30
www.huawei.com Security Level: HUAWEI TECHNOLOGIES CO., LTD. Huawei Future Oriented FTTx Solution

Huawei Capacity Upgrade

Embed Size (px)

DESCRIPTION

Huawei Panel discussion regarding Capacity Upgrade at the Connect 2 Connect Summit 2014, Tanzania

Citation preview

Page 1: Huawei Capacity Upgrade

www.huawei.com

Security Level:

HUAWEI TECHNOLOGIES CO., LTD.

Huawei Future Oriented FTTx Solution

Page 2: Huawei Capacity Upgrade

Content

Network Migration Trends and Huawei Innovation

Solutions of Network Migration

Huawei Capability and Experience

2

1

3

Page 3: Huawei Capacity Upgrade

Page 3HUAWEI TECHNOLOGIES CO., LTD.

Copper Innovations Facilitate Broadband Deployment

FTTB: Fiber to Building FTTD: Fiber to Door BW: VD2(30A,160M@100m) next

G.fast(500M-1Gbps@100m) Reversed power feeding FTTH-like service provisioning

FTTC: Fiber to Curb BW: VD2/Vector(17a, 100M@500m) All in one cabinet, Plug & Play and Pre-

configuration remote DSLAM Intelligent site Line diagnose & optimization

FTTC/B NG FTTBExchange

Commercially Deployed

SuperMIMO

ADSL2 G.992.3/4ADSL2+ G.992.5

100m500m1.5Km3Km 300m0.1M

50M

20M6M

ADSL G.992.1/2

VDSL2 G.993.2

100-300M

Vectoring G.993.5

500-1000M

19992002

In Standardization

20032004

2015-2016

6Km

2012

G.Fast

Bandwidth

BW: VD2/Vector(17a: 120M@250m), next G.fast(500M@200m)

AC, Reversed power feeding or Forward Remote power feeding

Nature cooling

Vectoring is mature now

Giga DSL will roll out in 2015

• Up to 120Mbps for VD2@17a• 2-4 pairs of VD2/Vector bonding

• Giga DSL prototype released by Huawei in July 2012

• 500M-1Gbps in 2015-2016for FTTB/D with G.fast

Page 4: Huawei Capacity Upgrade

Page 4HUAWEI TECHNOLOGIES CO., LTD.

PSTN : End of Service

2011 2012 2013 2014 2015

OPEX

ATM DSLAM : Limited Capacity

ATM DSLAM Required

<5M

25M+

Voice Era HSI Era Triple/Multi-Play Era Long Trail Era

It is Time for Copper Line Migration

reach 360 Million

Source: Dittberner

34517453

136

161 13173

ALE///

HWNSNNotelNEC

Others

• Worldwide PSTN 1 billion ports

• Out of service will reach 360M

Page 5: Huawei Capacity Upgrade

Page 5HUAWEI TECHNOLOGIES CO., LTD.

Content

Network Migration Trends and Huawei Innovation

Solutions of Network Migration

Huawei Capability and Experience

2

1

3

Page 6: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Page 6Huawei Confidential

All in One , One For All, Smooth Evolution

MA5600T Series and MA5616 support POTS/ISDN/xDSL/Vectoring/P2P/GPON/10GPON AccessUnified platform can be reused for evolution, protecting the investment for future

VDSL/ADSL DSL 8~<20M

VoiceCopper Access POTS/ISDN

GE/10GE MSAN/DSLAM

20M

Curb Building Home

xDSL

MA5600T Series

MA5603T

MA5608T

GPON/10G GPON FTTH 100M~1G

FDT

FTTB/C

1.Replace copper with GPON/10GPON2. Move copper cards to remote site

FTTH

1. Deploy FDT in existing remote site

FTTB/C 30~100M

GPON/GE/10G GPON

xDSL/Vectoring

MA5603T

MA5608T

MA5616

MA5616

Page 7: Huawei Capacity Upgrade

Page 7HUAWEI TECHNOLOGIES CO., LTD.

Traditional PSTN Service 100% Inherited

The MA5600T/MA5603T/MA5608T/UA5000 supports various legacy access modes such as POTS, ISDN, TDM private line (E1 and N*64K), and PBX. This feature ensures continuous services over live PSTN network during network migration, no replacement of customer clients, and no deterioration to user experience.

IP/MPLS

Softswitch

POTS

FAX

Polarity reversal

12/16KC

RouterPRA/R2 PBX

ISDN phone

POTS

TDM G.SHDSLE1

H.248 TDM PWE3

MODEM

E1

CPE

FAX

MODEM

ISDN BRA

Router

IMS PWE3 GWDDN

E1/STM-1

SIP

E1Phone

Page 7

Page 8: Huawei Capacity Upgrade

Page 8HUAWEI TECHNOLOGIES CO., LTD.

DSL COMBO : Upgrade to NGN’s Best Choice

48 VD Combo

VDSL2

SPL

POTS

Three-in-one

MDF

Externalline module

Internalline module PSTN

DSLAM

MDF MSANCOMBO

1*cable, 1*MDF, 1*wiringCapacity ↑ 50%

288(6*48) > 192(3*64)

3*cable, 3*MDF, 3*wiring

Workload ↓66% Spare parts ↓50%Training/Power•Huawei is the first launched

•More than 15M applications

Page 9: Huawei Capacity Upgrade

Page 9HUAWEI TECHNOLOGIES CO., LTD.

Huawei “one-stop” outdoor Cabinet Solution4 system, all in one integration, one-stop delivery.

Total cost saving about 20%

One site delivery mode, without integration Main equipment & synchronization

Testing system

Power system with monitoring

Integrate outdoor cabinet

Easy installation, fast deployment

Capacity: Copper:768 COMBO(768 POTS + 768 DSL)

Fiber: 24 cores

Classic Model: (with 1:32 splitter radio)

14 COMBO+2 GPON=(672 POTS+672 DSL+768 FTTH)

Totally: 2112 subscribers!

MDFPower & monitor

Heat exchange unit(with external cycle fan)

High capacity OLT MA5600T

ODF

Battery

Page 10: Huawei Capacity Upgrade

Page 10HUAWEI TECHNOLOGIES CO., LTD.

Fixed Network Line Expert --N2510

CPE MDF DSLAMMSAN

FTU

TAMMDF

Local Test Device

Copper line test (Hardware)

DSLAM/MSAN

CPE

AOSCopper line test (Software)

OLTOTDR

OSU

ONT

MDU

ODF

LTS

Reflector

Optimization (Software)

SNMPU2000 NMS

Web Client

3rd Party Equipment

TL1/XML

OSS

N2510

TL1/XMLTCP/IP

HTTPS

OLS

Copper Fiber

• Support hardware and software test (copper/fiber), flexible choice according to different scenarios .

• Unified platform for copper & fiber test , significantly reducing deployment costs

Page 11: Huawei Capacity Upgrade

Page 11HUAWEI TECHNOLOGIES CO., LTD.

Accurate Faults DemarcationPrecise Fault LocationAccurate Fault Demarcation Proactive O&M

N2510

User ID

OLTBRAS Splitter

Splitter

MDU

ONTA

B DC

EF H

GF

Device Faults Line Faults MDU Faults

• A, B: OLT-BRAS link faults

diagnosed by PPPoE

• C: OLT status diagnosis

• D, E, F: Feeder/distribution

/drop fiber faults diagnosed

by alarm analysis and optical

power monitoring

• G: MDU status diagnosis,

and MDU-BRAS link faults

diagnosed by PPPoE

emulation

User-side faults

• H: ONT status diagnosis,

and ONT service

configuration diagnosis

Page 11

Page 12: Huawei Capacity Upgrade

Page 12HUAWEI TECHNOLOGIES CO., LTD.

Demarcation Between ISP and OSP: Reflector (Optional)

Test wave full reflection

Reflector

Service wave pass through directly

OTDR + reflector implementation:

Demarcation and E2E optical power

attenuation

ODFFDTFAT

OSU

OTDR

ONT

FAT

ATB

Reflector

Reflector

Reflector

Time

Attenuation(dB)User1

User2User3

User 1 drop fiber faultRegular inspection Fault inside building

Reflector detected

Precise Fault LocationAccurate Fault Demarcation Proactive O&M

Without Reflector

Page 12

Page 13: Huawei Capacity Upgrade

Page 13HUAWEI TECHNOLOGIES CO., LTD.

Precise Fault LocationAccurate Fault Demarcation Proactive O&M

Quicken Troubleshooting: OTDR@GIS

OTDR can precisely measure the distance of a fault point from the network node. The N2510 displays the distance from the fault point to the nearest network node based on the GIS.

3

Connected to the GIS, which shows that a fault is

300 m away from the ODF in a residential area.

The optical fibers are working properly.

The OTDR test curves is normal.1

A fault occurs on a fiber. The OTDR test curve shows that the fault distance is 6828 m.

2

The reflection disappears.It is the fault point.

4

Smart terminal guides the engineers on-site troubleshooting, retest.

Page 13

Page 14: Huawei Capacity Upgrade

Page 14HUAWEI TECHNOLOGIES CO., LTD.

To Master Line Health Conditions in Real-time

Automatic monitoring

Thread hold

0102030405060708090

100

3.1 3.2 3.3

Automatic warning

SMSEmail

Requires integrating with work order system

Automatic dispatch

Device ODN Link Service quality

Precise Fault LocationAccurate Fault Demarcation Proactive O&M

Page 14

Page 15: Huawei Capacity Upgrade

Page 15HUAWEI TECHNOLOGIES CO., LTD.

Efficient Inspection

N2510

OLTMDU

MAN and core network

ONT

ODN

WarningAlarm

OTDROTDR monitors the fiber 24/7.

OSU

Reports a warning when detecting faultSet object and period Monitors in real time.

Reports a warning when exceeds the threshold

Locates a fault

1 2

3 4

The OTDR monitors the fiber status periodically, reports a warning when detecting any change

The period and test duration can be set to meet requirements in various scenarios.

Page 15

Page 16: Huawei Capacity Upgrade

Page 16HUAWEI TECHNOLOGIES CO., LTD.

Proactive O&M: Periodically Customized Report

Monitoring link

Monitoring device

Optical module status

Device Status

OPM link attenuation

OTDR E2E attenuation

Network quality

Bandwidth usage

Precise Fault LocationAccurate Fault Demarcation Proactive O&M

Monitoring service

Page 16

Page 17: Huawei Capacity Upgrade

Page 17HUAWEI TECHNOLOGIES CO., LTD.

eOTDR: Accurate Demarcation, Quick Fault Location

Optical module replacement , OLT software upgrade No change of ODN

Easy Deployment

Embedded OTDR Solution

N2510

External OTDR Solution

SNMPTCP/IP

Client

The Third-party Server

OSS

TL1/XML

OLTONU

ODF OSU

ONUOTDRReflector

ONU1

ONU2

ONU3ONU disconnect

Reflector ONU3ODFONU2

ONU1eOTDR TRx

1:8 1:8

Feeder fiber bending

Distribution fiber cut

……

OLT

Accurate fault location, enhancing working efficiency Fast fault address, reduce

invalid dispatch

Reliable Performance

No optical switch/WDM, Low cost OTDR

Without ODN change costs

Low Cost

Page 18: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

N2510 System for FTTX Solution

Fiber and Copper DLM share the same platformProvide the same portal for OSS to start fiber fault diagnosis and copper DLM

NNOC

Closure Closure

ONU/MSAN

Closure Closure

1:32 splitter

Closure

GPON/P2P

Outdoor MSAN(DSL)24~1024Line

N2510 Server

OSS

TL1/XML

OLT ODF

OTDR

OSU

OTDR

OSU

Indoor Office

1:8 splitter

OLTODF

Indoor Office

SNMP

Page 18

Page 19: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Page 19Huawei Confidential

CPE Side Copper line CO Side

DSLAM BRAS

exchangeMDFADSL/ADSL2+/SHDSL/VDSL2

Test capabilities with xTAM +N2510 on Copper Loop Access

DMM

TDR DMT Rate Estimation

Frequency Response

Noise PSD Measurement

Longitude Balance Load Coil Detection

SHDSL Rate Estimation

Pair tone identification

CPE TestxTU-C Simulation

Modem-on Detection

Copper Line Test

Dial Tone Detection

xTU-R Simulation

Ping/TraceRoute

PPPoE/DHCP

HTTP/FTP rate Est

IP / DSLAM Test

Splitter Detection

Modem type Identification

Pair Identification Tone /Break Tone

Other CPE detection(Telephone, PPA / signature)

TMM Bridge tap Break Tone Detection

Page 20: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Page 20Huawei Confidential

DLM Line Optimization

Optimize the line parameter to avoid crosstalk Decreases offline/BER rate, Increase the line utilization ratio.

Line diagnosis

Identify fault range and locate fault point.One-click complete test,95% accuracy and no additional hardware

Evaluate whether the line can support high bandwidth serviceImprove provisioningperiod and protect investment

Line Evaluation

N2510 AOS main features

Rate Reachable Ratio/Bit Error Ratio/Abnormal ResyncRatio/Line length,Analyze the whole network

Line analysis

Page 21: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Copper &Fiber Co-exist in the Longer Term. Technology Developments Will Provide a Longer Life for Copper

Long-term Goal: 100M~1GMidterm Future:50M~100MNear Future: 20M~40MBandwidth

Copper solution: Smooth bandwidth improving, long-term goal 1G bps for each family user.Fiber solution: GPON - > 10G GPON - > 40G GPON smooth upgrading.

Copper

Currently:4~12M

VDSL2 Vectoring G.Fast

ADSL2+

2006~2011 2012~2013 2013~2017 2017+

Fiber

EPON

GPON 10G GPON 40G GPON

Investment Protection, Copper and Fibre supported

Page 21

Page 22: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

E2E Traffic Monitoring-uTraffic

Access Backbone

SNMP/sFTP /Qx

TXT

HTTPs VisualizedVisualized of network traffic, flow trend,

and capacityEvaluable

Active monitoring of E2E Service quality

PredictableNetwork KPI trend analysis and forecast

U2000/NMS U2000/NMS

uTrafficOSS System

FTTx+DSL

PONFTTH

P2P

WiFi

Metro

Page 23: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

E2E Y.1731Network Performance StatisticsE2E Y.1731 was provided by ONT/OLT/U2000/uTraffic

OLT & ONT real-time report packet loss, delay, jitter statistics, calculated to uTraffic

uTraffic analyses data and state reportUPE

Aggregation

AGG

NBN

OLTONT

VLANVPLSVLAN

MEP

UNI E-NNIU2000/uTraffic

Network traffic quality statements report Network traffic quality history data of delay

SPUF

Specification:Frame Loss Measurement (Single-ended ETH-LM),

Delay Measurement (ETH-DM, two-way delay)Two-way delay accuracy:100us

Support uplink MEP & downlink MEP @SPUF, uplink MEP @OPGD

BenefitsOLT & ONT real-time report packet loss, delay, jitter statistics,

calculated to uTrafficuTraffic analyses data and state report

U2000 for config and connectivity mgmt, uTraffic for performance mgmt

Page 24: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Page 24Huawei Confidential

GPON & NG PON

10GPON ONT:1*10GE+4*1GE+2*POTS+WiFi

TV WDM-XR

GPON

MA5600T

10GPON

Spirent Tester

H8240

40GPON

1:32

1:8

TV

20km

TV

40GPON ONT

40GPON ONT

40GPON ONT

40GPON ONT

10GPON trial: first 10GPON user (BT staff) connected in July 2012 40GPON demo: Plug in 16*GPON, 4*10GPON, 1*40GPON cards in existing

OLT (SCUH, 40G/slot), demoed co-exist of GPON, 10GPON and 40GPON

Page 25: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Page 25Huawei Confidential

SingleFAN2.0:build On-Demand HetAN

@Move

@Home

@Office

Coax

CAT5

D-CMTS

CO Core

OneArchitecture

OneSoftware

• SingleFAN2.0 support bandwidth, location, media and connection on-demand.• SingleFAN2.0 help carriers to achieve shorter TTM, lower TCO and quicker ROI• Line Assurance system N2510 also support copper and fiber line management in same platform

IP/Opt

OLT

connectionon-demand

UniversalManagementbandwidth

on-demand

HetAN: Heterogeneous Access Network

Page 26: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Page 26Huawei Confidential

FTTH Maintenance via Mobile APPSmart Home Application Interconnection Test & Diagnostics

Page 27: Huawei Capacity Upgrade

Content

Network Migration Trends and Huawei Innovation

Solutions of Network Migration

Huawei Capability and Experience

2

1

3

Page 28: Huawei Capacity Upgrade

Page 28HUAWEI TECHNOLOGIES CO., LTD.

Huawei PSTN / DSLAM Migration Reference List

Delivery projects

South Africa Telkom

Ghana VDF

Monaco Telecom

Indonesia Telkom

Philippines PLDTMalaysia telecomThailand TOTHongKong PCCW

Poland TPSAHungary MTAustria TACroatia HT

British BT&TTT Belgium BGCGermany T-O2France SFRFrance BytelItaly TI

Brazil Telesp

Venezuela CANTV

Argentina AT

Ecuador

Key points: 1. Most of the customer selects MA5600T singleFAN platform2. They like toe COMBO and N2510 line assurance system (like Telkom SA)3. Some of them selects MA5616 for outdoor cabinets (like BGC; TT)

China Telecom

Turkey TTPakistan

STC

Kenya TKL

Page 28

Page 29: Huawei Capacity Upgrade

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential

Challenges

Benefits

Solutions:

TDM switches is old, OPEX is very high , no support and spare part from the vendor Single voice service is decreasing ARPU rapidly Strong requirement for Broadband

Universal platform for MSAN/OLT, one chassis for copper and fiber access, with high density service card

100% inherit traditional services, include POTS/ISDN BRA/ISDN PRA; ready for future update

Choose COMBO cards in remote site , POTS/VDSL2/SPL in one card, deploy two services one time

N2510 for copper line test and bandwidth optimization

Telkom SA: PSTN Migration with COMBO Cards

Save TCO with the end to end migration solution, include MSAN/OLT,LTS, street cabinet COMBO helps Telkom to deploy services quickly , win the competition

Achievement :

• 400 CO sites, 150 Outdoor sites

• 700,000 lines POTS , ADSL2+/VDSL2

Page 29

Page 30: Huawei Capacity Upgrade

Thank youwww.huawei.com