Paramount® Ductless Enclosures
The material included in this presentation is copyright of Labconco
Corporation. Reproduction or use of the slides is not permitted without express
permission from Labconco Corporation.
Carbon Filtration: The use of carbon media derived from granulated coal carbon or coconut shell carbon to chemically adsorb vaporous/gaseous contaminants
Why Carbon? Why coconut shell carbon media?Adsorption
Paramount® Ductless Enclosures
♦ Chemical’s molecular weight♦ # Carbons in molecular structure♦ Vapor pressure ♦ Chemical displacement♦ Temperature♦ Humidity
Properties that affect filtration efficiency
Paramount® Ductless Enclosures
Activated CarbonOrganic Filters• # Carbons• Molecular weight• Adsorption only
Incomplete saturationStripping from media100% activated carbon
Treated CarbonAcid/Sulfur Formaldehyde/FormalinAmmonia/AmineRadioisotopeMixed Bed• Treated with chemical• Neutralization • Complete saturation
• 75% treated/25% activated
Activated Carbon vs. Treated Carbon Filters
Paramount® Ductless Enclosures
Paramount® Ductless Enclosures
Self‐contained work stations that use carbon filters to protect operator from harmful vapors
Require no ductwork and can be moved from lab to lab
Utilize energy‐efficient motors (ECM)
Patented containment features
Stackable filters for multiple chemical applications
Digital control center with vapor sensor and airflow monitor
Energy efficient ECM motor uses less energy, runs cooler and quieter.
Patented containment enhancing design features ensure operator protection from fumes, vapors, gases and particles.
LCD display with digital control center, Safety‐First™Vapor Sensor and Smart‐Flow™ Airflow Monitor to monitor filter breakthrough and air speed to maintain user safety at all times.
Paramount® Ductless Enclosures
Paramount® Ductless Enclosures
Quieter, cooler and more energy-efficient ECM impeller
Fluorescent light illuminates interior.
Patented rear baffle
Ergonomic angled sash and patented sloped front
Upper Dilution Air Supply sweeps clean air to back of the sash
Smart-Flow System adjusts motor speed automatically—maintains constant airflow at calibrated value
Accommodate seven filter types to cover a wide variety of needs
Upper Containment Sash Foil directs contaminants away from user’s breathing zone
Patented Clean-Sweep™ Air Foil
Side-entry air foils
Optional clear safety glass baffle provides 360º visibility
Safety-First™ Vapor Sensor
Filter efficiency performance independently verified by University of Kansas
Seven different stackable filters can be combined to handle different chemicals at the same time.
Solid and durable construction.
Available in multiple widths, depths and heights.
Paramount® Ductless Enclosures
Energy SavingsRecirculation of filtered, tempered air eliminates energy waste associated with traditional, ducted fume hoods.
The ECM motor and light fixture in a 3′ Paramount unit use only 65 watts — about as much energy as one 60 watt light bulb!
(Previous 3’ model used 330 watts)
Reduced Heat Load3’ unit heat load of 222 BTU/hr
Previous 3’ model heat load of 1126 BTU/hr
Noise Reduction3’ ranges 46‐62dbA vs. previous model 65dbA
6’ ranges 57‐66dbA vs. previous model 68dbA
Paramount® Ductless Enclosures
Patented slotted rear baffle promotes horizontal laminar flow reducing
turbulence
Upper Containment Sash Foil directs contaminants away from the
operator’s breathing zone
Paramount® Ductless Enclosures
Containment enhancing features
Side Entry Air Foils promote horizontal flow and direct airflow into the
enclosure work area
Aerodynamic airfoil with Clean‐Sweep™
openings directs air into the enclosure and across the work surface
Paramount® Ductless Enclosures
Containment enhancing features
Upper Dilution Air Supply purges the top of the chamber and bathes the area behind the sash in clean room air
Paramount® Ductless Enclosures
Containment enhancing features
LCD Screen DisplayFilter type
Filter life
Airflow
Alarms/alert messages
Blower, Light, and Task timers
Touchpad and screen at eye level
Digital Control Center
Paramount® Ductless Enclosures
Maintains constant airflow
Displays face velocity on LCD Display
Visible/Audible alarms are displayed on LCD display
Smart-Flow™ Airflow Monitor
Paramount® Ductless Enclosures
Paramount® Ductless Enclosures
Safety-First™ Vapor Sensor
Detects chemical breakthrough and filter saturation
Visible/Audible alarms are displayed on LCD display
Vapor sensor optimal detection concentration 1‐10ppm vs. current sensor calibrated at 50ppm.
Two sensors allow safety backup monitoring of breakthrough.
Accurate detection of breakthrough maintains operator safety.
Early alert detects initial breakthrough and provides warning message to user that approximately 5‐10% filter life remains.
Toluene“Methyl benzene”C6H5CH3
Mol. Wgt – 92.1Exp. Limit – 100ppmOdor Thrsh. – 0.16ppmFilter capacity – 20.1%
Paramount® Ductless Enclosures
Safety-First™ Vapor Sensor
Methanol“Methyl alcohol”CH3OHMol. Wgt. – 32.1Exp. Limit – 200ppmOdor Thrsh. – 141ppmFilter capacity – 0.1%
Organic Vapor
Acid‐Sulfur
Ammonia‐Amine
Formaldehyde‐Formalin
Mixed BedOrganic, Acid, Ammonia, Formaldehyde
25% each
Paramount® Ductless Enclosures
Available Filters
Paramount® Ductless Enclosures
Available Filters
RadioisotopeIodine, Iodoform, Methyl Iodine
Isotopes of Iodine normally found in Nuclear Pharma or Nuclear Power plants. Not for nuclear weapon waste or etc.
HEPA
Stackable Filters
Paramount® Ductless Enclosures
Chemically resistant coated steel and aluminum and safety glass construction yield solid, sturdy and durable enclosures
Epoxy coating resists chemical corrosion
Safety glass resists crazing
Maximizes enclosure life, stretching valuable budget dollars
Solid Construction
Paramount® Ductless Enclosures
Labconco Corporation, 8811 Prospect Avenue, Kansas City, MO 64132