11
Tony Ford Gnodal Guest Speaker Presentation

Gnodal Presentation at Spirent Booth, Interop 2012

Embed Size (px)

DESCRIPTION

Tony Ford, COO Gnodal, presentation at the Spirent booth, Interop 2012. Gnodal GS Series: - Lowest latency - Highest density - 10/40 GbE - High scalability - Low power - Multi-path load-balancing - Congestion free architecture, dynamic re-routing Get more info about low latency testing with Spirent TestCenter HyperMetrics dX: http://bit.ly/JJy2mf

Citation preview

Page 1: Gnodal Presentation at Spirent Booth, Interop 2012

Tony FordGnodal

Guest Speaker

Presentation

Page 2: Gnodal Presentation at Spirent Booth, Interop 2012

Gnodal Gnodal GS Series Lowest latency Highest density 10/40 GbE High scalability Low power Multi-path load-balancing Congestion free architecture,

dynamic re-routing

Scalable Ultra-low Latency

10/40 Gigabit Ethernet

http://www.gnodal.com

Booth #434

Page 3: Gnodal Presentation at Spirent Booth, Interop 2012

GS Series 1U Platforms

GS0072 - 72 x 10 GbEGS4008 - 40 x 10 GbE + 8 x 40GbEGS0018 -18 x 40 GbE

Page 4: Gnodal Presentation at Spirent Booth, Interop 2012

GS Series Platforms – Latest addition

GS0072 - Best of Interop Winner 2012 - Networks

Page 5: Gnodal Presentation at Spirent Booth, Interop 2012

Latency Testing Test bed – Single switch

GS4008

9 17 19 21 23

18 20 22 24

25 27 29 31

26 28 30 32

33 35

34 36

1

135

45 53 55 57 59

54 56 58 60

61 63 65 67

62 64 66 68

69 71

70 72

37

4941

0

1

2

3 4 5 6 7 8

9

10

11

12 13 14 15 16 17

5m fibre

5m fibre

5m fibre

5m fibre

5m fibre

5m fibre

5m fibre

5m fibre

Page 6: Gnodal Presentation at Spirent Booth, Interop 2012

Test Results Analysis – Single switch

Page 7: Gnodal Presentation at Spirent Booth, Interop 2012

Latency Testing Test bed – 2880 ports

9 17 19 21 23

18 20 22 24

25 27 29 31

26 28 30 32

33 35

34 36

1

135

45 53 55 57 59

54 56 58 60

61 63 65 67

62 64 66 68

69 71

70 72

37

4941

0

1

2

3 4 5 6 7 8

9

10

11

12 13 14 15 16 17

5m fibre

5m fibre

5m fibre

5m fibre

9 17 19 21 23

18 20 22 24

25 27 29 31

26 28 30 32

33 35

34 36

1

135

45 53 55 57 59

54 56 58 60

61 63 65 67

62 64 66 68

69 71

70 72

37

4941

0

1

2

3 4 5 6 7 8

9

10

11

12 13 14 15 16 17

5m fibre

5m fibre

5m fibre

5m fibre

73

18

77

19

81

20

85

21

89

22

93

23

97

24

101

25

105

26

109

27

113

28

117

29

121

30

125

31

129

32

133

33

137

34

141

35

1

0

5

1

9

2

13

3

17

4

21

5

25

6

29

7

33

8

37

9

41

10

45

11

49

12

53

13

57

14

61

15

65

16

69

17

217

54

221

55

225

56

229

57

233

58

237

59

241

60

245

61

249

62

253

63

257

64

261

65

265

66

269

67

273

68

277

69

281

70

285

71

145

36

149

37

153

38

157

39

161

40

165

41

169

42

173

43

177

44

181

45

185

46

189

47

193

48

197

49

201

50

205

51

209

52

213

53

3m copper

3m copper

GS4008

GS0072

GS4008

Page 8: Gnodal Presentation at Spirent Booth, Interop 2012

Test Results Analysis - 2880 ports

Page 9: Gnodal Presentation at Spirent Booth, Interop 2012

Test Results Analysis

Measured Results72 ports - 150ns for single hop136 ports - 230ns for two hops (150ns first hop, 15ns of cable delay, 65ns for additional hop)720 ports - 310ns for three hops (150ns first hop, 2x 15ns cable delay, 2x 65ns additional hops)2880 ports - 440ns for five hops (150ns first hop, 2x 15ns cable delay, 4x 65ns additional hops)

64 128 256 512 1024 1280 15180

50

100

150

200

250

300

350

400

450

500

Minimum Latency

GS4008

GS4008/GS4008

GS4008/GS0018/GS4008

GS4008/GS0072/GS4008

Packet size (B)

Lat

ency

(n

s)

Page 10: Gnodal Presentation at Spirent Booth, Interop 2012

Final Thoughts Be clear about test requirements

• Single switch – lowest latency

• Multi-chassis – highest scalability

Ultra-low latency switches require ultra-low latency test equipment• Application-space tests introduce artifacts

• Industry validation through recognized, trusted partners - Spirent

Speed-of-light benchmarks• Secondary effects can significantly effect performance

• Congestion, Load-balancing, Multi-chassis control plane

To hear how we address these issues visit our booth #434 or

http://www.gnodal.com

Page 11: Gnodal Presentation at Spirent Booth, Interop 2012

spirent.com/tws