21
Welcome to Salix, Croxton Park

Salix Cleanleach Reciplical

Embed Size (px)

Citation preview

Page 1: Salix Cleanleach Reciplical

Welcome to Salix, Croxton Park

Page 2: Salix Cleanleach Reciplical

- No Fire Alarm Expected

- Refreshments

- Toilets

House Keeping

Page 3: Salix Cleanleach Reciplical

Offices

Construction Teams

Croxton Park

Page 4: Salix Cleanleach Reciplical

• 20 Acre (5 hectare) nursery

• UK Native wetland & wildflower plant producer

• Flora locale approved supplier.

• Cell/Pot Plant Production

• Coir rolls and pallets

Croxton Production

Page 5: Salix Cleanleach Reciplical

Location of Cleanleach

Page 6: Salix Cleanleach Reciplical

UK Cleanleach Reciplical: Full Water Harvesting, Irrigation and Recycling

• Rainwater Collected from Polytunnels

• Stored in Tanks • Used to irrigate pot grown

plants• Cleaned in Cleanleach

System• Recycled back into tanks• Main Differences: Drainage

Layer under Sand filter & Floating Reedbed

Page 7: Salix Cleanleach Reciplical

1m

24m

CleanLeach: DETAIL 4: General Arrangement: NTS

GravelFilter

Outlet Pipe (Centre)

Sand Filter

5% fallin last 3m of bed

SSF Gravel Reedbed

Floating Reedbed

Chamber (By Others): Control Flow to either bed (split flow)

35m (1% Fall)

Page 8: Salix Cleanleach Reciplical

CleanLeach: Detail 3: Close up Sand Filter Outlet & Geotextile Layers: NTS

Gravel Filter (Wrapped in Terram 1000)

Outlet Pipe (Set 50mm below bottom and sealed around pipe)

Mypex on surface

Sand Filter

Pond Liner to Seal Entire Bed (as per existing pond lined beds).

Drainage Geotextile

Page 9: Salix Cleanleach Reciplical

Drainage Geo-composite

Page 10: Salix Cleanleach Reciplical

CleanLeach: Detail 6: Section Of Gravel SSF Reedbed: NTS

Gravel Filter (Wrapped in Terram 1000: 1m wide)

Outlet Pipe (Set 50mm above gravel and sealed around pipe: Need to be able to adjust flow to back up water depth)

Gravel

Pond Liner to Seal Entire Bed (as per existing pond lined beds).

Inlet Pipe (Set 70mm above gravel and sealed around pipe)

1% Fall

0.5m

100mm Freeboard

Page 11: Salix Cleanleach Reciplical

CleanLeach: Detail 7: Section of Floating Reedbed: NTS

Outlet Pipe (sealed around pipe: Need to be able to adjust flow to back up water depth)

Floating Reedbed

Pond Liner to Seal Entire Bed (as per existing pond lined beds).

Inlet Pipe (sealed around pipe)

1% Fall

0.45m

200mm Freeboard

Open Water

Page 12: Salix Cleanleach Reciplical

Construction

Page 13: Salix Cleanleach Reciplical

Construction: Mid June to End August

• Good weather during construction

• Driest September Recorded

• Very Wet October

Page 14: Salix Cleanleach Reciplical

Installation of Geo- Composite Drain

Page 15: Salix Cleanleach Reciplical

Xlyit Fibres Added to Improve Soil Structure & Soil Drainage (Fine Sand Compacts When Disturbed)

Page 16: Salix Cleanleach Reciplical

Completed Layers

Page 17: Salix Cleanleach Reciplical

Flow Distribution

Page 18: Salix Cleanleach Reciplical

SSF Gravel & Floating Reedbeds

Page 19: Salix Cleanleach Reciplical

SSF Gravel & Floating Reedbeds

Page 20: Salix Cleanleach Reciplical

Plant Species Grown in Coir Mats

• Phragmites australis

• Carex acutiformis

• Iris pseudacorus

• Lythrum salicaria

Page 21: Salix Cleanleach Reciplical

State of the Art: EWWTA, CWA, ESWEG

• Phosphate Capture • “Passive Water

Treatment” • Whole Life costs• Sustainability; Waste &

Energy Costs • Maintenance &

Refurbishment Costs • Water Framework

Directive “Driver”