Pfisterer Connex High Voltage Motor Connectors 6.6kV - 13.8kV - CMS CONNEX Motor Star Point Connector

Embed Size (px)

Citation preview

Page 1: Pfisterer Connex High Voltage Motor Connectors 6.6kV - 13.8kV - CMS CONNEX Motor Star Point Connector

62 ZZZ�S¿VWHUHU�FRP

&211(;�0RWRU�&RQQHFWRU��&0$����&211(;�6WDU�3RLQW�&RQQHFWRU��&06���6L]H��6SHFLDO�IHDWXUHVŶ metal-enclosedŶ fully-insulatedŶ touchproofŶ�high short-circuit protectionŶ suitable for outdoor useŶ separable into two partsŶ degree of protection IP 66Ŷ up to 11 kV Ex

Jack Nottidge
Page 2: Pfisterer Connex High Voltage Motor Connectors 6.6kV - 13.8kV - CMS CONNEX Motor Star Point Connector

63ZZZ�S¿VWHUHU�FRP

&211(;�0RWRU�&RQQHFWRU��&0$����&211(;�6WDU�3RLQW�&RQQHFWRU��&06���6L]H�� i

09�&211(;

�&0$��DQG

�&06�6\

VWHP

09�&211(;�&0$��DQG�&06�6\VWHP

Jack Nottidge
Page 3: Pfisterer Connex High Voltage Motor Connectors 6.6kV - 13.8kV - CMS CONNEX Motor Star Point Connector

64 ZZZ�S¿VWHUHU�FRP

&0$�&211(;�0RWRU�&RQQHFWRU��6L]H��The CMA CONNEX Motor Connector permits the simple and quick connection of high-voltage motors, providing at the same time a completely metal clad and touchproof connector area.The system is easily connected instead of the motor terminal box. It permits quick start-up and quick motor change in operation.

$WWHQWLRQ�CONNEX separable connectors size 1 for single and three core cables up to 10 kV/240 mm2 respectively 20 kV/185 mm2 must be ordered separately.

1R� 1RPLQDO�YROWDJH :HLJKWUR���8��N9� �NJ�

����������� 13.8 - 33.5

����������� 11 Ex 32.6

&06�&211(;�0RWRU�6WDU�3RLQW�&RQQHFWRU��6L]H��The CMS CONNEX Star Point Connector allows a simple and quick metal-enclosed and touchproof star point connection. Thereby, the on-site change from the connecting side to the star-point side of the motor can occur easily. Interchangeability of cable connection and star point connector on the HV motor.

,PSRUWDQW��Basic CMA equipment must be ordered separately for this „neutral bridge“!

1R� 1RPLQDO�YROWDJH :HLJKWUR���8��N9� �NJ�

����������� 13.8 - 5,6

����������� 11 Ex 5,6

i

09�&211(;

�&0$��DQG

�&06�6\

VWHP

0HGLXP�9ROWDJH

Jack Nottidge
Page 4: Pfisterer Connex High Voltage Motor Connectors 6.6kV - 13.8kV - CMS CONNEX Motor Star Point Connector

65ZZZ�S¿VWHUHU�FRP

$VVHPEO\�$FFHVVRULHV

$VVHPEO\�7RROV�IRU�&211(;�0RWRU�&RQQHFWRUconsisting of:assembly jig; drawing device; soldering device; assembly rods

1R�

�����������

'LVDVVHPEO\�%ULGJH�DQG�$VVHPEO\�/HYHUfor CONNEX Motor Connector and Star Point Bridge

1R�

�����������

i

09�&211(;

�&0$��DQG

�&06�6\

VWHP

0HGLXP�9ROWDJH