16
© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved. RELENTLESS PASSION FOR FIREFIGHTER SAFETY Ken Bush Fire Market Manager, Shur-Sales & Marketing

Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

Embed Size (px)

Citation preview

Page 1: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

RELENTLESS PASSION FOR FIREFIGHTER SAFETY

Ken BushFire Market Manager, Shur-Sales & Marketing

Page 2: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

NFPA 1981, 2013 Ed.

Page 3: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

UL Analysis of Changing Residential Fire Dynamics

Larger Homes Open Home Geometrics

Increased Fuel Loads

New Construction Materials

Faster fire propagationShorter time to flashoverRapid changes in fire dynamicsShorter escape timesReduced time to collapse

Changing Fire Dynamics and its Implications

Page 4: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

Do more with less.More fire departments are seeing less fires.

Most departments are doing more training, but

doing less fire related training.

The fire environment has become more dangerous than ever due to synthetic fuel and energy loads.

Page 5: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

• Changing Primary EOSTI (low air alarm) from 25% to 33% HUD – 100%, 75%, 50%, 33%

• EBSS “Buddy Breathing” Standard A universal low-pressure Connection will not be required

• Quick-Connect Regulator Fitting Change To ensure HUD connection

at all times

NFPA 1981, 2013 Edition Face Piece Requirements

Page 6: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

High Heat and Flame Resistance Performance• Soak @ 500°F for 5 minutes • 10 second flame exposure• 6” drop test• System has to stay positive for 24 minutes

following these tests, regardless of the cylinder size

• Breathing rate = 40 L/min @ 24 breaths/min

Radiant heat Resistance Performance• Expose mask to radiant heat load of 15 kW/m2

for 5 min• System has to stay positive for 24 minutes

regardless of the cylinder size• Breathing at 40 L/min @ 24 breaths/min

Flame & Heat Test Requirements

Page 7: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

Mechanical Communication Performance• Mechanical communications is

required• STI = 0.55 @ 1.5 meters• 65 dBC background / pink noise• Must also have any electronic

communications devices attached and powered off during testing

Amplified Communication Performance• Amplifier is still considered accessory• STI = 0.60 @ 1.5 meters• 71 dBC background / pink noise • *71 dBC simulates 3.0 meters

Page 8: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

NFPA 1982, 2013 Edition Changes• NFPA 1982, 2013 Edition

“Standard on Personal Alert Safety Systems for the Fire Service”

• Universal Sounding PASS To have more

consistent alarm sounds on the fire ground

Page 9: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

Scott Safety Air Pak X3 5.5 / 4.5

Page 10: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

41,000

Page 11: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

AirPak X3 5.5 / 4.5• Redundancy of safety

features• Weight management/

enhanced backpack design• New shoulder strap

configuration• External HUD • Streamlined design• Console design – large

sweep gauge• Buddy lights

Page 12: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

• 30’ Cylinder 1200L

• Small package almost a 10% reduction in weight!

• 45’ Cylinder 1800L

• .7 lb reduction in weight.

• 2” reduction in height

• Similar to a 4.5 – 30 min.

• 60’ Cylinder 2400 L

• 4500 PSI 45 minute package.

• 1.15 lb. reduction in weight.

• .5” in reduction in cylinder diameter

• 75’ Cylinder 3000L

• An industry first• Only .25 inch longer than a 4.5 – 60 min.

5500 PSI Cylinders

Page 13: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

• Backward compatible – Customers can purchase AV-3000 HT and retain NFPA approvals with ‘02 or ‘07 SCBA

• Forward compatible – Customers can purchase AV-3000 HT face pieces now for use with their ‘02 or ‘07 SCBA, and upgrade to 2013 Ed. SCBA later

AV-3000 SS HT Face Piece

Page 14: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

The Air-Pak® is the only SCBA with two inter-connected redundant pressure reducers.

• Developed with NASA in 1976 with no reported complete failures to date

• A reduction in primary pressure triggers an automatic transfer to the back up reducer to provide the user an uninterrupted air flow.

• The Vibralert® will activate, alerting the user to go to a safe breathing area.

“Two In One”

Redundant

Dual Path Redundant Pressure Reducer

Page 15: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

FDIC 2015 Celebrating Innovation

Page 16: Scott Safety Summit - NFPA 1981, 2013 Ed. + X3 5.5 / 4.5 Air Paks

PHONE: 303.789.5696 | EMAIL: [email protected] | WEB: www.shur-sales.com

© 2015 Shur-Sales & Marketing. Proprietary and Confidential. All Rights Reserved.

THANK YOU