 64 2

    With this parameter you define the PFC 0 ... 64 4

    With this parameter you define the PFC 0 ... 64 4

    With this parameter you define the PFC 0 ... 64 4

    With this parameter you define the PFC 0 ... 64 4

    With this parameter you define the PFC 0 ... 64 4

    With this parameter you define the PFC 0 ... 64 4

    With this parameter you define the PFC 0 ... 64 4With this parameter you define the PFC 0 ... 64 4

    With this parameter you define the PFC 0 ... 64 4

    With this parameter you define the nomi 0 ... 64 1

    With this parameter you define the nomi 0 ... 64 2

    With this parameter you define the nomi 0 ... 64 2

    With this parameter you define the nomi 0 ... 64 2

    With this parameter you define the nomi 0 ... 64 1

    With this parameter you define the nomi 0 ... 64 1

    With this parameter you define the Aggr 1 ... 5 1

    With this parameter you define the Aggr 1 ... 5 1

    With this parameter you define the Aggr 1 ... 5 1

    With this parameter you define the Aggr 1 ... 5 1With this parameter you define the Aggr 1 ... 5 1

    With this parameter you define the maxi 0 ... 250 20

    With this parameter you define the maxi 0 ... 250 20

    With this parameter you define the maxi 0 ... 250 1

    With this parameter you define the maxi 0 ... 250 1

    With this parameter you define the maxi 0 ... 250 1

    With this parameter you define the maxi 0 ... 250 20

    With this parameter you define the Qual 0 ... 1000 400

    With this parameter you define the Qual 0 ... 1000 100

    With this parameter you define the Qual 0 ... 1000 200

    With this parameter you define the Qual 0 ... 1000 25

    This parameter is used to determine wh 0 ... 2 0

    With this parameter you define the thro 0 ... 100 50

    With this parameter you define the thro 0 ... 100 50

    With this parameter you define the thro 0 ... 100 50

    With this parameter you define the thro 0 ... 100 20

    With this parameter you define the thro 0 ... 100 20

    With this parameter you define the thro 0 ... 100 20

    With this parameter you define the thro 0 ... 100 20

    With this parameter you define the thro 0 ... 100 20

    With this parameter you define the thro 0 ... 100 20

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    12/85

    With this parameter you define the thro 0 ... 100 20

    With this parameter you define the thro 0 ... 100 20

    With this parameter you define the thro 0 ... 100 20

    With this parameter you define the thro 0 ... 100 10

    With this parameter you define the thro 0 ... 100 10

    With this parameter you define the thro 0 ... 100 10

    With this parameter you define the sche 1 ... 100 20

    With this parameter you define the sche 1 ... 100 10

    With this parameter you define the sche 1 ... 100 5

    With this parameter you define the sche 1 ... 100 20

    With this parameter you define the sche 1 ... 100 10

    With this parameter you define the sche 1 ... 100 5

    With this parameter you define the sche 1 ... 100 20

    With this parameter you define the sche 1 ... 100 10

    With this parameter you define the sche 1 ... 100 5

    With this parameter you define the sche 1 ... 100 20

    With this parameter you define the sche 1 ... 100 10

    With this parameter you define the sche 1 ... 100 5

    With this parameter you define the sche 1 ... 100 20With this parameter you define the sche 1 ... 100 10

    With this parameter you define the sche 1 ... 100 5

    This parameter identifies signallingPoint 0 ... 16777215 -

    This parameter identifies signallingPoint 0 ... 16777215 -

    This parameter identifies signallingPoint 0 ... 16777215 -

    This parameter identifies signallingPoint 0 ... 16777215 -

    With this parameter you switch on or off 0 ... 1 0

    With this parameter you define if the co 0 ... 1 1

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    13/85

    GUI value GUI Unit Data Base Value

    BSC Specific - BSC Specific

    BSC Specific - BSC Specific

    BSC Specific - BSC Specific

    20 % 2010 - 10

    80 % 80

    20 % 20

    100 - 100

    20 % 20

    20 % 20

    70 % 70

    30 s 30

    80 % 80

    100 % 100

    30 s 30

    150 - 150

    0 - 0000

    S11.5 - S11.5

    2 - 2

    2 - 2

    3 - 3

    Yes - 1

    No - 0

    disable emergency call setup on FACCH - 0

    6 - 6

    110 - 110

    30 - 30

    100 - 100

    33 dBm 5

    33 dBm 5

    Intercell - 0

    Intercell - 0

    30 - 30

    150 - 150

    100 - 100

    660 - 660

    660 - 660

    30 min 30

    120 min 120

    50 - 50

    660 - 660

    660 - 660

    120 min 120

    60 min 60

    60 min 60

    240 min 240

    4 - 4

    5 s 5

    release immediately - 255

    Template

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    14/85

    10 - 10

    30 - 30

    BSC Specific - BSC Specific

    18 - 18

    0 - 0

    8 - 8

    0 - 0

    6 - 6

    FALSE - 0

    disable answer to paging call setup on FACCH - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    GSM subscriber type - 0

    120 min 120

    120 min 120

    disable call re-establishment setup on FACCH - 0

    65535 min 65535

    5 - 5

    30 % 30

    100 % 100100 % 100

    100 % 100

    100 % 100

    100 % 100

    50 s 50

    FALSE - 0

    S11.5 - S11.5

    Currently used multirate - 1

    FALSE - 0

    FALSE - 0

    40 % 40

    60 % 60

    FALSE - 0

    95 % 95

    4 s 4

    - - -

    Any rate - 1

    255 s 255

    9 - 9

    7 - 7

    3 - 3

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    15/85

    12 - 12

    6 - 6

    3 - 3

    6 - 6

    9 - 9

    12 - 12

    slow LA - 0

    Actual Rate - 1

    BSC3i - 36

    - - -

    Only CSW used RTSLs are used - 0

    The GPRS territory is allocated first - 0

    10 - 10

    32 - 32

    25 % 25

    97 % 97

    3 - 3

    28 s 28

    5 s 5127 - 127

    128 s 128

    127 s 127

    TRUE - 1

    90 % 90

    30 - 30

    10 period 10

    1 h - 60

    0.5 - 5

    0 dB 0

    5 s 5

    16 dB 160 dB 0

    14 dB 14

    8 dB 8

    0 dB 0

    7 dB 7

    12 dB 12

    0 dB 0

    12 dB 12

    TCH With Highest C/I Level - 0

    14 dB 14

    0 dB 0

    12 dB 12

    14 dB 14

    0 dB 0

    14 dB 14

    50 ms 5

    ALL in MML - 0

    ALL in MML - 0

    FALSE - 0

    NCCR is disabled for all mobile stations. - 0

    15.36 s - 5

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    16/85

    6 s 6

    10 s 10

    10 s 10

    0.48 s - 0

    10 % 10

    90 % 90

    10 % 10

    70 % 70

    90 % 90

    2 kbit/s 2

    2 kbit/s 2

    2 kbit/s 2

    4 kbit/s 4

    4 kbit/s 4

    4 kbit/s 4

    4 kbit/s 4

    4 kbit/s 4

    4 kbit/s 4

    4 kbit/s 44 kbit/s 4

    4 kbit/s 4

    - - -

    2 kbit/s 2

    3 kbit/s 3

    5 kbit/s 5

    1 kbit/s 1

    1 kbit/s 1

    Interactive 1 - 2

    Legacy Streaming - 1

    Legacy Streaming - 1

    Interactive 1 - 2Legacy Streaming - 1

    20 0..250per mil 20

    20 0..250per mil 20

    1 0..250per mil 1

    1 0..250per mil 1

    1 0..250per mil 1

    20 0..250per mil 20

    400 - 400

    100 - 100

    200 - 200

    25 - 25

    not used - 0

    50 - 50

    50 - 50

    50 - 50

    20 - 20

    20 - 20

    20 - 20

    20 - 20

    20 - 20

    20 - 20

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    17/85

    20 - 20

    20 - 20

    20 - 20

    10 - 10

    10 - 10

    10 - 10

    20 - 20

    10 - 10

    5 - 5

    20 - 20

    10 - 10

    5 - 5

    20 - 20

    10 - 10

    5 - 5

    20 - 20

    10 - 10

    5 - 5

    20 - 2010 - 10

    5 - 5

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    FALSE - 0

    TRUE - 1

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    18/85

    BSC ID bscId NWP

    BCF ID bcfId NWP

    Address address NWP

    Administrative state adminState BAU

    Autoconfigure autoConfig NWP

    BTS Battery Backup Procedure batteryBackupProcedure NWP

    BCCH TRX Shutdown Timer bcchTrxBatbuTimer NWP

    External Outputs 1 bcfOutputInUse1 NWP

    Output Text 1 outputText1 NWP

    Text ID Of The Output 1 textId1 NWP

    External Outputs 2 bcfOutputInUse2 NWP

    Output Text 2 outputText2 NWP

    Text ID Of The Output 2 textId2 NWP

    External Outputs 3 bcfOutputInUse3 NWP

    Output Text 3 outputText3 NWP

    Text ID Of The Output 3 textId3 NWP

    External Outputs 4 bcfOutputInUse4 NWP

    Output Text 4 outputText4 NWP

    Text ID Of The Output 4 textId4 NWPExternal Outputs 5 bcfOutputInUse5 NWP

    Output Text 5 outputText5 NWP

    Text ID Of The Output 5 textId5 NWP

    External Outputs 6 bcfOutputInUse6 NWP

    Output Text 6 outputText6 NWP

    Text ID Of The Output 6 textId6 NWP

    Site Type bcfType NWP

    Lapd Link Name lapdLinkName NWP

    LAPD Link Number lapdLinkNumber NWP

    Latitude latitude NWP

    Longitude longitude NWP

    Master Clock TRX masterClock NWP

    Name name NWP

    TRX Shutdown Timer normTrxBatbuTimer NWPRX Difference Limit rxDifferenceLimit NWP

    Sync Mode syncMode NWP

    External Synchronization Source syncSource NWP

    Identification Of Test Equipment testEquipment NWP

    Site Id siteId -

    Clock Source clockSource NWP

    Synch Enabled synchEnabled NWP

    Master Clock BCF Identification masterClockBcf NWP

    Synch Status synchStatus NWP

    Connect Type connectSite NWP

    Slave BCF 1 slaveBcf1 NWP

    Slave BCF 2 slaveBcf2 NWP

    Slave BCF 3 slaveBcf3 NWP

    Slave BCF 4 slaveBcf4 NWPSlave BCF 5 slaveBcf5 NWP

    Slave BCF 6 slaveBcf6 NWP

    Slave BCF 7 slaveBcf7 NWP

    Slave BCF 8 slaveBcf8 NWP

    Full Name Database Abbreviation Class

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    19/85

    Definition Range & Step DB Nokia Default

    Identification (c-number) of BSC. NOTE 0 ... 999999 -

    With this parameter you identify the BC 1 ... 660 -

    Site Address where the physical BTS is - -

    With this parameter you lock or unlock t 1 ... 3 3

    With this parameter you define whether 0 ... 1 0

    With this parameter you define what typ 0 ... 2 0

    With this parameter you define the time 0 ... 3600000 0

    With this parameter you define the exte 0 ... 1 0

    With this parameter you define the exte - -

    With this parameter you define the text I 0 ... 200 -

    With this parameter you define the exte 0 ... 1 0

    With this parameter you define the exte - -

    With this parameter you define the text I 0 ... 200 -

    With this parameter you define the exte 0 ... 1 0

    With this parameter you define the exte - -

    With this parameter you define the text I 0 ... 200 -

    With this parameter you define the exte 0 ... 1 0

    With this parameter you define the exte - -

    With this parameter you define the text I 0 ... 200 -With this parameter you define the exte 0 ... 1 0

    With this parameter you define the exte - -

    With this parameter you define the text I 0 ... 200 -

    With this parameter you define the exte 0 ... 1 0

    With this parameter you define the exte - -

    With this parameter you define the text I 0 ... 200 -

    With this parameter you identify the typ 0 ... 5 0

    With this parameter you identify the D-c - -

    With this parameter you identify the D-c - -

    Absolute coordinate of the Antenna. - -

    Absolute coordinate of the antenna. - -

    With this parameter you define the mas 0 ... 16 0

    Adjacent cell name, same as target BT - -

    With this parameter you define the time 0 ... 3600000 0With this parameter you define the valu 3 ... 64 10

    With this parameter you define the sync 0 ... 255 -

    With this parameter you define the sync 0 ... 3 2

    With this parameter you define the test 0 ... 2 0

    Identifier (ID) of SITE object - -

    With this parameter you define the cloc 0 ... 4 0

    With this parameter you enable the syn 0 ... 1 0

    With this parameter you add the slave 0 ... 660 0

    This parameter indicates the synchronis 0 ... 4 0

    This parameter indicates whether the C - 0

    With this parameter you define the BCF -1 ... 660 0

    With this parameter you define the BCF -1 ... 660 0

    With this parameter you define the BCF -1 ... 660 0

    With this parameter you define the BCF -1 ... 660 0With this parameter you define the BCF -1 ... 660 0

    With this parameter you define the BCF -1 ... 660 0

    With this parameter you define the BCF -1 ... 660 0

    With this parameter you define the BCF -1 ... 660 0

    Information

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    20/85

    GUI value GUI Unit Data Base Value GUI value

    BCF Specific - BCF Specific BCF Specific

    BCF Specific - BCF Specific BCF Specific

    BCF Specific - BCF Specific BCF Specific

    BCF Specific - BCF Specific BCF Specific

    FALSE - 0 FALSE

    All Alive - 0 All Alive

    0 min 0 0

    FALSE - 0 FALSE

    - - - -

    - - - -

    FALSE - 0 FALSE

    - - - -

    - - - -

    FALSE - 0 FALSE

    - - - -

    - - - -

    FALSE - 0 FALSE

    - - - -

    - - - -FALSE - 0 FALSE

    - - - -

    - - - -

    FALSE - 0 FALSE

    - - - -

    - - - -

    BCF Specific - BCF Specific BCF Specific

    BCF Specific - BCF Specific BCF Specific

    BCF Specific - BCF Specific BCF Specific

    BCF Specific - BCF Specific BCF Specific

    BCF Specific - BCF Specific BCF Specific

    0 - 0 0

    BCF Specific - BCF Specific BCF Specific

    0 min 0 010 dB 10 10

    Independent - 2 Not Used

    PCM External - 2 PCM External

    No Test Equipment - 0 No Test Equipment

    - - - -

    NONE (remove clock source) - 0 BCF (master clock BCF)

    FALSE - 0 TRUE

    - - - Defined

    UNSYNCH - 0 BCFSYNCH

    NONE - 0 NONE

    - - - BCF Specific

    - - - -

    - - - -

    - - - -- - - -

    - - - -

    - - - -

    - - - -

    Outdoor Template (Standalone) Outdo

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    21/85

    GUI Unit Data Base Value GUI value GUI Unit

    - BCF Specific BCF Specific -

    - BCF Specific BCF Specific -

    - BCF Specific BCF Specific -

    - BCF Specific BCF Specific -

    - 0 FALSE -

    - 0 All Alive -

    min 0 0 min

    - 0 FALSE -

    - - - -

    - - - -

    - 0 FALSE -

    - - - -

    - - - -

    - 0 FALSE -

    - - - -

    - - - -

    - 0 FALSE -

    - - - -

    - - - -- 0 FALSE -

    - - - -

    - - - -

    - 0 FALSE -

    - - - -

    - - - -

    - BCF Specific BCF Specific -

    - BCF Specific BCF Specific -

    - BCF Specific BCF Specific -

    - BCF Specific BCF Specific -

    - BCF Specific BCF Specific -

    - 0 0 -

    - BCF Specific BCF Specific -

    min 0 0 mindB 10 10 dB

    - 0 Not Used -

    - 2 PCM External -

    - 0 No Test Equipment -

    - - - -

    - 2 NONE (remove clock source) -

    - 1 FALSE -

    - BCF Specific Defined -

    - 1 BCFSYNCH -

    - 0 NONE -

    - BCF Specific - -

    - - - -

    - - - -

    - - - -- - - -

    - - - -

    - - - -

    - - - -

    Outdoor Template (Slave-1800)r Template (Master-900)

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    22/85

    Data Base Value GUI value GUI Unit Data Base Value

    BCF Specific BCF Specific - BCF Specific

    BCF Specific BCF Specific - BCF Specific

    BCF Specific BCF Specific - BCF Specific

    BCF Specific BCF Specific - BCF Specific

    0 FALSE - 0

    0 All Alive - 0

    0 0 min 0

    0 FALSE - 0

    - - - -

    - - - -

    0 FALSE - 0

    - - - -

    - - - -

    0 FALSE - 0

    - - - -

    - - - -

    0 FALSE - 0

    - - - -

    - - - -0 FALSE - 0

    - - - -

    - - - -

    0 FALSE - 0

    - - - -

    - - - -

    BCF Specific BCF Specific - BCF Specific

    BCF Specific BCF Specific - BCF Specific

    BCF Specific BCF Specific - BCF Specific

    BCF Specific BCF Specific - BCF Specific

    BCF Specific BCF Specific - BCF Specific

    0 0 - 0

    BCF Specific BCF Specific - BCF Specific

    0 0 min 010 10 dB 10

    0 Independent - 2

    2 PCM External - 2

    0 No Test Equipment - 0

    - - - -

    0 ONE (remove clock sourc - 0

    0 FALSE - 0

    BCF Specific - - -

    1 UNSYNCH - 0

    0 NONE - 0

    - - - -

    - - - -

    - - - -

    - - - -- - - -

    - - - -

    - - - -

    - - - -

    IBS Template

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    23/85

    BSC ID bscId NWP

    BCF ID bcfId NWP

    BTS ID btsId NWP

    Administrative State adminState BAU

    Allow IMSI Attach Detach allowIMSIAttachDetach NWP

    BSIC BCC bsIdentityCodeBCC BAU

    BSIC NCC bsIdentityCodeNCC BAU

    Is BTS Frequency Hopping btsIsHopping NWP

    BTS Load Threshold btsLoadThreshold NWP

    BTS Measure Average btsMeasAver NWP

    Call Reestablishment Allowed callReestablishmentAllowed NWP

    Cell Bar Qualify cellBarQualify NWP

    Cell Barred cellBarred NWP

    CI cellId NWP

    Cell Load for Channel Search cellLoadForChannelSearch SOP

    Cell Reselect Hysteresis cellReselectHysteresis SOP

    Cell Reselect Offset cellReselectOffset SOP

    Cell Reselection Parameter Index cellReselectParamInd SOP

    C Threshold cnThreshold NWP

    Diversity Used diversityUsed NWP

    HSCSD Downgrade Guard Time downgradeGuardTimeHSCSD NWP

    Directed Retry Used drInUse NWP

    Directed Retry Method drMethod NWP

    DTX Mode dtxMode NWP

    Early Sending Indication earlySendingIndication NWP

    Emergency Call Restricted emergencyCallRestricted NWP

    Limit For Free TCHs freeTchLimit NWP

    Cell Type cellType NWP

    BTS Hopping Mode hoppingMode NWP

    Hopping Sequence Number 1 hoppingSequenceNumber1 BAU

    Hopping Sequence Number 2 hoppingSequenceNumber2 NWP

    Underlay Hopping Sequence Number hoppingSequenceNumber3 NWP

    Idle State BCCH Allocation List (BAL) ID In Use idleStateBcchAllocIdUsed NWP

    Idle State BCCH Allocation List (BAL) ID idleStateBcchAllocListId NWPIDR Cell Type idrCellType NWP

    Intelligent Directed Retry Used idrUsed NWP

    InSite Gateway insiteGateway NWP

    InSite Group insiteGroup NWP

    Averaging Period interferenceAveragingProcessAverPeriod SOP

    Interference Averaging Boundary 0 interferenceAveragingProcessBoundary0 SOP

    Interference Averaging Boundary 1 interferenceAveragingProcessBoundary1 SOP

    Interference Averaging Boundary 2 interferenceAveragingProcessBoundary2 SOP

    Interference Averaging Boundary 3 interferenceAveragingProcessBoundary3 SOP

    Interference Averaging Boundary 4 interferenceAveragingProcessBoundary4 SOP

    Interference Averaging Boundary 5 interferenceAveragingProcessBoundary5 SOP

    LAC locationAreaIdLAC SOP

    MCC locationAreaIdMCC NWP

    MNC locationAreaIdMNC NWPHSCSD Cell Load Lower Limit lowerLimitCellLoadHSCSD NWP

    MAIO Offset maioOffset NWP

    MAIO Step maioStep NWP

    Max Number of Repetition maxNumberOfRepetition NWP

    Max Number Of Retransmission maxNumberRetransmission NWP

    Max Queue Length maxQueueLength NWP

    Max Time Limit Directed Retry maxTimeLimitDirectedRetry NWP

    BCCH Allocation Usage For Active MS measurementBCCHAllocation NWP

    HSCSD Minimum Exhaust minExhaustHSCSD NWP

    HSCSD TCH Capacity Minimum minHSCSDcapacityCell NWP

    Full Name Database Abbreviation Class

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    24/85

    MS Tx Pwr Min minMsTxPower NWP

    Min Time Limit Directed Retry minTimeLimitDirectedRetry NWP

    MS Max Distance in Call Setup msMaxDistInCallSetup NWP

    MS Priority Used msPriorityUsedInQueueing NWP

    MS Tx Pwr Max CCH msTxPwrMaxCCH NWP

    Adjacency on Other Band multiBandCell NWP

    Multiband Cell Reporting multiBandCellReporting NWP

    Number of Slots Spread Trans nbrOfSlotsSpreadTrans NWP

    Number Of TCH Reserved For Priority Subscribers Onl nbrTchForPrioritySubs NWP

    New Establishment Causes Support newEstabCausesSupport NWP

    Number Of Blocks For Access Grant Msg noOfBlocksForAccessGrant NWP

    Number Of Multiframes noOfMFramesBetweenPaging NWP

    Not Allowed Access Classes 1 notAllowedAccessClasses1 NWP

    Not Allowed Access Classes 2 notAllowedAccessClasses2 NWP

    Not Allowed Access Classes 3 notAllowedAccessClasses3 NWP

    Not Allowed Access Classes 4 notAllowedAccessClasses4 NWP

    Not Allowed Access Classes 5 notAllowedAccessClasses5 NWP

    Not Allowed Access Classes 6 notAllowedAccessClasses6 NWP

    Not Allowed Access Classes 7 notAllowedAccessClasses7 NWP

    Not Allowed Access Classes 8 notAllowedAccessClasses8 NWP

    Not Allowed Access Classes 9 notAllowedAccessClasses9 NWP

    Not Allowed Access Classes 10 notAllowedAccessClasses10 NWP

    Not Allowed Access Classes 11 notAllowedAccessClasses11 NWP

    Not Allowed Access Classes 12 notAllowedAccessClasses12 NWP

    Not Allowed Access Classes 13 notAllowedAccessClasses13 NWP

    Not Allowed Access Classes 14 notAllowedAccessClasses14 NWP

    Not Allowed Access Classes 15 notAllowedAccessClasses15 NWP

    Not Allowed Access Classes 16 notAllowedAccessClasses16 NWP

    Penalty Time penaltyTime SOP

    PLMN Permitted 1 plmnPermitted1 NWP

    PLMN Permitted 2 plmnPermitted2 NWP

    PLMN Permitted 3 plmnPermitted3 NWP

    PLMN Permitted 4 plmnPermitted4 NWP

    PLMN Permitted 5 plmnPermitted5 NWP

    PLMN Permitted 6 plmnPermitted6 NWPPLMN Permitted 7 plmnPermitted7 NWP

    PLMN Permitted 8 plmnPermitted8 NWP

    Power Offset powerOffset NWP

    Restricted Use Of Priority Channels In Incoming HO priorityChUseIncomingHO NWP

    Queueing Priority Call queueingPriorityCall NWP

    Queueing Priority Urgent Handover queueingPriorityHandover NWP

    Queueing Priority Non-Urgent Handover queuePriorityNonUrgentHo NWP

    Queue Priority Used queuePriorityUsed NWP

    Radio Link Timeout radioLinkTimeout SOP

    Radius Extension radiusExtension NWP

    Reservation Method Used In Trunk Reservation reservationMethod NWP

    Rxlev Access Min rxLevAccessMin SOP

    SMS CB Used smsCbUsed NWP

    Softblocking Threshold On Regular Frequencies softBlockingStartReg NWPSoftblocking Threshold On Super-Reuse Frequencies softBlockingStartSup NWP

    Temporary Offset temporaryOffset SOP

    Time Limit Call timeLimitCall NWP

    Time Limit Handover timeLimitHandover NWP

    Timer For Periodic MS Location Updating timerPeriodicUpdateMs NWP

    Traffic Types 1 trafficTypesForTrunk1 NWP

    Traffic Types 2 trafficTypesForTrunk2 NWP

    Traffic Types 3 trafficTypesForTrunk3 NWP

    Traffic Types 4 trafficTypesForTrunk4 NWP

    Traffic Types 5 trafficTypesForTrunk5 NWP

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    25/85

    Traffic Types 6 trafficTypesForTrunk6 NWP

    Traffic Types 7 trafficTypesForTrunk7 NWP

    Traffic Types 8 trafficTypesForTrunk8 NWP

    Traffic Types 9 trafficTypesForTrunk9 NWP

    Traffic Types 10 trafficTypesForTrunk10 NWP

    Trunk Reservation Used trunkReservationUsed NWP

    TRX Priority in TCH Allocation trxPriorityInTchAlloc NWP

    Underlay BTS Hopping Mode underlayHoppingMode NWP

    Underlay MAL ID underlayMaAllocationId NWP

    Underlay MAL ID Used underlayMaIdUsed NWP

    Underlay MAIO Offset underlayMaioOffset NWP

    Underlay MAIO Step underlayMaioStep NWP

    HSCSD Upgrade Gain upgradeGainHSCSD NWP

    HSCSD Upgrade Guard Time upgradeGuardTimeHSCSD NWP

    HSCSD Cell Load Upper Limit upperLimitCellLoadHSCSD NWP

    HSCSD Regular Cell Load Upper Limit upperLimitRegularLoadHSCSD NWP

    Used MAL ID usedMobileAllocation BAU

    Used MAL ID In Use usedMobileAllocIdUsed NWP

    AMR FR Codec Mode Set amrConfFrCodecModeSet NWP

    AMR FR Hysteresis 1 amrConfFrHysteresis1 NWP

    AMR FR Hysteresis 2 amrConfFrHysteresis2 NWP

    AMR FR Hysteresis 3 amrConfFrHysteresis3 NWP

    AMR FR Initial Codec Mode Indicator amrConfFrInitCodecMode NWP

    AMR FR Start Mode amrConfFrStartMode NWP

    AMR FR Threshold 1 amrConfFrThreshold1 NWP

    AMR FR Threshold 2 amrConfFrThreshold2 NWP

    AMR FR Threshold 3 amrConfFrThreshold3 NWP

    AMR HR Codec Mode Set amrConfHrCodecModeSet NWP

    AMR HR Hysteresis 1 amrConfHrHysteresis1 NWP

    AMR HR Hysteresis 2 amrConfHrHysteresis2 NWP

    AMR HR Hysteresis 3 amrConfHrHysteresis3 NWP

    AMR HR Initial Codec Mode Indicator amrConfHrInitCodecMode NWP

    AMR HR Start Mode amrConfHrStartMode NWP

    AMR HR Threshold 1 amrConfHrThreshold1 NWP

    AMR HR Threshold 2 amrConfHrThreshold2 NWPAMR HR Threshold 3 amrConfHrThreshold3 NWP

    Intra HO Threshold Rx Qual AMR FR amrHoFrInHoThrDlRxQual NWP

    Super Reuse Bad C/I Threshold AMR FR amrHoFrSupReuBadCiThr NWP

    Super Reuse Good C/I Threshold AMR FR amrHoFrSupReuGoodCiThr NWP

    Threshold Dl Rx Qual For AMR FR amrHoFrThrDlRxQual NWP

    Threshold Ul Rx Qual AMR FR amrHoFrThrUlRxQual NWP

    Amr Handover Hr Intra Threshold Dl Rx Qual amrHoHrInHoThrDlRxQual NWP

    Super Reuse Bad C/I Threshold AMR HR amrHoHrSupReuBadCiThr NWP

    Super Reuse Good C/I Threshold AMR HR amrHoHrSupReuGoodCiThr NWP

    Threshold Dl Rx Qual AMR HR amrHoHrThrDlRxQual NWP

    Threshold Ul Rx Qual AMR HR amrHoHrThrUlRxQual NWP

    PC Lower Threshold Dl Rx Qual AMR FR amrPocFrPcLThrDlRxQual NWP

    PC Lower Threshold Ul Rx Qual AMR FR amrPocFrPcLThrUlRxQual NWP

    Pc Upper Threshold Dl Rx Qual AMR FR amrPocFrPcUThrDlRxQual NWPPc Upper Threshold Ul Rx Qual AMR FR amrPocFrPcUThrUlRxQual NWP

    PC Lower Threshold Dl Rx Qual AMR HR amrPocHrPcLThrDlRxQual NWP

    PC Lower Threshold Ul Rx Qual AMR HR amrPocHrPcLThrUlRxQual NWP

    Pc Upper Threshold Dl Rx Qual AMR HR amrPocHrPcUThrDlRxQual NWP

    Pc Upper Threshold Ul Rx Qual AMR HR amrPocHrPcUThrUlRxQual NWP

    BTS Load In SEG btsLoadInSeg SOP

    Lower Limit For FR TCH Resources btsSpLoadDepTchRateLower SOP

    Upper Limit For FR TCH Resources btsSpLoadDepTchRateUpper SOP

    Upper Limit For FR TCH Resources frequencyBandInUse NWP

    MS TX Pwr Max GSM msTxPwrMaxGSM NWP

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    26/85

    MS Tx Pwr Max GSM 1x00 msTxPwrMaxGSM1x00 NWP

    Master BTS for Multi BCF masterBcf NWP

    Non BCCH Layer Offset nonBCCHLayerOffset BAU

    Segment ID segmentId NWP

    Segment Name segmentName NWP

    TCH Rate Intra-Cell Handover tchRateIntraCellHo NWP

    GPRS Fdd Cell Reselect Offset fddGprsQOffset SOP

    FDD Cell Reselect Offset fddQOffset SOP

    Minimum FDD Threshold fddQMin SOP

    GPRS Minimum FDD Threshold gprsFddQMin SOP

    MS Tx Pwr Max CCH 1x00 msTxPwrMaxCCH1x00 NWP

    Threshold To Search WCDMA RAN Cells qSearchI SOP

    GPRS Threshold To Search WCDMA RAN Cells qSearchP SOP

    AMH Upper Load Threshold amhUpperLoadThreshold NWP

    AMH Lower Load Threshold amhLowerLoadThreshold NWP

    AMH Max Load Of Target Cell amhMaxLoadOfTgtCell NWP

    TRHO Guard Time amhTrhoGuardTime NWP

    Antenna Hopping antennaHopping NWP

    Scale Ord scaleOrd NWP

    Measurement BCCH Allocation List measListUsedDuringMeas NWP

    Adjacent Cells Update Info adjUpdateInfo NWP

    Adaptive LA Algorithm adaptiveLaAlgorithm NWP

    BSC-BSC Interface Status bscBscInterfaceStatus NWP

    Coding Schemes CS3 And CS4 Enabled cs3Cs4Enabled NWP

    DFCA Mode dfcaMode NWP

    DFCA Unsynchronized Mode MA Frequency List dfcaUnsyncModeMaList NWP

    DL Noise Level dlNoiseLevel NWP

    Forced AMR HR Mode C/I Threshold forcedAmrHrCiThreshold NWP

    Forced HR Mode C/I Averaging Period forcedHrCiAverPeriod NWP

    Forced HR Mode C/I Threshold forcedHrCiThreshold NWP

    Forced HR Mode Hysteresis forcedHrModeHysteresis NWP

    IMSI Based Handover GSM Enabled ibhoGsmEnabled NWP

    IMSI Based Handover WCDMA Enabled ibhoWcdmaEnabled NWP

    DL Coding Scheme In Acknowledged Mode csAckDl NWP

    UL Coding Scheme In Acknowledged Mode csAckUl NWPDL Coding Scheme In Unacknowledged Mode csUnackDl NWP

    UL Coding Scheme In Unacknowledged Mode csUnackUl NWP

    AMR Radio Link Timeout radioLinkTimeoutAmr SOP

    UL Noise Level ulNoiseLevel NWP

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    27/85

    Identification (c-number) of BSC. NOTE 0 ... 999999 -

    With this parameter you identify the BC 1 ... 660 -

    Identification (ID) of BTS object: either i 1 ... 660 -

    With this parameter you lock or unlock t 1 ... 3 3

    With this parameter you define whether 0 ... 1 1

    With this parameter you identify the BT 0 ... 7 -

    With this parameter you identify the net 0 ... 7 -

    This attribute contains a boolean value i 0 ... 1 0

    With this parameter you define which pr 0 ... 100 70

    With this parameter you define how ma 1 ... 4 1

    With this parameter you define whether 0 ... 1 0

    With this parameter you define whether 0 ... 1 0

    With this parameter you define whether 0 ... 1 0

    With this parameter you identify the cell 1 ... 65535 -

    With this parameter you give a load limi 0 ... 100 0

    With this parameter you define the recei 0 ... 7 2

    With this parameter you define the offse 0 ... 63 0

    With this parameter you define whether 0 ... 1 0

    With this parameter you define the mini 0 ... 63 0

    With this parameter you define whether 0 ... 2 0

    With this parameter you determine the 0 ... 65535 0

    With this parameter you define if the dir 0 ... 1 0

    With this parameter you define which m 0 ... 1 0

    With this parameter you define how the 0 ... 2 2

    With this parameter you accept or forbi 0 ... 1 1

    With this parameter you define if an em 0 ... 1 0

    With this parameter you define the num 1 ... 16 16

    With this parameter you define the adja 0 ... 1 0

    With this parameter you define the freq 0 ... 2 0

    With this parameter you define whether 0 ... 63 0

    With this parameter you define whether 0 ... 63 0

    With this parameter you define whether 0 ... 63 0

    Indicates whether an idle state list or ca 0 ... 1 -

    With this parameter you define the BCC 0 ... 660 0IDR type of cell. NOTE: MML descriptio 0 ... 1 0

    With this parameter you define if the dir 0 ... 1 0

    Defines whether the InSite BTS is an In 0 ... 2 0

    Defines the group in the Office where th 0 ... 999 0

    With this parameter you define the num 1 ... 32 6

    With these parameters you define the b 0 0

    With these parameters you define the b 0 ... 63 5

    With these parameters you define the b 0 ... 63 10

    With these parameters you define the b 0 ... 63 15

    With these parameters you define the b 0 ... 63 20

    With these parameters you define the b 63 ... 63 63

    With this parameter you identify the loc 1 ... 65533 -

    With this parameter you identify the mo - -

    With this parameter you identify the loc - -With this parameter you determine the l 0 ... 100 100

    With this parameter you set the MAIO o 0 ... 62 0

    With this parameter you choose the MA 1 ... 62 1

    With this parameter you define the maxi 5 ... 35 5

    With this parameter you define the maxi 1 ... 7 4

    With this parameter you define how ma 0 ... 100 50

    With this parameter you define the maxi 1 ... 15 5

    With this parameter you define the BCC 0 ... 1 1

    With this parameter you determine how 1 ... 4 1

    With this parameter you determine the 0 ... 100 100

    Information

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    28/85

    With this parameter you define the mini 0 ... 31 19

    With this parameter you define the peri 0 ... 14 0

    With this parameter you define the maxi 0 ... 255 255

    With this parameter you define whether 0 ... 1 1

    With this parameter you define the maxi 0 ... 19 5

    With this parameter you define whether 0 ... 1 1

    With this parameter you define the num 0 ... 3 1

    With this parameter you define the num 0 ... 15 7

    With this parameter you define the num 0 ... 8 0

    With this parameter you define whether 0 ... 1 0

    With this parameter you define the num 0 ... 7 1

    With this parameter you define the num 2 ... 9 4

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the MS 0 ... 1 0

    With this parameter you define the dura 0 ... 31 0

    With this parameter you define to which 0 ... 1 -

    With this parameter you define to which 0 ... 1 -

    With this parameter you define to which 0 ... 1 -

    With this parameter you define to which 0 ... 1 -

    With this parameter you define to which 0 ... 1 -

    With this parameter you define to which 0 ... 1 -With this parameter you define to which 0 ... 1 -

    With this parameter you define to which 0 ... 1 -

    With this parameter you define the maxi 0 ... 3 0

    With this parameter you define if the pri 0 ... 1 0

    With this parameter you define the call 1 ... 14 10

    With this parameter you define the urge 1 ... 14 9

    With this parameter you define the non- 1 ... 14 9

    With this parameter you define whether 0 ... 1 1

    With this parameter you define the maxi 0 ... 15 4

    With this parameter you define the radi 0 ... 67 0

    With this parameter you define which re 0 ... 1 0

    With this parameter you define the mini 0 ... 63 5

    With this parameter you allow or deny c 0 ... 1 0

    With this parameter you define the thre 0 ... 255 255With this parameter you define the thre 0 ... 255 255

    With this parameter you define the neg 0 ... 7 0

    With this parameter you define the maxi 0 ... 15 10

    With this parameter you define the maxi 0 ... 10 5

    With this parameter you define the inter 0 ... 255 5

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define the spec -1 ... 64 -

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    29/85

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define the spec -1 ... 64 -

    With this parameter you define whether 0 ... 1 0

    With this parameter you define whether 0 ... 3 0

    With this parameter you define the freq 0 ... 2 0

    With this parameter you define the mobi 0 ... 660 0

    With this parameter you define the mobi 0 ... 1 0

    With this parameter you set the lowest 0 ... 62 0

    With this parameter you choose the MA 1 ... 62 1

    With this parameter you determine the 0 ... 100 0

    With this parameter you determine the 0 ... 65535 0

    With this parameter you determine the 0 ... 100 100

    With this parameter you determine the 0 ... 100 100

    With this parameter you define the mobi 0 ... 660 0

    Indicates whether mobile allocation is u 0 ... 1 -

    With this parameter you define the code 0 ... 255 21

    With this parameter, together with AMR 0 ... 15 2

    With this parameter, together with AMR 0 ... 15 2

    With this parameter, together with the A 0 ... 15 2

    With this parameter you define whether 0 ... 1 0

    With this parameter you define explicitly 0 ... 3 0

    With this parameter you define the thre 0 ... 63 8

    With this parameter you define the thre 0 ... 63 14

    With this parameter you define the thre 0 ... 63 22

    With this parameter you define the code 0 ... 31 0

    With this parameter you define together 0 ... 15 2

    With this parameter, together with the A 0 ... 15 2

    With this parameter, together with the A 0 ... 15 0

    With this parameter you define whether 0 ... 1 0

    With this parameter you explicitly define 0 ... 3 0

    With this parameter you define the thre 0 ... 63 22

    With this parameter you define the thre 0 ... 63 28With this parameter you define the thre 0 ... 63 0

    With this parameter you define the thre 0 ... 7 0

    With this parameter you define the dow -127 ... 127 10

    With this parameter you define the dow -127 ... 127 17

    With this parameter you define the thre 0 ... 7 4

    With this parameter you define the thre 0 ... 7 4

    Defines AMR Handover Intra Threshold 0 ... 7 4

    With this parameter you define the dow -127 ... 127 10

    With this parameter you define the dow -127 ... 127 17

    With this parameter you define the thre 0 ... 7 4

    With this parameter you define the thre 0 ... 7 4

    With this parameter you define the thre 0 ... 7 3

    With this parameter you define the thre 0 ... 7 3

    With this parameter you define the thre 0 ... 7 0With this parameter you define the thre 0 ... 7 0

    With this parameter you define the thre 0 ... 7 3

    With this parameter you define the thre 0 ... 7 3

    With this parameter you define the thre 0 ... 7 0

    With this parameter you define the thre 0 ... 7 0

    With this parameter you determine the l 0 ... 100 70

    With this parameter you define the perc 0 ... 100 100

    With this parameter you define the perc 0 ... 100 0

    With this parameter you define the type 0 ... 5 0

    With this parameter you define the maxi 0 ... 19 5

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    30/85

    With this parameter you define the maxi 0 ... 31 0

    The attribute identifies if the BTS is Ma 0 ... 1 -

    With this parameter you define whether -40 ... 40 0

    With this parameter you identify the seg 1 ... 660 -

    With this parameter you identify the seg - -

    With this parameter you control the TC 0 ... 4 0

    With this parameter you define a WCD 0 ... 15 0

    With this parameter you define a WCD 0 ... 15 0

    This parameter defines a minimum Ec/I 0 ... 7 7

    This parameter defines a minimum Ec//I 0 ... 7 7

    With this parameter you define the maxi 0 ... 31 0

    With this parameter you define the thre - 15

    With this parameter you define the thre - -

    With this parameter you define the upp 0 ... 100 80

    With this parameter you define the lowe 0 ... 100 20

    With this advanced multilayer handling 0 ... 100 70

    With this parameter you define the guar 0 ... 120 30

    With this parameter you define whether 0 ... 1 0

    With this parameter you define whether 0 ... 2 0

    With this parameter you define whether 0 ... 1 1

    With this parameter you define whether 0 ... 1 1

    With this parameter the operator can de 0 ... 1 0

    This parameter indicates if the DFCA al 0 ... 1 0

    With this parameter you can define whe 0 ... 1 0

    With this parameter you define the oper 0 ... 2 0

    With this parameter you define the DFC 0 ... 660 0

    With this parameter you define a BTS-s 0 ... 40 3

    If the BTS level average C/I is below th 0 ... 63 0

    With this parameter you define the peri 5 ... 30 15

    If the BTS level average C//I is below th 0 ... 63 0

    With this parameter you define how ma 0 ... 63 3

    With this parameter you define whether 0 ... 1 0

    With this parameter you define whether 0 ... 1 0

    With this parameter you can define the i 0 ... 7 1

    With this parameter you can define the i 0 ... 7 1With this parameter you can define the i 0 ... 7 1

    With this parameter you can define the i 0 ... 7 1

    With this parameter you define the maxi 0 ... 15 4

    With this parameter you define a BTS-s 0 ... 40 3

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    31/85

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    TRUE - 1

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    TRUE - 1

    70 % 70

    1 - 1

    FALSE - 0

    FALSE - 0

    FALSE - 0

    BTS Specific - BTS Specific

    0 % 0

    4 dB 2

    0 dB 0

    FALSE - 0

    0 - 0

    On - 1

    0 s 0

    TRUE - 1

    Basic - 0

    MS shall use DTX - 1

    TRUE - 1

    FALSE - 0

    16 - 16

    GSM - 0

    RF-Hopping - 2

    BTS Specific - BTS Specific

    0 - 0

    0 - 0

    FALSE - 0

    1 - 1GSM - 0

    FALSE - 0

    In/Out Gateway - 2

    - 0

    6 - 6

    0 - 0

    5 dBm 5

    10 dBm 10

    15 dBm 15

    20 dBm 20

    63 - 63

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific100 % 100

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    5 - 5

    4 - 4

    50 % 50

    5 s 5

    Adjacent Cells BCCHs - 1

    Release 1 - 1

    100 % 100

    Outdoor Template

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    32/85

    19 (900); 15 (1800) - 19 (900); 15 (1800)

    0 s 0

    255 0..255*550m 255

    TRUE - 1

    33 - 5

    TRUE - 1

    1 - 1

    10 - 7

    0 - 0

    FALSE - 0

    1 - 1

    4 - 4

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    0 s 0

    TRUE - 1

    TRUE - 1

    TRUE - 1

    TRUE - 1

    TRUE - 1

    TRUE - 1TRUE - 1

    TRUE - 1

    0 dBm 0

    Only For Priority Subscriber - 0

    10 - 10

    9 - 9

    9 - 9

    TRUE - 1

    24 SACCH 5

    0 km 0

    DYN - 0

    -101 dBm 9

    TRUE - 1

    255 - 255255 - 255

    0 dB 0

    10 s 10

    5 s 5

    4 h 40

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    0 - 0

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    33/85

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    FALSE - 0

    Beyond BCCH TRX - 2

    Not Used - 0

    1 - 1

    FALSE - 0

    0 - 0

    1 - 1

    Gain Not Used - 0

    0 s 0

    100 % 100

    100 % 100

    BTS Specific - BTS Specific

    1 - 1

    149 - 149

    1 - 2

    1 - 2

    1 - 2

    Define by implicit rule provided in GSM 05.09 - 0

    Codec Mode 1 - 0

    4 - 8

    7 - 14

    11 - 22

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    Define by implicit rule provided in GSM 05.09 - 0

    Codec Mode 1 - 0

    0 - 0

    0 - 00 - 0

    < 0.2% - 0

    10 - 10

    17 - 17

    1.6% ... 3.2% - 4

    1.6% ... 3.2% - 4

    1.6% ... 3.2% - 4

    10 - 10

    17 - 17

    1.6% ... 3.2% - 4

    1.6% ... 3.2% - 4

    0.8% ... 1.6% - 3

    0.8% ... 1.6% - 3

    < 0.2% - 0< 0.2% - 0

    0.8% ... 1.6% - 3

    0.8% ... 1.6% - 3

    < 0.2% - 0

    < 0.2% - 0

    100 (Standalone) ; 30 (900) ; 70 (1800) % 100 (Standalone) ; 30 (900) ; 70 (1800)

    100 % 100

    0 % 0

    BTS Specific - BTS Specific

    33 - 5

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    34/85

    30 dBm 0

    BTS Specific - BTS Specific

    0(900), 6(1800) - 0(900), 6(1800)

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    No Constraints - 0

    -32 dB 0

    -32 dB 0

    -14 dB - 6

    -14 dB - 6

    30 - 0

    Infinity (always) - 7

    Infinity (always) - 7

    Undefined -1, 0..100% -1

    Undefined -1, 0..100% -1

    Undefined -1, 0..100% -1

    Not defined - -1

    FALSE - 0

    NO - 0

    TRUE - 1

    FALSE - 0

    Adaptive LA algorithm is enabled - 0

    Ok - 0

    FALSE - 0

    Off - 0

    0 0, 1..2000 0

    -117 dB 3

    0 dB 0

    15 min 15

    0 dB 0

    3 dB 3

    FALSE - 0

    FALSE - 0

    CS2 - 1

    CS2 - 1CS2 - 1

    CS2 - 1

    20 SACCH 4

    -117 dB 3

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    35/85

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    TRUE - 1

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    TRUE - 1

    70 % 70

    1 - 1

    FALSE - 0

    FALSE - 0

    FALSE - 0

    BTS Specific - BTS Specific

    0 % 0

    4 dB 2

    0 dB 0

    TRUE - 1

    0 - 0

    On - 1

    0 s 0

    FALSE - 0

    Basic - 0

    MS shall use DTX - 1

    TRUE - 1

    FALSE - 0

    16 - 16

    GSM - 0

    Non Hopping - 0

    BTS Specific - BTS Specific

    0 - 0

    0 - 0

    FALSE - 0

    1 - 1GSM - 0

    FALSE - 0

    In/Out Gateway - 2

    - 0

    6 - 6

    0 - 0

    5 dBm 5

    10 dBm 10

    15 dBm 15

    20 dBm 20

    63 - 63

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific100 % 100

    0 - 0

    1 - 1

    5 - 5

    4 - 4

    50 % 50

    5 s 5

    Adjacent Cells BCCHs - 1

    Release 1 - 1

    100 % 100

    IBS Template

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    36/85

    15 - 15

    0 s 0

    1 0..255*550m 1

    TRUE - 1

    33 - 5

    TRUE - 1

    3 - 3

    10 - 7

    0 - 0

    FALSE - 0

    1 - 1

    4 - 4

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    0 s 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    FALSE - 0

    TRUE - 1FALSE - 0

    TRUE - 1

    0 dBm 0

    Only For Priority Subscriber - 0

    10 - 10

    9 - 9

    9 - 9

    TRUE - 1

    20 SACCH 4

    0 km 0

    DYN - 0

    -101 dBm 9

    FALSE - 0

    255 - 255255 - 255

    0 dB 0

    10 s 10

    5 s 5

    4 h 40

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    0 - 0

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    37/85

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    FALSE - 0

    Beyond BCCH TRX - 2

    Not Used - 0

    1 - 1

    FALSE - 0

    0 - 0

    1 - 1

    Gain Not Used - 0

    0 s 0

    100 % 100

    100 % 100

    BTS Specific - BTS Specific

    1 - 1

    149 - 149

    1 - 2

    1 - 2

    1 - 2

    y implicit rule provided in GS - 0

    Codec Mode 1 - 0

    4 - 8

    7 - 14

    11 - 22

    0 - 0

    0 - 0

    0 - 0

    0 - 0

    y implicit rule provided in GS - 0

    Codec Mode 1 - 0

    0 - 0

    0 - 00 - 0

    < 0.2% - 0

    10 - 10

    17 - 17

    1.6% ... 3.2% - 4

    1.6% ... 3.2% - 4

    1.6% ... 3.2% - 4

    10 - 10

    17 - 17

    1.6% ... 3.2% - 4

    1.6% ... 3.2% - 4

    0.8% ... 1.6% - 3

    0.8% ... 1.6% - 3

    < 0.2% - 0< 0.2% - 0

    0.8% ... 1.6% - 3

    0.8% ... 1.6% - 3

    < 0.2% - 0

    < 0.2% - 0

    100 % 100

    100 % 100

    0 % 0

    BTS Specific - BTS Specific

    33 - 5

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    38/85

    30 dBm 0

    Master - 1

    0 - 0

    BTS Specific - BTS Specific

    BTS Specific - BTS Specific

    No Constraints - 0

    0 dB 8

    0 dB 8

    -14 dB - 6

    -14 dB - 6

    30 - 0

    Infinity (always) - 7

    Infinity (always) - 7

    Undefined -1, 0..100% -1

    Undefined -1, 0..100% -1

    Undefined -1, 0..100% -1

    Not defined - -1

    FALSE - 0

    NO - 0

    TRUE - 1

    FALSE - 0

    aptive LA algorithm is enabl - 0

    Ok - 0

    FALSE - 0

    Off - 0

    0 0, 1..2000 0

    -117 dB 3

    0 dB 0

    15 min 15

    0 dB 0

    3 dB 3

    FALSE - 0

    FALSE - 0

    CS2 - 1

    CS2 - 1CS2 - 1

    CS2 - 1

    20 SACCH 4

    -117 dB 3

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    39/85

    BSC ID bscId

    BCF ID bcfId

    BTS ID btsId

    GPRS Enabled gprsEnabled

    RAC rac

    Dedicated GPRS Capacity dedicatedGPRScapacity

    Default GPRS Capacity defaultGPRScapacity

    Prefer BCCH TRXs in GPRS TCHs allocation preferBCCHfreqGPRS

    NSEI nsei

    GPRS Number Of Slots Spread Transmission gprsNbrSlotsSpreadTrans

    Calculation Of Minimum Number Of Slots calcMinNumberSlots

    GPRS Max Number Of Retransmission 1 gprsMaxRetrans1

    GPRS Max Number Of Retransmission 2 gprsMaxRetrans2

    GPRS Max Number Of Retransmission 3 gprsMaxRetrans3

    GPRS Max Number Of Retransmission 4 gprsMaxRetrans4

    GPRS Not Allowed Access Classes 1 gprsAccessCtrlClass1

    GPRS Not Allowed Access Classes 2 gprsAccessCtrlClass2

    GPRS Not Allowed Access Classes 3 gprsAccessCtrlClass3

    GPRS Not Allowed Access Classes 4 gprsAccessCtrlClass4GPRS Not Allowed Access Classes 5 gprsAccessCtrlClass5

    GPRS Not Allowed Access Classes 6 gprsAccessCtrlClass6

    GPRS Not Allowed Access Classes 7 gprsAccessCtrlClass7

    GPRS Not Allowed Access Classes 8 gprsAccessCtrlClass8

    GPRS Not Allowed Access Classes 9 gprsAccessCtrlClass9

    GPRS Not Allowed Access Classes 10 gprsAccessCtrlClass10

    GPRS Not Allowed Access Classes 11 gprsAccessCtrlClass11

    GPRS Not Allowed Access Classes 12 gprsAccessCtrlClass12

    GPRS Not Allowed Access Classes 13 gprsAccessCtrlClass13

    GPRS Not Allowed Access Classes 14 gprsAccessCtrlClass14

    GPRS Not Allowed Access Classes 15 gprsAccessCtrlClass15

    GPRS Not Allowed Access Classes 16 gprsAccessCtrlClass16

    Gprs Rxlev Access Min gprsRxlevAccessMin

    GPRS Cell Reselect Hysteresis gprsCellReselHysteresisGprs Ms Txpwr Max CCH gprsMsTxpwrMaxCCH

    Ra Reselect Hysteresis raReselectHysteresis

    C31 Hysteresis c31Hysteresis

    C 32 Qual c32Qual

    Random Access Retry randomAccessRetry

    Reselection Time tResel

    PBCCH Blocks bsPBCCHBlocks

    PAGCH Blocks bsPagingBlocksRes

    PRACH Blocks bsPRACHBlocks

    Priority Class hcsPriorityClass

    HCS Threshold hcsThreshold

    Gprs Cell Barred gprsCellBarred

    DL BLER Crosspoint For CS Selection Hop pcuDlBlerCpHopping

    DL BLER Crosspoint For CS Selection No Hop pcuDlBlerCpNonHopDL adaption probability threshold pcuDlLaRiskLevel

    UL BLER Crosspoint For CS Selection Hop pcuUlBlerCpHopping

    UL BLER Crosspoint For CS Selection No Hop pcuUlBlerCpNonHop

    UL Adaption Probability Threshold pcuUlLaRiskLevel

    Coding Scheme Hop pcuCsHopping

    Coding Scheme No Hop pcuCsNonHopping

    GPRS Non BCCH Layer Rxlev Lower Limit gprsNonBCCHRxlevLower

    GPRS Non BCCH Layer Rxlev Upper Limit gprsNonBCCHRxlevUpper

    Direct GPRS Access Bts directGPRSAccessBts

    Max GPRS Capacity maxGPRSCapacity

    Full Name Database Abbreviation

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    40/85

    Egprs Enabled egprsEnabled

    Initial MCS For Acknowledged Mode egprsInitMcsAckMode

    Initial MCS For Unacknowledged Mode egprsInitMcsUnAckMode

    Maximum BLER In Acknowledged Mode egprsMaxBlerAckMode

    Maximum BLER In Unacknowledged Mode egprsMaxBlerUnAckMode

    Mean BEP Offset 8PSK egprsMeanBepOffset8psk

    Mean BEP Offset GMSK egprsMeanBepOffsetGmsk

    GPRS MS Txpwr Max CCH 1x00 gprsMsTxPwrMaxCCH1x00

    Prefer BCCH Frequency GPRS preferBCCHfreqGPRS2

    EGPRS Link Adaptation Enabled egprsLinkAdaptEnabled

    AC DL Min C/I Ratio Estimation acDlMinCiRatioEst

    AC Load Safety Margin acLoadSafetyMargin

    Background Traffic Class AC Load Threshold For ARP 1 acLoadThreshold_backgroundARP1

    Background Traffic Class AC Load Threshold For ARP 2 acLoadThreshold_backgroundARP2

    Background Traffic Class AC Load Threshold For ARP 3 acLoadThreshold_backgroundARP3

    Interactive 1 Traffic Class AC Load Threshold For ARP 1 acLoadThreshold_interactive1ARP1

    Interactive 1 Traffic Class AC Load Threshold For ARP 2 acLoadThreshold_interactive1ARP2

    Interactive 1 Traffic Class AC Load Threshold For ARP 3 acLoadThreshold_interactive1ARP3

    Interactive 2 Traffic Class AC Load Threshold For ARP 1 acLoadThreshold_interactive2ARP1

    Interactive 2 Traffic Class AC Load Threshold For ARP 2 acLoadThreshold_interactive2ARP2

    Interactive 2 Traffic Class AC Load Threshold For ARP 3 acLoadThreshold_interactive2ARP3

    Interactive 3 Traffic Class AC Load Threshold For ARP 1 acLoadThreshold_interactive3ARP1

    Interactive 3 Traffic Class AC Load Threshold For ARP 2 acLoadThreshold_interactive3ARP2

    Interactive 3 Traffic Class AC Load Threshold For ARP 3 acLoadThreshold_interactive3ARP3

    Streaming Traffic Class AC Load Threshold For ARP 1 acLoadThreshold_streamingARP1

    Streaming Traffic Class AC Load Threshold For ARP 2 acLoadThreshold_streamingARP2

    Streaming Traffic Class AC Load Threshold For ARP 3 acLoadThreshold_streamingARP3

    AC UL Min C/I Ratio Estimation acUlMinCiRatioEst

    Downgrade Threshold Bitrate Margin pswBrMargin_pswDowngradeBrMarg

    Target Bitrate Margin pswBrMargin_pswTargetBrMarg

    Upgrade Threshold Bitrate Margin pswBrMargin_pswUpgradeBrMarg

    BTS Downlink Throughput Factor For CS1-CS4 throughputFactor_cs1cs4dlcs

    BTS Uplink Throughput Factor For CS1-CS4 throughputFactor_cs1cs4ulcs

    BTS Uplink Throughput Factor For MCS1-MCS4 throughputFactor_mcs1mcs4ulcs

    BTS Downlink Throughput Factor For MCS1-MCS9 throughputFactor_mcs1mcs9dlcsBTS Uplink Throughput Factor For MCS1-MCS9 throughputFactor_mcs1mcs9ulcs

    Transport Type transportType

  • 7/22/2019 2G Parameter Template Data and Voice Optimization

    41/85

    Definition Range & Step DB Nokia Default

    NWP Identification (c-number) of BSC. NOTE 0 ... 999999 -

    NWP With this parameter you identify the BC 1 ... 660 -

    NWP Identification (ID) of BTS object: either i 1 ... 660 -

    NWP With this parameter you define whether 0 ... 1 0

    SOP With this parameter you define the routi 0 ... 255 255

    NWP With this parameter you determine the 0 ... 100 0

    NWP With this parameter you determine the 1 ... 100 1

    NWP With this parameter you define whether 0 ... 1 0

    SOP With this parameter you can manually s 0 ... 65535 -

    NWP With this parameter you define the num 0 ... 15 8

    NWP With this parameter you calculate the m 0 ... 9 3

    NWP With this parameter you indicate the ma 0 ... 3 2

    NWP With this parameter you indicate the ma 0 ... 3 2

    NWP With this parameter you indicate the ma 0 ... 3 2

    NWP With this parameter you indicate the ma 0 ... 3 2

    NWP With this parameter you define the MS 0 ... 1 -

    NWP With this parameter you define the MS 0 ... 1 -

    NWP With this parameter you define the MS 0 ... 1 -

    NWP With this parameter you define the MS 0 ... 1 -NWP With this parameter you define the MS 0 ... 1 -

    NWP With this parameter you define the MS 0 ... 1 -

    NWP With this parameter you define the MS 0 ...