Nickel Titanium Instruments in Endodontics: Part 2 Dr. Ashok Ayer Department of Conservative Dentistry & Endodontics College of Dental Surgery BPKIHS, Dharan

Nickel Titanium Instruments in Endodontics

Embed Size (px)

DESCRIPTION

Nickel Titanium Endodontic Instruments, properties, use and comaparison. Components, Design.

Citation preview

Page 1: Nickel Titanium Instruments in Endodontics

Nickel Titanium Instruments in Endodontics: Part 2

Dr. Ashok AyerDepartment of Conservative Dentistry & EndodonticsCollege of Dental SurgeryBPKIHS, Dharan

Page 2: Nickel Titanium Instruments in Endodontics

Contents:

1. Components of an endodontic rotary instrument

2. Instrument Designs

3. K-file

4. Reamers

5. Hedström Files

6. Gates-Glidden Drills

7. Instrument design Modifications

8. LightSpeed and LightSpeed LSX Instruments

9. ProFile

10. GT and GTX Files

11. HERO 642, Hero Shaper

12. ProTaper Universal

13. ProTaper Next

14. K3

15. FlexMaster

16. RaCe, Bio Race

17. EndoSequence

18. Twisted File

19. Path files

20. Self-adjusting file

21. ENDO-EZE reciprocating files

22. The WaveOne single-file reciprocating system

23. Endo Express and Safe Sider

24. Revo-S Sequence

25. Mtwo

26. Conclusions

27. References:

Page 3: Nickel Titanium Instruments in Endodontics

Components of an endodontic rotary instrument

Page 4: Nickel Titanium Instruments in Endodontics

Components of Endodontic Instruments

Flute:

Groove in the working surface used to collect soft tissue and dentine chips removed from the canal wall.

The effectiveness of the flute depends on its depth, width, configuration, and surface finish.

Its effectiveness depends on its angle of incidence and sharpness.

Page 5: Nickel Titanium Instruments in Endodontics
Page 6: Nickel Titanium Instruments in Endodontics

Radial land/ marginal width:

Is a flat cutting surface present between two grooves/ flutes.

The land touches the canal walls at the periphery of the file and reduces the tendency of the file to screw into the canal,

Reduces transportation of the canal.

Reduces the propagation of microcracks on its circumference,

Supports the cutting edge, and

Limits the depth of cut.

Page 7: Nickel Titanium Instruments in Endodontics

Disadvantages: Clogging of the instruments, Friction and heat build-up, Inefficient cutting.

Rotary Profile niTi file, #5 (denTSPLY Tulsa dental, Tulsa, OK). note the instrument’s wide marginal land (arrows)

Page 8: Nickel Titanium Instruments in Endodontics

Relief: Surface area of land that is reduced to a

certain extent to reduce frictional resistance.

Helix angle:The angle the cutting edge forms with the

long axis of the file.Augers debris collected in the flute from the

canal. This angle is important for determining

which file technique to use.

Page 9: Nickel Titanium Instruments in Endodontics

Components of the Quantec niTi rotary instrument (Sybronendo, Orange, CA)

Page 10: Nickel Titanium Instruments in Endodontics

Rake angle Is the angle formed by the leading edge and the

radius of the file.

If the angle formed by the leading edge and the surface to be cut (its tangent) is obtuse, the rake angle is said to be positive or cutting.

If the angle formed by the leading edge and the surface to be cut is acute, the rake angle is said to be negative or scraping

Page 11: Nickel Titanium Instruments in Endodontics

Positive and negative rake angles.

Positive angle results in cutting action

Negative angle results in scraping action.

Page 12: Nickel Titanium Instruments in Endodontics

However, the rake angle may not be the same as the cutting angle.

The cutting angle, or the effective rake angle, is a better indication of a file’s cutting ability and is determined by measuring the angle formed by the cutting (leading) edge and the radius when the file is sectioned perpendicular to the cutting edge.

If the flutes of the file are symmetric, the rake angle and the cutting angle are essentially the same.

Page 13: Nickel Titanium Instruments in Endodontics

The pitch of the file is the distance between a point on the leading edge and the corresponding point on the adjacent leading edge.

Most files have a variable pitch, one that changes along the working surface.

Because the diameter increases from the file tip toward the handle, the flute becomes proportionately deeper, resulting in a core taper that is different from the external taper.

Page 14: Nickel Titanium Instruments in Endodontics

WaveOne variable pitch flute increases safety

Page 15: Nickel Titanium Instruments in Endodontics

Instrument Designs

1. The difference between the file’s minimum and maximum diameters can be reduced so that the torque required for rotating the larger diameter does not exceed the plastic limit of the smaller diameter.

2. The space between the tip and the maximum diameter can be reduced so that the required torque does not exceed the ultimate strength of any part of the file.

Cohen and Hargreaves. Pathways of pulp,10th edition

Page 16: Nickel Titanium Instruments in Endodontics

3. A zero taper or nearly parallel and fluted working portion of the file can be provided for curved canals so that the apical portion of the canal can be enlarged without undue file stress and compression of debris.

4.The continuity of the blade engagement can be interrupted.

5.The number of flute spirals can be eliminated or reduced to the smallest number necessary to prevent excessive torque, which results from the accumulation of debris.

6. Means can be provided to complete the file function before the flutes fill with debris.

Page 17: Nickel Titanium Instruments in Endodontics

7.Any land width can be minimized to reduce abrasion on the canal surface.

8.The file can be given an asymmetric cross-section to help maintain the central axis of the canal.

9.The number of flutes with similar helix angles can be reduced. When helix angles are dissimilar, screwing-in forces are reduced; when flutes have no helix angles, screwing- in forces are eliminated.

Page 18: Nickel Titanium Instruments in Endodontics

10. Positive cutting angles can be incorporated to enhance the efficiency of canal enlargement.

11. Blades can be made appendages or projections from the file shaft rather than ground into the shaft.

12. Channels can be cut along the long axis of the file to facilitate its removal if it breaks.

Page 19: Nickel Titanium Instruments in Endodontics

K-file

K-files were manufactured by twisting square or triangular metal blanks along their long axis, producing partly horizontal cutting blades.

The tip is cutting and pyramidal

Helical angle: 45˚

Noncutting tips, also called Batt tips, are created by grinding and smoothing the apical end of the instrument

Page 20: Nickel Titanium Instruments in Endodontics

NiTi K-files are extremely flexible and are especially useful for apical enlargement in severe apical curves.

They can be precurved, but only with strong overbending; this subjects the file to excess strain and should be done carefully.

Because of their flexibility, the smaller NiTi files (sizes up to #25) are of limited use.

Page 21: Nickel Titanium Instruments in Endodontics
Page 22: Nickel Titanium Instruments in Endodontics

Cross-sectional analysis of a K-file reveals why this design allows careful application of clockwise and counter clockwise.

Rotational and translational working strokes.

Page 23: Nickel Titanium Instruments in Endodontics

Modification of K- files:

K flex file:

Rhomboidal/ diamond cross- section

Increased flexibility and cutting efficiency

Page 24: Nickel Titanium Instruments in Endodontics

K- flex O file:

Twisting a triangular cross section blank

Non- cutting tip

Increased flexibility but less cutting efficiency

Page 25: Nickel Titanium Instruments in Endodontics

K- flex R file/ Roane file

Machined from triangular cross section blank

Modified safe-end tip. (reduction in cutting tip angle).

Balanced force technique, cuts during anticlockwise rotary motion

Page 26: Nickel Titanium Instruments in Endodontics

Triple flex file:

Triangular stainless steel wire is twisted

Has more flutes than reamer but less than K- file.

Page 27: Nickel Titanium Instruments in Endodontics

C + files:

Better buckling resistance than K – file

Sizes: 008, 010, 015

Length: 18, 21, 25 mm

Used for initial penetration and cut better, especially in calcified canals.

Page 28: Nickel Titanium Instruments in Endodontics

Reamers Triangular or square blank

Triangular blanks are more flexible, have a larger groove, more susceptible for fracture.

Square blanks are stable and rigid and have smaller groove.

Helical angle 20˚

Reaming: penetration, rotation (¼- ½) and retraction.

Retraction brings about the cutting action.

Page 29: Nickel Titanium Instruments in Endodontics

Less flutes compared to K-file:

Files: tighter flutes: 1.93- 0.88 mm Reamers: looser flutes: 0.80- 0.28 mm

Example; No. 30 file: 22 flutes per 16 mm of blade No. 30 reamer: 15 flutes per 16 mm of

blade.

Page 30: Nickel Titanium Instruments in Endodontics

Hedström Files Hedström files are milled from round stainless steel blanks.

Cutting action: Retraction

They are very efficient for translational strokes, but rotational working movements are strongly discouraged because of the possibility of fracture.

Helical angle: 60˚

Better cutting action than K-file (more positive rake angle).

Page 31: Nickel Titanium Instruments in Endodontics
Page 32: Nickel Titanium Instruments in Endodontics

Hedström files up to size #25 can be efficiently used to relocate canal orifices and, with adequate filing strokes, to remove overhangs.

Similarly, wide oval canals can be

instrumented with Hedström files as well as with rotary instruments.

Page 33: Nickel Titanium Instruments in Endodontics

Modifications:

Unifile/ Dyanatrak:

Designed with two spirals for cutting blades

Cross section: ‘S’ shaped double helix

High incidence of separation.

Others: Hyflex file, S- file, Triple helix

Page 34: Nickel Titanium Instruments in Endodontics

A- file:

Variant of H- file

More flexible

Flutes/ cutting edges are at acute angle to the long axis of the file.

When used in curved canals,

Flutes on the inner edge collapse and hence no dentine is removed,

On the outer edge it opens, filling the dentine on the outer curvature (simulates anticurvature filling)

Page 35: Nickel Titanium Instruments in Endodontics

U - file

Heath 1988

Cross- section: Six corners, two 90˚ cutting edges at each of the three points of the blade.

Radial land

Adapt well to curved canals

Non cutting tip

E.g. Profile, GT files, Light speed, Ultra-flex files

Page 36: Nickel Titanium Instruments in Endodontics

Gates-Glidden Drills

GG instruments are manufactured in a set and numbered 1 to 6 (with corresponding diameters of 0.5 to 1.5 mm)

GG drills are side-cutting instruments with safety tips; they can be used to cut dentin as they are withdrawn from the canal

GG instruments should be used only in the straight portions of the canal, and they should be used serially and passively

NiTi: FlexoGates

Page 37: Nickel Titanium Instruments in Endodontics
Page 38: Nickel Titanium Instruments in Endodontics
Page 39: Nickel Titanium Instruments in Endodontics

Instrument design Modifications

The instrument tip has two functions:

To guide the file through the canal and

To enlarge the canal.

Page 40: Nickel Titanium Instruments in Endodontics

A clinician who is unfamiliar with the tip design of a particular instrument is apt to do either of the following:

Transport the canal (if the tip is capable of enlarging the canal and remains too long in one position)

Encounter excessive torsion and break the file (if a noncutting tip is forced into a canal with a smaller diameter than the tip).

Transportation of the original axis of the canal can occur by remaining too long in a curved canal with a tip that has efficient cutting ability.

Page 41: Nickel Titanium Instruments in Endodontics

As long as the file is engaged 360 degrees, canal transportation is unlikely to occur.

Only with overuse does the file begin to cut on one

side, resulting in transportation.

Most instrumentation errors occur when the file tip is

loose in the canal, which gives it a propensity to transport the canal.

If the canal is smaller than the file, the prudent use of a cutting tip is more efficient.

If the canal is larger than the tip, using a less-effective cutting tip can help prevent transportation.

Cohen and Hargreaves. Pathways of pulp,10th edition

Page 42: Nickel Titanium Instruments in Endodontics

Instrument System Cross-Section Tip Design Taper Other features

Profile Non cutting Fixed taper 20 degree helix angle & constant pitch Triple U shape with radial lands.Neutral rake angle planes dentin walls.

LightSpeed Non cutting Specific instrument Thin, flexible noncut-ting

sequence produces shaft & short cuttinga tapered shape. Head.

ProTaper Non cutting Variable taper along Pitch & helix anglebalanced to preventtaper lock.Convex triangular shape, sharp cutting edges, no radial lands.

HERO Non cutting Fixed taper; 2,4,6 % Variable pitch. Files have a short cutting portion

(12- 16 mm).Triangular shape with positive rake angle for cutting efficiency.

No radial lands.

Grossman’s Endodontic Practice. 12th Edition

Page 43: Nickel Titanium Instruments in Endodontics

K3 Non cutting Fixed taper Variable pitch & core 2, 4,6 % diameter.

Positive rake angle for cutting efficiencyThree radial lands, relief for reduced friction

FlexMaster Non cutting Fixed taper Individual helical an-gles 2, 4, 6% for each instrument to

Intro file has 11% reduce screw-in ef-fect.

Convex triangular shape with sharp cutting edges & no radial lands

RaCe Non cutting Fixed taper Alternating cutting edges 2,4,6,8,10% along the length due to

alternating twisting & untwisting

Mtwo Non cutting Fixed taper Variable pitch, Steep 4, 5, 6, 7 % helical angle to reduce

screw-in effect.S- shape design with two cutting edges, no radial lands.

Minimum core width to improve flexibilityGrossman’s Endodontic Practice. 12th Edition

Page 44: Nickel Titanium Instruments in Endodontics

Nickel-Titanium Rotary Instruments

The specific design characteristics vary, such as tip sizing, taper, cross section, helix angle, and pitch.

New designs continually are produced, but the extent to which clinical outcomes (if any) will depend on design characteristics is difficult to forecast.

Page 45: Nickel Titanium Instruments in Endodontics

LightSpeed and LightSpeed LSX Instruments

Developed by Steve Senia and William Wildey in the early 1990s and now also known as LS1.

Long, thin non-cutting shaft and short anterior cutting part (0.25- 1.75mm)

A full set consists of 25 LightSpeed LS1 instruments in sizes #20 to #100, including half sizes (e.g., 22.5, 27.5); LSX does not have half sizes, and a set includes sizes #20 to #80.

Page 46: Nickel Titanium Instruments in Endodontics

The recommended working speed for LS1 instruments is 1500 to 2000 rpm and for LSX, 2500 rpm.

Both variants should be used with minimal torque, owing to the thin shaft.

Cross sections of LightSpeed LS1 cutting parts show three round excavations, the U-shape design common to many earlier NiTi instruments,

Whereas the LSX is shaped like a flat chisel in cross section.

Page 47: Nickel Titanium Instruments in Endodontics

design features of a LightSpeed instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM,

×200). C, Lateral view. D, design specifications.

Page 48: Nickel Titanium Instruments in Endodontics

Considerably more flexible than any other instrument on the market.

Cyclic fatigue is lower than with all other instruments, allowing the use of higher rpm speeds.

All Light-Speed instruments feature a noncutting tip.

Page 49: Nickel Titanium Instruments in Endodontics

Because of their design, LightSpeed LS1 and LSX require specific instrumentation sequences to produce canal shapes amenable to root canal filling.

The current recommendation calls for an apical 4-mm zone to be prepared to a cylindrical, nontapered shape.

This section may then be filled with the proprietary SimpliFill system

Page 50: Nickel Titanium Instruments in Endodontics

A low incidence of canal transportation and preparation errors.

Loss of working length was also minimal in most of these studies

Bergmans L et al. Int Endod J 35:820, 2002

Page 51: Nickel Titanium Instruments in Endodontics

Marending M, et al Compared the apical fit in two dimensions of the first K-file versus the first Lightspeed LSX instrument binding at working length after an initial crown-down preparation.

The apical large canal diameter was assessed more accurately by the LSX instruments

Instruments with a flat widened tip were found to determine apical cross-sectional diameter better than round, tapered instruments.

Marending M, et al. International Endodontic Journal, 45, 169–176, 2012.

Page 52: Nickel Titanium Instruments in Endodontics

ProFile

[DENTSPLY Tulsa Dental] was introduced by Ben Johnson in 1994.

Have increased tapers compared with conventional hand instruments

The ProFile system was first introduced as the “Series 29” hand instruments in .02 taper, but it soon became available in .04 and .06 taper.

The tips of the ProFile Series 29 rotary instruments had a constant proportion of diameter increments (29%).

Page 53: Nickel Titanium Instruments in Endodontics

Design features of a ProFile instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200). C, Lateral view. D, design specifications.

Page 54: Nickel Titanium Instruments in Endodontics

Cross sections of a ProFile instrument show a U-shape design with radial lands and a parallel central core.

Lateral views show a 20-degree helix angle, a constant pitch, and bulletshaped noncutting tips.

Together with a neutral or slightly negative rake angle, this configuration facilitates a reaming action on dentin rather than cutting.

Also, debris is transported coronally and is effectively removed from the root canals.

Page 55: Nickel Titanium Instruments in Endodontics

ProFile instruments shaped canals without major preparation errors in a number of in vitro investigations.

A slight improvement in canal shape was noted when size .04 and .06 tapered instruments were used in an alternating fashion.

Bryant ST et al. Int Endod J 31:275, 1998. Int Endod J 32:155, 1999.

Page 56: Nickel Titanium Instruments in Endodontics

Comparative assessments in vitro suggested that ProFile prepared mesial canals in mandibular molars with less transportation than K3 and RaCe.

Loss of working length did not exceed 0.5 mm and was not affected by the use of .06 tapered instruments.

Bryant ST et al. Int Endod J 32:155, 1999.

Al-Sudani D et al. J Endod 32:1198, 2006.

Page 57: Nickel Titanium Instruments in Endodontics

Newer ProFile family of instruments is the Vortex (DENTSPLY Tulsa Dental).

The major change lies in the non-landed cross section, whereas tip sizes and tapers are similar to existing ProFiles.

Manufactured using M-Wire, Profile Vortex also have varying helical angle to counteract the tendency of non-landed files to thread into the root canal.

Page 58: Nickel Titanium Instruments in Endodontics

GT and GTX Files

Steve Buchanan in 1994.

This instrument also incorporates the U-file design and was marketed as ProFile GT.

The system was first produced as a set of four hand-operated files and later as engine-driven files.

Four tapers (.06, .08, .10, and .12).

The maximum diameter of the working part was 1 mm.

This decreased the length of the cutting flutes and increased the taper.

Page 59: Nickel Titanium Instruments in Endodontics

The instruments had a variable pitch and an increasing number of flutes in progression to the tip; the apical instrument diameter is 0.2 mm.

Instrument tips were noncutting and rounded, these design principles are mostly still present in the current incarnation, the GTX instrument.

The main differences are the NiTi alloy type used (M-Wire, manufactured by SportsWire, Langley, OK) and a different approach to instrument usage, emphasizing the use of the #20 .06 rotary.

Page 60: Nickel Titanium Instruments in Endodontics

Design features of a GT-file. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200). C, Lateral view. D, design specifications

Page 61: Nickel Titanium Instruments in Endodontics

The GTX set currently includes tip sizes 20, 30, and 40 in tapers ranging from .04 to .08.

The recommended rotational speed for GT and GTX files is 300 rpm, and the instrument should be used with minimal apical force to avoid fracture of the tip.

Page 62: Nickel Titanium Instruments in Endodontics

Studies on GT files found that the prepared shape stayed centered and was achieved with few procedural errors.

A shaping assessment using μCT showed that GT files machined statistically similar canal wall areas compared with ProFile and LightSpeed preparations.

These walls were homogeneously machined and smooth.

Hata G et al. J Endod 28:316, 2002

Peters OA et al. Int Endod J 34:221, 2001.Park H: Oral Surg Oral Med Oral Pathol Oral Radiol Endod 91:715, 2001.

Page 63: Nickel Titanium Instruments in Endodontics

HERO 642, Hero Shaper

First-generation had neutral or slightly negative rake angles.

Second-generation systems were designed with positive rake angles, which gave them greater cutting efficiency.

HERO instruments (MicroMega, Besançon, France); the original system known as HERO 642 has now been replaced by HERO Shaper, with very little difference in the instrument design.

Page 64: Nickel Titanium Instruments in Endodontics

Cross sections of HERO instruments show geometries similar to those of an H-file without radial lands.

Tapers of .02, .04, and .06 are available in sizes ranging from #20 to #45.

The instruments are relatively flexible (the acronym HERO stands for high elasticity in rotation) but maintain an even distribution of force into the cutting areas.

HERO instruments have a progressive flute pitch and a noncutting passive tip.

Page 65: Nickel Titanium Instruments in Endodontics

Design features of a HeRO instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200). C, Lateral view. D, design specifications

Page 66: Nickel Titanium Instruments in Endodontics

Research with HERO files indicates a shaping potential similar to that of the FlexMaster and the ProFile.

HERO Shapers were found to have a better centering ability compared to RaCe instruments in resin blocks.

Hülsmann M et al. Int Endod J 36:358, 2003. Garala M et al. Int Endod J 36:636, 2003.

Aydin C et al. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105:e92, 2008.

Page 67: Nickel Titanium Instruments in Endodontics

ProTaper Universal

The instruments were designed by Cliff Ruddle, John West, and Pierre Machtou.

Originally comprised just six instruments: three shaping files and three finishing files.

This set is now complemented by two larger finishing files and a set designed for retreatment procedures.

Page 68: Nickel Titanium Instruments in Endodontics

In cross section, ProTaper shows a modified K-type file with sharp cutting edges and no radial lands.

This creates a stable core and sufficient flexibility for the smaller files.

The cross section of finishing files F3, F4, and F5 is slightly relieved for increased flexibility.

A unique design element is varying tapers along the instruments’ long axes.

The three shaping files have tapers that increase coronally, and the reverse pattern is seen in the five finishing files.

Page 69: Nickel Titanium Instruments in Endodontics

The differences between Shaping and Finishing file shapes

Page 70: Nickel Titanium Instruments in Endodontics

Design features of a ProTaper instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200). C, Lateral view. D, design specifications.

Page 71: Nickel Titanium Instruments in Endodontics

Tip diameter (mm)

Sx 0.19 At D9 = 1.1 mm

S1 0.185 At D14 =1.2 mm

S2 0.20 At D14 = 1.1 mm

Tip Diameter (mm) Taper (mm)

(D₀- D₃)

F1 0.2 0 7%

F2 0.25 8%

F3 0.30 9%

F4 0.40 5%

F5 0.50 4%

Page 72: Nickel Titanium Instruments in Endodontics

Cross section of Finishing files Triangular cross section of Shaping files

Page 73: Nickel Titanium Instruments in Endodontics

The finishing files have rounded noncutting tips.

The convex triangular cross section of ProTaper instruments reduces the contact areas between the file and the dentin.

The first is the preparation of a glide path, either manually or with special rotary instruments.

Page 74: Nickel Titanium Instruments in Endodontics

Optimal helical angle with variable pitch on the cutting flutes, designed to maximise efficiency and again prevent the file screwing into the canal.

The tip design is a modified non-cutting tip which acts as a guide in the root canal but does not cut.

Page 75: Nickel Titanium Instruments in Endodontics

A more lateral “brushing” working stroke. Such a stroke allows the clinician to direct larger files coronally away from danger zones and counteract any “threading-in” effect.

In a study using plastic blocks, the ProTaper created acceptable shapes more quickly than GT rotary, ProFile, and Quantec instruments but also created somewhat more aberrations.

Yun HH et al. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 95:228, 2003.

Page 76: Nickel Titanium Instruments in Endodontics

A study using μCT showed that the ProTaper created consistent shapes in constricted canals, without obvious preparation errors, although wide canals may be insufficiently prepared with this system.

It has been recommended that ProTaper be combined with less tapered, more flexible rotaries to reduce apical transportation.

Peters OA et al. Int Endod J 36:86, 2003. Javaheri HH et al. J Endod 33:284, 2007

Page 77: Nickel Titanium Instruments in Endodontics

Protaper Next

The convergence of a variable tapered design on a given file (ProTaper Universal), innovative M-Wire technology, and a unique offset mass of rotation.

Off-centred, rectangular cross section giving the files a unique, snake-like swaggering movement.

This improved action creates an enlarged space for debris removal, optimises the canal tracking and reduces binding.

Page 78: Nickel Titanium Instruments in Endodontics

X1, X2, X3, X4, and X5

Corresponding to sizes:17/04, 25/06, 30/07, 40/06, and 50/06, respectively.

Recommended speed is 300RPM with a torque from 4-5.2Ncm.

Page 79: Nickel Titanium Instruments in Endodontics

M-Wire technology: Improves the resistance to cyclic fatigue by almost 400% when comparing files of the same tip diameter, taper and cross-section.

Offset mass of rotation: Asymmetrical rotary motion and, at any given cross-section, the file only contacts the wall at 2 points.

Page 80: Nickel Titanium Instruments in Endodontics

Clinically, this provides 3 significant advantages: Reduced engagement due to the swaggering effect

which limits undesirable taper lock.

Affords more cross-sectional space for enhanced cutting, loading, and augering debris.

Allows any PTN file to cut a bigger envelope of motion compared to a similarly-sized file with a symmetrical mass and axis of rotation.

This means a smaller-sized and more flexible PTN file can cut the same-size preparation as a larger and stiffer file with a centered mass and axis of rotation.

Page 81: Nickel Titanium Instruments in Endodontics

K3

Dr. McSpadden; the Quantec 2000 files were followed by the Quantec SC, the Quantec LX, and the current K3 system (all by SybronEndo).

The overall design of the K3 is similar to that of the ProFile and the HERO in that it includes instruments with .02, .04, and .06 tapers.

The most obvious difference between the Quantec and K3 models is the K3’s unique crosssectional design: a slightly positive rake angle for greater cutting efficiency, wide radial lands, and a peripheral blade relief for reduced friction.

Page 82: Nickel Titanium Instruments in Endodontics

Design features of a K3 instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200). C, Lateral view. D, design specifications.

Page 83: Nickel Titanium Instruments in Endodontics

Unlike the Quantec, a two flute file, the K3 features a third radial land to help prevent threading-in.

In the lateral aspect, the K3 has a variable pitch and variable core diameter, which provide apical strength.

This complicated design is relatively difficult to

manufacture, resulting in some metal flash

A round safety tip, but the file is about 4 mm shorter than other files

Page 84: Nickel Titanium Instruments in Endodontics

Tested in vitro, K3’s shaping ability seems to be similar to that of the ProTaper and superior to that achieved with hand instruments.

Bergmans L et al. Int Endod J 36:288, 2003.Schäfer E et al. Int Endod J 36:199, 2003.

Page 85: Nickel Titanium Instruments in Endodontics

FlexMaster

.02, .04, and .06 tapers.

The cross sections have a triangular shape, with sharp cutting edges and no radial lands.

This makes for a relatively solid instrument core and excellent cutting ability.

The overall manufacturing quality is high, with minimal metal flash and rollover.

Page 86: Nickel Titanium Instruments in Endodontics

Design features of a FlexMaster instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200). C, Lateral view. D, design specifications.

Page 87: Nickel Titanium Instruments in Endodontics

Have rounded, passive tips; the tip diameters are 0.15 to 0.7 mm for size .02 instruments and 0.15 to 0.4 mm for size .04 and .06 files.

In addition to the standard set, the Intro file, which has a 0.11 taper and a 9-mm cutting part, is available

Page 88: Nickel Titanium Instruments in Endodontics

Several studies indicate that the FlexMaster allows centered preparations in both constricted and wider canals and that it performed on par with other systems.

Hübscher W et al. Int Endod J 36:740, 2003.

Hülsmann M et al. Int Endod J 36:358, 2003.

Weiger R et al. Int Endod J 36:483, 2003.

Page 89: Nickel Titanium Instruments in Endodontics

RaCe, Bio Race

The name, which stands for reamer with alternating cutting edges, describes just one design feature of this instrument

Light microscopic imaging of the file shows flutes and reverse flutes alternating with straight areas; this design is aimed at reducing the tendency to thread the file into the root canal.

Cross sections are triangular or square for #.02 instruments with size #15 and #20 tips.

The lengths of cutting parts vary from 9 to 16 mm

Page 90: Nickel Titanium Instruments in Endodontics

Design features of an RaCe instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200).C, Lateral view. D, design specifications.

Page 91: Nickel Titanium Instruments in Endodontics

The surface quality of RaCe instruments has been modified by electropolishing.

Two largest files (size #35, #.08 taper and size #40, #.10 taper) are also available in stainless steel.

The tips are round and noncutting

Page 92: Nickel Titanium Instruments in Endodontics

EndoSequence

The Sequence rotary instrument is produced by FKG in Switzerland and marketed in the United States by Brasseler.

This is another instrument that adheres to the conventional length of the cutting flutes, 16 mm, and to larger tapers, .04 and .06, to be used in a crown-down approach

Page 93: Nickel Titanium Instruments in Endodontics

Design features of a Sequence instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200). C, Lateral view. D, design specifications.

Page 94: Nickel Titanium Instruments in Endodontics

A unique longitudinal design called alternating wall contact points (ACP) reduce torque requirements and keep the file centered in the canal

An electrochemical treatment after manufacturing, similar to RaCe files, that results in a smooth, polished surface.

This is believed to promote better fatigue resistance, hence a rotational speed of 600 rpm is recommended for EndoSequence.

Koch KA et al. Dent Clin North Am 48:159,2004.

Page 95: Nickel Titanium Instruments in Endodontics

Twisted File

In 2008, SybronEndo presented the first fluted NiTi file.

Manufactured by plastic deformation, a process similar to the twisting process that is used to produce stainless steel K-files.

According to the manufacturer, a thermal process allows twisting during a phase transformation into the so called R-phase of nickel-titanium.

The instrument is currently available with size #25 tip sizes only, in taper .04 up to .12.

Page 96: Nickel Titanium Instruments in Endodontics

Design features of a Twisted File (TF) instrument. A, Lateral view (scanning electron micrograph [SeM], ×50). B, Cross section (SeM, ×200). C, Lateral view. D, design specifications.

Page 97: Nickel Titanium Instruments in Endodontics

Twisted Files size #25 .06 taper were more flexible than ProFiles of the same size.

The manufacturer recommends a conventional crown-down technique after securing a glide path with a size #15 K-file.

Specifically, for a “large” canal, tapers .10 to .06 should be used, and in a “small” canal, tapers .08 to .04 are recommended.

Gambarini G et al. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 105:798, 2008

Page 98: Nickel Titanium Instruments in Endodontics

Path Files

Mechanical glide path and Preflaring.

Available in 3 ISO sizes (013, 016 and 019) and 3 lengths (21, 25 and 31mm).

Flexible and resistant to cyclic fatigue, they offer many advantages compared to manual solutions

Page 99: Nickel Titanium Instruments in Endodontics

NiTi – Square Section – 2% Taper

High strength against cyclic fatigue

Flexibility

Tip design (transition angle reduction)

Reduced risk of ledges and canal transportation

PathFile™ K-File

Page 100: Nickel Titanium Instruments in Endodontics

Helio P. Lopes et al.

(Buckling Resistance of Pathfinding Endodontic Instruments):

The results indicated that the buckling resistance decreased in the following order: C+ file > C-Pilot file > PathFile

Considering that buckling resistance may influence the performance of instruments during the negotiation of constricted canals, the C+ files showed significantly better results than the other instruments tested.

Helio P. Lopes et al . J Endod 2012;38:402–404

Page 101: Nickel Titanium Instruments in Endodontics

Self-adjusting file

The instrument is made as a hollow, thin NiTi lattice cylinder that is compressed when inserted into the root canal and adapts to the canal’s cross-section.

It is attached to a vibrating handpiece.

Continuous irrigation is applied through a special hub on the side of its shank.

Page 102: Nickel Titanium Instruments in Endodontics

The SAF instrument adapted into a root canal that was initially prepared with #20 K-file.

Right: A #20 K-file in the canal.

Left: The SAF file in its relaxed form.

Center: The SAF file inserted into the same narrow canal.

It will apply delicate pressure on the canal wall, attempting to resume its original shape.

Page 103: Nickel Titanium Instruments in Endodontics

The abrasive surface and details of the lattice of the SAF instrument.

The extreme elasticity is the total of the elasticity of each of the delicate NiTi segments.

Page 104: Nickel Titanium Instruments in Endodontics

The VATEA continuous irrigation unit used with the SAF instrument.

The unit has two containers and provides a continuous flow (low pressure, 5 ml/min) of either irrigant (i.e., sodium hypo-chlorite and edTA) through double silicon tubes that are connected to the hubs on the front of the device.

It is controlled by finger-operated switches located on the handpiece.

Page 105: Nickel Titanium Instruments in Endodontics

A micro–computed tomography (microCT) analysis of the operation of the SAF instrument in a flat canal with extremely oval cross-section.

Right: Buccolingual and mesiodistal views of the root canal reconstructed from microCT.

Left: Cross-sections at 4 and 6 mm from the apex.

Red: before, blue: after treatment.

Page 106: Nickel Titanium Instruments in Endodontics

ENDO-EZE reciprocating files

The endo-eze file system (Ultradent, South Jordan, UT) is a recently introduced addition for Giromatic handpieces.

The set has four instruments that are designed to clean the middle third of the canal.

The sizes and tapers are 0.10 #0.025 taper, 0.13 #0.35 taper, 0.13 #0.45 taper and 0.13 #0.06 taper.

The use of stainless steel hand instruments is suggested for the apical third of the canal

Page 107: Nickel Titanium Instruments in Endodontics
Page 108: Nickel Titanium Instruments in Endodontics
Page 109: Nickel Titanium Instruments in Endodontics

The WaveOne single-file reciprocating system

Single-use, Single-file system to shape the root canal completely from start to finish.

M-Wire technology. Improving strength and resistance to cyclic fatigue

by up to nearly four times in comparison with other rotary NiTi files.

At present, there are three files in the WaveOne single-file reciprocating system available in lengths of 21, 25 and 31 mm

Page 110: Nickel Titanium Instruments in Endodontics
Page 111: Nickel Titanium Instruments in Endodontics

The WaveOne Small file is used in fine canals. The tip size is ISO 21 with a continuous taper of 6 %.

The WaveOne Primary file is used in the majority of anals. The tip size is ISO 25 with an apical taper of 8 % that reduces towards the coronal end.

The WaveOne Large file is used in large canals. The tip size is ISO 40 with an apical taper of 8 % that reduces towards the coronal end

Page 112: Nickel Titanium Instruments in Endodontics

The instruments are designed to work with a reverse cutting action.

All instruments have a modified convex triangular cross-section at the tip end, and a convex triangular cross-section at the coronal end . This design improves instrument flexibility overall

WaveOne apical cross-section, modified convex triangular

WaveOne coronal cross-section, convex triangular.

Page 113: Nickel Titanium Instruments in Endodontics

WaveOne variable pitch flute increases safety

Page 114: Nickel Titanium Instruments in Endodontics

The specially designed NiTi files work in a similar but reverse “balanced force” action using a pre-programmed motor to move the files in a back and forth “reciprocal motion”

The counter-clockwise (CCW) movement is greater than the clock-wise (CW) movement. CCW movement advances the instrument, engaging and cutting the dentine.

CW movement disengages the instrument from the dentine before it can (taper) lock into the canal.

Three reciprocating cycles complete one complete reverse rotation and the instrument gradually advances into the canal with little apical pressure required.

Page 115: Nickel Titanium Instruments in Endodontics

Clinical procedure

Page 116: Nickel Titanium Instruments in Endodontics

Endo Express and Safe Sider

Reciprocating Motion.

SafeSiders have 16 flutes compared to 24 flutes for files.

Less flutes leads less engagement with the walls of the canal which means less resistance, binding and virtually no instrument separation.

Page 117: Nickel Titanium Instruments in Endodontics

Flat-side of the SafeSider:Act as chisels in the clockwise and counter

clock-wise motion allow to remove debris easily.

SafeSiders are safely used at least 3 times more than NiTi instruments before they are discarded.

Page 118: Nickel Titanium Instruments in Endodontics

Revo-S Sequence

The asymmetrical cutting profile of the Revo-S facilitates penetration by a snake-like movement, and offers, a root canal shaping which is adapted to the biological and ergonomic imperatives.

It is composed of only two instruments for apical penetration (SC1 and SC2), and a recapitulating and cleaning instrument (SU)

Page 119: Nickel Titanium Instruments in Endodontics

Revo-S instruments for apical progression (SC1 & SC2), & cleaning (SU).

The working lengths are adapted for a crown-down preparation. The asymmetry alternates with the symmetry, in order to optimize the canal penetration (SC1), the strength (SC2), & the cleaning (SU)

Page 120: Nickel Titanium Instruments in Endodontics

Apical finishing instruments with an asymmetrical cross section allowing the final shaping of the apical third.

The selection of preparation diameter adapted to most clinical cases, and Cleaning without pushing debris beyond the apical foramen

Page 121: Nickel Titanium Instruments in Endodontics

Mtwo VDW, Munich, Germany

The standard set for this system includes four instruments with variable tip sizes ranging from #10 to #25, and tapers ranging from .04 to .06 (size 10/.04 taper, size 15/.05 taper, size 20/.06 taper, size 25/.06 taper

Page 122: Nickel Titanium Instruments in Endodontics

After this basic sequence, that gives the canal a #25/.06 shape, the system is conceived to permit three different approaches to root canal preparation.

The first sequence allows clinicians to achieve enlarged apical diameters using the size 30 (.05) taper, 35 (.04) taper or 40 (.04) taper;

The second leads to a .07 taper that can facilitate vertical condensation of gutta-percha, maintaining a size #25 apical preparation;

The third implies the use of the Mtwo apical files

Page 123: Nickel Titanium Instruments in Endodontics
Page 124: Nickel Titanium Instruments in Endodontics

SEM image of Mtwo instrument cross-section, showing the two blade cutting surfaces resulting in an “Italic S” design.

.

Page 125: Nickel Titanium Instruments in Endodontics

The Helical angle (HA) of Mtwo instruments is variable and specific for the different files

HA is more open (greater) for the bigger sizes (less flutes for instrument length), and it decreases for the smaller sizes (more flutes).

This determines a greater cutting efficiency for the bigger sizes and a greater mechanical resistance together with a tendency to advance in the canal for the smaller ones.

Page 126: Nickel Titanium Instruments in Endodontics

The HA is variable in the same instruments, it increases from the tip to the handle as does the spiral pitch,

While it is constant for the smaller files, especially for the #10 .04, the first rotary instrument that is introduced in the root canal.

The variable HA reduces the tendency of the instrument to be sucked down into the canal

Page 127: Nickel Titanium Instruments in Endodontics

The MtwoR instruments are specifically designed for the retreatment of obturation materials.

The retreatment files are Mtwo R 15/.05 and Mtwo R 25/.05, presenting an active tip that allows clinicians to easily penetrate obturation material.

Page 128: Nickel Titanium Instruments in Endodontics

Conclusion:

An explosion in knowledge and technology has created an exciting time in the specialty of endodontics.

New instruments and materials seem to appear faster than clinicians can learn about the preceding versions.

This has created an educational challenge for practitioners, universities, and manufacturers, requiring a greater degree of cooperation among these groups than ever before.

Clinicians should only use those instruments and materials

that have been shown safe and effective by independent studies.

Cohen and Hargreaves. Pathways of pulp,10th edition

Page 129: Nickel Titanium Instruments in Endodontics

Most systems include files with tapers greater than the #.02 stipulated by the ISO norm.

The Light-Speed LS1 and LSX are different from all other systems;

The ProTaper, RaCe, and Twisted File have some unique features; and most other systems have increased tapers.

Minor differences exist in tip designs, cross sections, and manufacturing processes, but the clinical effects of these modifications currently are unknown.

Even in vitro, tests have only begun to identify the effect of specific designs on shaping capabilities, and differences in clinical outcomes in regard to these design variations appear to be minimal.

Cohen and Hargreaves. Pathways of pulp,10th edition

Page 130: Nickel Titanium Instruments in Endodontics

References: Cohen and Hargreaves. Pathways of pulp,10 th edition

John I Ingle, Leif K Bakland, J Craig Baumgartner. Endodontics,6 th edition

Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts P: Smooth flexible versus active tapered shaft design using NiTi rotary instruments. Int Endod J 35:820, 2002

Bryant ST, Thompson SA, al-Omari MA, Dummer PM: Shaping ability of ProFile rotary nickel-titanium instruments with ISO sized tips in simulated root canals: Part 1. Int Endod J 31:275, 1998.

Al-Sudani D, Al-Shahrani S: A comparison of the canal centering ability of ProFile, K3, and RaCe Nickel-titanium rotary systems. J Endod 32:1198, 2006.

Hata G, Uemura M, Kato AS, Imura N, Novo NF, Toda T: A comparison of shaping ability using ProFile, GT file, and Flex-R endodontic instruments in simulated canals. J Endod 28:316, 2002

Marending M, Schicht OO, Paqué F. Initial apical fit of K-files versus LightSpeed LSX instruments assessed by micro-computed tomography. International Endodontic Journal, 45, 169–176, 2012.

V. A. Malagino,N. M. Grande, G. Plotino & F. Somma, Italy. The Mtwo NiTi rotary system for root canal preparation. Industry _ grande; roots 3.2006

Page 131: Nickel Titanium Instruments in Endodontics

Sjogren U, Figdor D, Persson S, Sundqvist G. Influence of infection at the time of root filling on the outcome of endodontic treatment of teeth with apical periodontitis. Int Endod J 1997; 30(5): 297–306.

Schilder H. Cleaning and shaping the root canal. Dent Clin Amer 1974; 18(2): 269–96.

West JD. Endodontic predictability—“Restore or remove: how do I choose?” In: Cohen M, ed. Interdisciplinary Treatment Planning: Principles, Design, Implementation. Quintessence Publishing Co., 2008:123–64.

Roane JB, Sabala CL, Duncanson MG. The “balanced force” concept for instrumentation of curved canals. J. Endod1985; 11(5): 203–11.

Johnson E, Lloyd A, Kuttler S, Namerow K. Comparison between a novel nickel titanium alloy and 508 Nitinol on the cyclic fatigue life of Profile 25/.04 rotary instruments. J Endod 2008; 34(11): 1406–9.

Walia HM, Brantley WA, Gerstein H. An initial investigation on the bending and torsional properties of Nitinol root canal files. J Endod 1998; 14(7): 340–51.

Reddy SA, Hicks ML. Apical extrusion of debris using two hand and two rotary instrumentation techniques. J Endod 1998; 249(3): 180–3.

Pettiette MT, Delano EO, Trope M. Evaluation of success rate of endodontic treatment performed by students with stainless steel K files and nickel titanium hand files. J Endod 2001; 27(2): 124–7.

Letters S et al. A study of visual and blood contamination on reprocessed endodontic files from general dental practice. Brit Dent J 2005; 199: 522–5.

Department of Health (UK). Advice for dentists on the re-use of endodontic instruments and variant Creutzfeldt-Jacob Disease (vCJD). April 2007.

Page 132: Nickel Titanium Instruments in Endodontics

E. S. Senia, W. L. Wildey. What ‘s New in Ni-Ti Rotary Instrumentation: Part 2. Dentistry Today, April 2007; Vol. 26: No.4.

Mian Iqbal, Brian Banfield, Amanda Lavorini, Benedict Bachstien. A Comparison of LightSpeed LS1 and Lightspeed LSX® NiTi Rotary Instruments in Apical Transportation and Length Control in Simulated Root Canals. J Endodon, March 2007, 33:3, pp. 268-271. Abstract

E. S. Senia, W. L. Wildey. What’s New in Ni-Ti Rotary Instrumentation: Part 1. Dentistry Today, March 2007; Vol. 26: No. 3.

ADA Professional Product Review. Fall 2006. Vol. 1, Issue 2, pp. 11- 16.

Tibor Bartha, et al. Extended apical enlargement with hand files versus rotary NiTi files. Part II. Oral Surgery, Oral Medicine, Oral Pathology, November 2006, Vol. 102, No. 5, pp. 692-697.

Roland Weiger, et al. A clinical method to determine the optimal apical preparation size. Part I. Oral Surgery, Oral Medicine, Oral Pathology, November 2006, Vol. 102, No. 5, pp. 686-691.

Hülsmann M, Gressmann G, Schäfers F: A comparative study of root canal preparation using FlexMaster and HERO 642 rotary Ni-Ti instruments. Int Endod J 36:358, 2003.

Page 133: Nickel Titanium Instruments in Endodontics

Thank You