DESCRIPTION
We are happy to announce that a new Scan&Paint version 2.0 is released! Scan&Paint 2.0 has many additional functions. With grid calculation method the results become more stable. The ability of connecting 2 reference sensors gives an opportunity to use Scan&Paint 2.0 for Transfer Path Analysis measurements and Operational Defection Shapes measurements. Reactivity error function displays the estimation of the uncertainty that reactivity index and the phase mismatch of Microflown and pressure sensor introduce in the intensity measurement. Graphic display has new options, such as power spectrogram analysis, harmonic cursor, double cursor analysis and much more. The release-note will widely explain new features of this Scan&Paint version. If you have any questions, don't hesitate to contact us.
Citation preview
Software Release Note
PO Box 2205 | 6802 CE Arnhem | The Netherlands [email protected] | www.microflown.com | Telephone: +31 88 001 0800
New Features and Updates
Scan & Paint 2.0
Hardware | Sensor Integration
Support of reference sensors Two reference sensors can be added to obtain the relative phase information
• Microphones (IEPE / CCP / ICP )• Accelerometers (IEPE / CCP / ICP )
Software Release Note | Scan & Paint 2.0 2
Video and Audio playback optionAllowing a quick preview of a complete measurement and the speed of reproduction can be changed. Also enables to equalize audio snap to point (the frequency band filtering).
3Software Release Note | Scan & Paint 2.0
Tracked position exclusion tool
4
Two new options: - polygon selection (now different measurement points can be chosen and deleted with one CLICK) - scanning speed (the measurement point can be selected by the time expend in each position and deleted the ones that are under the threshold).
Software Release Note | Scan & Paint 2.0
Auto-offset function
5
The offset between the tracking color and the actual sensor position can now be set automatically by selecting two points in the map.
Software Release Note | Scan & Paint 2.0
Control over graphical display
6
Improvements are the possibilities to adapt the buttons and sliders to PC screen resolution and to choose the keyboard button to start/stop measurement.
Software Release Note | Scan & Paint 2.0
Problem reporting
7
• Log file:oAutomatic error/problem report generated by the
system• Direct mail contact with Microflown Customer services
Software Release Note | Scan & Paint 2.0
Reactivity error display
8
Displays the estimation of the uncertainty that reactivity index and the phase mismatch of Microflown and pressure sensor introduce in the sound intensity measurement.
Software Release Note | Scan & Paint 2.0
Multi-view display
9
This option enables comparison of various projects or measurement files at the same time (same analysis and the same scaling)
Software Release Note | Scan & Paint 2.0
Graphic displays | New options
10
• Copy/ paste• Compare• Sum and average
different plots
Figure 1. Copy and paste graphs
Software Release Note | Scan & Paint 2.0
Graphic displays | New options
11
Power spectrogram analysis has been improved by adding X and Y selections, being able to select and analyze a certain time or frequency band.
X - selection Y - selection
Software Release Note | Scan & Paint 2.0
Graphic displays | New options
Software Release Note | Scan & Paint 2.0 12
• Double cursor analysis
• Harmonic cursor
Graphic displays | New options
Software Release Note | Scan & Paint 2.0 13
• Export to .wave file
• Complete flexibility in markers selection
Grid calculation method
Software Release Note | Scan & Paint 2.0 14
Gives the opportunity to create smaller sub areas where measurement data are averaged. The result becomes more stable and more suitable to process the multiple scans. Grid method improves the accuracy of the results by adjusting the spatial resolution.
Absorption mapping
Software Release Note | Scan & Paint 2.0 15
Better integration of absorption measurements in Scan & Paint. Calibration measurements can be directly loaded.
New mapping and plotting options
Software Release Note | Scan & Paint 2.0 16
In recording stage there are new possibilities to real time plot the following new parameters:- coherence between channels- transfer function between reference and main channels.
New mapping and plotting options
Software Release Note | Scan & Paint 2.0 17
In the processing stage the following plotting options are now available: transfer function and coherence between PU channels and activated reference channel(s).
New mapping and plotting options
Software Release Note | Scan & Paint 2.0 18
In the analyzing stage following new parameters can be mapped: - coherence between channels - transfer function between channels - reactivity index error estimation
Reporting tab
Software Release Note | Scan & Paint 2.0 19
• Image resizing and reallocation
• New pages generation
• New exporting functionalities to .pdf and image file