8 Problems - 1 Solution

Common Problems The New Inferno Steam Hose

1. Inner subject to popcorning superior gas-tight and extruded inner

2. Outer layer blowing Outer layer extruded and pin-pricked

3. Metal braid rusting 2 layers of brass laminated steel braid

4. Hose markings unclear Clear spiral marking

5. Premature aging New heat and weather resistant cover

6. Hose kinking Double braid prevents kinking

7. Static charge build up Electrically conductive to allow discharge

8. Fittings leaking DINBO Couplings 100% leak-proof to EN ISO 14423

ERIKS Hose Technology - www.eriks.co.uk

1. Problem: Popcorning

ERIKS Hose Technology - www.eriks.co.uk

Problem: Popcorning

The expansion factor of a water

Droplet into steam.

ERIKS Hose Technology - www.eriks.co.uk

Solution

A mirror smooth, homogeneous, seamless extruded tube made of

a new butyl rubber with a very high gas density

– EPDM 1,0 cc/sec/m2

– Butyl 0,3 cc/sec/m2

ERIKS Hose Technology - www.eriks.co.uk

2. Problem: Outer layer blowing

ERIKS Hose Technology - www.eriks.co.uk

Solution

Pinpricking

Extruded outer

ERIKS Hose Technology - www.eriks.co.uk

3. Problem: Rusting braid

ERIKS Hose Technology - www.eriks.co.uk

Solution

Double braided steel inlays are brass-coated for optimum

corrosion resistance

Stainless Steel inlays also available

ERIKS Hose Technology - www.eriks.co.uk

4. Problem: Hose markings unclear

ERIKS Hose Technology - www.eriks.co.uk

Solution: Clear spiral marking

ERIKS Hose Technology - www.eriks.co.uk

5. Problem: Premature aging, Hardening

ERIKS Hose Technology - www.eriks.co.uk

Solution: extruded EPDM outer

• UV Resistant

• Wear Resistant

ERIKS Hose Technology - www.eriks.co.uk

6. Problem: Kinking of the hose

ERIKS Hose Technology - www.eriks.co.uk

Solution: Two layers of braid

ERIKS Hose Technology - www.eriks.co.uk

7. Problem: Static Generation

Static is created by the collision of the water and the vapour

molecules in the steam. This friction creates a static electricity

charge

ERIKS Hose Technology - www.eriks.co.uk

Solution

The BR8 Inferno steam hose is electrically conductive when

measured between the fittings (< 102 Ω )

The rubber compound has a resistance of less than 106 Ω

ERIKS Hose Technology - www.eriks.co.uk

8. Problem: Fittings leaking

ERIKS Hose Technology - www.eriks.co.uk

Solution: EN14423 Steam clamps

ERIKS Hose Technology - www.eriks.co.uk

The Advantage of DIN clamps

ERIKS Hose Technology - www.eriks.co.uk

Certification