14
The first hybrid stent- grafting procedure of thoracic aorta (1991) - successful follow-up for 23 years Professor Nikolay VOLODOS, Kalashnykova Yuliia Kharkov, UKRAINE

Doklad 2 presentation

Embed Size (px)

Citation preview

Page 1: Doklad 2 presentation

The first hybrid stent-grafting procedure of thoracic aorta

(1991) - successful follow-up for

23 years

Professor Nikolay VOLODOS,Kalashnykova YuliiaKharkov, UKRAINE

Page 2: Doklad 2 presentation

HYBRID PROCEDURES List of publications 2013-2014

• De Rango P., Cao P. et al. Aortic debranching and thoracic endovascular repair // J. Vasc. Surg. – 2014. – Vol. 59, N 1. – P.107 - 114.

• Bavaria J., Vallabhajosyula P. et al. Hybrid approach in the treatment of aortic arch aneurysms: postoperative and midterm outcomes // J. Thorac. Cardiovasc. Surg. – 2013. – Vol. 145 (3 Suppl). – P. S85 - 90.

• Benedetto U., Melina G. et al. Current results of open total arch replacement versus hybrid thoracic endovascular aortic repair for aortic arch aneurysm: a meta-analysis of comparative studies // J. Thorac. Cardiovasc. Surg. – 2013. – Vol. 145. – P. 305 - 306.

• Lorii S., Clough R.E. et al. Hybrid repair of complex thoracic aortic arch aneurysm pathology: long-term outcomes of extra-anatomic bypass grafting of the supra-aortic trunk // Cardiovasc. Intervent. Radiol. 2013. – Vol.36. – P. 46 – 55.

• Preventza O., Aftab M., Coselli J.S. Hybrid techniques for complex aortic arch surgery // Texas Heart Institute Journal. – 2013. – Vol.40, N 5. – P.568 – 571.

• Preventza O. et al. Deployment of proximal thoracic endograft in xone 0 of the ascending aorta: treatment options and early outcomes for aortic arch aneurysms in high-risk population // Eur. J. Cardiothorac. Surg. – 2013. – Vol.44, N3. – P.446 – 453.

• Cherny M. et al. Hybrid aortic arch repair // Ann. Cardiothorac. Surg. – 2013. – Vol.2, N3. – P.372 – 377.

• Cherny M. et al. Transposition of the supra-aortic vessels before stent-grafting the aortic arch and descending aorta // J. Thorac. Cardiovasc. Surg. – 2013. – Vol. 145. – P. S91 – 97.

• Vallabhajosyula P. et al. Type II arch hybrid debranching procedure // Ann. Cardiothorac. Surg. – 2013. – Vol.2, N3. – P.378 – 386.

• Andersen N.D. et al. Results with an algorythmic approach to hybrid repair of the aortic arch // J. Vasc. Surg. – 2013. – Vol. 57, N 3. – P.655 - 667.

• Etc.

Page 3: Doklad 2 presentation

The date of procedure

THE FIRST HYBRID PROCEDURE FOR AORTIC ARCH ANEURYSM:

14 JUNE, 1991

Page 4: Doklad 2 presentation

THE FIRST HYBRID PROCEDURE FOR AORTIC ARCH ANEURYSM:

JUNE, 1991 Volodos N.L.,

Karpovich I.P.,

Troian V.I., et al.

Clinical experience of the use of self-fixing synthetic prostheses // Angiologie. - VASA. - 1991. Suppl.33. - P.93-95.

Page 5: Doklad 2 presentation

SCHEMATIC DRAWING OF THE FIRST HYBRID PROCEDURE WITH DEBRANCHING FOR AORTIC ARCH ANEURYSM: JUNE, 1991

Page 6: Doklad 2 presentation

Delivery system for endovascular part of hybrid procedure

Page 7: Doklad 2 presentation

SCHEMATIC DRAWING OF THE FIRST HYBRID PROCEDURE WITH DEBRANCHING FOR AORTIC ARCH ANEURYSM: JUNE, 1991

Page 8: Doklad 2 presentation

СT scan 10 years after the hybrid procedure

• The position of the endoprosthesis is unchanged/stable

Page 9: Doklad 2 presentation

СT scan 23 years after the hybrid procedure

Page 10: Doklad 2 presentation

Lower end Upper end

СT scan 23 years after the hybrid procedure

Page 11: Doklad 2 presentation

Internal carotid arteries and subclavian arteries

left right

Considerable asymmetry of linear flow velocity is not observed in both internal carotid arteries and in both subclavian arteries

Page 12: Doklad 2 presentation

Vertebral arteries and basilar artery left right basilar

Significant asymmetry in the linear velocity of anterior cerebral arteries is not observed

In both vertebral arteries and in basilar artery blood flow velocity has a value within the age norm

Page 13: Doklad 2 presentation

Autovenous shuntanastomosis with LCCA with LSubA

Abdominal aorta

Page 14: Doklad 2 presentation

Conclusions:• The endoprosthesis has been functioning well for the duration

of the whole time of follow-up – 23 years after hybrid operation.• The system of blood flow created in the result of debranching

provides normal blood flow of the brain and the upper body for the duration of the long time.

• The combined (hybrid) method of endovascular-surgical prosthetic repair of the aorta arch aneurysm in combination with strengthening of the load zone is effective in terms of long-term results.

• The method of a hybrid prosthetic repair of the aorta arch aneurysm, being the most universal one from the point of view of the most complicated anatomical variants of the aorta arch aneurysm, should be perfected with taking into account the newest achievements of endovascular technology, new endoprostheses, new delivery systems for prevention such complications as proximal dissection, stroke etc.

• Taking into account the fact that there are so many anatomical variants of the aorta arch aneurysms, especially in cases with multisegmental thoracic aortic pathologies one can be sure that this method will be in demand as a real clinical practice.