2
1 Visit us @ www.thearyatechnologies.com Email: [email protected] info@thearyatechnologies.com Contact us@ 0253-2512131 ATK-MQ131-GAS SENSOR GAS SENSOR Overview Sensitive material of MQ-131 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, The sensor’s conductivity is more higher along with the gas concentration rising. Please use simple electro circuit, Convert change of conductivity to correspond output signal of gas concentration. MQ-131 gas sensor has high sensitivity detecting Of O3, also sensitive to CL2, NO2, etc Features Operating voltage: 5V Provide both digital and analog output Adjustable sensitivity Output LED indicator Compatible with Arduino and Microcontroller TTL Compatible Onboard holes for easy installation

Digital & Analog Out MQ131 Sensor

Embed Size (px)

Citation preview

Page 1: Digital & Analog Out MQ131 Sensor

1

Visit us @ www.thearyatechnologies.com

Email: [email protected]

[email protected]

Contact us@ 0253-2512131

ATK-MQ131-GAS SENSOR

GAS SENSOR

Overview

Sensitive material of MQ-131 gas sensor is SnO2, which with lower conductivity

in clean air. When the target combustible gas exist, The sensor’s conductivity is

more higher along with the gas concentration rising. Please use simple electro

circuit, Convert change of conductivity to correspond output signal of gas

concentration.

MQ-131 gas sensor has high sensitivity detecting Of O3, also sensitive to CL2,

NO2, etc

Features

Operating voltage: 5V Provide both digital and analog output Adjustable sensitivity Output LED indicator Compatible with Arduino and Microcontroller TTL Compatible Onboard holes for easy installation

Page 2: Digital & Analog Out MQ131 Sensor

2

Applications

Consumer electronics.

They are used in air quality control equipments for

buildings/offices, are suitable for detecting Of O3.

Specifications

Parameter Min Typ Max Units

Working Voltage 4.5 5 8 Volts

Range 0-4.6 Volts

Pin Diagram

Pin Pin Name

Pin Name

+5V I/P Regulated 5V supply input

GND GND Ground level of power supply

DO O/P Digital Output to external devices

AO O/P Analog Output to ADC

Note: Initially the sensor gives high output so power on the sensor for 15minites

because it needs initially heating voltage then and then it gives proper output.

More info refer the datasheet for the same.

Recommend separate power supply because its required more current to heat.