15
Evaporative Cooling… revolutionized. TRANSINDUSTRIAL LLC www.transindustrial.c om Phone 602.864.3099 Fax 602.864.2787 6875 North 21 st Ave. #118 Phoenix, AZ – 85015

iCooler Technical Presentation

Embed Size (px)

DESCRIPTION

This presentation describes the parts and pieces of iCooler, as well as the benefits of using the iCooler against the regular old systems.

Citation preview

Page 1: iCooler Technical Presentation

Evaporative Cooling…revolutionized.

TRANSINDUSTRIAL LLC

www.transindustrial.com

Phone 602.864.3099

Fax 602.864.2787

6875 North 21st Ave. #118

Phoenix, AZ – 85015

Page 2: iCooler Technical Presentation

Just about everything today is computer-based.

 

From your household iron… to the engine in your car… Just about everything has a computer!

 

…Why not your Evaporative Cooler?

COMPUTER

Page 3: iCooler Technical Presentation

Evaporation is a phenomenon of nature that this industry has yet to completely understand. TransIndustrial has revisited the basic principles of evaporation and applied them to today’s computer technology. Through research and development,

…they have created the Perfect Evaporative Cooler.

SCIENCE

Page 4: iCooler Technical Presentation

Air entry side of wet section with water supply subassemblies

• Virtually no maintenance

• No pump

• No float

• No standing water

• Computer control patented technology

Custom wet section for Southern Nevada Water Authority

• Substantial water savings

• Predictable operation

• Modular plug and play design

• Easy to install

• Easy to operate

• Will accommodate any system size requirements

Custom Control Unit for

General Dynamics C4

Computer control unit at General Dynamics C4, Arizona

OV

ER

VIE

W

Page 5: iCooler Technical Presentation

patent pending Evaporative Cooling Wet Section

Fully Modular Design

• all major components are pre-fabricated, pre-assembled modular sub-assemblies

• maximizes design flexibility

• system is easily scaled to accommodate any size project

• provides ease of installation

• provides ease of access for service and repair

• minimizes spare parts inventory requirement

Construction

• 304 / 316L Stainless Steel

• all welded structural tube framing

• engineered connectors ensure structural integrity of the finished assembly

• removable air dams, water distribution header, and dry sump for easy service access

• all Sch 80 PVC plumbing

• all NEMA 4X enclosures and junction boxes

Page 6: iCooler Technical Presentation

Water Supply Header

• pre-fabricated modular sub assembly

• slow acting solenoid valve eliminates water hammer

• constant flow control valve assures proper flow regardless of changes in line pressure

• trim valve for fine tuning delivery of water to distribution header

Water Distribution Header

• non-clogging, self-cleaning water distribution tubes

• dual water distribution delivery configuration for more efficient wetting of media

•consistent delivery of water to the media evenly across the full face of the media

• removable water distribution cartridge configuration for ease of serviceability

• adjustable positioning of water distribution tubes relative to face of media

patent pending Evaporative Cooling Wet Section

Page 7: iCooler Technical Presentation

patent pending Evaporative Cooling Wet Section

Evaporative Cooling Media

• 45/15 cross fluted, rigid 12” deep cellulose pad

• equals industry leading quality standards

• equals industry leading performance standards

• 3 year pad life warranty standard

Dry Sump• no standing water, no algae, no obnoxious odors

• no pump, no float

• 3:1 design safety ratio for drain water level high limit holding capacity

• reduced size requirement allows for greater media surface area ratio than other systems

• 1 ½” – 30GPM drain standard

• high water level limit with alarm

• removable for easy service access

• innovative media support design

Page 8: iCooler Technical Presentation

patent pending Computer Control System

• UL 508

• maximizes the efficiency of water use

• optimizes the efficiency of evaporative cooling media

• virtually eliminates scaling of media pads

• self regulating / self cleaning system

• independent start-up and shut-down modes

• adjustable bleed and rinse set points

• process monitoring with alarms

• can be configured for data logging

• can be configured for networking and multiple unit control

• can be configured for remote access

• can provide MTBF analysis and predictive maintenance scheduling

• available with hand held device for system set up, component calibration and process parameter adjustment

Page 9: iCooler Technical Presentation

patent pending Evaporative Cooling System with PLC Unit

FEATURES and BENEFITS

• 24/7/365 finite operating control

• eliminates maintenance problems

• easy to install, easy to access, easy to service

• media does not scale

• local response to changing weather conditions

• real time communication with system

• reduce unplanned system downtime, reduce spare parts inventory

• field set up, calibration, and process parameter adjustment

• operate multiple units with 1 controller

• integrate with existing building maintenance software

• easy service access for repair and replace

• computer control

• no pump, no float, no standing water, no algae, no obnoxious odors

• modular design

• optimizes water use and pad efficiency

• adjustable bleed and rinse set points

• can be configured for remote access

• can provide MTBF analysis and predictive maintenance scheduling

• available with hand held device

• can be configured for networking

• can be configured for data logging

• removable air dams, water supply header, water distribution header, dry sump

LOWER TCO • FASTER ROI

Page 10: iCooler Technical Presentation

SOUTHERN NEVADA WATER AUTHORITY

CONTRACT 310C 01 C1

IPS-1 LARGE EVAPORATIVE COOLER MODIFICATION

TransIndustrial’siCooler

at the Hoover Dam

Page 11: iCooler Technical Presentation
Page 12: iCooler Technical Presentation
Page 13: iCooler Technical Presentation
Page 14: iCooler Technical Presentation

General Dynamics is a market leader in business aviation; land and expeditionary combat vehicles and systems, armaments, and

 

 

FEATURED CUSTOMERS

The Southern Nevada Water Authority (SNWA) is a cooperative agency formed in 1991 to address Southern Nevada's unique water needs on a regional basis. SNWA officials are charged with managing the region's water resources and providing for Las Vegas Valley area residents' and businesses' present and future water needs.

www.snwa.com

El Paso Electric generates and distributes electricity through an interconnected system to approximately 363,000 customers in the Rio Grande Valley in west Texas and southern New Mexico.

www.epelectric.com

munitions; shipbuilding and marine systems; and mission-critical information systems and technologies. The company employs approximately 92,300 people worldwide.

www.generaldynamics.com

Page 15: iCooler Technical Presentation

6875 North 21st Avenue

Phoenix, Arizona

85015

Phone 602-864-3099 Fax 602-864-2787 E-mail [email protected]