Muhammed Nazeer MS,FRCS
• To learn how absolute stability can be obtained using plates
• To differentiate between plate name and function
• To learn how different types of plate function can produce absolute stability
• To show how to reduce the biological price of rigid fixation using plates
2
3
• Refers to shape or design
• Catalogue name
4
5
• “Surfaces of the fracture do not displace under functional load”
• Can only be achieved by interfragmentary compression
Absolute stability
• A plate by itself rarely provides absolute stability
• The key tool of absolute stability is the lag screw
Compression must sufficiently neutralize all forces[bending, tension, shear and rotation]
6
The surgeon not the designer of the plate determines how a plate will function and how it will be applied
7
• Neutralization[Protection] plate
• Compression plate
• Tension band plate
• Buttress plate
• Bridge plate—relative stability
8
• Reduces torsional and axial forces on interfragmentary compression screw(s)
• Always used with lag screws
• Requires anatomical reduction
9
10
• Requires a transverse or short oblique fracture pattern
• Requires a simple fracture pattern
• Requires perfect plate contouring
11
12
Compression plate:eccentric DC (dynamic compression) hole
Removable device:compression device
Interfragmentary compression by plate
13
14
Axial compression with removable compression device
Metaphysis: plate contoured butslightly less (shorter) than bone,bone is pulled towards plate
Diaphysis: in order to compressOpposite cortex plate must be prebent
15
16
A plate applied to the tension side of a bone so that tension forces on the plate side of the bone are converted to compression forces on the opposite cortex
17
18
• Only works if you have a true tension side
• Only works if opposite cortex is intact
• Converts tension forces to compression forces on opposite cortex
19
20
Absolute stability: tension band principle
In the eccentrically loaded femur the tension side is always lateral.
A plate MUST be placed on convex (tension) side to counteract distraction forces.
However there must also be a medial bony buttress, if missing, the plate will break due to fatigue.
21
Plate on concave side distracts fracture
Absolute stability: tension band principle
22
23
•Resist axial load by applying force at 90 degree to the axis of potential deformity
•Metaphyseal tibial plateau split fractures
24
• Used when the fracture will only displace in one direction
• Only useful in metaphyseal fractures
• Applied so as to resist one deforming force
25
26
27
28
29
Plate may be a reduction tool
30
31
Direct (primary) bone healing without visible, external callus
32
Absolute stabilityonly after rigid fixation withinterfragmentary compression
Internal remodelling replaces dead structures
Fracture gradually disappears
Minimal periosteal callus
Direct (primary) fracture healing
33
Hazards of absolute stability
Too aggressive exposure, periosteal strippingLack of respect for vascularity of all tissuesPoor soft-tissue careToo much metalToo stiff constructSlow healing
Catastrophies
Careful technique interfragmentary compression absolute stability
Errors in technique and principles complications• Delayed healing• Implant failures • Nonunions• Wound complications and infections
34
35
36
• Cortical blood supply damage—potential problem
• Devascularization and transient osteoporosis beneath plate
37
• Change the design of the plate
• Change the surgical technique
38
39
• Plates rely on friction between the plate and bone to achieve stability
• The bone under the plate will always suffer a degree of vascular damage
• The smaller the footprint of the plate the less the damage will be
• Gradual evolution of plate design• Minimize detrimental effects on bone
40
DCP
LC-DCP
PC-Fix
LCP
Preservation of the soft-tissue envelope profoundly affects bone healing
41
• Always preserve soft tissues
• Use the least amount of metal
• Percutaneous approaches
• MIPO (minimally invasive plate osteosynthesis)
42
43
Biological fixation & absolute stability?
• Balance between surgical fracture stabilization and the insult to the biology caused by the technique
• A demanding surgical technique requiring much experience and the correct indications
44
Absolute stability of conventional plating
Biologic damage of surgical dissection and open reduction
Respect for soft-tissue envelope surrounding fractures is essential
45
Caution! Open carefully, intraarticular fracture inside
No returns or second chances
Handlewithcare
46
Fractures requiring anatomical reduction and early functional aftercare
• articular fractures
• forearm fractures: closed/open
Fractures not suited for relative stability
• simple (type A) metaphyseal fracture
•Function of the plate is not the design but the surgeons technique
Utmost care for the vascularity of soft tissues, periosteum, and bone!
Take home message