NewAge Cast Iron Soil Pipe Systems

NewAge manufactures both major categories of Cast Iron Soil Pipe Systems:

1. No-Hub (Hubless) ASTM A888 & CISPI 301

2. Hub & Spigot (Service Weight) ASTM A74

Page 3: New Age Presentation final 2014

The Complete NewAge System

Standard 2 Band Couplings

Heavy Duty Couplings

Service Weight Gaskets

Page 4: New Age Presentation final 2014

Who are we?• Company was established in 2005

• Management with over 60 years combined experience with Cast Iron Soil Pipe.

200,000 sq/ft facility

All products stored under covered warehouse

Ensures protection from elements

Page 5: New Age Presentation final 2014

Indoor Product Storage

Pipe is stored in vertical racks capable of holding 5 truckloads each

Fittings stored in racks with overstock above.

Page 6: New Age Presentation final 2014

National Distribution

Page 7: New Age Presentation final 2014

Raw Materials

• We utilize over 95% Virgin Pig Iron

– Resulting in a higher composition of metal

• Consistent snap cuts with scissor and ratchet type cast iron snap cutters

• Can cut pieces as small as a ½”

• Uniform pipe cuts utilizing chop saw

Page 8: New Age Presentation final 2014

Manufacturing to Perfection

•Honed (Clean) Interior of Each Pipe

– Resulting in better flow characteristics

•Hydrostatic Testing of Each Pipe

– 5 PSI Water Test Before the Coating Process

•Spray Coated for Consistent Coverage

– Easier Installation resulting in Flush Coupling Seat

Page 9: New Age Presentation final 2014

Quality Systems

Levels of Quality Control (QC)

-All NewAge Foundries are ISO 9001 Approved

-Foundry QC at time of manufacturing

-NewAge QC with our on-site Foundry Inspectors

-NewAge QC Upon Receiving Goods

-NewAge QC Before Shipment of Goods

-UPC / IAPMO QC audits for compliance four times per year

-NSF International as an additional 3rd party QC

-ICC Evaluation Services as additional 3rd party QC

Page 10: New Age Presentation final 2014

NewAge Metallurgical Lab

Page 11: New Age Presentation final 2014

Material Test Reports

• Radioactivity Screening

• Chemical Composition

• Tensile Strength

• Dimensional Check

• MSDS for Coatings

All test reports maintained for a minimum of 7 years for full traceability

Page 12: New Age Presentation final 2014

Typical Job Site

Page 13: New Age Presentation final 2014

Fittings Packaging

Fitting crates are organized, packaged & labeled by floor, section or campus which minimizes project labor costs.

Page 14: New Age Presentation final 2014

Fittings Packaging

Fitting crates are organized and labeled with all products inside the crates for ease of material handling to

maximize labor efficiencies.

Page 15: New Age Presentation final 2014

Pipe Packaging

Solid Platform Base with End and Side Fork Lift Access

All Pipe Independently Strapped using Poly Banding

Vertical and Horizontal separation to protect from rust lines

Pipe is bagged prior to leaving the foundry for further protection

Page 16: New Age Presentation final 2014

Completed Job Sampling

Commercial-Kyle Seaton Hospital, Kyle, TX-Hualapai Medical Center, Hualapai, AZ-Matagorda General Hospital, Bay City, TX-Odessa Women and Children Hospital, Odessa, TX-BRAC-FHS Medical Facility, Fort Sam Houston, TX-Sol-Air LA, CA-The Summit, LA CA-Lancaster Hospital, Lancaster CA-Colorado Convention Center, Denver CO-Colorado Rapids Stadium, Denver CO-Hyatt Regency Convention Center Hotel, San Antonio, TX-Palace Inn, Ann Arbor MI-Edgemont Hotel, Steam Boat Springs, CO-Renaissance Hotel, Colorado Springs, CO-Barnes and Noble, Sugarland, TX-San Jacinto, Austin, TX-Bexar County Courthouse, San Antonio

Educational Institutions-Cal State Poly, Pomona CA - New Buildings and residences-Westminster High School, Westminster, CO-Western State College, Gunnison, CO-SDC School, Moscoa, CO-South Cobb High School, Austell, GA-Eastside Elementary School, Marietta, GA

Correction Facilities-Guilford County Jail, Greensboro, NC-Wake County Jail, Raleigh, NC-Charlotte County Jail, Charlotte, NC-Travis County Correctional Facility, Austin, TX-Colorado State Prison, Canon City, CO

Multi-Family-Mosaic, Houston, TX-Gables, Houston, TX-Riviera Nursing Home, Coral gables, FL-Allegro, San Diego CA - 430 units, 3 stories-Archstone, San Diego CA - 736 units, 3 stories-Alteza Condos, San Antonio, TX-Bonita, Newport Beach CA - 513 units, 4 stories-Brittany, Irvine CA - 530 units, 3 stories-Crescent Walk, Los Angeles CA - 122 units, 4 story over 2 parking-Jefferson, San Diego CA - 693 units, 3 stories-Las Palmas, Irvine CA - 736 units, 3 stories-One Park Place, Irvine CA - 611 units, 4 story over 2 parking-Avalon at Wilshire, Los Angeles CA - 123 units, 4 story over 3 parking-North Hollywood Commons, North Hollywood CA-Wilshire Court, Los Angeles CA - 201 units, 5 story over 3 parking-Whispering Ridge Apartments, Omaha, NE

Page 17: New Age Presentation final 2014

Welcome to the NewAge of Epoxy!!

Page 18: New Age Presentation final 2014

Excessive Corrosion

- Hospitals / Labs

- Food Processing

- Hot Water over 180º

- Soda Machines

- Bars / Kitchens

- Cleaning Chemicals

- Waterless / HEU

- Maritime

Excessive Corrosion Effects DWV Systems

The Epoxy System is Designed for:

Page 19: New Age Presentation final 2014

MIC: A Form of Excessive Corrosion

Microbiologically Influenced CorrosionWhat causes MIC?

MIC is caused by bacterial microbes in combination with four other environmental conditions: metals (host location), nutrients, water, and oxygen (although some types of bacteria need only very small amounts of oxygen). These bacteria are ubiquitous in the environment and piping materials. When all of these environmental conditions are present, then microbial growth will occur.

What happens if MIC is present in pipes?

As MIC bacteria grows, consumption of the metal pipe occurs and sometimes tubercles are formed. Pitting is a likely effect and the walls of the pipe may be penetrated but the flow characteristics of the pipes are degraded.

Page 20: New Age Presentation final 2014

MIC Corroded Pipe from Phoenix and Tampa

Page 21: New Age Presentation final 2014

Challenge: Re-Pipe due to Corrosion

Re-pipe: Challenge for owners to operate their facility:

• Down time of their building / facility due to corrosion and resulting in non-functioning sanitary systems.

• Cost associated with replacement and re-commissioning of the system.

Page 22: New Age Presentation final 2014

Coating Requirements by Code

• The current Cast Iron Soil Pipe Standards have no requirements as to what can be used to coat pipe/fittings.

• The standard only requires

– “The pipe and fittings shall be uniformly coated with a material suitable for the purpose, that is adherent, not brittle, and without tendency to scale.”

Page 23: New Age Presentation final 2014

The Solution: NewAge Epoxy

- Pipe and fittings conforming to ASTM A 888 with Epoxy Coating

- Coating meets EN 877 Standard – British, European and Australian standard that requires all commercial application DWV be epoxy coated.

- Internal and external layer of epoxy coating

Page 24: New Age Presentation final 2014

Coating Approval by UPC

Page 25: New Age Presentation final 2014

EN 877 Testing: Epoxy Coating

Resistance to Salt Spray Test Length: 350 hours Test Procedure: Immerse in Salt Spray

Resistance to Waste Water Test Length: 30 days Test Procedure: immersed conditions at 73°F

Chemical Resistance Test Length: 30 days immersedTest Procedure: 1st Sample: a solution of sulfuric acid at 2pH held at 73°F. 2nd Sample: solution of sodium hydroxide at 12pH held at 73°F

Coating ThicknessTest Procedure: Pipe: mean value of at least ten measurements. Fitting: mean value of at least five measurements spread over the surface of the fitting.

Page 26: New Age Presentation final 2014

EN 877 Testing: Epoxy Coating

AdhesionTest Procedure: Section 5.9 inch long cut from a coated pipe or fitting. Number of cuts: 6, Spacing of the cuts: 0.08 inch

Resistance to Hot WaterTest Length: 24 hoursTest Procedure: Immersed for in a water bath held at 203°F.

Resistance to Temperature CyclingTest Length: 1500 cycles of passage of hot and cold water. Test Procedure / Schedule: a) Eight gallons of water at a temperature of 203°F over a period of 1 minc) Eight gallons of water at a temperature of 40°F over a period of 1 min

Page 27: New Age Presentation final 2014

Installation of NewAge Epoxy

The install of NewAge Epoxy Pipe is no different then the standard CISP system. There is no additional cost for the installation of NewAge Epoxy on standard DWV projects.

Joined with Regular, Heavy Duty or Extra Heavy Duty no hub coupling

Page 28: New Age Presentation final 2014

Cost Difference of Epoxy

There is little cost difference between standard cast iron and NewAge’s premier epoxy coated cast iron System.

NewAge Epoxy adds tremendous value for your Clients.

10 Year Warranty!!

NewAge epoxy coating protects the entire system for the Life of the Building.