43
M Asif Shaheen 1

Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Embed Size (px)

Citation preview

Page 1: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

M Asif Shaheen

1

Page 2: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Introduction Flame photometry more accurately called Flame

Atomic Emission Spectrometry

A flame photometer is an instrument used to

determine the concentration of certain metal ions

among them sodium, potassium, calcium and

lithium.

Flame Photometry is based on measurement of

intensity of the light emitted when a metal is

introduced into flame.

2

Page 3: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Principle When a solution of metallic salt is sprayed as fine

droplets into a flame. Due to heat of the flame, the

droplets dry leaving a fine residue of salt. This fine

residue converts into neutral atoms.

Due to the thermal energy of the flame, the atoms get

excited and there after return to ground state. In this

process of return to ground state, exited atoms emit

radiation of specific wavelength. This wavelength of

radiation emitted is specific for every element

3

Page 4: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

– The wavelength of colour tells what the element is

(qualitative) –

The colour's intensity tells us how much of theelement present (quantitative)

4

Page 5: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

5

Page 6: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy
Page 7: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

7

Page 8: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

8

Page 9: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

9

Page 10: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

10

Page 11: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Nebulizer

Flame

Burners

Mirrors

Slits 11

Page 12: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

This is the component of sample delivery system. which breaks up the bigger liquid droplet to smaller liquid droplets.

The process of conversion of sample to a fine mist of finely divided droplets using a jet of compressed gas is known as Nebulization.

12

Page 13: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Pneumatic nebulizers

Electro thermal vaporizer

Ultrasound nebulizer

13

Page 14: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

PNEUMATIC NEBULIZERS

CONCENTRIC TUBES

CROSS FLOW

BAGINGTON

FRITTED DISK

14

Page 15: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

The liquid sample is sucked through a capillary tube by a high pressure jet of gas flowing around the tip of the capillary.

The high velocity breaks the sample into a mist and carries it to the atomization region.

15

Page 16: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

The jet stream flows right angles to the capillary tip.

It uses a high speed stream of gas perpendicular to the tip of the sample capillary

16

Page 17: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

The jet is pumped through a small orifice in a sphere on which a thin film of sample flows

In this type of nebulizer the sample solution flows freely over small aperture, rather than passing through a fine capillary

17

Page 18: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

The sample is pumped into a fritted disk through which the gas jet is flowing and this gives fine aerosol than others

High efficiencies can be obtained by introducing the sample at predetermined location of the fritted surface

18

Page 19: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

It is an electro thermal vaporizer contains an evaporator in a closed chamber through which an inert gas carries the vaporized sample into the atomizer

19

Page 20: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

The sample is pumped onto the surface of a vibrating piezoelectric crystal.

The resulting mist is denser and more homogeneous than pneumatic nebulizers

20

Page 21: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

21

Page 22: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

It should have proper temperature

Temperature should remain constant throughout the operation

There should not be any fluctuation during burning

To convert the analyte of the liquid sample into vapour state To decompose the analyte into atoms and simple moleculesTo excite the formed atoms/free atoms/simple molecules to emit radiant energy

22

Page 23: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Mecker burner

Total consumption

burner

Premix of laminar flow

burner

Lundergraph burner

Shielded Burner

Nitrous Oxide-

Acetylene Flames

23

Page 24: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

This burner was used earlier and employed natural gas and oxygen. Produces relatively low temp. and low excitation energies. This are best used for ALKALI metals only. Now-a-days it is not used.

24

Page 25: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

In this burner fuel and oxidant are hydrogen and oxygen gases. Sample solution is aspirated through a capillary by high pressure of fuel and Oxidant and burnt at the tip of burner. Entire sample is consumed.

25

Page 26: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

In this type of the burner, aspirated sample, fuel and oxidant are thoroughly mixed before reaching the burner opening and then entering the flame. There is high loss of sample(95%) as large droplets are drained out.

26

Page 27: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

In this sample and air is mixed in a chamber, this mixed composition is send to fuel nozzle where it is atomized. Here the sample reaches the flame is only about 5%

27

Page 28: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

In this flame was shielded from the ambient atmosphere by a stream of inert gas. Shielding is done to get better analytical sensitivity and quieter flame

28

Page 29: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

These flames were superior to other flames for effectively producing free atoms. The drawback of it is the high temperature reduces its usefulness for the determination of alkali metals as they are easily ionized and Intense background emission, which makes the measurement of metal emission very difficult

NITROUS OXIDE ACETYLENE FLAME

29

Page 30: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Fuel Oxidant Temperature 0C

Natural gas Air 1700-1900

Natural gas Oxygen 2700-2800

Hydrogen Air 2000-2100

Hydrogen Oxygen 2550-2700

Acetylene Air 2100-2400

Acetylene Oxygen 3050-3150

Acetylene Nitrous oxide 2600-2800

30

Page 31: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

31

Flame Photometry

Non Flame Atomizers

For example: Heated Gravite Furnace

Sample evaporation→ time and temp. controlled drying and ashing

Advantages

1. small samples are analysed

2. 1000-fold more sensitive than flame

3. Oven is adaptable to determination of solid samples

Disadvantages

1. Low accuracy 2. Low precision

2. More ionic interferences due to very high temp.

Page 32: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

The radiation from the flame is emitted in all the directions in space. Much of the radiation is lost and loss of signal results. A mirror is located behind the burner to reflect the radiation back to the entrance slit of the monochromator. The reflecting surface of the mirror is front-faced.

32

Page 33: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

The entrance and exit slits are used before and after the dispersion elements.

The entrance slit cuts off most if radiation from the surroundings and allows only the radiation from the flame and the mirror reflection of flame to enter the optical system.

The exit slit is placed after the monochromator and allows only the selected wavelength range to pass through the detector

33

Page 34: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Photocell

34

Measures the amount of light passing through the sample. Usually works by converting light signal into electrical signal The least expensive of the devices is known as a barrier-layer cell,

or photocell. The photocell is composed of a film of light-sensitive material,

frequently selenium, on a plate of iron. Over the light-sensitivematerial is a thin, transparent layer of silver. When exposed tolight, electrons in the light-sensitive material are excited andreleased to flow to the highly conductive silver in comparisonwith the silver, a moderate resistance opposes the electron flowtoward the iron, forming a hypothetical barrier to flow in thatdirection. Consequently, this cell generates its own electromotiveforce, which can be measured. The produced current isproportional to incident radiation.

Page 35: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

35

Page 36: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Phototube

The third major type of light detector is the photomultiplier (PM)tube, which detects and amplifies radiant energy.

incident light strikes the coated cathode, emitting electrons. Theelectrons are attracted to a series of anodes, known as dynodes,each having a successively higher positive voltage These dynodes areof a material that gives off many secondary electrons when hit bysingle electrons. Initial electron emission at the cathode triggers amultiple cascade of electrons within the PM tube itself. Because ofthis amplification, the PM tube is 200 times more sensitive than thephototube

36

Page 37: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

PM tubes are used in instruments designed to be extremely sensitive to very low lightlevels and light flashes of very short duration.

The accumulation of electrons striking the anode produces a current signal,measured in amperes, that is proportional to the initial intensity of the light. Theanalog signal is converted first to a voltage and then to a digital signal through theuse of an analog to- digital (A/D) converter. Digital signals are processedelectronically to produce absorbance readings

Page 38: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Readout device.

In the past nearly all spectrophotometer used ammeters or galvanometers. Newer digital devices and printers have now replaced these, and many instruments relay their electrical output directly to computer circuits where calculations are performed, allowing direct reporting of sample concentration.

Microprocessor and recorders

Page 39: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

39

Page 40: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Limitations Limited number of elements that can be analyzed.

The sample requires to be introduced as solution intofine droplets. Many metallic salts, soil, plant and othercompounds are insoluble in common solvents. Hence,they can’t be analyzed by this method.

Since sample is volatilized, if small amount of sampleis present, it is tough to analyze by this method. Assome of it gets wasted by vaporization.

Further during solubilisation with solvents, otherimpurities might mix up with sample and may lead toerrors in the spectra observed.

40

Page 41: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

41

Page 42: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

Chatwal & Anand; Instrumental Methods of Chemical Analysis, 5/e 2013, page no- 2.370 to 2.375, Himalaya Publishing House.

B.K Sharma; Instrumental Methods of Chemical Analysis, 26/e 2007, page no- 430 to 437, GOEL Publishing House.

42

Page 43: Flame photometer (Atomic Emission Spectroscopy) Flame emission spectroscopy

43