Portable / Temporary Fire Hall Example
2 Apparatus Bay with Optional Accommodation Unit
Sketches are for illustration and discussion purposes. Dimensions are approximate.
End Elevation at Apparatus Bays End Elevation at Barracks
Side Elevation
Portable / Temporary Fire Hall Example
2 Apparatus Bay with Optional Accommodation Unit
Sketches are for illustration and discussion purposes. Dimensions are approximate.
Suggested Floor Plan
7’-10” 36’-2” 7’-10” 15’-7.25” 5’-11”
51’-10” 21’- 6.25”
73’- 4.25” 5
’-1
1”
15
’-7
.25
”
1
5’-
7.2
5”
5’-
11
”
43
’-9
”
2’-
10
”
41
’-1
0”
Apparatus Bays Main Floor – Barracks Mezzanine Floor - Barracks
Kitchen /
Dining
Lounge
Exercise Area
Sleeping Quarters
Portable / Temporary Fire Hall Example
2 Apparatus Bay with Optional Accommodation Unit
Sketches are for illustration and discussion purposes. Dimensions are approximate.
Isometric – Building Orientation
Apparatus Bay 1 Apparatus Bay 2 2 Story Barracks
O4H Unit 1 O4H Unit 2 O4H Unit 3
Portable / Temporary Fire Hall Example
2 Apparatus Bay with Optional Accommodation Unit
Sketches are for illustration and discussion purposes. Dimensions are approximate.
Budget costing (USD)
Apparatus Bays +/- $390,000 per bay.
Optional Accommodation Unit +/- $410,000.
Shipping costs will vary with location.
Manufacturing time approximately 14 weeks. Quotations available on request. Leasing / Rental Options Available
Portable / Temporary Fire Hall Example
2 Apparatus Bay with Optional Accommodation Unit
Sketches are for illustration and discussion purposes. Dimensions are approximate.
NOTES
• No foundations are required—any level stable ground is suitable. No Building permits.
• The units are completely portable and reusable. Set up / take down time is +/- 2 hours. The project as recommended includes 2 - One4Haul
Ultimate Portable Buildings, site connected. The units can be disconnected and used separately in a future applications if required.
• The units are prewired, plumbed and insulated including light fixtures and HVAC. (NEMA 4 wiring suitable for wet service conditions) Set up /
take down is hydraulically automated. They can be connected to domestic or portable power supply. Exhaust ventilation systems included.
Sprinkler systems available.
• Non-combustible construction. (Steel siding over structural steel and aluminum framing)
• A 1500 gallon integral waste containment tank is built into the floor below the self-draining drive surface.
• Low maintenance and high resale value.
• Built to meet all applicable codes. Manufacturing time is approximately 14 weeks.