cÜxáxÇàá 100% Reliable Power Sharing System another technology leap from Series TM AUTOMATIC SOURCE CHANGEOVER j|à{ CURRENT LIMITER [ACCL]

StartOff ACCL [Automatic Source Changeover cum Current Limiter

Embed Size (px)

Citation preview

cÜxáxÇàá 100%  

R e l i a b l e P o w e r S h a r i n g S y s t e m

another technology leap from

Series TM 

AUTOMATIC SOURCE CHANGEOVER

j|à{ CURRENT LIMITER [ACCL]

AUTOMATIC SOURCE CHANGEOVER j|à{ CURRENT LIMITER [Digital] Series

TM 

Features Micro-Controller based design Automatic Source Change Over Break before make change-over system Neutral isolation for all models Current Limiting function Counter for number of interruptions, thereby protecting your valuable equipment Prevents over loading of the Generator LED / Digital indication of Status Saving in wiring and wall space Energy Saving... Reduction of CO2 Emission

Functions When the Mains Supply is available

The load is connected to the Mains supply (after initial delay) and the consumer can draw the full load as per the Sanctioned rating. When the Mains Supply fails and Standby Generator Supply is available

The consumers are connected to the generator in a sequence depending upon the pre-set ‘Initial Delay’* timing, in order to limit the sudden load on the Generator. The Unit Monitors the Current at factory “Set Limit”. * If the Current exceeds the limit, the load is disconnected 5 times in 1 second intervals as a warning and then, automatically reconnects it after 5 minutes *. This cycle of interruptions and warning repeats 2 times and unless the load is reduced to the set limit the power supply will permanently disconnected. The supply will be re connected only by an operator manually or when the Main / Dg supply restarts. During this period, the Consumer is expected to switch off the non-essential loads and reduce it to within the limit. When the load is within the ‘Set Limit’, the Generator continues to supply the load. The supply from the Generator to the load can be restored after the Generator connection is reset by switching OFF/ON the Gen MCB. Or by pushing the reset button on the StartOff unit.

When the Mains supply is restored The Load is automatically transferred to the Mains supply after pre-set time.

LED Indicators: Over Voltage, Under Voltage, Over Load, Mains On, Generator On Digital display: 2 line /4 line digital display : All the above status.

* These Parameters can be Pre-Programmed depending upon requirements of Customers and also can be Re-programmed at any time.

Automatic Load Changeover Relay is a high precession system for efficient distribution of generator power in multi-storied apartments, commercial complexes etc. StartOff ACCL Series are designed to connect mains supply to load till mains is present. On mains failure and receiving generator power, it connects the load to DG supply. During DG operation, load drawn is monitored. If the load exceeds the allotted limit, it disrupts the supply and rechecks in intervals. On reducing the load and keeping it within the limit, load is connected to DG supply. For different applications, we have specific models. They are with load limiter, without load limiter, transfer of load from one phase to other phase and many additional functions.

Special Features Over Voltage (OV) / Under Voltage (UV) protection by intelligent sensing technology.

This feature provide maximum protection to consumer’s electrical equipment caused by voltage fluctuations or Over Voltage or Under Voltage problems from EB and DG sides. In both events, the StartOff ACCL automatically turn itself off and protect the entire power supply system. Under Voltage protection system save the Generator from possible damages. StartOff ACCL can with-stand high voltage fluctuations up to 300v without any damage to the unit and thereby its life is very long compared to any other brands. Because of the high quality of components and the quality controlled workmanship, StartOff ACCL unit is almost maintenance free.

The Ultimate Solution for your power distribution needs…

Maintenance Service within 24 hours! StartOff Products are engineered to provide you uninterrupted hassle free performance. The product is almost maintenance free for years. Even though, StartOff service team is equipped to provide faster service within 24 hours in case of any trouble.

Series

TM 

SPECIFICATIONS Technology  Microprocessor Based Frequency  50 Hz EB  Load Current  16 A, 32 A, 40 A , 63 A, 80 A, 100 A, 125 A   * DG Load Current  16 A, 32 A, 40 A 63 A, 80 A, 100 A, 125 A   * DG Max Current Range [Limiter]   (Factory Set) 0.1 A to 30A   *  

Models  

1 Phase EB & 1 Phase DG   3 Phase EB & 3 Phase DG 3 Phase EB & 1 Phase DG 

Product Warranty  18 Months   ** Enclosure  Powder Coated Cabinet Display  LED / Digital 

* **  

Specifications can be changed upon customer requirements. 12 months Replacement + 6 Months Service. 

Product Specifications

…A leap ahead

Model Range

MODEL   SPECIFICATIONS  PHASE  [EB]  PHASE [DG]  MOUNTING 

SOP16LX  EB16A/DG LIMITER 200W‐1500W   SINGLE/THREE  SINGLE  PANEL 

SOP1616  EB16A/DG 16A  NON LIMITER  SINGLE/THREE  SINGLE/THREE  PANEL 

SOD16LX  EB16A/DG LIMITER 200W‐1500W   SINGLE/THREE  SINGLE  DB 

SOP30LX  EB30A/DG LIMITER 200W‐5000W   SINGLE/THREE  SINGLE  PANEL 

SOP3030  EB30A/DG 30A  NON LIMITER  SINGLE/THREE  SINGLE/THREE  PANEL 

SOD30LX  EB30A/DG LIMITER 200W‐5000W   SINGLE/THREE  SINGLE  DB 

SOP40LX  EB40A/DG LIMITER 200W‐5000W   THREE  SINGLE  PANEL 

SOP4040  EB40A/DG NON LIMITER   THREE  THREE  PANEL 

SOD40LX  EB40A/DG LIMITER 200W‐5000W   THREE  SINGLE  DB 

SOP60LX  EB60A/DG LIMITER 200W‐5000W   THREE  SINGLE  PANEL 

SOP6060  EB60A/DG NON LIMITER   THREE  THREE  PANEL 

SOP80LX  EB80A/DG LIMITER 200W‐5000W   THREE  SINGLE  PANEL 

SOP8080  EB80A/DG NON LIMITER   THREE  THREE  PANEL 

SOP100LX  EB100A/DG LIMITER 200W‐5000W   THREE  SINGLE  PANEL 

SOP100100  EB100A/DG NON LIMITER   THREE  THREE  PANEL 

SOP125LX  EB125A/DG LIMITER 200W‐5000W   THREE  SINGLE  PANEL 

SOP125125  EB125A/DG NON LIMITER   THREE  THREE  PANEL 

Panther Techno Labs Karassery [P.O], Mukkam, Pin: 673602 Calicut, Kerala, India. Tel: +91 9447950498, +91 9744212586 Email: [email protected]

™ Division 

For enquiries: 

All Specifications and settings can be customized as per the requirement of specific needs