36
Matrx ® Anaesthesia

Midmark Matrx® Veterinary Anaesthesia range

Embed Size (px)

Citation preview

Page 1: Midmark Matrx® Veterinary Anaesthesia range

Matrx® Anaesthesia

Page 2: Midmark Matrx® Veterinary Anaesthesia range

Better Patient Care. Better Business.

Since 1964 more veterinary professionals and universities throughout the world have placed their trust in anaesthesia technology, pioneered by Fraser Sweatman and now found exclusively in every Matrx® anaesthesia machine.

Page 3: Midmark Matrx® Veterinary Anaesthesia range

Matrx®, formerly known by the name, Fraser Sweatman, started back in the mid 1960’s. Throughout the years there has been company merges, buyouts and name changes but the general assembly has stayed the same. Only a few changes occurred for added safety or convenience e.g., Occlusion valve, negative pressure relief valve and flip levers.

In 2004, Midmark purchased the dental and veterinary divisions of Matrx®, adding the veterinary/animal health sector. Then in 2009, manufacturing was brought to Versailles, OH where 50+ years of manufacturing experience goes into every Matrx® anaesthesia machine.

Matrx® History

Page 4: Midmark Matrx® Veterinary Anaesthesia range

Matrx® Range

VMS54”H x 12”W

VMS Plus57”H x 22” W x 12 D

VME Tabletop14”H x 13.5” W x 8.5” D

VML

VMS mounted on a Canis Major Wet Table

Page 5: Midmark Matrx® Veterinary Anaesthesia range

Matrx® VMS • Chrome construction• 1500cc CO2 absorber with

“Quick Release” lever • Accepts pre-pack canister or

loose absorbent• Accepts Matrx VIP 3000® and

TEC 3 vaporizers• Vaporizer mounting kit, 1L & 2L breathing bags • Circle and T Piece circuits• Optional shelves available• Vaporizer not included

Page 6: Midmark Matrx® Veterinary Anaesthesia range

Matrx® VME • Accepts Matrx VIP 3000® and TEC

3 vaporizers• Includes vaporizer mounting kit, 1

and 2 liter breathing bags and15mm and 22mm breathing circuits

• Optional shelves available• Portable stand with 5-leg spider

base allows easy mobility• Also available in table top / wall

mounted versions

Page 7: Midmark Matrx® Veterinary Anaesthesia range

Matrx® VML • Dual view oxygen flowmeter – glass tube

with a fused scales reading from 1 to 10 LPM – quickly switch from standard to magnified view at the touch of a finger

• Easy-to-view inhalation/exhalation valves allow easy monitoring of respiration for patient safety

• Oxygen flush• 5200 cc CO2 absorber• Scavenging/adjustable pressure limiting

valve• 30 litre breathing bag• 2" (5 cm) diameter breathing circuit• Accepts VIP 3000® and TEC 3 vaporizers

(mounting kit included but not vaporizer)

Page 8: Midmark Matrx® Veterinary Anaesthesia range

Matrx® VIP Vaporizers

• Automatic flow rate and temperature compensation

• Large, easy-to-read dial• Integrated safety lock to prevent

unintentional engagement• Large sight glass with at-a-glance

liquid level monitoring• Choice of agent-specific models:

sevoflurane / isoflurane• Well-fill & key-fill models

Page 9: Midmark Matrx® Veterinary Anaesthesia range

Sodasorb® & Sodasorb LF

• Permanent high contrast colour change

• Eliminates compound A / CO2 / heat generation

• Unique formulation makes use of Anaesthetic Agent more efficient

• Minimal resistance to gas flow

• Unique pellet shape reduces caustic dust

• Proven safety record

• Convenient pre-packed cartridges & Refill bags & 5 gallon pail (18.15kg)

Page 10: Midmark Matrx® Veterinary Anaesthesia range

Better Patient Care. Better Business.

Matrx® Theory of Operation

Page 11: Midmark Matrx® Veterinary Anaesthesia range

VMS Diagram

Page 12: Midmark Matrx® Veterinary Anaesthesia range

Theory of Operation

Page 13: Midmark Matrx® Veterinary Anaesthesia range

Oxygen Flush

Page 14: Midmark Matrx® Veterinary Anaesthesia range

The APL ValveThe APL Valve (adjustable pressure limiting) or Pop-Off valve, controls the pressure in the system and the patients lungs.Fully open, the APL valve maintains a pressure of 1-3cm/H2O. When the pressure in the system exceeds the 1-3cm/H2O, the valve opens and gas escapes.

Open APL valve, pressure in the system is under 1-3CM/H2O

Open APL valve, pressure in the system is over 1-3cm/H2O allowing gas to escape.

Page 15: Midmark Matrx® Veterinary Anaesthesia range

The Occlusion ValveThe Matrx® Occlusion valve allows the anaesthetist to simply and quickly close the breathing circuit to allow a bagged breath to the patient. The safety relief feature prevents an unsafe pressure buildup in the anaesthetic machine and patient. If pressure exceeds 25-30cm/H2O, the valve opens, releasing the pressure out the APL valve.

Page 16: Midmark Matrx® Veterinary Anaesthesia range

This safety valve allows the patient to breath if the oxygen supply runs out or is shut off. The flexible diaphragm lets air in if the pressure inside the machine during inhalation becomes lower than the pressure outside.

Negative Pressure Relief Valve

Page 17: Midmark Matrx® Veterinary Anaesthesia range

Negative Pressure Relief Valve

Page 18: Midmark Matrx® Veterinary Anaesthesia range

Better Patient Care. Better Business.

Matrx® Acccessories

Page 19: Midmark Matrx® Veterinary Anaesthesia range

LaryngoscopesMatrx® Laryngoscope Blades are precision manufactured using durable 300 series stainless steel for years of dependable use.

• Choice of curved Macintosh or straight Miller styles

• Extended curved tip on Miller blades to improve lifting of epiglottis

• Gold-plated lamp contacts permit autoclaving up to 130 degrees Celsius without corrosion or damage to illumination circuit

• Wide selection of sizes fits all handles• Preinstalled lamps are easily replaceable

without tools

Page 20: Midmark Matrx® Veterinary Anaesthesia range

Endotracheal Tubes

• High-compliance cuff lies close to tube

• Design helps prepare for intubations

• Thin, large diameter cuff conforms to uneven tracheal surfaces

• Un-cuffed tubes are also available

• Sizes 2.0 – 10.mm

Page 21: Midmark Matrx® Veterinary Anaesthesia range

Breathing Circuits

Re-breathing bags:<7kg 500ml7-14kg 1L14-27kg 2L27-45kg 3L45kg+ 5L<250kg 15L>250kg 30L

• Circle breathing circuit (rebreathing)

• Unilimb circuit (rebreathing)

• Ayres T Piece (fresh gas flow)

Page 22: Midmark Matrx® Veterinary Anaesthesia range

Masks and Induction Boxes

FACEMASKS:• Suitable for canine, feline or exotic pets• 15mm connector• Clear cone for full visualization• Highly flexible, replaceable rubber diaphragm for a leak-free fit

SMALL ANIMAL INDUCTION CHAMBERS:• four sizes:

• small dogs• cats• birds• mice and other small patients.

Page 23: Midmark Matrx® Veterinary Anaesthesia range

Better Patient Care. Better Business.

Matrx®

Total Solutions

Page 24: Midmark Matrx® Veterinary Anaesthesia range

Scavenging• Designed to meet current ASTM

and ANSI standards• Available in post mount or wall

mount configurations• Quiet operation• Can be used with a ventilator or

oxygenator• Easy to install, compact design

with few parts• Standard 19mm inlet connection• Power on/off switch with

indicator light• Low voltage (12V DC) operation

Page 25: Midmark Matrx® Veterinary Anaesthesia range

Ventilator WHY VENTILATE?

• Replaces the breathing bag; frees nurse to assist in other procedures

• Precise control of anaesthetic allows lower levels of anaesthesia for more responsive patients / more economical operation,

• Blood CO2 and pH levels are maintained closer to normal

• Patients with compromised or questionable lung function

Page 26: Midmark Matrx® Veterinary Anaesthesia range

Ventilator MATRX® MODEL 3000

• Interchangeable bellows; from 1 kg to 300 kg – no tools required

• Maximum working pressure limit adjustable from 10-60 cm H2O

• Dual airway pressure alarms signal any breath exceeding preset maximum or minimum

• Optional low supply gas alarm signals supply gas pressure below 35 psi

• Respiratory rates from 6-40 breaths per minute at inspiratory flow rates from 0-100 litres per min

• Tidal volumes from 20 -3,000 cc• Built-in scavenging port

Page 27: Midmark Matrx® Veterinary Anaesthesia range

Better Patient Care. Better Business.

Matrx® Maintenance and Troubleshooting

Page 28: Midmark Matrx® Veterinary Anaesthesia range

Maintenance Kits

• Recommend changing rubber O rings and seals every 2 years

• Save money buying Maintenance Kit rather than separate items

• Upgrade old machines with thumb nut on the absorber canister to convenient quick releases

Page 29: Midmark Matrx® Veterinary Anaesthesia range

Pressure Gauge (Manometer)The pressure gauge or Manometer allows you to monitor pressure inside the anaesthetic circuit / macine

It is especially useful for leak testing the anaesthesia machine and for monitoring the system pressure during assisted ventilation

Page 30: Midmark Matrx® Veterinary Anaesthesia range

Testing the APL valve

Page 31: Midmark Matrx® Veterinary Anaesthesia range

Testing the inhalation & exhalation valve

Page 32: Midmark Matrx® Veterinary Anaesthesia range

Leak Test

Page 33: Midmark Matrx® Veterinary Anaesthesia range

Leak TestOther common areas of leakage:

• Reservoir bag – replace if necessary

• Breathing circuit – replace if necessary

• Vaporiser fittings – verify fittings and attachments

• Absorber canister – verify seated properly, check gaskets

• Safety Valves – remove valve and obstruct opening to determine if leaking or not – check o ring

• O Rings – check for damage and replace if necessary

Page 34: Midmark Matrx® Veterinary Anaesthesia range

Cleaning

Page 35: Midmark Matrx® Veterinary Anaesthesia range

Scheduled MaintenanceInterval Inspection /

ServiceDescription

Before every surgery Inspect Check machine connections and rubber parts for looseness, damage or wear – replace as necessary

Before every surgery Leak Test Perform leak test

Daily Clean Daily cleaning

Weekly Change Sodasorb

Follow manufacturer’s instructions for proper use of CO2 absorbents (rec. every 2 weeks)

Annually Service Vaporizer

Service and calibrate vaporiser

Every 2 years Replacement Replace components found in maintenance kits (o rings, gaskets, valve disks, breathing circuit, etc.)

Page 36: Midmark Matrx® Veterinary Anaesthesia range

Thank you for watching the Midmark Matrx® Anaesthesia presentation

Over fifty years of quality manufacturing experience goes into every Matrx® anaesthesia machines. The all metal construction in combination with high quality rubber seals and hoses provide a durable, pressurized system that requires little maintenance. The Matrx® VMS and VMS Plus anaesthesia machines have been a long-standing favourite with veterinary professionals for the high quality, safety and ease of use.

The Occlusion Valve, Negative Pressure Relief Valve, included with the VMS and VMS Plus are added for safety and peace of mind. The dome style inhalation/exhalation valves allows for easy monitoring of respiration and the quick release levers for easy absorbent replacement.

The theory of operation, anaesthesia machine training, and trouble shooting advice available on-line:

http://www.midmarkanimalhealth.com/training/matrx-anesthesia-training

If you would like to enquire about any of the Midmark Matrx® anaesthesia equipment featured in this presentation, please do get in touch on +44(0)1252 360 940 or alternatively e-mail us at

[email protected]