Spacial, Thalassa, ClimaSys

Universal enclosures briefing

Property of Schneider Electric

Simply reliable. Simply available.

December 2017

• Introduction to the Enclosure offer

• How to select an enclosure

Technical needs

Components and Accessories

Thermal

• Range overview

• How to understand our references

• Where to find further details

• Quiz

Table of content

Property of Schneider Electric | Page 2

Enclosure's role

Page 3Property of Schneider Electric |

Enclosure system = electrical devices

conditioning solution

Devices: Installation and cabling,

thermal dissipation

People: Operator control and

maintenance, ergonomic and protection,

and access

Ambiance: Dust, water, temperature

changes, sunlight, chemical agents, radio

waves, vibrations, cleaning agents,

vandalism, etc.

&

>< ><>

>

&& & && & && & &

&&&

Enclosure’s role

Page 4Property of Schneider Electric |

• Class II: Total

insulation

product

• No sharp edges

• Surface

temperature

• No penetration

of object when

IP > 4X

&• Vandalism

• Shock

• Flame

• Forced entry

• Theft

• Humidity and

condensation

• Thermal stress

• Overheating

• Corrosion

• Chemicals

• High

temperature

• UV rays

• Air pollution

• Snow

• Dust

• Support for

HMI functions

• Time saving on

installation

• Perfect fit of

enclosure +

device + thermal

conditioning

People

protection

Device

protection

Thermal

management

Harsh

environment

Human-machine

interface (HMI)

Best-in-class

installation

system

Enclosures are everywhere

Page 5Property of Schneider Electric |

How to select the right enclosure and its accessories

Page 6Property of Schneider Electric |

In just 4 steps ... Think on ...

• Indoor

- Spacial — Steel for

standard

- Spacial — Stainless

steel

for harsh environment

• Outdoor

- Thalassa — Polyester

for standard

- Spacial and Thalassa

— Heavy duty for

harsh environment

1• Tightness (IP)

• Impact resistance (IK)

• Size constraints

(HxWxD)

• Color

• Mounting architecture

(floor, wall, post) and its

accessories (Plinth, etc.)

2• Door system

- Transparent/blind

- Lock, earthing,

raceways

• Cable entry system and

position

• Mounting accessories

- Mounting plate (plane,

Telequick system,

modular, 19” )

- Cabling accessories

3Thermal calculation with

ProClima software and

Climasys offer selection

• Ventilation

• Cooling

• Heating

• Thermal measurement

and control

4Environment

Technical

needs

Components and

accessoriesThermal

Technical needs

Page 7Property of Schneider Electric |

• According

to IEC 60529

• Certification

according

to UL 50E

• NEMA type

according

to NEMA 250

standard

• Resistance

to external

mechanical

impact

IEC 62262

• Up to IK 10

• Dimensions

of the

enclosure:

Height (H) x

Width (W) x

Depth (D)

• Take into

account the

possibilities

for modular

enclosure

associations

Enclosures and

accessories to fit

centralized or

distributed

machine

architecture

• Boxes

• Wall mounting

• Floor standing

• Post

• HMI

• Post fixing

devices

• Specific specs

• Seismic

• Vibration

• Corrosion

resistance

• EMC

• Steel RAL 7035

• Polyester RAL

7032

Accessories

• Canopy

• Plant

• Eyebolts

• Fixing lugs

• Reinforcement

for heavy

devices

IP IK

2Tightness Impact resistance Size Architecture ColorAccessories and specific specs

Components and accessories

Page 8Property of Schneider Electric |

3

• To see inside: Glazed door, acrylic windows,

control protection frames

• Lock: Inserts, keys, padlocks

• For maintenance: Door stops, switches

• Raceways door mounted:

Cable-duct, door cross-rails,

cable ties

• HMI device installation accessories

• Cable entry number and type selection

• Cable glands or membranes: Tightness and

cable supports

• Earth connection: Electrical continuity by

earthing braids or leads

• Device mounting accessories

• Power distribution

• Equipment mounting plates

- Plain for DIN devices

- Telequick System for nonDIN device

(micro-perforated or perforated)

- Modular

- 19” device installation system

• Cable accessories

- Cable ducts

- Cross rails

- Cable supports

• HMI device accessories

+Door Body or frame Mounting accessories

Optimization

• Our experience: Customers either oversize

or undersize thermal solutions

• The same machine that is exported in

different geographical zones normally

needs and specs

are different solutions (even indoors)

(e.g., RU -15 … +30 ºC , UAE +20 … +55

ºC)

What

Reliability

• One of the most sensitive aspects for

getting the machine reliable; control panel

conditioning ensures device lifetime and

reliability

Thermal

Page 9Property of Schneider Electric |

4

The only way or action to validate the correct thermal installation is to use thermal calculation software

Installation for outdoors

• Private or public installation

• Geographical location of the installation to set

thermal working conditions using the global

ProClima built-in weather database

- Sun radiation value (W/m2)

- Temperature and humidity data

Installation for indoor and outdoor

• Mounting position of the enclosure (on wall, etc.)

• Enclosure material and RAL color

• Dimensions of the machine control panel

• Watts dissipated by the installed devices

(if customer doesn't know, ProClima will help)

Thermal

Page 10Property of Schneider Electric |

4

Knowing all these variables in advance, ProClima software suggests thermal solutions for your customer.

How

Thermal calculation with minimum customer data to start

General overview of enclosures

Page 11Property of Schneider Electric |

Outdoor

Spacial steel

Indoor

Spacial stainless steel Thalassapolyester

Thalassa PHD heavy duty polyester

Spacial SFHD/S3DHD

heavy duty steel

Standard environment Harsh environment Standard environment Harsh environment

Material

architecture

accessories +All offers are ready

for thermal conditioning

solutions

General overview of enclosures

Page 12Property of Schneider Electric |

Indoor standard environment Indoor harsh environment Outdoor harsh environment

Spacial steel Spacial stainless steel

Spacial in steel: Boxes, wall mounting,

monobloc, and suitable floor standing

Key benefits

• Protection of electric and electronic devices

against dust, splashing with oil, and impacts

• Safe access of people to devices

Performance

• Universal range for industry

• E.M.C. range against

electromagnetic disturbances

(treated with Aluzing)

• ATEX version available

Spacial in stainless steel: Wall mounting, monobloc,

and suitable floor standing

Key benefits (additional to steel)

• Suitable to demands from F&B, Life Sciences,

and infrastructure industries

• Hygiene and corrosion-resistant properties

Performance

• 304 L stainless steel resistant to corrosion

and suitable for cleaning and disinfection

• 316 L stainless steel (“marine stainless

steel”) high resistance to corrosion

• ATEX version available

General overview of enclosures

Page 13Property of Schneider Electric |

Outdoor Standard Environment

Thalassa polyesterhalassa polyester

Thalassa in polyester or plastic (ABS, polycarbonate):

Boxes, wall mounting, and floor standing

Key benefits

• Outdoor infrastructures and electrical installations protection to sunlight, rain,

saline mist, extreme temperatures, oil splashes, and chemical and corrosive agents

• Safe protection for those in contact with public

• Insulated (to be Class II according to IEC 61439-1:2011)

Performance

• Universal range for industry and infrastructure

• ATEX version available

• Lightweight

• Fire resistant

General overview of enclosures

Page 14Property of Schneider Electric |

Outdoor Standard Environment

Spacial SFHD/S3DHD heavy duty steel

Spacial heavy duty made from carbon steel

protected against corrosion (certified C4H ISO 12944)

• IP55 floor standing

Thalassa PHD heavy duty polyester

Thalassa heavy duty polyester reinforced

with a double layer of fiberglass that is ultra-resistant to

vandalism

• Enclosure includes heavy duty canopy and Plinth, locking

system with 1242E key and padlock, aluminum cable

gland plate

• Anti-posting door

Key benefits (additional to steel

and polyester)

• For severe outdoor environments

• Tested, certified for outdoor compliance

standards

• Active/passive thermal management

engineering right in

• Resistant to chemicals

Performance

• Dedicated accessories pre-installed for

outdoor conditions

• -45 °C up to +80 °C resistance

• Pressure and shock resistant IEC

61439-5:2010

• IP66 wall mounting

ClimaSys: Thermal management overview

Page 15Property of Schneider Electric |

Thermal management software

Enclosures

offer

Passive thermal solutions

Mechatronic

devices

Small thermal offer Big thermal offer

Airing Ventilation

from 38 to 850 m3/h

Control Heaters

from 10 W to 550 W

Cooling units

from 0.3 kW

to 15 kW

Exchangers

air water

from 1 kW to 15 kW

Exchangers air

from 22 W/K to 80 W/K

Thermal management should guarantee suitable control of the temperature and humidity conditions inside the

enclosure to guarantee optimal operation of the components installed in the inside.

What is thermal management?

Page 16Property of Schneider Electric |

Thermal

management

software

Airing

Property of Schneider Electric | Page 17

• Using natural convection

- Useful in technical rooms

- Clean and filtered ambients

- Only for low dissipate powers

- And good external

temperatures

Filterless grill

Filter can be removed

for filtered ambients

Internal convection

Property of Schneider Electric | Page 18

• Generating intense and continuous

turbulences inside the enclosure.

We homogenize and reduce

internal temperature.

- Useful in outdoors and technical rooms

- High water-tightness

- Only for low dissipate powers

- And good external temperatures

Ti1 > Ti2

Ti1 Ti2

Forced ventilation

Property of Schneider Electric | Page 19

• Renews the air inside the enclosure

with cold air from the outside using the

necessary flow to achieve a suitable

DT (Te -Ti ≤ 5 ºC)

• Maintains the IP required in each case

- Useful in technical rooms and outdoors

- Up to IP55

- Depends on dT (Te -Ti ≤ 5 ºC)

- Control equipment is required

Ti

ClimaSys forced ventilation

Ti1 > Ti2

Te

Cooling: Cooling units

Property of Schneider Electric | Page 20

• Cool and dehumidify

• Watertightness is mandatory

• ΔTneeded = inexistent

• IPmax = IP55

ClimaSys cooling units

TiTe Ti

Te

Humidity and low temperatures: Heating

Property of Schneider Electric | Page 21

• Avoid condensation, high

humidity, and low temperatures

• IPmax = IP66

Initial

conditions

Ti = 10 ºC

RH = 63 %

Ti = 20 ºC

RH = 33 %

Ti = 35 ºC

RH = 14 %

Heating units

+

Control

Ti = 5 ºC

RH = 90 %

Function control

Property of Schneider Electric | Page 22

• TH thermostats, HY hygrostats,

and HYT hygrotherm

• Regulates and optimizes the

working temperature conditions

inside the enclosure

• Prolongs the lifetime of thermal

components installed

ClimaSys thermal control

L

N

+L

N

+

L

N

+

Understand our references

Page 23Property of Schneider Electric |

Thalassa insulating enclosures Spacial metal enclosures ClimaSys

Universal enclosures code

Product family

See the new names above

Specifications

Dimensions, power,type of function

Composition

Type of door, material, additional accessories

N S Y S F T1 8 8 5 0Spacial SF/steel floor-standing suitable – 1800x800x50

N S Y T B T2 4 1 9 8Thalassa TBS/industrial boxes in ABS – 241x194x87S

• Thalassa TBP

Industrial boxes PC

(UL)

• Thalassa TBS

Industrial boxes in

ABS

• Thalassa PLS

Insulating modular

boxes

• Thalassa PLM

Wall-mounting

in polyester

• Thalassa PLA

Floor-standing

in polyester

• Thalassa PLD

Floor-standing DIN in

polyester

• Spacial S44 – S57 – SDB

Steel industrial boxes

• Spacial S3D

Steel wall-mounting

• Spacial SF

Steel floor-standing suitable

• Spacial SM

Steel floor-standing compact

• Spacial SD

Steel control desk

• Spacial S3X

Stainless-steel wall-mounting

• Spacial SMX

Stainless-steel floor-standing

monoblock

• Spacial SFX

Stainless-steel floor-standing

suitable

• Spacial SDX

Stainless-steel control desk

• ClimaSys CV

Ventilation system

• ClimaSys CA

Natural airing

• ClimaSys CU

Cooling units

• ClimaSys CE

Exchangers

• ClimaSys CR

Resistance heaters

• ClimaSys CC

Thermal controlc

Universal enclosures digital tools gateway

Page 24Property of Schneider Electric |

2D/3D filesOn traceparts.net

and by packages

Eplan macros2-D and 3-D format

Catalog General catalog

and technical guides

Digital rulesSelection software suite

for enclosures and

accessories

ProClimaThermal calculation

software for control panel

Spacial.proDimension sizer software

for control panel

Spacial.confQuotation software for

customized enclosures

Spacial, Thalassa,

ClimaSys

Check for latest version online

If links not active, please download

• IEC 62208: Standard for empty enclosures

‒ Standard used for enclosures prior to the installation

of equipment, including:

– IEC 60529: Degrees of protection provided by enclosure (IP)

– IEC 62262: Degrees of protection provided by enclosure (IK)

• IEC 61439: Low voltage switchgear and control

gear assemblies

• UL508A: Industrial control panels

• Dedicated: Seismic, marine, nuclear, EMC, outdoor, etc.

Main international standards

Property of Schneider Electric | Page 25

• Click here to find info on SE.com

• Click here to find Enclosures on

SE.com

• Click here to access our Digicat

• Click here to access to CAD files

• Click on the link below for FAQs

(frequently asked question)

Where to find details

Property of Schneider Electric | Page 26

Property of Schneider Electric |

Quiz

Based on what

you’ve learned so

far, try to answer to

this quiz

?

Page 27

Q1

Give three enclosure’s role

Q2

What are the two main ranges of enclosures?

Q3

What is Climasys range?

Q4

What is the software used for Climasys range?

Q5

Is there ATEX version available in Enclosure range?

Property of Schneider Electric |

Quiz answers

Q1

Give three enclosure’s role

People protection, Thermal management, Protect for Harsh environment

Q2

What are the two main ranges of enclosures?

Thalassa range (steel) and Spacial range (polyester)

Q3

What is Climasys range?

It’s Thermal management offer

Q4

What is the software used for Climasys range?

ProClima for thermal calculation and EffiClima for thermal tracking

Q5

Is there ATEX version available in Enclosure range?

Yes, ATEX version is available

Answers

Page 28

Property of Schneider Electric |

Thank you

Page 29