4
CAT3D Radiation Therapy Planning System Pencil Beam convolution/superposition. Collapsed Cones convolution/superposition. Multimodal image registration and fusion. Import Dicom CT, MRI, PET, DicomRT-Struct. Export DicomRT-Plan, Lantis .rtp and .mlc . DVH for up to 16 ROIs simultaneously. DVH cumulative and differential. DVH allows rendering of custom constrains. DRR for static and dynamic fields. Export DRRs as Dicom files. Isodose presentations over axial, coronal, sagittal and oblique planes. Isodose rendering in 3D window. Support for wedges: physical, motorized, EDW and virtual. Optional IMRT planning. Export to solid modulators and Step&Shoot. Support for stereotactic localizers. CAT3D runs under Windows (better 7 to 10). Needs INTEL CPU, I7 or Xeon recommended. CAT3D, developed by Mevis Informática Médica - Brazil

CAT3D brief presentation

Embed Size (px)

Citation preview

CAT3D Radiation Therapy Planning System

• Pencil Beam convolution/superposition.• Collapsed Cones convolution/superposition.• Multimodal image registration and fusion.• Import Dicom CT, MRI, PET, DicomRT-Struct.• Export DicomRT-Plan, Lantis .rtp and .mlc .• DVH for up to 16 ROIs simultaneously.• DVH cumulative and differential.• DVH allows rendering of custom constrains.• DRR for static and dynamic fields. • Export DRRs as Dicom files.• Isodose presentations over axial, coronal,

sagittal and oblique planes.• Isodose rendering in 3D window.• Support for wedges: physical, motorized,

EDW and virtual.• Optional IMRT planning. Export to solid

modulators and Step&Shoot.• Support for stereotactic localizers.• CAT3D runs under Windows (better 7 to 10).• Needs INTEL CPU, I7 or Xeon recommended.

CAT3D, developed by Mevis Informática Médica - Brazil

CAT3D Contouring highlights

• Manual drawing using mouse or tablet pen.

• Autosegmentation for high contrast borders.

• Paintbrush contouring.• Slice-to-slice interpolation.• ROI add, subtract, translation.

• Create contours from isodoses.• ROI (volume) expansion

isotropic, anisotropic, with gap to skin.

• Import ROIs from registered image sets.

• Bifurcated ROIs

CAT3D Planning highlights

• Multiple dose algorithm: Pencil Beam and Collapsed Cones.• Heterogeneity corrections based on voxel density. Easy to modify

electron density table for each CT.• Support for beam modifiers like individual blocks and compensating

filters.• Templates of fields for standard plan configuration.• Isodose presentation over axial, coronal, sagittal and oblique planes.• Isodose surface rendering on 3D window.• Support for physical and virtual wedges. Motorized and fixed wedges.• Support for Varian EDW and Siemens Virtual Wedge.• Add dose from up to eight plans or phases. DVH for multiple phase

plans.• Calculation of Monitor Units (MU) or treatment time (min or seconds).• Local or network patients data base. Data base can be shared between

several CAT3D workstations.• Plan export can be configured to Mosaic, Therapist, ARIA, Lantis and

others.• Work with multiple plans simultaneously in one workstation, in

parallel. Unlimited instances of CAT3D under Windows, only limited by RAM memory.

CAT3D, developed by Mevis Informática Médica - Brazil