Four Steps toSafe Truss Installations

Presented by the Wood Truss Council of America

2

Most Truss Collapses Are Caused By….

Inadequate Temporary Bracing

3

4 Steps to Safe Truss Installations

1. Storage & Handling2. Temporary Bracing3. Construction Loading4. Fall Protection

4

Jobsite Package Truss Documentation ‘HIB’ Guides

Handling, Installing & Bracing

5

BCSI-B1 Summary Sheet Guide for Handling, Installing & Bracing

of Metal Plate Connected Wood Trusses

6

Step 1 – Metal Plate & Banding Warning

7

Step 1 - Jobsite Storage

Keep off the ground

8

Step 1 - Long Term Storage

9

Avoid Long Term Exposure

10

Step 1 - Storage Conditions

11

Step 1 - Handle with Care

12

Step 1 - Hoisting

13

Step 2 - Bracing Purpose of Bracing: To apply sufficient

support at right angles to the plane of the truss so as to hold every truss member in its design position.

14

15

Can’t Support Lateral Loads

16

Step 2 - Ground Bracing

17

Step 2 - Bracing Three Planes

Lateral Brace

Diagonal Brace

18

Step 2 – Top Chord Plane

ALWAYS Stabilize Lateral Braces with Diagonal Braces

19

Insufficient Top Chord Bracing

20

Spacer Pieces & No Diagonals!Can Lead to CompressionBuckling of the Top Chord

21

Top Chord Temporary

Bracing with

Spacers

22

Step 2 - Floor Truss Bracing

Lateral Brace Diagonal Brace

23

Bowing or Tilting?

24

Step 2 – SheathingSheathe early & often

25

No Bracing!

26

No Diagonals!

27

Results of Bad Bracing

28

Results of Bad Bracing

29

Results of Bad Bracing

30

Step 2 - Bottom Chord Bracing

Bottom Chord PlaneBottom Chord Plane

31

Step 2 - Bottom Chord Bracing

32

Step 2 - Bottom Chord Bracing

33

Step 2 - Web Plane Bracing

Web PlaneWeb Plane

34

Step 2 - Web Plane Bracing

35

Gable End Bracing

36

Step 2 – Permanent Web Bracing Locations

Compression Web BracingCompression Web Bracing

37

Step 2 - Web Buckling

38

Step 2 - Web Bracing

39

Step 2 - Web Reinforcement

T-Brace

L-Brace MetalReinforcement

Scab Brace

40

Step 3 - Construction Loads

41

B4 Loading DOs and DON’Ts

42

B4 Loading DOs and DON’Ts

43

B4 Loading DOs and DON’Ts

44

B4 Loading DOs and DON’Ts

45

B4 Loading DOs and DON’Ts

46

Loads with No Bracing!

47

Dangers of Overloading

48

Step 4 - Fall Protection

49

Step 4 - Fall Protection A falling worker attached to a single truss

may cause the trusses to “domino”

50

Step 4 – Pre-Assemble Units

Built it on the ground.

Sheath it for stability.

Pick it up and set in place.

51

Step 4 - Scaffolding Personal fall arrest system to OSHA

guidelines

52

Step 4 – Scaffolding?

53

Step 4 - Roof Peak Anchors Sheath and brace a portion of roof and

install a roof anchor to OSHA guidelines