Vaisala HVAC product families80-series 90-series 110-series

Vaisala inhouse sensing technology x x x2-year warranty x x xDuct/outdoor models x xCalibration certificate x xSmart measurement modules xField adjustable x xConfigurable options x xSplashproof * xEnhanced chemical tolerance x x

* In certain models

3 B211486EN-C

Take a look at the full HVAC product portfolio here.

Page © Vaisala

80-seriesThe HMW80 humidity and GMW80 carbon dioxide transmitters are cost-efficient solutions for demand-controlled ventilation

Vaisala HUMICAP® and CARBOCAP® sensor technology provides long lifetime, long-term stability and minimal lifetime cost

CARBOCAP ® technology is suitable for 24/7 occupied spaces – internal reference measurement removes the need to adjust against unknown minimum values (ABC-calibration)

4 B211486EN-C

More information about the HMW80-series and the GMW80-series here.

Page © Vaisala

80-series Low self-heating by CARBOCAP ® sensor

The housing design allows for accurate CO2and temperature measurements in single device

Comprehensive family of cost-efficient variants available at short delivery times

Easy installation: – No warm-up time or calibration period

required– Loop powered versions available– Wiring in the back plate – snap-on

Sensor location

Sensor location

Vaisala GMW83DAnother brand

5 B211486EN-C

Page © Vaisala

The HMW90 humidity and GMW90 carbon dioxide transmitters are designed for the most demanding HVAC applications

Calibration certificate included

Highest accuracy

Digital ModBus RTU / BACNET MSTP outputs available

Field serviceable, low life cycle cost

90-series

6 B211486EN-C

Page © Vaisala

110-seriesHMDW110 series HVAC instruments are designed for demanding applications also in washdown areas

IP65 – duct, wall and outdoor mount

Calibrated HUMICAP® sensors provide ±2 %RH accuracy and long-term stability, traceable calibration certificate included

4 … 20 mA loop powered outputs

8 B211486EN-C

Page © Vaisala

110-series

Includes wall, duct and outdoor versions Outdoor version with a radiation shield

Compatible with the RDP100 remote display

Special sensors available for H2O2 disinfection application

Field serviceable

Easy installation

9 B211486EN-C

More information about the HMDW110-series here.

Page © Vaisala

HUMICAP® humidity sensor

The same sensor is used in demanding industrial applications in power generation, auto industry, industrial drying, paper mills etc. HUMICAP® sensor’s technical benefits:

Stability: Accurate measurements not only today, but after years of use Robustness: The sensor tolerates dust, dirt

and high humidity Selectivity: Fresh paint, cleaning fluids and

new building materials do not cause false readings or drift

10 B211486EN-C

More information about the humidity products.

Page © Vaisala

HUMICAP® humidity sensorUnbeatable stability both indoors and outdoors.

Humicap180R specified stability in typical HVAC applications:

± 0.5 %RH/year

11 B211486EN-C

Page © Vaisala

CARBOCAP® CO2 sensor The CARBOCAP® carbon dioxide sensor brings

analyzer-level reliability to HVAC measurements. The dual wavelength single-beam technology guarantees the best possible stability.

CARBOCAP® sensor’s technical benefits:– Immediately correct measurements when

plugged in, no waiting for the sensor to correct offset drift

– Works also in 24/7 occupied spaces as reference measurements are performed in every cycle

– Excellent stability and long lifetime with proprietary microglow lightsource

More information about the carbon dioxide products.

12 B211486EN-C

Page © Vaisala

CARBOCAP® CO2 sensor

The light output from the microglow chip is much more stable over time than traditional filament lamps. This means improved CO2 measurement stability and longer sensor lifetime

Emitter

Membrane for thermal insulation

Frame

Reference and CO2 measurement is performed on every measurement cycle using an inhouse tunable filter chip. This guarantees excellent stability and low temperature dependence. 1000 ppm stability test results for 23 powered units in office conditions shown in picture with ±75 ppm 5 year total accuracy specification

Filament lamp

Largest value

smallest value25% fractileMedian75% fractileLegend:

13 B211486EN-C

Page © Vaisala

Animation of the CARBOCAP ®

operating principle

www.vaisala.com/CARBOCAP

B211486EN-C14

Page © Vaisala

80-series variants

GMW84 GMW84S GMW83 GMW83A GMW83RP GMW83T GMW83D GMW83DRP GMW86P GMW86PTCO2 measuremet x x x x x x x x x xT measurement x x x x 2) x x 2) 1) 1)Humidity measurement x x4..20 mA x x x x0..10 V x x x x x x x xTraffic lights xRelay xTemperature setpoint x xDisplay

TMW82 TMW83 HMW82 HMW83 HMW88 HMW88D HMW89 HMW89DRH measurement x x x x x xHumidity parameters x x x xT measurement x x x x x x x x4..20 mA x x x x0..10 V x x x xWall mount x x x x x x x x

TMD82 TMD83 HMD82 HMD82D HMD83 HMD83D HMS82 HMS83RH measurement x x x x x xHumidity parameters x x x x x xT measurement x x x x x x x x4..20 mA x x x0..10 V x x x x xDuct mount x x x x x xOutdoor mount x x

16 B211486EN-C

1) Passive Pt10002) Passive Pt1000 and

active voltage output

Page © Vaisala

90-series variants

TMW92 TMW93 HMW92 HMW92D HMW93 HMW93D HMW95 HMW95DRH measurement x x x x x xT measurement x x x x x x x xCalculated parameters x x x x x x4..20 mA x x x0..5/10 V x x xBacnet MS/TP x xModBus RTU x xDisplay x x xRelay x x

GMW93 GMW93D GMW93R GMW93RD GMW93RA GMW94 GMW94D GMW94RD GMW95 GMW95D GMW95R GMW95RDCO2 measurement x x x x x x x x x x x xRH measurement x x x x x xT measurement x x x x x x x x x x x xCalculated parameters x x x x x x4..20 mA x x x0..5/10 V x x x x xBacnet MS/TP x x x xModBus RTU x x x xDisplay x x x x x xIndicator LED x

Configurable models TMW90, HMW90, GMW90 and GMW90R

17 B211486EN-C

Page © Vaisala

110-series variants

HMW110 HMD110 HMS110 HMW112 HMD112 HMS112RH x x x x x xT x x x x x xCalculated parameters x x x x x xWall mount x xDuct mount x xOutdoor mount x xCatalytic sensor * *Configurable outputs x x x

*) Catalytic sensor for environments with hydrogen peroxide desinfection

18 B211486EN-C