10
POUmon Test pour lArrêt Cardiaque POUTAC A Lyazidi, RL Cordioli, L Suppan, JC Richard pour le groupe de recherche GRHUG Soins Intensifs Hôpitaux Universitaires de Genève

The CPR TestLung T

Embed Size (px)

Citation preview

Page 1: The CPR TestLung T

POUmon Test pour l’Arrêt Cardiaque

POUTAC

A Lyazidi, RL Cordioli, L Suppan, JC Richard

pour le groupe de recherche GRHUG

Soins Intensifs

Hôpitaux Universitaires de Genève

Page 2: The CPR TestLung T
Page 3: The CPR TestLung T

ml

a

bc

d

e f

a. Ressort

b. Soufflet

c. Seringue

d. Prise de pression

dans le soufflet

e. Entré d’air

f. Stylet et Papier

millimétrique

f

mlml

c

e

a

b

c

Lung model designed for CPR (manual or automatic)

In Vitro study

Pressure transmitted into the

thoracic compartment

Change in lung volume: Vt and FRC

Page 4: The CPR TestLung T

Valorisation :Etude de marché

R & D

- Un produit pour la recherche :

Clients potentiels:- Centres de recherche- Industries (tester les machines de massage cardiaque et respiratoire)

- Un produit pour la formation:

Réanimation premiers secours

Clients potentiels:- Centres hospitaliers- Centres premiers secours- Piscines- Ecoles- ….

Page 5: The CPR TestLung T

Academic & administration HUG, Unitec (O. Deloche/A.Weber)

Scientific teamCESU/SIMUL : R.Cordioli, A. Lyazidi, L. Brochard and JC Richard

HUG SIMUL HUG: Pr. G Savoldelli - Cardiomobile : L. Suppan -

Annecy General Hospital CESU 74 : G. Gheno, D. Savary

INSERM UMR 955 Eq13 : D Isabey, B Louis - REVA European

network on mechanical ventilation

Industry, patent & marketingSCCOPI Engineering Sàrl : M. Botkine, D. Milone, P. Chiuppi,

D. Freiburghaus: prototype, product design & development,

software development, industrialization, distribution &

communication. - Reuteler (patent)

Partnerships & international collaborationsJoining international project Life Priority

Worldwide scientific Collaboration (CH, F, B, CAN)

European society (Award 2014)

Funding for HUG educational program

A MULTISECTORIAL EXPERTISE

Page 6: The CPR TestLung T

World Innovation Day

29 Aug. 2014 Geneva

A realistic simulator

for cardio-pulmonary resuscitation training

Dr. Jean-Christophe Richard,A Lyazidi, R Cordioli, L Suppan, G Gheno, D SavaryEmergency and SAMU 74 department, CHANGE INSERM UMR 955 Eq13

REVA: Réseau Européen de Ventilation Mécanique

Page 7: The CPR TestLung T

World Innovation Day

28 Aug. 2014 Geneva

Page 8: The CPR TestLung T

• More physiologic & realist simulator to manage both

chest compression (CC) & ventilation dosage

• Allows a better understanding of CC and ventilation

interactions

• A portable device adaptable to current training

mannequins - to be manufactured in different sizes

• 100% compliant towards CPR recommendations

A REAL INNOVATION IN CPR EDUCATION

CPR TestLung simulator

Page 9: The CPR TestLung T

A SIGNIFICANT IMPACT ON PUBLIC HEALTH

Multiple use & large public – mobile device

• To do well, understand & practice !

• Up-to-date staff education, almost everywhere

• To complete Health & Safety policies in corporate environment

• On a public health level (driving licence, sports, on the street or at home)

• Medical & industrial fields (R&D)

Page 10: The CPR TestLung T

The CPR TestLung

The 1st realist & physiologic lung simulator

adaptable in different training mannequins,

portable for CPR staff training

in any kind of environment.