10
R MULTI FUNCTION PROCESS CALIBRATOR MODEL NO.- ACM-MFPC

Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

Embed Size (px)

DESCRIPTION

Weiber's Multi-Function Process Calibrator is unique and ideal equipment for research and general applications in the field of measurement and analysis of electricity (electric current) in terms of - voltage current (DC); electrical resistance, frequency, thermocouple, thermo resistance, Switch meter measure, and continuity test.

Citation preview

Page 1: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

R

MULTI FUNCTION PROCESS

CALIBRATOR MODEL NO.- ACM-MFPC

Page 2: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

R

TECHNOLOGIES PVT. LTD.

Weiber's Multi-Function Process Calibrator is unique and ideal equipment for research and general

applications in the field of measurement and analysis of electricity (electric current) in terms of - voltage current

(DC); electrical resistance, frequency, thermocouple, thermo resistance, Switch meter measure, and continuity

test.

MULTI FUNCTION PROCESS

CALIBRATORMODEL NO.- ACM-MFPC

Ÿ Large LCD display of screen

Ÿ Portable and hand-held equipment

Ÿ Easy to operate

Ÿ White LED for backlight

Ÿ Kitchen appliances

Ÿ Washing and drying machines

Ÿ Electrical systems

Ÿ Electronics used in automobile

Major Technical Features

Application

Page 3: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

R

TECHNOLOGIES PVT. LTD.

Range

Resolving Power

Remark

Measuring Range

Accuracy

Range

Resolving Power

Remark

Measuring Range

Accuracy

Range

Resolving Power

Remark

Measuring Range

Accuracy

Range

Resolving Power

Remark

Measuring Range

Accuracy

50 mV

1µV

Input Impedance : about 100 M Ω

5.000 mV - 55.000 mV

0.02 % + 10

500mV

10µV

Input Impedance:about 100 M Ω

10.00mV - 550.00mV

0.02%+2

5V

0.1mV

Input Impedance : about 1 M O

0.1000V - 5.5000V

0.02%+5

50 V

10mV

Input Impedance : about 1 M O

0.00V - 55.00V

0.03 % + 5

Technical Features

MULTI FUNCTION PROCESS

CALIBRATORMODEL NO.- ACM-MFPC

Page 4: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

R

TECHNOLOGIES PVT. LTD.

DC Current

OHM

50 mA

1µA

Input Impedance 10Ω

5.000mA - 55.000mA

0.02%+2

500 Ω About 1 mA exciting

0.01Ω

Plough voltage : about 2.5V not including the

accuracy of down-lead resistance

0.00Ω- 550.00Ω

0.02% + 0.1Ω

5 KΩ About 0.1 mA exciting

0.1Ω

Plough voltage about 2.5V not including the

accuracy of down-lead resistance

0.0000 KΩ; - 5.5000KΩ

0.02%+0.5Ω

Ÿ Range

Ÿ Resolving Power

Ÿ Remark

Ÿ Measuring Range

Ÿ Accuracy

Range

Resolving Power

Remark

Measuring Range

Accuracy

Range

Resolving Power

Remark

Measuring Range

MULTI FUNCTION PROCESS

CALIBRATORMODEL NO.- ACM-MFPC

Page 5: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

R

TECHNOLOGIES PVT. LTD.

Frequency

100Hz

0.1Hz

input impedance: 100 kΩ; or more Square wave at least

1Vp-

p 50% duty cycle

2Hz - 110.0Hz

+/-2

1KHz

1Hz

Input Impedance : 100 kΩ or more Square wave at least

1Vp-p 50% duty cycle

0.100KHz1.100KHz

±2

10KHz

0. 1KHz

Input Impedance : 100 kΩ; or more Square wave at least

1Vp-p 50% duty cycle

10KHz11.0KHz

Range

Resolving Power

Remark

Measuring Range

Accuracy

Range

Resolving Power

Remark

Measuring Range

Accuracy

Range

Resolving Power

Remark

Measuring Range

MULTI FUNCTION PROCESS

CALIBRATORMODEL NO.- ACM-MFPC

Page 6: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

R

TECHNOLOGIES PVT. LTD.

MULTI FUNCTION PROCESS

CALIBRATORMODEL NO.- ACM-MFPC

Thermocouple

R

-40C -1760 C(o)

1 C(o)

-4500 : 1.8 &n- 501760 : 1.5

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

S

- 20ºC ----- 1760ºC

1 ºC

4500 : 1.8 - 501760 : 1.5

dopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

K

- 200ºC ---- 950ºC

0.1ºC

- 2000 : 1.2 ----- 01370 : 0.8

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

E

-200ºC ------ 500 C

0.1C

-2000 : 0.9 01000 : 1.5

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

J

- 200ºC ----- 700ºC

0.1ºC

-2000 : 1.0 ---- 01200 : 0.7

Range :

Measuring Range

Resolving Power

Accuracy

Remark

Range :

Measuring Range :

Resolving Power :

Accuracy :

Remark :

Range :

Measuring Range :

Resolving Power :

Accuracy :

Remark :

Range :

Measuring Range :

Resolving Power :

Accuracy :

Remark :

Range :

Measuring Range :

Resolving Power :

Accuracy :

Page 7: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

MULTI FUNCTION PROCESS

CALIBRATORMODEL NO.- ACM-MFPC

R

TECHNOLOGIES PVT. LTD.

Remark :

Range :

Measuring Range :

Resolving Power :

Accuracy :

Remark :

Range :

Measuring Range :

Resolving Power :

Accuracy :

Remark :

Range :

Measuring Range :

Resolving Power :

Accuracy :

Remark :

Range :

Measuring Range :

Resolving Power :

Accuracy :

Remark :

Range :

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

T

-200C - 400C

1 ºC

-2000 : 1.0 ----- 0400 : 0.7

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

N

-200ºC ----- 1000C

0.1C

-2000 : 1.5 ---- 01300 : 0.9

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

B

400C ---- 1800ºC

1Cº

400800 : 2.2 8001000 : 1.8 10001800 : 1.4

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

PT 100

- 200C ---- 700C

0.1C

- 2000 : 0.5 0400 : 0.7 400850 : 0.8

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

PT 1000

Page 8: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

R

TECHNOLOGIES PVT. LTD.

MULTI FUNCTION PROCESS

CALIBRATOR MODEL NO.- ACM-MFPC

Page 9: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

R

Measuring Range :

Resolving Power :

Accuracy :

Remark :

Range

Measuring Range

TECHNOLOGIES PVT. LTD.

MULTI FUNCTION PROCESS

CALIBRATORMODEL NO.- ACM-MFPC

- 200C ----- 630C

0.1C

- 200100 : 0.22 100300 : 0.3 300630 : 0.4

Adopt ITS-90 thermometric scale not including the accuracy of inner

temperature compensatory error

1 mA (approx.) exciting

CLOSE / OPEN

Switch Meter Measure

Range

Resolving Power

Measuring Range

500 Ω About 1 mA exciting

0.01 Ω

50 Ω vocalism

Continuity Test

Page 10: Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd

www.acmasindia.com | www.acmasglobal.com | www.measuring-meters.com

SALES OFFICE (HONG KONG)

SALES OFFICE (RUSSIA)

Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East,

Sheung Wan, Hong Kong (PRC)

Tel.: 0086-13929598046 | 0086- 18922303099

E-mail.: [email protected]

Inmed Trade Street Ozerkovsky Embankment,

Unit No 50, Straine- 1, Off- 502, Moscow, Russia

E-mail.: [email protected]

Tel.: 0049- 79592345 | Email: [email protected]

TECHNOLOGIES PVT. LTD.

An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485

WHO: GMP Products | GLP Compliant Products

CORPORATE OFFICE/ (INDIA)SHOWROOM

Plot No. 352-353, Sector – 57

Phase- IV Kundli, Sonepat, Haryana - 131028

Land Line No.: +91 - 11- 47619688,

Fax: +91-11-47619788

E-mail.: [email protected]