30
training presence Control PRO IR Quattro COM1/COM2

Fine movement occupancy sensor for HVAC and lighting control

Embed Size (px)

DESCRIPTION

360 degree Ceiling mount PIR presence sensor / occupancy sensor - Dual channel for HVAC and lighting control

Citation preview

Page 1: Fine movement occupancy sensor for HVAC and lighting control

training presence Control PRO IR Quattro COM1/COM2

Page 2: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

Control PRO System

presence control PRO IR quattro HD presence control PRO HF 360presence control PRO DUAL HF

Page 3: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

Control PRO System

fire control PROair control PRO

Page 4: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

mounting

(1) Output module

(2) Sensor module

(10) Flush mounting box

(11) Surface mounting box

(IP 54)

(12) Lock mechanism

IP 54

Page 5: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

presence Control PRO IR Quattro

• 1 pyro infrared sensor

• 1760 switching zones for very precise coverage

• room-typical, square detection zone

• Tangential: 7 x 7 m

• Radial: 5 x 5 m

• Presence: 4 x 4 m

• mechanical reach setting

• IP 20

• Accessories: surface mounting box (IP 54), flush mounting box with holding clamps, remote control RC3, remote control RC4, remote control RC5,

mounting height 3 m

Page 6: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions IR Quattro COM1

(3) bottom side sensor module

(4) dip-switches

• Normal-/Test-mode

• full-/semiautomatic

• momentary switch/switch

• switch ON/ON-OFF

(5) twilight setting

(6) time setting switch contact 1

(9) mechanical reach setting

Page 7: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

(5) twilight setting

• 10 – 1000 lux with 6 typical room situations (stepless) (eg. 1 = corridor ca. 100 Lux)

• left stop night mode

• right stop day mode

(6) time setting switch contact 1

• depending on occupancy and light level

• 30 sec. – 30 min.

• impulse modeeg. for stairway automats

• IQ-modeintelligent selflearning time setting dependingthe specific pattern of room use

functions IR Quattro COM1

Page 8: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions IR Quattro COM1

(4) Dip-switches

• Normal-/Test-mode

Test-mode:

- load independent test-mode - 8 sec. ON- without connected load adjustable- blue LED blink at detection - to proof functionality and detection zone

Normal-mode:

- works depending on settings by trimpods and dip-switches

Page 9: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions IR Quattro COM1

(4) dip-switches

• full-/semiautomatic

fullautomatic:

- automatic ON / automatic OFF depending on occupancy and light level

- manual control possible

semiautomatic:

- manual ON / automatic OFF

- manual OFF possible

- after using a switch lights switch ON and sensor mode starts depending on trimpod and dip switch setting

Page 10: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions IR Quattro COM1

(4) dip-switches

• momentary switch/switch

momentary switch:

- use with external momentary switch

switch:

- use with external switch

Page 11: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions IR Quattro COM1

(4) dip-switches

• ON/ON-OFF

ON:

- no manuall OFF possible

- push on switch restarts run down time

ON-OFF:

- manual ON & OFF possible

Page 12: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions IR Quattro COM1

(9) mechanical reach setting

• 7 „orientation points“ on bottom side of the sensor

• at a mounting height of 3 m the number chosen with the trimpod means the length of the square side for tangential detection

• „translation table“ for different mounting heights and radial respectively presence detection in the owners manual

Page 13: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions IR Quattro COM1

(3) bottom side sensor module

(4) dip-switches

• Normal-/Test-mode

• full-/semiautomatic

• momentary switch/switch

• switch ON/ON-OFF

(5) twilight setting

(6) time setting switch contact 1

(7) time setting switch contact 2 (PF)

(8) time delay switch contact 2

(9) mechanical reach setting

Page 14: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions IR Quattro COM2

(7) time setting switch contact 2 (PF)

- run down time of the hvac Schaltkontakts von 1 Min. bis 2 Stunden

(8) time delay switch contact 2 (PF)

- switch-on delay switch contact 2 from 30 sec. to 10 min.

- room observation

- only if the room is used really the hvac contact will be switched

- a short look into the room will be ignored

Page 15: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

crosslinking of the sensors

Master/Slave:

- Slaves only report occupancy to the Master

- only the Master switches the load

- switching only depending on the Master settings

Master/Master:

- all Masters report occupancy to each other

- every Master switches ist own load depending on ist own settings

Master: load connected

Slave: no load connected

Page 16: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions remote control RC3 (service)

reach setting HF/US sensors

Reset to trimpod & dip settings

Teach IN

twilight setting

Reduce sensitivity

time setting switch contact 2 (hvac)

time setting switch contact 1 (light)

Page 17: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions remote control RC4 (DIM)

Reset to trimpod & dip settings

4 hours manual override

set dimming level

Page 18: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

functions remote control RC5 (DALI)

Reset to trimpod & dip settings

Save/load scene

set dim level

Manual override

set dim level

Manual override

Page 19: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

precise coverage by 1760 switching zones

IR Quattro

Page 20: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

very precise coverage by more than 4000 switching zones

IR Quattro HD

Page 21: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

coverage of different presence detectors (presence detection area)

STEINEL IR Quattro STEINEL IR Quattro HD standard motion detector

Busch Jäger PräsenzTech

Page 22: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

more than 4000 switching zones for very precise coverage

Page 23: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

more than 4000 switching zones for very precise coverage

Page 24: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

roomtypical square detection

7m

7m

detection reach (mounting height 3m):

- squares: Steinel IR Quattro- circles: competitors presence detector

- inner area: presence detection

Steinel: 4x4m detection squarecompetitor: circle Ø 4m

- middle area: radial detectionSteinel: 5x5m detection squarecompetitor: circle Ø 6m

- outer area: tangential detectionSteinel: 7x7m detection squarecompetitor: circle Ø8m

Page 25: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

roomtypical square detection

Page 26: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

roomtypical square detection

Page 27: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

auch Bereiche innerhalb der einzelnen Bürosnicht erfasst

USP´s

roomtypical square detection

Page 28: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

mechanical reach setting

-

Page 29: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

USP´s

tangentiale Erfassung

radiale Erfassung

Präsenzerfassung

- Reduzierung auf den reinen - alle Erfassungsbereiche werden elektronischPräsenzbereich runtergeregelt, so dass der Präsenzbereich

- radiale und tangentiale Erfassung auf Ø 2m eingeschränkt wirdwerden "abgeschnitten" - radiale und tangentiale Erfassung bleibt vorhanden!

reduziert auf 4 x 4 m reduziert Ø 4m

mechanical reach setting

reduced to 4x4m reduced to Ø 4m

tangential detection

radial detection

presence detection

- reduced to presence detection only

- radial & tanegntial detection are „cut off“

- all detection zones are sized down detection only

- radial & tanegential detection are „cut off“

Page 30: Fine movement occupancy sensor for HVAC and lighting control

Pammvi Group of CompaniesEmail: [email protected]: +91 22 2673 1904

Ausblick

sensor modules:

IR Quattro (1 Pyro)

IR Quattro HD (4 Pyros)

HF 360° (HF bar antenna)

DUAL HF (2 HF Patch antennas)

AirControl

FireControl

output modules:

COM1 (1 Relais)

COM2 (1+1 PF Relais)

DIM (1-10V)

KNX

DALI

Impulser

flat surface mounting version

Accessories: surface mounting adapter (IP 54), surface mounting adapter KNX/DALI, flush-mounting adapter (with holding clamps), service remote control, DIM remote control, DALI remote control, protection basket