7
FLAVORx Inc, 9475 Gerwig Lane, Columbia, MD 21046 | 800.884.5771 | www.flavorx.com 1 FILLMASTER PLUS

FLAVORx University - Fillmaster Plus

Embed Size (px)

Citation preview

Page 1: FLAVORx University - Fillmaster Plus

FLAVORx Inc, 9475 Gerwig Lane, Columbia, MD 21046 | 800.884.5771 | www.flavorx.com 1

FILLMASTER PLUS

Page 2: FLAVORx University - Fillmaster Plus

FLAVORx Inc, 9475 Gerwig Lane, Columbia, MD 21046 | 800.884.5771 | www.flavorx.com

SECTION SECTION TITLE SLIDE#

1 Information Layout Slide with Table 3

2 Information Layout Slide with Bar Graph 4

3 Information Layout Slide with Pie Chart 5

4 Closing Slide – Thank You 6

Table of Contents

2

Page 3: FLAVORx University - Fillmaster Plus

FLAVORx Inc, 9475 Gerwig Lane, Columbia, MD 21046 | 800.884.5771 | www.flavorx.com

Fillmaster Plus

3

Page 4: FLAVORx University - Fillmaster Plus

FLAVORx Inc, 9475 Gerwig Lane, Columbia, MD 21046 | 800.884.5771 | www.flavorx.com

for reconstitution and flavoring

STEP 1: Press the “Scan” button

STEP 2: Scan the NDC barcode on the medication bottle and confirm the drug name, strength & volume (the scanner is found to the left of the keypad and only lights up when the scan function is activated)

STEP 3: Press “3” on the keypad to reconstitute and flavor

STEP 4: Select the flavor of choice and confirm the selection

STEP 5: Press “Dispense” to begin the reconstitution process

STEP 6: After reconstitution is complete, follow the screen prompts to dispense the appropriate amount of flavoring ingredients using graduated syringes

4

Page 5: FLAVORx University - Fillmaster Plus

FLAVORx Inc, 9475 Gerwig Lane, Columbia, MD 21046 | 800.884.5771 | www.flavorx.com

for reconsitution only

STEP 1: Press the “Scan” button

STEP 2: Scan the NDC barcode on the medication bottle (do not cover the barcode with the prescription la bel) and confirm the drug name, strength & volume

STEP 3: Press “1” on the keypad to reconstitute

STEP 4: Press “Dispense” to begin the reconstitution process

5

Page 6: FLAVORx University - Fillmaster Plus

FLAVORx Inc, 9475 Gerwig Lane, Columbia, MD 21046 | 800.884.5771 | www.flavorx.com

For flavoring only

STEP 1: Press the “Scan” button

STEP 2: Scan the NDC barcode on the medication bottle (do not cover the barcode with the prescription la bel) and confirm the drug name, strength & volume

STEP 3: Press “2” on the keypad for flavoring instructions

STEP 4: Select the flavor of choice and confirm the selection

STEP 5: (Optional) Enter the volume of medication being dispensed

STEP 6: Follow the screen prompts to dispense the appropriate mL amount of flavoring ingredients using gradu ated syringes

6

Page 7: FLAVORx University - Fillmaster Plus

FLAVORx Inc, 9475 Gerwig Lane, Columbia, MD 21046 | 800.884.5771 | www.flavorx.com

Additional functions

• To enter NDC numbers directly without scanning if so de sired, simply press “1” at the startup screen.

• To enter water amounts manually for reconstitution, simply press “2” at the startup screen and enter the amount of water, in mL’s, needed for reconstitution. You will not be able to get flavoring formulations using this option.

• To calibrate the machine, press the “Menu” button and then “3”. Follow the screen prompts to calibrate. Be sure to have a graduated cylinder for precise calibration.

• If the device freezes, simply hold down the “Start” button for 5 seconds to reboot.

7