35
Trickling Filters* Sanitary Engineering CWS-presentation Trickling Filters 1 Submitted By Prakhar Deroliya, 2013UCE149 Purkha Ram, 2014UCE1247 K. Anirudh, 2014UCE1376 Rishabh Srivastava, 2014UCE1 SUBMITTED TO Prof A. B. Gupta

Trickling Filters

Embed Size (px)

Citation preview

Page 1: Trickling Filters

Trickling Filters*Sanitary EngineeringCWS-presentation

Submitted ByPrakhar Deroliya, 2013UCE1492Purkha Ram, 2014UCE1247K. Anirudh, 2014UCE1376Rishabh Srivastava, 2014UCE1300

SUBMITTED TO Prof A. B. Gupta

Page 2: Trickling Filters

INDEX 1. Introduction2. Classification and Design criteria3. Basic flow diagrams 4. Empirical equations 5. Operational Problems 6. Advantages and disadvantages 7. References

Page 3: Trickling Filters

INTRODUCTION • Whereas Activated Sludge

Process (ASP) is a “suspended growth” process, Trickling Filters* (TFs) and its variants i.e. Rotatory Biological Contractors (RBCs) are “attached growth” processes. • In a typical TF, wastewater trickles

over medium. • Bacteria grow on medium, thus

creating Biofilm.

Page 4: Trickling Filters

INTRODUCTION (CONTD.)• Trickling filters are conventional aerobic

biological wastewater treatment units. • A typical TF consists of a cylindrical tank and is

filled with a high specific surface area material, such as rocks, gravel, shredded PVC bottles, or special pre-formed plastic filter media.

• A high specific surface provides a large area for biofilm formation.

• Organisms that grow in the biofilm over the surface of the media oxidize the organic load in the wastewater to CO2 and water, which generating new biomass.

• The incoming pre-treated wastewater is trickled over the filter with the use of rotatory sprinkler.

Page 5: Trickling Filters

INTRODUCTION (CONTD.)• In this way, the filter media goes through cycles of being dosed and exposed to air. • However, oxygen is depleted within the biomass and the inner layers may be

anoxic or anaerobic. • The properties of an ideal material for trickling filter are:

• Low cost• Durable • High surface to volume ratio• Light• Allows air to circulate

• Generally used filter media are gravels, corrugated plastic sheets or hollow plastic cylinders.

Page 6: Trickling Filters

INTRODUCTION (CONTD.)• Adequate air flow is important to

ensure sufficient treatment, performance and prevent odors. • Rotary sprinkler/distributor is most

often used which consists of a hollow vertical centre column carrying two or more radial pipes or arms. • Each arm(radial pipe) contains a

number of nozzles or orifices for discharging the wastewater onto the bed.

Page 7: Trickling Filters

INTRODUCTION (CONTD.)• The underdrains should provide a passageway for air at the maximum

filling rate. • A perforated slab supports the bottom of the filter, allowing the

effluent and excess sludge to be collected. • TFs are usually designed with a recirculation pattern for the effluent to

improve wetting and flushing of the filter material. • Due to anaerobic condition, sloughing1 takes place. Microbes fall off

the medium and are carried with the effluent. The under-drain system allows transporting these solid to a clarifier, where the solids settle and separate from the treated effluent.

Page 8: Trickling Filters

BASIC DEFINITIONS • Biofilm layer: The layer of

microorganisms developed on the filter medium due to aerobic utilization of substrate, typically 10 micron to 10 mm thick. • Diffusion layer or stagnant boundary

layer: The layer separating biofilm and moving liquid. • Anaerobic/endogenous zone: The

zone in which oxygen cannot penetrate and hence anaerobic conditions prevail.

Page 9: Trickling Filters

SUBSTRATE CONCENTRATION (CONTD.)

Page 10: Trickling Filters

Trickling Filters 10

SUBSTRATE CONCENTRATION (CONTD.)

• Rate of substrate flux across boundary layer: ) where:rsf = rate of substrate surface fluxDw=molecular diffusion co-efficient for substrate in water Sb=substrate concentration in bulk liquid Ss=substrate concentration at biofilm surface dS/dX=substrate concentration gradient

• Within biofilm, rate of movement

where: rbf= rate of substrate flux De=effective molecular diffusion coefficient in biofilm (De< Dw)

Page 11: Trickling Filters

Trickling Filters 11

Page 12: Trickling Filters

Trickling Filters 12

SUBSTRATE CONCENTRATION (CONTD.)

• Substrate utilization rate:

• Mass balance for biofilm under steady-state: -=0

or De= ……………………………………………………………………..(1)

Page 13: Trickling Filters

Trickling Filters 13

SUBSTRATE CONCENTRATION (CONTD.)

• In equation (1), if we assume S<<ks (i.e. low concentration)• Then the equation gives the following expression • S=Ss )………………………………………………………………………(2)where = sqrt(DeksY/µmaxX)

• Based on and Lf we can classify biofilms in two categories• When Lf> biofilm-substrate does not penetrate far • When Lf< , biofilm is a fully penetrated biofilm

Page 14: Trickling Filters

Trickling Filters 14

DEEP VERSUS SHALLOW BIOFILM

Page 15: Trickling Filters

Trickling Filters 15

BIOMASS KINETICS • Mass balance within the biofilm

maxSf/(Sf+ks)Xfdz - klossXfdz……………………………………………..(3)where dz=unit thickness of biofilm Sf= substrate concentration within biofilm Xf= biomass concentration within biofilm kloss= overall loss rate for biofilm

• Biofilm lose mass constantly by erosion of small pieces and sloughing of large sections

Page 16: Trickling Filters

Trickling Filters 16

BIOMASS KINETICS • Equation (3) can be integrated

over full thickness of biofilm and set to steady-state conditions to get, with substitutes we get the following expression.

XfLf=JY/kloss

or Lf= JY/Xfkloss

Page 17: Trickling Filters

Trickling Filters 17

BIOMASS KINETICS • Sb(minimum)= • When Sb < Sb(minimum), there is no biofilm. • When Sb >> Sb(minimum), biofilm is deep

Page 18: Trickling Filters

CLASSIFICATION OF TFS• Based on organic loadings• Low rate or standard rate trickling

filters: 0.08 to 0.30 kg BOD(5)/cum-day• High rate trickling filters: 0.5 to 1.0

kg BOD(5)/cum-day• Super rate trickling filters: 1-2 kg

BOD(5)/cum-day

• Based on the number of units used in series• Single-stage trickling filter • Two-stage trickling filter

Page 19: Trickling Filters

DESIGN CRITERIA Design Criteria Standard Rate or low

rate TFHigh rate TF (stone media)

Super rate TF (plastic media)

Hydraulic loading (m3/m2-d)

1-4 10-40a 40-200

Organic loading (BOD5 kg/d-m3)

0.08-0.35 0.35-2.4b 1-6

Depth of filter (m) 1.5-3.0 1.0-2.0 2-12Recirculation ratio, R 0.0 1-4 1-14BOD5 removal efficiency (%)

80-85 65-80 65-85

a including recirculation b excluding recirculation Adopted from Wastewater treatment: concept and design approach by Kari and Christian

Page 20: Trickling Filters

TYPICAL FLOW DIAGRAMS (LOW RATE, SINGLE-STAGE TRICKLING FILTERS WITHOUT RECIRCULATION)

Primary Settling Tank Trickling Filter Secondary Settling Tank

Influent Effluent

Page 21: Trickling Filters

HIGH RATE SINGLE STAGE TFS WITH EFFLUENT RECIRCULATION

PST

PST

PST

TF

TF

TF

SST

SST

SST

IN

IN

IN OUT

OUT

OUT

Page 22: Trickling Filters

BASIC DESIGN EQUATIONS • National Research Council Equation (NRC-Equation)• For a low rate or single-stage TF• For a high rate or two-stage TF• Modified National Research Council Equation

• Eckenfelder Equation • Without circulation • With circulation

• Velz Equation • Without circulation • With circulation

Page 23: Trickling Filters

NRC EQUATION • For a low rate or single stage TF

E1=

• For a high rate or two-stage TF

E2=

• Recirculation factor can be calculated using the following formula

F=

Here E1=BOD removal efficiency of the filter of a single-stage TF system or first filter of two-stage TF system in %E2=BOD removal efficiency of the second filter of two-stage TF system in %W1=BOD loading of settled influent to the filter of a single-stage TF system or first filter of a two-stage TF system, kg BOD(5) per dayW2=BOD loading to second filter of a two-stage TF system, kg BOD(5) per dayV1=volume of second filter of a two-stage TF system, cum F1= recirculation factor for first stage filterF2= recirculation factor for second stage filter f=treatability factor which can be assumed as 0.9 for domestic wastewater

Page 24: Trickling Filters

ECKENFELDER EQUATION • Without recirculation

• With recirculation

Sa is given by

Sa=

here Se=effluent substrate concentration, BOD-5, mg/LS0=influent substrate concentration, BOD-5 mg/LSa=substrate concentration of influent and recycled flow, BOD-5, mg/Lk= treatability or waste removal constant (depends on type of wastewater and filter media and usually varies from 0.01 to 1 per minute n= empirical or filter media constant (usually assumed 0.5)Q= hydraulic loading rate cum/sqm-minR= recirculation ratio

Page 25: Trickling Filters

VELZ EQUATION • Without circulation

=10-kD

• With circulation =10-kD

where Ca is given by Ca=

HereCD=concentration removal of BOD remaining at depth D, mg/LC=concentration removal of applied BOD of influent, mg/LCa=concentration of total applied BOD of influent and recycled flow, mg/LCi=concentration of influent BOD excluding BOD excluding recirculation, mg/LCe=effluent BOD, mg/Lk=Bod removable rate constant, per day D=depth of filter media, meters

Page 26: Trickling Filters

OPERATIONAL PROBLEMS• Disagreeable Odours from Filter • Ponding on Filter Media• Filter Files (Psychoda) • Icing • Rotating Distributor Slows Down or Stops

Page 27: Trickling Filters

DISAGREEABLE ODOURS FROM FILTER

• Potential Cause: Excessive organic load causing anaerobic decomposition in filter. • Remedy: Reduce loading; increase BOD removal in primary settling tanks;

enhance aerobic conditions in treatment units by adding chemical oxidants, pre-aerating, recycling plant effluent, or increasing air to aerated grit chambers; use plastic media instead of rock • Potential Cause: Inadequate ventilation • Remedy: Increase hydraulic loading to wash out excess biological growth;

remove debris from filter effluent channels, underdrains, and the top of filter media; unclog vent pipes; reduce hydraulic loading rates if underdrains are flooded; install fans to induce draft through filters

Page 28: Trickling Filters

PONDING ON FILTER MEDIA• Potential Cause: Excessive biological growth or foreign matter in or on

the filter • Remedy: Reduce organic loading; increase hydraulic loading to

increase sloughing; use high-pressure stream of water to flush filter surface; maintain 1-2 mg/L residual chlorine on the filter for several hours; flood filter for 24 hours; shut down filter to dray out media; replace media if necessary; remove debris.

Page 29: Trickling Filters

FILTER FLIES (PSYCHODA)• Potential Cause: Inadequate filter media moisture • Remedy: Increase hydraulic loading; unplug spray orifices or nozzles;

use orifice opening at end of rotating distributor arms to spray filter walls; flood filter for several hours each week during fly season; maintain 1-2 mg/L residual chlorine on the filter for several hours • Potential Cause: Poor housekeeping • Remedy: Mow area surrounding filter and remove weeds and shrubs.

Page 30: Trickling Filters

ICING • Potential Cause: Low temperature of wastewater • Remedy: Decrease recirculation; use high-pressure stream of water to

remove ice from orifices, nozzles, and distributor arms; reduce number of filters in service as long as effluent limits can still be met; reduce retention time in pre-treatment and primary treatment units; construct windbreak or covers

Page 31: Trickling Filters

ROTATING DISTRIBUTOR SLOWS DOWN OR STOPS

• Potential Cause: Insufficient flow to turn distributor. • Remedy: Increase hydraulic loading • Potential Cause: Clogged arms or orifices • Remedy: Flush out arms by opening end plates; remove solids from influent

wastewater; flush out orifices • Potential Cause: Clogged distributor arm vent pipe• Remedy: Remove material from vent pipe by rodding or flushing; remove

solids from influent wastewater • Potential Cause: Distributor arms not level and Distributing rods hitting media • Remedy: Level Media; remove some media

Page 32: Trickling Filters

ADVANTAGES• Less energy needed (Natural aeration)• Simpler operation • No bulking sludge problem • Better sludge thickening • Can withstand varied loading • Suitable in areas where ASP cannot be installed. • Less skilled person and technical expertise required. • Less wear and tear, thus low operation and maintenance cost

Page 33: Trickling Filters

DISADVANTAGES • Poorer effluent quality, hence additional treatment may be required• Sensitive to low temperature • Produces odors • Sloughing events can create lots of sludge in short time • Filter files • Nitrogen removal is difficult • Limited flexibility and control as comparison with ASP.

Page 34: Trickling Filters

LIST OF REFERENCES • www.sswm.com/trickling-filters• Trickling Filter Fly Control, M. Livingston Vol.23, No.2 • NPTEL • Trickling Filter Achieving Nitrification, ETI • www.Wikipedia.com • Rittman and McCarly for biofilm modelling.

Page 35: Trickling Filters

Save water.