eColor Cove EC PowercoreCost-effective linear interior LED cove and accent fixture with solid color light
eColor Cove EC Powercore Product Guide2
eColor Cove EC Powercore Cost-effective linear interior LED cove and accent fixture with solid color light
• IntegratespatentedPowercoretechnology—Powercorerapidly,efficiently,andaccuratelycontrolspoweroutputtofixturesdirectlyfromlinevoltage,eliminatingtheneedforanexternalpowersupply.Contractor-friendlyinstallationdramaticallysimplifiesinstallationandlowerstotalsystemcost.
• Supportformultiplevoltages—eColorCoveECPowercoreacceptspowerinputof100,120,or220–240VAC,allowingconsistentinstallationinanylocationaroundtheworld.
• Smoothdimmingcapability—PatentedDIMandtechnologyofferssmoothdimmingcapabilitywithselectedcommerciallyavailablereverse-phaseELV-typedimmers.
• Easyinstallation—Powercoredeliverslinevoltagedirectlytothefixtures,simplifyinginstallationbyeliminatingtheneedforexternalpowersuppliesandallowinglongproductruns.Easy-to-install4ft(1.2m)mountingtracksallowquickprojectsetupinlinearapplications.
• Flexiblemountingandpositioning—Withend-to-endlockingpowerconnectorsthatcanmake180ºturns,eColorCoveECPowercorefixturesareeasytopositionineventhemostchallengingmountingcircumstances.Fixturesrotatein10°incrementsthroughafull180°forpreciseaimingandbeammixing.Optionalmountingtrackssupportverticalandoverheadpositioning.1ft(305mm)and5ft(1.5m)jumpercablescanaddextraspacebetweenfixtures.
eColorCoveECPowercoreisadimmable,linearLEDfixturethatprovidesanaffordable,energy-efficientlightinginapplicationsrequiringsaturatedblueoramberlight.Withitslowprofile,rotatinghousing,andend-to-endlockingpowerconnectors,eColorCoveECPowercoreistheperfectchoiceforawiderangeofinteriorretail,exhibit,hospitality,andarchitecturalsettings.
Compact and flexibleeColorCoveECPowercorelow-profilefixturesfitinnarrowalcoves,displaycases,lightboxes,andothertightspaceswherelightsourcesrequiringballasts,externalpowersupplies,andotherauxiliaryequipmentcannot.
eColor Cove EC Powercore Product Guide 3
SpecificationsDuetocontinuousimprovementsandinnovations,specificationsmaychangewithoutnotice.
110º
10º
110º
180º
5.6 in(142 mm)
5.1 in(130 mm)
6 in(152 mm)
7.6 in(193 mm)
12 in(305 mm)
8.1 in(206 mm)
1.4 in(35 mm)
1.2 in(30 mm)
1 in(25 mm)
120V 120V
120V120V
E To calculate the number of fixtures your specific installation can support, download the Configuration Calculator from www.philipscolorkinetics.com/support/install_tool/
* Refertowww.philipscolorkinetics.com/support/appnotes/forspecificdetails.†Fixturesinstalledend-to-end,20Acircuit,standard10ft(3.1m)LeaderCable.Thesefigures,providedasaguideline,areaccurateforthisconfigurationonly.Changingtheconfigurationcanaffectthefixturerunlengths.
.875 in(22.2 mm)
1.75 in(44.5 mm)
1.25 in(31.8 mm)
4.375 in(111.1 mm)1.75 in
(44.5 mm)
UL/cULWiringCompartment
E For help estimating the light output and distribution of eColor lighting fixtures, please contact Philips Color Kinetics Applications Engineering Services at [email protected].
Item Specification 6in(152mm) 12in(305mm)
Output BeamAngle 110°x110°
Electrical
InputVoltage 120VAC,50/60Hz 100/120/220–240VAC,50/60Hz
PowerConsumption 1.5Wmaximumatfulloutput,steadystate
3.0Wmaximumatfulloutput,steadystate
PowerFactor .96@120VAC
Control Dimming Compatiblewithselectedcommerciallyavailablereverse-phase(ELV-type)dimmers*
Physical
Dimensions(Height x Width x Depth)
1.25x6x1.4in(32x152x35mm)
1.25x12x1.4in(32x305x35mm)
Weight 0.19lbs(85g) 0.31lbs(142g)
Housing Injection-moldedplastic,dark-grayfinish
Lens Clearpolycarbonate
FixtureConnections Integralmale/femaleconnectors
TemperatureRanges-4°–122°F (-20°–50°C)Operating-4°–122°F (-20°–50°C)Startup-40°–176°F(-40°–80°C)Storage
Humidity 0–95%,non-condensing
MaximumFixtureRunLengths† 191@120VAC
122@100VAC134@120VAC191@240VAC
CertificationandSafety
Certification UL/cUL,FCCClassB,CE,CCC,C-Tick,SAA
Environment DryLocation,IP20
EnergyEfficiency CaliforniaTitle24Compliant
eColor Cove EC Powercore Product Guide4
Product Selection ToordereColorCoveECPowercore,selectafixturecolor,alinevoltageconnectionoption,afixturelength(120VAConly),andanyextraoptionsyoumightneed.
Item Type Size ItemNumber Philips12NC
eColorCoveECPowercore,100VAC
Blue 12in(305mm) 223-000004-70 910503701081
Amber 12in(305mm) 223-000004-71 910503701082
eColorCoveECPowercore,120VAC
Blue6in(152mm) 223-000005-62 910503701085
12in(305mm) 223-000004-62 910503701073
Amber6in(152mm) 223-000005-63 910503701086
12in(305mm) 223-000004-63 910503701074 eColorCoveECPowercorefixtures
eColorCoveECPowercore,220–240VAC/CE
Blue 12in(305mm) 223-000004-66 910503701077
Amber 12in(305mm) 223-000004-67 910503701078
eColorCoveECPowercore,220–240VAC/CCC
Blue 12in(305mm) 223-000004-72 910503701670
Amber 12in(305mm) 223-000004-73 910503701671
LeaderCablewithterminatorandstrainrelief
UL/cUL 10ft(3m) 108-000032-00 910503700586Forconnectiontostandardjunctionbox
CE 10ft(3m) 108-000032-02 910403325901
WiringCompartmentwithterminator UL/cUL 120-000076-00 910503700597
Canbeusedfordirectconnectiontoconduit
LeaderCablewithplug UL/cUL 8ft(2.4m) 108-000032-03 910503700394 Forportableinstallations
JumperCable
UL/cUL1ft(305mm) 108-000033-00 910403600101
Dependingontheinstallation’sdesign,youmayneedjumpercablestoaddspacebetweenfixtures
5ft(1.5m) 108-000033-01 910403600102
CE1ft(305mm) 108-000033-02 910403326001
5ft(1.5m) 108-000033-03 910403326101
MountingTrackMinimum order quantity 25 4ft(1219mm) 523-000006-01 910503700452 Optionalmountingtrack
ensuresstraightrunsoffixtures
UseItemNumberwhenorderinginNorthAmerica.
6 in (152 mm)
12 in (305mm)
Choose length (120 VAC only)
Choose fixture color
Red Green
Choose line voltage connection option
Leader cable
Permanent Installations
Portable Installations
Leader cable
Wiring compartment, UL / cUL
Choose optional accessories
5 ft (1.5 m) Jumper cable
1 ft (305 mm) Jumper cable
Mounting track
4
Blue Amber
Fixtures and Accessories
eColor Cove EC Powercore Product Guide 5
InstallationeColorCoveECPowercoreoffershigh-output,energy-efficientindoorwhiteandsolidcoloralcovelightingwithPowercoretechnology.Powercore,whichdeliverslinevoltagedirectlytothefixture,easesinstallationbyeliminatingtheneedforexternalpowersuppliesorspecialwiring.
Owner / User ResponsibilitiesItistheresponsibilityofthecontractor,installer,purchaser,owner,andusertoinstall,maintain,andoperateeColorCoveECPowercorefixturesinsuchamannerastocomplywithallapplicablecodes,stateandlocallaws,ordinances,andregulations.Consultwiththeappropriateelectricalinspectortoensurecompliance.
Create a Layout Plan Regardlessofthesizeandcomplexityofyourinstallation,thetimeyouspendplanningcanhelpminimizeinstallationandconfigurationissueslater.Keepthesesuggestionsinmindasyouplanyourinstallation:
• Onanarchitecturaldiagramorotherdiagramthatshowsthephysicallayoutoftheinstallation,createalayoutmapthatspecifiestheappropriatelocationofthelightfixturesinrelationtoeachother,andtoanydimmerswitches,wallswitches,andlinepowersources.Identifyanyobstaclesorphysicalfeaturesrequiringflexiblejumpercablesbetweenfixtures.
• Usingthefixture’spowerconsumptionandefficiencyratings,thelightingdesignerorarchitectshouldcalculatethecovedimensionstoensurethatoperatingtemperaturesremainwithinsafelevels.Thedesignerorarchitectshouldalsodeterminethecove’sfasciadesignandfixturesetbackbasedonthecovedimensionsandroomwidth.Westronglyrecommendcreatingdimensionalmodelsandmockupspriortoinstallation.
• eColorCoveECPowercorefixturesareinstalledinseries.Thein-lineconnectorsallowend-to-endfixtureconnectionsforthebestvisualeffects.Wheninstallingfixturesend-to-end,allowaminimumdistanceof.125in(3mm)betweenfixtures,andamaximumdistanceof.625in(16mm).Formorespacingbetweenfixtures,usethe1ft(305mm)or5ft(1.5m)jumpercables.
• YoucaninstallarunofeColorCoveECPowercorefixturesusingthe10ft(3m)LeaderCablewithflyingleads.Thisoptionispreferablewhenconnectingtoathird-partyjunctionbox,orwhenretrofittinganexistingincandescentorfluorescentcovelightinginstallation.
• InNorthAmerica,youcanusetheWiringCompartmentwhenyouwanttorunbranchconduitallthewaytothefirstfixtureinaseries,orwherelocalcodesrequireit.Youcanalsocreateaportableinstallationbyusingthe8ft(2.4m)LeaderCablewithplug.
• Iffixturesareinstalledend-to-endona20Acircuitusingthestandard10ft(3m)LeaderCable,eachruncanaccommodateup19112in(305mm)fixtures.Usingtheoptionaljumpercablescandecreasethenumberoffixturesthatyoucanconnectinasinglerun.
Install Wall and Dimmer Switches (Optional)eColorCoveECPowercorefixturescanbecontrolledeitherwithastandardwallswitch(on/off)oracompatible,commerciallyavailablereverse-phaseELV-typedimmer.
ForalistofcompatibleELVdimmers,andfordetailsonselectingtheappropriatedimmerforyourlightinginstallation,visitwww.philipscolorkinetics.com/support/appnotes,orconsultApplicationsEngineeringservicesatsupport@colorkinetics.com.
Distancebetweenfixtures
EasyturnsEnd-to-endlockingpowerconnectorscanmaketurnsofupto180ºwithoutjumpercables.
5 in(128 mm)
4.5 in(114 mm)
.125 in(3 mm)
.625 in(16 mm)
120V120V
120V120V
IncludedintheboxeColorCoveECPowercorefixtureInstallationInstructions
E Refer to the eW / eColor EC Cove Powercore Installation Instructions for specific warning and caution statements.
E To calculate the number of fixtures your specific installation can support, download the Configuration Calculator from www.philipscolorkinetics.com/support/install_tool/, or consult Philips Color Kinetics Application Engineering Services at [email protected].
E Refer to the installation instructions included with the wall or dimmer switch for installation and wiring information.
eColor Cove EC Powercore Product Guide6
Prepare for the Installation1. Verifythatallsupportingequipment(switches,linepowersources)isinplace.
2. Ifyourinstallationcallsforjumpercablestoaddspacebetweenfixtures,makesuretheyareavailable.
3. Ensurethatalladditionalparts(optionalmountingtracks,mountinghardware,terminators)andtoolsareavailable.
Install the FixturesYoucanmounteColorCoveECPowercorefixturesdirectlytoawall,ceiling,cabinet,orothersecuresurface.YoucaninstallseveraleColorCoveECPowercorefixturesinoptional4ft(1.2m)lengthsofmountingtracktoensureastraightrun.
Install Mounting Tracks (Optional)1. Field-cutthemountingtrackstothedesiredlengthwithahacksawortinsnips.
2. Installthemountingtracksusinghardwaresuitableforthemountingsurface.
Toensureproperfixturefit,hardwaremustnotextendabovethetrackstandoffsafterinstallation.Therecommendedmaximumspacingbetweenscrewsis12in(305mm).
Mount and Connect the FixturesMakesurethepowerisOFFbeforemountingandconnectingeWCoveECPowercorefixtures.
1. RotateaneWCoveECPowercorefixtureasnecessarytoprovideunobstructedaccesstothemountingholes.
2. Positionthefirstfixtureinaseries.
Ifusingmountingtracksonahorizontalsurface,snapthefixtureintothetrack.
Ifusingmountingtracksonverticaloroverheadsurfaces,orifnotusingmountingtracks,attachthefixturewithfour#6(3.5mm)mountingscrews(notincluded)suitableforthemountingsurface.
EnsurethatthemaleconnectorisinpositiontoreceivepowerfromthefemaleconnectorontheLeaderCableorWiringCompartment.
E You can use the fixture base as a template when pre-drilled pilot holes are required. Hold the fixture in place and mark the four screw holes.
OK
eColor Cove EC Powercore Product Guide 7
3. Positionthenextfixtureintheseries,matchingthemaleconnectorendtothefemaleconnectorofthepreviouslymountedfixture.Attachthefixturetothesurfaceorsnapitintothetrack.
4. Continuemountingthefixtures,makingpowerconnectionsasyougo,untilalllightsintheseriesaremounted.
5.Inserttheprovidedterminatorintothelastfixtureintheseries.
Make Power Connections
Torunpowerorconduittothefirstfixtureinaseries(permanent, UL / cUL installations):
1. RemovethecoverfromtheeWCovePowercoreWiringCompartment.
2. Usingwirenuts,connectground,neutral,andlineinsidetheWiringCompartmenthousing,thenreplacethecover.
3. ConnecttheeWCovePowercoreWiringCompartmenttothefirstfixtureintheseries.
CLICK!
Terminator
End-to-End1ft.or5ftJumperCable
.875 in(22.2 mm)
1.75 in(44.5 mm)
1.25 in(31.8 mm)
4.375 in(111.1 mm)1.75 in
(44.5 mm)
UL/cULWiringCompartment
Toconnectthefirstfixtureinaseriestoathird-partyjunctionboxusing the 10 ft (3 m) Leader Cable (permanent installation):
1. Removethecoverofthethird-partyjunctionbox.
2. Connectground,neutral,andlineinsidethejunctionboxhousing,thenreplacethejunctionboxcover.
3. Connectthe10ft(3m)LeaderCabletothefirstfixtureintheseries.
For portable installations (UL / cUL):
1. Plugthe8ft(2.4m)LeaderCableintoasuitableswitchedoutlet.
2. ConnecttheLeaderCabletothefirstfixtureintheseries.
For CE installations:
1. ConnecttheLeaderCabletoaterminalblock.TheterminalblockmustconformtoEN60998-2-1orEN60998-2-2,rated220–240VAC.
2. Connectground,neutral,andlinetoapowersource.
3. ConnecttheLeaderCabletothefirstfixtureintheseries.
Aim the FixturesMakesurethepowerisONbeforeaimingfixtures.
Aimthefixturesbyrotatingeachfixturetothecorrectangle.Therearedetentsevery10°inthebracketthatholdthefixtureinposition.
.375 in(9.5 mm)
.675 in(15.9 mm)
1.13 in(28.6 mm)
1.25 in(31.8 mm)
.375 in(9.5 mm)
.675 in(15.9 mm)
1.13 in(28.6 mm)
1.25 in(31.8 mm)
LeaderCableconnectordimensions
110º
10º
110º
180º
Philips Color Kinetics3 Burlington Woods DriveBurlington, Massachusetts 01803 USATel 888.385.5742Tel 617.423.9999Fax 617.423.9998www.philipscolorkinetics.com
Copyright © 2011 - 2012 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, iW Reach, eW Reach, eW Fuse, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice. DAS-000101-00 R00 05-12