ELLIPTICAL MOBILE SOLUTIONS, LLC Save Money, Energy Time and Space

Page 2: Micro-Modular Data Center infrastructure

Today’s Data Centre Challenges

Digital Explosion

Worldwide:

Aging Infrastructure:

Rising Energy Use:

Costs Are Out of Control:

Page 3: Micro-Modular Data Center infrastructure

How much electricity would you waste if you cooled your house just to keep the milk cool?

Patented “Closed Loop Cooling” from EMS

brings up to 50%+ Electricity Savings

=

Page 4: Micro-Modular Data Center infrastructure

Industry Change – Containerized Data Centres = Less Capital $ More Efficient

Average Data Centre PUE 2.5 Containerized Data Centres PUE 1.1-1.5 $/Kilowatt of IT: 25,000-15,000 $/Kilowatt of IT: 8,000-4,000 Brick & Mortar Container MMDC

Page 5: Micro-Modular Data Center infrastructure

Resilient Data Centre Infrastructure Platform

EMS Standardized Infrastructure Provides Multi Tier Cross Purpose Disaster

Infrastructure Solutions

Page 6: Micro-Modular Data Center infrastructure

MMDC Cooling Efficiency Characteristics

• “Best Practice” airflow “forces” most efficient method

• Pre Engineered – No airflow analysis required

• Hot Aisle Containment – No remixing of hot air into servers

• Cold Aisle Containment – Delivers 100% of cold air to equipment intake

• Zero Bypass Airflow – Cold air is forced through equipment

Equipment

Cold Air “Raised Floor”

Equipment

Equipment

Equipment

Equipment

Data Centre

Page 7: Micro-Modular Data Center infrastructure

Reduce “Embodied Carbon” by 60%

• Reduced complexity of data centre facilities construction

• Results in less embodied carbon in building shell

• Enables renewable material choices

• Reduced “embodied pollution” of construction process

• “ Cradle to Grave” MMDC is all steel and portable and can be reused in

other locations or recycled at end of life

0%20%40%60%80%

100%

Brick an

d M

ortar

Co

ntain

erized

RecyclableAsset

BuildingShell

Page 8: Micro-Modular Data Center infrastructure

MMDC: Scalable, Mobile Footprint = Less Environmental Impact

Permanent 2000 KW Data Centre

Facility

500 KW Container

500 KW Container

500 KW Container

2MW Brick & Mortar

500 KW Container

Semi Permanent 2MW Containerized

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

40

Portable 2MW MMDC (Containerized)

= Data Centre Size

Page 9: Micro-Modular Data Center infrastructure
Page 10: Micro-Modular Data Center infrastructure

Practical Applications

New Data Center &

Data Center

Consolidation

• HPC

• Cloud Computing

• High Density Zone

• Expansions

R.A.S.E.R. HD

R.A.S.E.R. DX

C3-S.P.E.A.R.

• Disaster

Recovery

• Remote Office

• IT on the Move

• Telco

• Industrial

Page 11: Micro-Modular Data Center infrastructure

R.A.S.E.R. DX Features

C

o

l

d

A

i

s

l

e

H

o

t

A

i

s

l

e

Equipment

Equipment

Equipment

Equipment

Cold Air

• Built-in cooling • 12KW IT load • 42,000 BTU • Vapor cycle “DX”

• Shock and vibration isolation

• Hardened enclosure

• Scalable and modular

• Self-contained

• Mission Critical Venting (Optional)

Compressor Condenser/ Evaporator

Page 12: Micro-Modular Data Center infrastructure

Portable Cloud Computing (Example Solution)

Three Industry Leaders

One Architecture…

Page 13: Micro-Modular Data Center infrastructure

Expand Data Centre Capacity with Energy Efficient High Density Zone

“EXAMPLE SOLUTION”

“Future Growth”

Blade Servers

STORAGE

Page 14: Micro-Modular Data Center infrastructure

R.A.S.E.R. HD Features

• Redundant (N+1 AND 2N), hot swappable

heat exchanger units

• 42U of rack space available in the main

cabinet

• 2 “sidecars” contain heat exchanger (HX)

units

• Sealed environment

• Close coupled cooling allows high

temperature water

• A / B water loops and multiple hot-

swappable fans

• Multiple configurations starting at 20 KW

• 42U of rack space available in the main

cabinet

• 2 “sidecars” contain heat exchanger (HX)

units

• Sealed environment

• Close coupled cooling allows high

temperature water

• A / B water loops and multiple hot-

swappable fans

• NEMA 4 environmental package

• Redundant (N+1 AND 2N), hot swappable

heat exchanger units

• Multiple configurations starting at 20 KW

and growing to 80 KW in a single enclosure

Page 15: Micro-Modular Data Center infrastructure

C³SPEAR Features

• 24U of blade ready space

• 2 Self contained close coupled cooling units support N+1 or 2N closed loop cooling.

• 2.5KW, redundant 2N

• 6KW, redundant N+1

• Power assisted mobility

• NEMA 12 or Option NEMA 4 environmental package

• A/B power input for IT

• A/B power input for cooling

• Custom interconnections available

• Waterproof

• Shielded

• Shock and vibration isolation

Page 16: Micro-Modular Data Center infrastructure

Available Options On All

Active Fire Suppression System • VESDA • HSSD • NOVEC 1230 • F-GAS

Cyber Lock Security System • Stand alone power • 4,000 user event audit trail • Card reader security interface • Enterprise class software • Remote programability

Shock and Vibration Isolation • Protects Equipment while being moved

or relocated • Disaster Tolerant

Page 17: Micro-Modular Data Center infrastructure

Data Centre Challenges Today

Technology Refresh Data Centre Consolidation Energy Saving Initiatives Expensive Build Cost Floor Space Constraints Inflexible Infrastructure

Limited Cooling/ Electrical Capacity Runaway Electrical Bill Cost Expensive Retrofit for High Density Zone Constant Demand for Expansion Under Utilized Compute Resources Virtualization Infrastructure Challenges

Problems Solved

•Up To 50% $ Savings on Electricity •Patented zero bypass cooling system •50-80% More efficient = Green

•Up To 75% Floor Area Savings •25 ft² for EMS enclosures vs. 100 ft² traditional raised floor

•Fireproof and Water Proof •Air Tight Closed Loop System

•Eliminates Shock and Vibration Damage •Patented Equipment Suspension

•Scalable from 1 Micro Data Centre to 100’s; “Pay as You Need” •Purchase cooling, security, fireproofing, raised floor, hot and cold isle

Page 18: Micro-Modular Data Center infrastructure

Micro Modular Data Centres ELLIPTICAL MOBILE SOLUTIONS, LLC

• Save Money – Eliminate costly infrastructure with a self-contained, high-density, cost-effective and energy efficient

data centre.

– Reduce the costs to plan, build and implement your data centre

– Reduce overall operating expenses

• Save Energy – Patented closed loop cooling dramatically cuts cooling and electrical costs

– Significantly reduce data centre’s harmful carbon footprint

• Save Time – Micro-Modular Data Centre’s can be built, fully populated and delivered in weeks vs. months or years

– Have a fully functional data centre when, where and for however long you need it

• Save Space – Reduce your data centre footprint by up to 70 percent

– EMS products can be located in a warehouse, garage, office or closet