Upload
adam-thompson
View
1.614
Download
3
Tags:
Embed Size (px)
Citation preview
Adam Thompson, EMT-P, AS
ObjectivesObjectives
Review respiratory systemLearn the terms of capnographyLearn the uses of capnographyReview confirmation of intubationReview ventilatory usesReview circulatory usesReview metabolism usesPractice scenarios
Review respiratory systemLearn the terms of capnographyLearn the uses of capnographyReview confirmation of intubationReview ventilatory usesReview circulatory usesReview metabolism usesPractice scenarios
Respiratory SystemRespiratory System
Exchange O2 for CO2Air enters nose &
mouthO2 is exchanged for
CO2 in alveoliO2 is transported to
the body and exchanged for CO2 again
Exchange O2 for CO2Air enters nose &
mouthO2 is exchanged for
CO2 in alveoliO2 is transported to
the body and exchanged for CO2 again
Nasal Passages
Roof of the Mouth
Epiglottis
Trachea (windpipe)
Esophagus (food tube)
Alveoli
BronchiPulmonary VeinBronchiole
Nasal Passages
Roof of the Mouth
Epiglottis
Trachea (windpipe)
Esophagus (food tube)
Alveoli
BronchiPulmonary VeinBronchiole
The heart pumps the freshly oxygenated blood throughout the body to the cells where oxygen is consumed (metabolism), and carbon dioxide, produced as a byproduct, diffuses out of the cells into the vascular system.
Respiratory SystemRespiratory System
Carbon dioxide rich blood is then pumped through the pulmonary capillary bed where the carbon dioxidediffuses across the alveolar capillary membrane and is exhaled via the nose or mouth.
Carbon dioxide rich blood is then pumped through the pulmonary capillary bed where the carbon dioxidediffuses across the alveolar capillary membrane and is exhaled via the nose or mouth.
Respiratory SystemRespiratory System
TerminologyTerminology
Capnometry The numeric value
Capnometry The numeric value
45mmHg
TerminologyTerminology
Capnometry The numeric value
Capnometry The numeric value
40
0
CO2: 38
TerminologyTerminology
Capnogram The waveform
Capnogram The waveform
40
0
A
B C
D
TerminologyTerminology
The capnogram measures expired CO2. The plateau signifies expiration
The capnogram measures expired CO2. The plateau signifies expiration
40
0
A
B C
D
TerminologyTerminology
ETCO2 (PeCO2) = End-Tidal CO2
CO2 = Carbon Dioxide Carbon dioxide is the by-product of all
metabolism, and is eliminated by exhaling.
ETCO2 (PeCO2) = End-Tidal CO2
CO2 = Carbon Dioxide Carbon dioxide is the by-product of all
metabolism, and is eliminated by exhaling.
O2Body
TissuesCellular
Metabolism
Carbon DioxideLungs
TerminologyTerminology
ETCO2 = C on the image below End-tidal CO2 is measured at the end of
expiration. The highest level of expired CO2 is ETCO2
ETCO2 = C on the image below End-tidal CO2 is measured at the end of
expiration. The highest level of expired CO2 is ETCO2
40
0
A
B C
D
CapnographyCapnography
CO2 detected with infra Red sensorSide-stream & Main-stream ETCO2
CO2 detected with infra Red sensorSide-stream & Main-stream ETCO2
Use of CapnographyUse of Capnography
Confirm ET-Tube PlacementMeasure of VentilationMeasure of Cardiac OutputMeasure of Cellular Metabolism
Confirm ET-Tube PlacementMeasure of VentilationMeasure of Cardiac OutputMeasure of Cellular Metabolism
Ven
tilat
ion C
irculation
Metabolism
Use of CapnographyUse of Capnography
Continuous waveform capnography is recommended in addition to clinical assessment as the most reliable method of confirming and monitoring correct placement of an endotracheal tube (Class I, LOE A). 2010 AHA Recommendations
Continuous waveform capnography is recommended in addition to clinical assessment as the most reliable method of confirming and monitoring correct placement of an endotracheal tube (Class I, LOE A). 2010 AHA Recommendations
Use of CapnographyUse of Capnography
Studies on wave form capnography "have shown 100% sensitivity and 100% specificity in identifying correct endotracheal tube placement.”
Colormetric ETCO2 devices should only be used "when waveform capnography is not available (Class IIa, LOE B)."
Studies on wave form capnography "have shown 100% sensitivity and 100% specificity in identifying correct endotracheal tube placement.”
Colormetric ETCO2 devices should only be used "when waveform capnography is not available (Class IIa, LOE B)."
Use of CapnographyUse of Capnography
It is reasonable to consider using quantitative waveform capnography in intubated patients to monitor CPR quality, optimize chest compressions, and detect ROSC during chest compressions or when rhythm check reveals an organized rhythm (Class IIb, LOE C). 2010 AHA Recommendations
It is reasonable to consider using quantitative waveform capnography in intubated patients to monitor CPR quality, optimize chest compressions, and detect ROSC during chest compressions or when rhythm check reveals an organized rhythm (Class IIb, LOE C). 2010 AHA Recommendations
Use of CapnographyUse of Capnography
If PETCO2 abruptly increases to a normal value (35 to 40 mm Hg), it is reasonable to consider that this is an indicator of ROSC (Class IIa, LOE B). 2010 AHA Recommendations
If PETCO2 abruptly increases to a normal value (35 to 40 mm Hg), it is reasonable to consider that this is an indicator of ROSC (Class IIa, LOE B). 2010 AHA Recommendations
CapnographyCapnography
40
0
CO2: 38
Circulation Ventilation
Metabolism
Oxygenation vs.VentilationOxygenation vs.Ventilation
Oxygenation Ventilation
Measured with pulse oximeter Measured by capnography
Changes take a long time to display Changes display instantly
Oxygenation is how we get oxygen to the tissue. Oxygen is inhaled into the lungs where gas exchange occurs at the capillary-alveolar membrane. Oxygen is transported to the tissues through the blood stream.
Ventilation (the movement of air) is how we get rid of carbon dioxide. Carbon dioxide is carried back through the blood and exhaled by the lungs through the alveoli.
Capnography vs OximeteryCapnography vs Oximetery
Capnography gives an immediate picture of the patient’s condition.
Pulse oximetry is delayed.
If you hold your breath… Capnography will show immediate apnea. O2 Saturations will remain normal for a
prolonged period of time.
Capnography gives an immediate picture of the patient’s condition.
Pulse oximetry is delayed.
If you hold your breath… Capnography will show immediate apnea. O2 Saturations will remain normal for a
prolonged period of time.
Circulation & MetabolismCirculation & Metabolism
While capnography is a direct measurement of ventilation in the lungs, it also indirectly measures metabolism and circulation. Increased Cardiac Output = Increased ETCO2 Decreased Cardiac Output = Decreased ETCO2
“O2 is the smoke from the flames of metabolism.”
-Ray Fowler, M.D. Dallas, Street Doc’s Society
While capnography is a direct measurement of ventilation in the lungs, it also indirectly measures metabolism and circulation. Increased Cardiac Output = Increased ETCO2 Decreased Cardiac Output = Decreased ETCO2
“O2 is the smoke from the flames of metabolism.”
-Ray Fowler, M.D. Dallas, Street Doc’s Society
PaCO2 vs. PeTCO2 PaCO2 vs. PeTCO2
PaCO2= Partial Pressure of Carbon Dioxide in arterial blood gases. The PaCO2 is measured by drawing the
ABGs, which also measure the arterial PH.If ventilation and perfusion are stable
PaCO2 should correlate to PetCO2.
PaCO2= Partial Pressure of Carbon Dioxide in arterial blood gases. The PaCO2 is measured by drawing the
ABGs, which also measure the arterial PH.If ventilation and perfusion are stable
PaCO2 should correlate to PetCO2.
V/Q MismatchV/Q Mismatch
If ventilation or perfusion are unstable, a Ventilation/Perfusion (V/Q) mismatch can occur.
This will alter the correlation between PaC02 and PetCO2.
This V/Q mismatch can be caused by blood shunting.
If ventilation or perfusion are unstable, a Ventilation/Perfusion (V/Q) mismatch can occur.
This will alter the correlation between PaC02 and PetCO2.
This V/Q mismatch can be caused by blood shunting.
Normal ETCO2Normal ETCO2
Normal ETCO2 35 to 45 mmHg
*Alterations in nasopharyngeal anatomy, and device obstruction may alter the ETCO2 reading.
Normal ETCO2 35 to 45 mmHg
*Alterations in nasopharyngeal anatomy, and device obstruction may alter the ETCO2 reading.
ETCO2ETCO2
A is the start of alveolar expirationA-B is the exhalation upstroke where
dead space gas mixes with lung gas
A is the start of alveolar expirationA-B is the exhalation upstroke where
dead space gas mixes with lung gas
40
0
A
B C
D A
B C
D
ETCO2ETCO2
B-C is the continuation of exhalation, or the plateau(all the gas is alveolar now, rich in C02)
B-C is the continuation of exhalation, or the plateau(all the gas is alveolar now, rich in C02)
40
0
A
B C
D A
B C
D
ETCO2ETCO2
C is the end-tidal value - the peak concentration
C is the end-tidal value - the peak concentration
40
0
A
B C
D A
B C
D
ETCO2ETCO2
C-D is the inspiration washoutD-A is post inspiration/dead space
exhalation
C-D is the inspiration washoutD-A is post inspiration/dead space
exhalation
40
0
A
B C
D A
B C
D
Abnormal ETCO2Abnormal ETCO2
ETCO2 Less Than 35 mmHg "Hypocapnia” Respiratory Alkalosis
ETCO2 Greater Than 45 mmHg "Hypercapnia” Respiratory Acidosis
“End-Tidal CO2 reading without a waveform is like a heart rate without an ECG recording.”
-Bob Page, Riding the Waves
ETCO2 Less Than 35 mmHg "Hypocapnia” Respiratory Alkalosis
ETCO2 Greater Than 45 mmHg "Hypercapnia” Respiratory Acidosis
“End-Tidal CO2 reading without a waveform is like a heart rate without an ECG recording.”
-Bob Page, Riding the Waves
IntubationIntubation
There is no better indicator of proper ET-Tube placement than waveform capnography.
The presence of a waveform indicates a tube is correctly placed in the trachea.
There is no better indicator of proper ET-Tube placement than waveform capnography.
The presence of a waveform indicates a tube is correctly placed in the trachea.
Bad TubeGood Tube
IntubationIntubation
ETCO2 = 0 mmHg The tube is in the esophagus!!! Cardiac arrest with prolonged downtime Spontaneous apnea
ETCO2 = 0 mmHg The tube is in the esophagus!!! Cardiac arrest with prolonged downtime Spontaneous apnea
IntubationIntubation
Intubated patient with ETCO2 of 0 mmHg
DOPE Pneumonic D - Dislodgement O - Obstruction P - Pneumothorax E - Equipment
Intubated patient with ETCO2 of 0 mmHg
DOPE Pneumonic D - Dislodgement O - Obstruction P - Pneumothorax E - Equipment
IntubationIntubation
Intubated patient with ETCO2 of 0 mmHg
DOPE Pneumonic D - Dislodgement - check the tube! O - Obstruction - suction P - Pneumothorax - check lung sounds E - Equipment - check the vent
Intubated patient with ETCO2 of 0 mmHg
DOPE Pneumonic D - Dislodgement - check the tube! O - Obstruction - suction P - Pneumothorax - check lung sounds E - Equipment - check the vent
IntubationIntubation
Intubation Trick Attach the ETCO2 detector to the ET-tube
prior to attempting intubation. You should see some waveforms as you
get close to the vocal cords with the spontaneously breathing patient.
May be useful if CPR is in progress as well.
Intubation Trick Attach the ETCO2 detector to the ET-tube
prior to attempting intubation. You should see some waveforms as you
get close to the vocal cords with the spontaneously breathing patient.
May be useful if CPR is in progress as well.
IntubationIntubation
Capnography can be used with supraglottic airway devices
Paramedics should document the use of capnography This benefits the paramedic!!! There is no dispute when a waveform is
present.
Capnography can be used with supraglottic airway devices
Paramedics should document the use of capnography This benefits the paramedic!!! There is no dispute when a waveform is
present.
IntubationIntubation
IntubationIntubation
Waveform vs. Colorimetric Capnography In colorimetric capnography a filter attached
to an ET tube changes color from purple to yellow when it detects carbon dioxide It is not continuous has no waveform no number no alarms is easily contaminated is hard to read in dark can give false readings.
Waveform vs. Colorimetric Capnography In colorimetric capnography a filter attached
to an ET tube changes color from purple to yellow when it detects carbon dioxide It is not continuous has no waveform no number no alarms is easily contaminated is hard to read in dark can give false readings.
Monitoring VentilationMonitoring Ventilation
Hyperventilation decreases ETCO2
Other causes of decreased ETCO2 Cardiac arrest Decreased cardiac output Hypotension Cold Severe pulmonary edema
Hyperventilation decreases ETCO2
Other causes of decreased ETCO2 Cardiac arrest Decreased cardiac output Hypotension Cold Severe pulmonary edema
Monitoring VentilationMonitoring Ventilation
Hyperventilation
Hypothermia
Hyperventilation
Hypothermia
Ventilation
Metabolism
Monitoring VentilationMonitoring Ventilation
Ventilation equals tidal volume x respiratory rate.
A patient taking in a large tidal volume can still hyperventilate with a normal respiratory rate just as a person with a small tidal volume can hypoventilate with a normal respiratory rate.
Ventilation equals tidal volume x respiratory rate.
A patient taking in a large tidal volume can still hyperventilate with a normal respiratory rate just as a person with a small tidal volume can hypoventilate with a normal respiratory rate.
Monitoring VentilationMonitoring Ventilation
Hypoventilation causes an increased ETCO2 (hypocapnia)
Other causes of increased ETCO2: Increased cardiac output Fever Pain severe difficulty breathing depressed respirations chronic hypercapnia
Hypoventilation causes an increased ETCO2 (hypocapnia)
Other causes of increased ETCO2: Increased cardiac output Fever Pain severe difficulty breathing depressed respirations chronic hypercapnia
Monitoring VentilationMonitoring Ventilation
Hypoventilation
Malignant Hyperthermia
Hypoventilation
Malignant Hyperthermia
Ventilation
Metabolism
Monitoring VentilationMonitoring Ventilation
Monitor The Trend! A steadily rising ETCO2 (as the patient
begins to hypoventilate) can help a paramedic anticipate when a patient may soon require assisted ventilations or intubation.
Monitor The Trend! A steadily rising ETCO2 (as the patient
begins to hypoventilate) can help a paramedic anticipate when a patient may soon require assisted ventilations or intubation.
Monitoring VentilationMonitoring Ventilation
Capnography should be used to monitor any patients receiving pain management or sedation (enough to alter their mental status) for evidence of hypoventilation and/or apnea.
Capnography should be used to monitor any patients receiving pain management or sedation (enough to alter their mental status) for evidence of hypoventilation and/or apnea.
Sign ofOverdose
Monitoring VentilationMonitoring Ventilation
Capnography is also essential in sedated, intubated patients. A small notch in the wave form indicates the patient is beginning to arouse from sedation, starting to breathe on their own, and will need additional medication to prevent them from "bucking" the tube. Called “curare cleft”
Capnography is also essential in sedated, intubated patients. A small notch in the wave form indicates the patient is beginning to arouse from sedation, starting to breathe on their own, and will need additional medication to prevent them from "bucking" the tube. Called “curare cleft”
Monitoring VentilationMonitoring Ventilation
“Curare cleft”“Curare cleft”
Monitoring VentilationMonitoring Ventilation
“Curare cleft”“Curare cleft”
40
0
A
B C
D A
B C
D
Monitoring VentilationMonitoring Ventilation
End-tidal CO2 monitoring on non-intubated patients is an excellent way to assess the severity of Asthma/COPD, and the effectiveness of treatment. Bronchospasm will produce a characteristic “Shark fin” wave form, as the patient has to struggle to exhale
End-tidal CO2 monitoring on non-intubated patients is an excellent way to assess the severity of Asthma/COPD, and the effectiveness of treatment. Bronchospasm will produce a characteristic “Shark fin” wave form, as the patient has to struggle to exhale
Monitoring VentilationMonitoring Ventilation
Bronchospasm “Shark Fin”Bronchospasm “Shark Fin”
Monitoring VentilationMonitoring Ventilation
Bronchospasm “Shark Fin”Bronchospasm “Shark Fin”
40
0
A
B
Monitoring VentilationMonitoring Ventilation
Drug Overdoses Some EMS systems permit medics to
administer Narcan only to unresponsive patients with suspected opiate overdoses with respiratory rates less than 10.
Drug Overdoses Some EMS systems permit medics to
administer Narcan only to unresponsive patients with suspected opiate overdoses with respiratory rates less than 10.
Monitoring VentilationMonitoring Ventilation
Emphysema Down-sloping due to destruction of alveolar
capillary membranes & reduced gas exchange
Emphysema Down-sloping due to destruction of alveolar
capillary membranes & reduced gas exchange
Monitoring VentilationMonitoring Ventilation
Rebreathing Sometimes called “stacking breaths” Troubleshoot mechanical ventilator
Rebreathing Sometimes called “stacking breaths” Troubleshoot mechanical ventilator
Monitoring CirculationMonitoring Circulation
Cardiac Arrest A higher ETCO2 reading indicates a higher quality
of CPR. Pulseless patients generally present with ETCO2
readings from 10 to 15 mmHg A spike in ETCO2 indicates return of spontaneous
circulation (ROSC).
*ALWAYS SUSPECT A POSSIBLE PERFUSABLE RHYTHM WITH ELEVATED ETCO2 LEVELS!
Cardiac Arrest A higher ETCO2 reading indicates a higher quality
of CPR. Pulseless patients generally present with ETCO2
readings from 10 to 15 mmHg A spike in ETCO2 indicates return of spontaneous
circulation (ROSC).
*ALWAYS SUSPECT A POSSIBLE PERFUSABLE RHYTHM WITH ELEVATED ETCO2 LEVELS!
Monitoring CirculationMonitoring Circulation
With cardiac arrest we have a circulatory compromise
With cardiac arrest we have a circulatory compromise
Circulation Ventilation
Metabolism
Monitoring CirculationMonitoring Circulation
Monitoring CirculationMonitoring Circulation
The O2 in the cells is metabolized, and CO2 is present, but stagnant in the body.
The return of circulation causes a washout of this CO2; which shows up as a spike in ETCO2 levels.
The O2 in the cells is metabolized, and CO2 is present, but stagnant in the body.
The return of circulation causes a washout of this CO2; which shows up as a spike in ETCO2 levels.CO2
40
0
Monitoring CirculationMonitoring Circulation
A sudden drop in ETCO2 may be an indication to check for a pulse.
A sudden drop in ETCO2 may be an indication to check for a pulse.
CO2
40
0
Monitoring CirculationMonitoring Circulation
"An end-tidal carbon dioxide level of 10 mmHg or less measured 20 minutes after the initiation of advanced cardiac life support accurately predicts death in patients with cardiac arrest associated with electrical activity but no pulse. Cardiopulmonary resuscitation may reasonably be terminated in such patients.” -Levine R, End-tidal Carbon Dioxide and Outcome of Out-of-Hospital Cardiac Arrest, New England Journal of Medicine, July 1997
"An end-tidal carbon dioxide level of 10 mmHg or less measured 20 minutes after the initiation of advanced cardiac life support accurately predicts death in patients with cardiac arrest associated with electrical activity but no pulse. Cardiopulmonary resuscitation may reasonably be terminated in such patients.” -Levine R, End-tidal Carbon Dioxide and Outcome of Out-of-Hospital Cardiac Arrest, New England Journal of Medicine, July 1997
Monitoring CirculationMonitoring Circulation
“No patient who had an end-tidal carbon dioxide of level of less than 10 mm Hg survived. Conversely, in all 35 patients in whom spontaneous circulation was restored, end-tidal carbon dioxide rose to at least 18 mm Hg before the clinically detectable return of vital signs....The difference between survivors and nonsurvivors in 20 minute end-tidal carbon dioxide levels is dramatic and obvious.”
-ibid.
“No patient who had an end-tidal carbon dioxide of level of less than 10 mm Hg survived. Conversely, in all 35 patients in whom spontaneous circulation was restored, end-tidal carbon dioxide rose to at least 18 mm Hg before the clinically detectable return of vital signs....The difference between survivors and nonsurvivors in 20 minute end-tidal carbon dioxide levels is dramatic and obvious.”
-ibid.
Monitoring CirculationMonitoring Circulation
Asphyxic vs. Cardiac Arrest Cardiac Arrest caused by asphyxia shows
a higher ETCO2 reading initially on the monitor.
This number should come down within the first minute of CPR.
Asphyxic vs. Cardiac Arrest Cardiac Arrest caused by asphyxia shows
a higher ETCO2 reading initially on the monitor.
This number should come down within the first minute of CPR.
Monitoring CirculationMonitoring Circulation
End tidal CO2 monitoring can provide an early warning sign of shock.
A patient with a sudden drop in cardiac output will show a drop in ETCO2 numbers that may be regardless of any change in breathing.
This has implications for trauma patients, cardiac patients - any patient at risk for shock.
End tidal CO2 monitoring can provide an early warning sign of shock.
A patient with a sudden drop in cardiac output will show a drop in ETCO2 numbers that may be regardless of any change in breathing.
This has implications for trauma patients, cardiac patients - any patient at risk for shock.
Monitoring CirculationMonitoring Circulation
Pulmonary Embolus Pulmonary embolus will cause an increase
in the dead space in the lungs decreasing the alveoli available to offload carbon dioxide.
The ETCO2 will go down.
Pulmonary Embolus Pulmonary embolus will cause an increase
in the dead space in the lungs decreasing the alveoli available to offload carbon dioxide.
The ETCO2 will go down.
Monitoring MetabolismMonitoring Metabolism
DKA - Patients with DKA hyperventilate to lessen their acidosis.
The hyperventilation causes their PACO2 to go down. Kussmal’s respirations are rapid & deep.
DKA - Patients with DKA hyperventilate to lessen their acidosis.
The hyperventilation causes their PACO2 to go down. Kussmal’s respirations are rapid & deep.
Monitoring MetabolismMonitoring Metabolism
Water + Carbon dioxide = Carbonic Acid Carbonic Acid = Hydrogen + Bicarbonate
Water + Carbon dioxide = Carbonic Acid Carbonic Acid = Hydrogen + Bicarbonate
H2O + CO2 H2CO3 H + HCO3
Monitoring MetabolismMonitoring Metabolism
Hyperthermia Metabolism is on overdrive in fever, which
may cause ETCO2 to rise. Observing this phenomena can be live-saving in patients with malignant hyperthermia, a rare side effect of RSI (Rapid Sequence Induction).
Hyperthermia Metabolism is on overdrive in fever, which
may cause ETCO2 to rise. Observing this phenomena can be live-saving in patients with malignant hyperthermia, a rare side effect of RSI (Rapid Sequence Induction).
Monitoring MetabolismMonitoring Metabolism
Sepsis ETCO2: 31-34 = Increased survivability ETCO2: Less than 30 = Increased morbidity
End-Tidal Carbon Dioxide Levels Are Associated with Mortality In Emergency Department Patients with Suspected Sepsis
-Hunter CL, et al. Orlando Regional Medical Center, Orlando, FL
Sepsis ETCO2: 31-34 = Increased survivability ETCO2: Less than 30 = Increased morbidity
End-Tidal Carbon Dioxide Levels Are Associated with Mortality In Emergency Department Patients with Suspected Sepsis
-Hunter CL, et al. Orlando Regional Medical Center, Orlando, FL
Abnormal ETCO2Abnormal ETCO2
Increased ETCO2
Decreased ETCO2
Ventilation HypoventilationBronchoconstrictionDrug overdose
HyperventilationDislodged ET-Tube
Circulation Good CPRReturn of pulse (ROSC)Increased cardiac output
ApneaCardiac ArrestPulmonary EdemaPulmonary Embolism
Metabolism Fever/HyperthermiaSeizureBurnsMuscle use
DKASepsisHypothermia
ScenariosScenarios
You just intubated a patient that had severe dyspnea using RSI successfully BP: 142/90 HR: 140 RR: Assisted BGL: 170
You just intubated a patient that had severe dyspnea using RSI successfully BP: 142/90 HR: 140 RR: Assisted BGL: 170
40
0
ETCO2: 55
Malignant Hyperthermia
ScenariosScenarios
You have a 88 y/o male who has fallen on the ground, and is currently unconscious. BP: 114/70 HR: 50 RR: 10 BGL: 90
You have a 88 y/o male who has fallen on the ground, and is currently unconscious. BP: 114/70 HR: 50 RR: 10 BGL: 90
40
0
ETCO2: 25
Hypothermia
ScenariosScenarios
You have a 75 y/o female patient with altered mental status BP: 100/40 HR: 130 RR: 30 BGL: 100
You have a 75 y/o female patient with altered mental status BP: 100/40 HR: 130 RR: 30 BGL: 100
40
0
ETCO2: 25
SEPSIS
The EndThe End
This concludes this course on capnography.
Questions or feedback Email [email protected]
This concludes this course on capnography.
Questions or feedback Email [email protected]