KNX and Energy Efficiency

Gareth Rowlands

ABB LTD

© A

BB

Sto

tz-K

onta

kt G

mbH

2 A

pr 2

1, 2

023

KNX and Energy Efficiency

Input Output

100 %

Potential is not used sufficiently !

20 %

© A

BB

Sto

tz-K

onta

kt G

mbH

3 A

pr 2

1, 2

023

KNX and Energy Efficiency

… in Buildings

The Challenge:

Searching for the lost Energy

© A

BB

Sto

tz-K

onta

kt G

mbH

4 A

pr 2

1, 2

023

KNX and Energy Efficiency

What's going to drive the future?

Legislation

- Building Regulations (Low Energy Buildings Class)

- Climate Change Levy

- Availability of government sponsored grants (Tax relief)

Economic Pressure

- The simple costs of running a building

The Environment

- Social consciousness "Naming & Shaming"

- Carbon footprint

© A

BB

Sto

tz-K

onta

kt G

mbH

5 A

pr 2

1, 2

023

KNX and Energy Efficiency

Comfort ….

Security …

Economy ??

How ? How much ?

© A

BB

Sto

tz-K

onta

kt G

mbH

6 A

pr 2

1, 2

023

KNX and Energy Efficiency

Case Study: Lighting - the conventional Approach

All figures are real figures used for the investment calculation of a new office complex in the United Kingdom.

Energy Calculation

© A

BB

Sto

tz-K

onta

kt G

mbH

7 A

pr 2

1, 2

023

KNX and Energy Efficiency

Case Study: Lighting - the KNX Solution

Energy Calculation

© A

BB

Sto

tz-K

onta

kt G

mbH

8 A

pr 2

1, 2

023

KNX and Energy Efficiency

Assembly Hall + Office: Investment in KNX for

Lighting Control with Presence Detection

Connected Load: 91,5 KW

Price per KWH: 0,093 €

Reduction: 45 %

Investment: 106 T€

Saving per year: 8738 €

Return of Investment: 10 years

© A

BB

Sto

tz-K

onta

kt G

mbH

9 A

pr 2

1, 2

023

KNX and Energy Efficiency

University with Seminar Rooms: Comparision of two

Rooms (Energy for Light)

© A

BB

Sto

tz-K

onta

kt G

mbH

10

Apr

21,

202

3

KNX and Energy Efficiency

University with Seminar Rooms: Comparision of two

Rooms (Energy for Heating)

© A

BB

Sto

tz-K

onta

kt G

mbH

11

Apr

21,

202

3

KNX and Energy Efficiency

Efficiency Potential: Lighting

Automation Function Potential Savings

Influencing factors (Positive)

Constant Light Control(dimmed according to presence & brightness)

35 - 50 % - good natural lighting levels - required light levels > 300 lx- especially in combination with ST (below)

Automatic Lighting(switched according to presence & brightness)

25 - 45 % - good natural lighting levels- required light levels > 300 lx

Sunlight Automatic(blind & shutter positioning)

5 - 8 % - good natural lighting levels

Sun Tracing(Louvre angle positioning)

10 - 13 % - good natural lighting levels- especially in combination with CLC (above)

Staircase Lighting(Timed lighting)

? - areas of low usage

Source: Energieeffizienz automatisien, LonMark Deutschland e.V. Comparison to reference buildings according to DIN V 18599 or prEN 15232

© A

BB

Sto

tz-K

onta

kt G

mbH

12

Apr

21,

202

3

KNX and Energy Efficiency

Efficiency Potential: Heating and Cooling

Automation Function Potential Savings

Influencing factors (Positive)

Timed Operating Modes 5 - 10 % - continuous operation of heating - low thermal-mass construction

Presence 5 - 10 % - long absences

Window Monitoring 5 - 10 % - low thermal-mass construction

Free Night Cooling ? - fresh air circulation must be possible

Peak Load Optimisation ? - especially air conditioning

Automatic Shading(Temperature controlled shutter positioning blinds)

5% - high natural lighting levels- external shading

Timed Shading ? - daylight warming- night time warmth retention

Source: Energieeffizienz automatisien, LonMark Deutschland e.V. Comparison to reference buildings according to DIN V 18599 or prEN 15232

© A

BB

Sto

tz-K

onta

kt G

mbH

13

Apr

21,

202

3

KNX and Energy Efficiency

Customers ask ABB:

How can KNX help ? Potential for Savings ?

Current Situation: There are some information, sometimes with figures, rarely with fundamental background (… save up to 82 % … ?! …)

Real measurement (e.g. with comparision of buildings) is hardly available (University Bremen)

© A

BB

Sto

tz-K

onta

kt G

mbH

14

Apr

21,

202

3

KNX and Energy Efficiency

Conclusion: Common project KNX and Energy efficiency with the university Biberach

ABB Stotz-Kontakt Busch-Jaeger Hochschule Biberach

The university Biberach offers study courses in the field of building technology and is already working on the topic energy efficiency in buildings

© A

BB

Sto

tz-K

onta

kt G

mbH

15

Apr

21,

202

3

KNX and Energy Efficiency

Project description:

Investigation of a KNX-System with typical functions (Lighting, Shutter and blinds, HVAC) with defined conditions (Type of building, different user profiles) regarding possible savings

Consideration and calculation of the possible savings based upon DIN V 18599 and prEN 15232 in combination with existing softwaretools

Integration of products from ABB, including measurement of standby losses

© A

BB

Sto

tz-K

onta

kt G

mbH

16

Apr

21,

202

3

KNX and Energy Efficiency

Project progress: Start: November 2007 Finalized by the University Biberach until November 2008 Followed by a preparation of the data for publication (Summary and

Presentation)

© A

BB

Sto

tz-K

onta

kt G

mbH

17

Apr

21,

202

3

KNX and Energy Efficiency

Objection: Own consumption of the additional devices undo the possible savings Investigation of the university Biberach Typical own consumption of a KNX component: app. 200 mW

© A

BB

Sto

tz-K

onta

kt G

mbH

18

Apr

21,

202

3

KNX and Energy Efficiency

Room Temperature Control: conventional …

Thermostat Stage 5 - does not work for sure !

Problem:

Discipline of

the user

© A

BB

Sto

tz-K

onta

kt G

mbH

19

Apr

21,

202

3

KNX and Energy Efficiency

Room Temperature Control: conventional … Thermostat Stage 3 - may be it works ?

Problem:

Accuracy

© A

BB

Sto

tz-K

onta

kt G

mbH

20

Apr

21,

202

3

KNX and Energy Efficiency

Room Temperature Control: intelligent …

It works !

© A

BB

Sto

tz-K

onta

kt G

mbH

21

Apr

21,

202

3

KNX and Energy Efficiency

Room Temperature Control: intelligent…

Presence depending

Precise

© A

BB

Sto

tz-K

onta

kt G

mbH

22

Apr

21,

202

3

KNX and Energy Efficiency

Room Temperature Control: intelligent …

Time depending

© A

BB

Sto

tz-K

onta

kt G

mbH

23

Apr

21,

202

3

KNX and Energy Efficiency

Room Temperature Control: intelligent … Event driven

© A

BB

Sto

tz-K

onta

kt G

mbH

24

Apr

21,

202

3

KNX and Energy Efficiency

A typical example: Heating - conventional

Comfort 20ºC

not occ

upied

Aftern

oon less

on

Even

ing

class

es

Night 16ºC

mean room temperature ~ 19.5 ºC

Morni

ng le

sson

s

04:00 08:00 12:00 16:00 20:00

Comfort 21ºC

School Classroomnot o

ccupied

© A

BB

Sto

tz-K

onta

kt G

mbH

25

Apr

21,

202

3

KNX and Energy Efficiency

A typical example: Heating - according to demand

04:00 08:00 12:00 16:00 20:00

not o

ccup

ied

Aftern

oon

lesso

n

Even

ing

class

es

Night 16ºC mean room temperature ~ 17.5ºC

Mor

ning

less

ons

Comfort 21ºC

Standby 18ºC

They say: A temperature reduction of 1ºC can mean energy savings of 6%.

not o

ccup

ied

School Classroom

© A

BB

Sto

tz-K

onta

kt G

mbH

26

Apr

21,

202

3

KNX and Energy Efficiency

Lighting Control: conventional …

Illumination turned on, sun from outside, nobody in the room

© A

BB

Sto

tz-K

onta

kt G

mbH

27

Apr

21,

202

3

KNX and Energy Efficiency

Lighting Control:

intelligent …

Presence depending

Constant Light

Control

© A

BB

Sto

tz-K

onta

kt G

mbH

28

Apr

21,

202

3

KNX and Energy Efficiency

Blind control: conventional …Sun is shining, Blinds completely closed, Light on

© A

BB

Sto

tz-K

onta

kt G

mbH

29

Apr

21,

202

3

KNX and Energy Efficiency

Blind Control: intelligent …

Sun is shining, Noon, Lamellas horizontal

© A

BB

Sto

tz-K

onta

kt G

mbH

30

Apr

21,

202

3

KNX and Energy Efficiency

Blind Control: intelligent …

Sun shines , Afternoon, Lamellas slightly closed

© A

BB

Sto

tz-K

onta

kt G

mbH

31

Apr

21,

202

3

KNX and Energy Efficiency

Blind Control: intelligent …

Sun shines, evening, Lamella almost completely closed

© A

BB

Sto

tz-K

onta

kt G

mbH

32

Apr

21,

202

3

KNX and Energy Efficiency

Conjunction of a few Functions:

Winter: Sun shines, no Person present, Light on, Blinds up, Heating Standby Mode Winter: Sun shines, Person present, Licht on, Blinds in Position, Heating Comfort Mode Winter: Sun does not shine, Person present, Light controlled, Blinds up, Heating Comfort Mode Winter (Weekend): Sun does not shine, no Person present Light off, Blinds down, Heating in Frost Protection Mode

© A

BB

Sto

tz-K

onta

kt G

mbH

33

Apr

21,

202

3

KNX and Energy Efficiency

Conjunction of a few Functions:

Summer: Sun shines, no Person present, Light on, Blind down, AC Standby Mode Summer: Sun shines, Person present, Light on, Blinds in Position, AC Comfort Mode Summer: Sun does not shine, Person present, Light controlled, Blinds up, AC Comfort Mode Summer (Weekend): Sun does not shine, no Person present Light off, Blinds down, AC off

© A

BB

Sto

tz-K

onta

kt G

mbH

34

Apr

21,

202

3

KNX and Energy Efficiency

Conclusion:

An intelligent and energy saving solution e.g. in an office building should be as follows:

Presence Detection Constant Light Control Room Temperature Control Shutter control depending on sun position

All in one system

One consistent solution

© A

BB

Sto

tz-K

onta

kt G

mbH

35

Apr

21,

202

3

KNX and Energy Efficiency

Integration of Energy Meter

Visualisierung

© A

BB

Sto

tz-K

onta

kt G

mbH

36

Apr

21,

202

3

KNX and Energy Efficiency

Why measuring electrical Energy ?

Save Energy and Costs

Inspection of consumers behaviour Consumption becomes transparent Fair splitting of costs Internal billing Detection of “Energy Thieves” Creation of incentives for cost saving Change of consumers behaviour Approach for automation Load management Monitoring of the installation

+

"If you cannot measure it, you cannot

improve it."

Lord Kelvin

1824 -1907

$

© A

BB

Sto

tz-K

onta

kt G

mbH

37

Apr

21,

202

3

KNX and Energy Efficiency

Recommended