30
A PRACTICAL TRAINING SEMINAR ON PRESENTED BY: MUKESH KUMAR VII SEM. (ELECTRICAL ENGG 11ESKEE066 SURATGARH SUPER THERMAL POWER STATION SUBMITTED TO Mrs. RIDA QURESHI Mr. MANISH NAULAKHA

suratgarh thermal power station by mk yadav

Embed Size (px)

DESCRIPTION

training presentation on sstps

Citation preview

Page 1: suratgarh thermal power station by mk yadav

A PRACTICAL TRAINING SEMINAR ON

PRESENTED BY:MUKESH KUMARVII SEM. (ELECTRICAL ENGG.)11ESKEE066

SURATGARH SUPER THERMAL POWER STATION

SUBMITTED TOMrs. RIDA QURESHIMr. MANISH NAULAKHA

Page 2: suratgarh thermal power station by mk yadav

1. Introduction2. Land3. Water conducting system4. Block diagram of thermal power plant5. Boiler6. Economizer7. Super heater and Reheaters8. Air preheaters9. Turbines10. Condenser11. Coal and ash handling plants12. Generator

CONTENTS

Page 3: suratgarh thermal power station by mk yadav

Introduction

1. Suratgarh thermal power station is the first super thermal power Station of Rajasthan with total installed capacity of 1500 MW.

2. Suratgarh super thermal power station is located 27 km away from Suratgarh town in Ganganagar Dist. on the left bank of IGNP at Up Stream of Suratgarh Barrage.

3.This station is operated and maintained by Rajasthan Vidhyut Utpadan Nigam Limited.

Page 4: suratgarh thermal power station by mk yadav

S.S.T.P.S. is designed in six stages•STAGE I - 1x250 MW•STAGE II - 1X250 MW•STAGE III - 1X250 MW•STAGE IV - 1X250 MW•STAGE V 1X250 MW•STAGE VI - 1X250 MW•STAGE VII- 1X660MW(Under construction)•STAGE VIII- 1X660MW(Under construction)Total Power Generation - 1500 MW

Page 5: suratgarh thermal power station by mk yadav

LAND :Total Land 5020 BIGHAPlant Area 3810 BIGHAColony Area 431 BIGHARailway Site 425 BIGHAWater conducting 354 BIGHAsystem

Page 6: suratgarh thermal power station by mk yadav

WATER CONDUCTING SYSTEM:

a) Length of Intake Canal = 1.6 Km

b) Capacity of each Decilting Pump = 3.14 Kw*3(30M³/Hr.)

c) Intake Pump House = 90 Kw*6(1250M³/Hr.)Each Pump

d) Raw Water Pump House = 7 lacks M³

Page 7: suratgarh thermal power station by mk yadav

BLOCK DIAGRAM OF THERMAL POWER PLANT

Page 8: suratgarh thermal power station by mk yadav

BOILER

Page 9: suratgarh thermal power station by mk yadav

BOILER PARAMETERS:-

•Height of boiler 60 meters•Height of chimeny 220 meters•Foundation depth 8.5 meters•Furnace Depth 11506 meters•Furnace Width 15.240 meters•Total Water Flow 780.5 T/Hr.•Steam Flow 740.8 T/Hr.•Steam Temperature 540ºC•Coal Requirement for 250MW 160 T/Hr.•Primary Air for pulverized fuel 268.4 T/Hr.•Secondary Air for ignition (Combination) 647.0 T/Hr.•Total Air 915.5 T/Hr.•Steam Pressure 156 Kg /cm²

Page 10: suratgarh thermal power station by mk yadav

• Flue gases coming out of the boiler carry lot of heat. An economizer extracts a part of this heat from flue gases and uses it for heating feed water. This use of economizer results in saving coal consumption and higher boiler efficiency

Economizer

Page 11: suratgarh thermal power station by mk yadav

• Super heater :

• Super heater is a component of a steam-generating unit in which steam, after it has left the boiler drum, is heated above its saturation temperature

• Reheater : Some of the heat of superheated steam is used to rotate the turbine where it loses some of its energy

Super heater and Reheaters

Page 12: suratgarh thermal power station by mk yadav

• After flue gases leave economizer, some further heat can be extracted from them and used to heat incoming heat. Cooling of flue gases by 20 degree centigrade increases the plant efficiency by 1%.

• Air preheaters may be of three types Plate type Tubular type Regenerative type

Air preheaters

Page 13: suratgarh thermal power station by mk yadav

TURBINE

.

In a Thermal Power Plant generally 3 turbines are used to increase the efficiency.

High Pressure Turbine(HPT): The superheated steam is directly fed to this turbine to rotate it.

Intermediate Pressure Turbine(IPT): The out put from the HPT is reheated In a reheated(RH) and used to rotate IPT .

Low Pressure Turbine(LPT): The Exhausted steam from the IPT is directly fed to rotate the shaft of LPT.

HPT IPT LPT

RH

Steam

Steam

Shaft

Super Heater

Condenser

GeneratorHPT IPT LPT

Page 14: suratgarh thermal power station by mk yadav

High pressure turbine: The HP turbine consists of 25 reaction stages. The moving and stationary blades are inserted into appropriately shapes into inner casing and the shaft.Intermediate pressure turbine: The steam from HP turbine after reheating enters the inner casing from above and below through two inlet nozzles. The IP turbine consists of 20 reaction stages per flow. The moving and stationary blades are inserted in appropriately shaped grooves in shaft and inner casing.Low pressure turbine: Steam admitted to LP turbine from IP turbine flows into the inner casing from both sides through steam inlet nozzles.

Page 15: suratgarh thermal power station by mk yadav

HP turbine having 25 Blades & Single flow.IP turbine having 17 Blades & Single flow.LP turbine having 8 Blades& Double flow.

TURBINE SPECIFICATION

Inlet/Outlet Pressure And Temperature1. H P Turbine Steam Inlet/outlet pressure -150 Kg/Cm²/39.69 Kg/Cm²

A inlet/outlet Temperature - 537*C/346*C2 . I P Turbine Steam Inlet pressure - 35.64 Kg/Cm² a. Outlet pressure - 6.83 Kg/Cm² b.Exhaust Temp. - 305*C 3. LP Turbine Steam Inlet pressure - 6.83 Kg/Cm² a.Exhaust Temp. - 49*C

Page 16: suratgarh thermal power station by mk yadav

MOVING BLADES

Page 17: suratgarh thermal power station by mk yadav

Inlet Guide Vanes

Page 18: suratgarh thermal power station by mk yadav

FIXED BLADES

Page 19: suratgarh thermal power station by mk yadav

Rotor Layout

Page 20: suratgarh thermal power station by mk yadav

CONDENSERThe condenser does the job of condensing the steam exhausted from turbine.

Steam after rotating steam turbine comes to condenser. Condenser refers here to the shell and tube heat exchanger (or surface condenser) installed at the outlet of every steam turbine in Thermal power stations of utility companies generally.

Page 21: suratgarh thermal power station by mk yadav

In S.S.T.P.S. surface condenser is used. A surface condenser consists of an airtight cylindrical shell having a chamber at each end. Water tube extends between the chambers. The shell is made of welded steel plate construction and the tubes are made of copper zinc alloy. Cooling water flow through the tubes. The steam is admitted from the top and gets condensed due to contact with the tube surface. The condensate leaves from the bottom. For efficient operation, the temperature rise in the cooling water passing through the condenser should be around 10degree C.

Condenser Used In S.S.T.P.S.

Page 22: suratgarh thermal power station by mk yadav

1. COAL HANDLING PLANT (CHP)

COAL & ASH HANDLIG PLANT

The function of CHP is automatic feeding of coal to the boiler furnace. The coal is transported to the power station by rail. One rail (rack) consists of 58 or 59 boxes with 60 – 70 tones coal loaded in each box. There are 6-7 racks of coal are used.About 18000 tonnes coal required per day for whole unit.

Page 23: suratgarh thermal power station by mk yadav

The main equipments of CHP are:

1. Wagon trippler: - A tripler is a equipment that is used for unloading the coal from box by lifting and tilting the box.

2. Side arm charger: - It is used for pushing or carrying the loaded or empty boxes.

3. Conveyors: - Different sized and diff. Capacity conveyors are installed for feeding the coal from Tripler to bunkers.

4. Crusher: - Crushers are provided for crushing the coal in desired sizes.5. Primary crusher : 26. Secondary crusher : 87. Stacker cum re-claimer : 28. Stacker/Reclaimer: - The stored coal is stacked or reclaimed by the

stacker/reclaimer.9. Bunkers: - Crushed coal is led to the mills via canonical shaped bunkers.10.Coal feeders: - Coal feeder delivers the coal from the bunkers to the mill.11. Pulverization of coal:- Pulverizing mills In modern TPS’s coal is

pulverized i.e. ground to dust likesize. Pulverization is a means of exposing a large surface area to the action oxygen and consequently helping the combustion. mill used for one unit in which one standby. Mill is 4.7met in dia. &7.2 met in length.

Page 24: suratgarh thermal power station by mk yadav

Overview of coal handling plant Raw coal from bharat coal

ltd. Dhanbad & bilaspur(MP)

To SSTPS from gudla via a single railway track

Wagon tippler

hoppersCrusher housebunkers

Raw coal feeders

Coal mills(pulverization)

Boiler furnace ( tangential firing of pulverized coal)

Page 25: suratgarh thermal power station by mk yadav

Useful Heat Value Of Different Grade Of Coal.

GRADE U.H.V

A >6200 Kcal/kg

B 5600-6200 kcal/kg

C 4940-5600 kcal/kg

D 4200-4940 kcal/kg

E 3360-4200 kcal/kg

F 2400-3360 kcal/kg U.H.V = 8900-138[A+M] Where A=% of ash M =% Inherent moisture

Page 26: suratgarh thermal power station by mk yadav

2. ASH HANDLING PLANT (AHP)

Coal contains a considerable amount of ash. The percentage of ash in the coal varies from about 5% in good quality coals to about 40% in poor quality coals. Generally poor quality coal is used in steam power plant, so the plant produces hundred tones of ash daily. For removal of ash from the boilers and its disposal to the suitable site is quite difficult. Ash handling comprises the following operation: 1. Removal of ash from the furnace ash hoppers.2. Transfer of ash to a fill or storage3. Disposal of stored ash.

Page 27: suratgarh thermal power station by mk yadav

In S.S.T.P.S. Hydraulic System Is Used For Ash Handling.

Hydraulic system:

In this system stream of water carries ash along with it in a Closed channel and disposes it of to the proper site. This is the healthy clean dustless and completely enclosed system.

In this system the hoppers below the boilers are fitted with water nozzles both at the top and on sides. The top nozzles quench the ash while the side ones provides the driving force for the ash. The ash and water then flow along a trough to a receiving hopper or sump where the ash is separated from the water. The water is used again while the ash is sent out through the carriages.

Page 28: suratgarh thermal power station by mk yadav

TWO POLE TYPE; WITH CYLINDRICAL ROTOR BASIC PRINCIPLE :FARADAY’s LOW OF MAGNETIC

INDUCTION

COOLING: STATOR WINDING-DIRECT WATER COOLING ROTOR WINDING – HYDROGEN COOLING

GENERATOR:

GENERATORMECHANICAL ENERGY

ELECTRICAL ENERGY

Page 29: suratgarh thermal power station by mk yadav

The Synchronous Generator is used to Generate power by connecting the shaft of the Turbine to the shaft of the generator which cuts the magnetic flux producing Emf.

• The Generated Voltage will generally 11KV to 20 KV max.• The Generated Voltage is stepped up by connecting Step up

transformer and is transmitted and is also used for Auxiliary purposes.

Generator

Bus Duct

Generator Transformer20KV to 400KV

SYNCHRONOUSGENERATOR

UAT20Kv to 6.KV

Unit Auxiliary Transformer: This transformer is used to step down the produced voltage and use for Auxiliary purpose.

Page 30: suratgarh thermal power station by mk yadav