ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
ABSTRACT
Couplers, also known as "isolators" because they electrically isolate as well as transmit
data, are widely used in industrial and factory networks, instruments, and telecommunications.
Everyone knows the problems with opto-couplers. They take up a lot of space, are slow, opto-
couplers age and their temperature range is quite limited. For years, optical couplers were
the only option. Over the years, most of the components used to build instrumentation circuits
have become ever smaller. Opto-coupler technology, however, hasn’t kept up. Existing coupler
technologies look like dinosaurs on modern circuit boards. Magnetic couplers are analogous to
opto-couplers in a number of ways. Design engineers, especially in instrumentation technology,
will welcome a galvanically isolated data coupler with integrated signal conversion in a single
IC. My report will give a detailed study about ‘ISOLOOP MAGNETIC COUPLERS’.
Page | 1
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
INDEX
SL NO CHAPTERS PAGE NO
CHAPTER 1
INTRODUCTION 04-05
CHAPTER 2INDUSTRIAL NETWORKS NEED ISOLATION 06
2.1 Ground Loops
CHAPTER 3GALVANIC COUPLERPHYSICS OF THE 07
GIANT MAGNETO RESISTANCE (GMR)
CHAPTER 4 GIANT MAGNETO RESISTIVE 08-12
4.1 GMR MATERIALS
CHAPTER 5 CONSTRUCTION OF ISOLOOP MAGNETICCOUPLER 13-16
5.1 Sensor Arrays
CHAPTER 6WORKING OF A ISOLOOP MAGNETIC COUPLER 17
CHAPTER 7 18-19
ADVANTAGES OF MAGNETIC COUPLING
7.1 Bandwidth
7.2 Small Footprint
7.3 Noise Immunity
7.4 Temperature Stability
CHAPTER 8 20-21DIGITAL ISOLATORS
Page | 2
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
8.1 Dynamic Power Consumption
8.2 Data Transmission Rates
CHAPTER 9 22COMPARISON BETWEEN OPTOCOUPLER AND ISOLOOP MAGNETIC COUPLER
CHAPTER 10 23CURRENT APPLICATIONS
10.1 Digital Isolation Applications
CHAPTER 11 24THE FUTURE SCOPE
CHAPTER 12 25CONCLUSION
CHAPTER 13 26REFERENCES
Page | 3
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
CHAPTER 1
INTRODUCTION
In many industrial control systems getting valuable data to its destination is often a
headache. Factors such as ground loops, noise, temperature extremes, and speed
bottlenecks can adversely affect data transmission. Opto-isolators have been until
recently the obvious solution, but their bulk, slow speed, high power consumption, and
limited temperature range now presents serious shortcomings for the designer.
A new generation of solid-state couplers IsoLoop magnetic couplers, has been
introduced which overcomes many Opto-coupler limitations. IsoLoop devices can be
combined with conventional integrated circuits to create single-package isolated
transceivers. Isolated transceivers are available in single 16-pin SOIC packages. These
devices support data rates as high as 40Mbps.IsoLoop couplers add an integrated
Insulating layer and a microscopic coil on top of a small sensor element bridge. A
magnetic field proportional to the input current signal is generated beneath the coil
winding. The resulting magnetic field is sensed across the dielectric film. The dielectric
provides 4,500 Volts DC of galvanic isolation Magnetic couplers are based on the Giant
Magneto resistance (GMR) effect, discovered by French scientists in 1988. GMR
materials are made from exotic metal alloys deposited in extremely thin layers and
formed into tiny resistors. The GMR resistors are sensitive to magnetic fields in the plane
of the substrate.
This enables a more compact integration scheme than would be possible with a
Hall sensor. The sensed magnetic field is amplified and conditioned with integrated
electronic circuits to produce an isolated replica of the input signal. Ground potential
Page | 4
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
variations, however, are common to both sides of the input coil, so they do not generate a
current. Thus no magnetic field results and these variations are not sensed by the GMR
structures. In this way, the signal is transparently passed from the input to the output
circuits while ground potential variations are rejected to achieve a very large common-
mode rejection ratio (CMRR) and true galvanic isolation.
Page | 5
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
CHAPTER 2
INDUSTRIAL NETWORKS NEED ISOLATION
2.1 Ground Loops
When equipment using different power supplies is tied together (with a common ground
connection) there is a potential for ground loop currents to exist. This is an induced current in the
common ground line as a result of a difference in ground potentials at each piece of equipment.
Normally all grounds are not in the same potential. Widespread electrical and communications
networks often have nodes with different ground domains. The potential difference between
these grounds can be AC or DC, and can contain various noise components. Grounds connected
by cable shielding or logic line ground can create a ground loop unwanted current
flow in the cable. Ground-loop currents can degrade datasignals, produce excessive EMI,
damage components, and, if the current is large enough, present a shock hazard. Galvanic
isolation between circuits or nodes in different ground domains eliminates these problems,
seamlessly passing signal information while isolating ground potential differences and common-
mode transients. Adding isolation components to a circuit or network is considered good design
practice and is often mandated by industry standards. Isolation is frequently used in
modems, LAN and industrial network interfaces (e.g., network hubs, routers, and switches),
telephones, printers, fax machines, and switched-mode power supplies.
Page | 6
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
CHAPTER 3
GALVANIC COUPLERS
0Opto-couplers transmit signals by means of light through a bulk dielectric that provides
galvanic isolation (see Figure 3.1). Magnetic couplers transmit signals via a magnetic field,
rather than a photon transmission, across a thin film dielectric that provides the galvanic isolation
(see figure 3.2).
Figure 3.1: Optical Isolator
Figure 3.2: Isoloop Isolator
As is true of opto-couplers, magnetic couplers are unidirectional and operate down to
DC. But in contrast to opto-couplers, magnetic couplers offer the high-frequency performance of
an isolation transformer, covering nearly the entire combined bandwidth of the two conventional
isolation technologies.
Page | 7
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
CHAPTER 4
PHYSICS OF THE GIANT MAGNETO RESISTANCE (GMR)
4.1 Giant Magneto resistive
Large magnetic field dependent changes in resistance are possible in thin film Ferro
magnet /nonmagnetic metallic multilayers. The phenomenon was first observed in France in 1988,
when changes in resistance with magnetic field of up to 70% were seen. Compared to the small
percent change in resistance observed in an isotropic magneto resistance, this phenomenon
was truly ‘giant’ magneto resistance. The spin of electrons in a magnet is aligned to
produce a magnetic moment. Magnetic layers with opposing spins (magnetic
moments) impede the progress of the electrons (higher scattering) through a sandwiched
conductive layer. This arrangement causes the conductor to have a higher resistance to current
flow. An external magnetic field can realign all of the layers into a single magnetic moment.
When this happens, electron flow will be less effected (lower scattering) by the uniform spins of
the adjacent ferromagnetic layers. This causes the conduction layer to have a lower
resistance to current flow. Note that these phenomenon takes places only when the
conduction layer is thin enough (less than5 nm) for the ferromagnetic layer’s electron spins to
affect the conductive layer’s electron’s path.
Page | 8
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
Figure: 4.1.1
Figure: 4.1.2
Figure 4.1.A: Nonmagnetic Conductive Layers
The resistance of two thin ferromagnetic layers separated by a thin nonmagnetic
conducting layer can be altered by changing the moments of the ferromagnetic
layers from parallel to antiparallel, or parallel but in the opposite direction.
Layers with parallel magnetic moments will have less scattering at the
interfaces, longer mean free paths, and lower resistance. Layers with antiparallel magnetic
moments will have more scattering at the interfaces, shorter mean free paths, and higher
resistance (see Figure 4.1.1 & 4.1.2).
Page | 9
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
Figure 4.1.B: Magneto Resistive Sensor
For spin-dependent scattering to be a significant part of the total resistance, the layers
must be thinner than the mean free path of electrons in the bulk material. For many Ferromagnets
the mean free path is tens of nanometers, so the layers themselves must each be typically <10 nm
(100 Å). It is therefore not surprising that GMR was only recently observed with
the development of thin film deposition systems.
The spins of electrons in a magnet are aligned to produce a magnetic moment. Magnetic layers
with opposing spins (magnetic moments) impede the progress of the electrons
(higher scattering) through a sandwiched conductive layer. This arrangement causes the
conductor to have a higher resistance to current flow.
Page | 10
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
4.2 GMR MATERIALS
There are presently several GMR multilayer materials used in sensors and sensor arrays. The
following chart shows a typical characteristic for a GMR material:
Figure 4.2: Characteristics of GMR Materials
Notice that the output characteristic is Omni polar, meaning that the material provides the
same change in resistance for a directionally positive magnetic field as it does for a directionally
negative field. This characteristic has advantages in certain applications.
For example, when used on a magnetic encoder wheel, a GMR sensor using this material
will provide a complete sine wave output for each pole on the encoder thus doubling the resolution of
the output signal.
Page | 11
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
The material shown in the plot is used in most of GMR sensor products. It provides
a 98% linear output from 10% to 70% of full scale, a large GMR effect (13% to 16%), a stable
temperature coefficient (0.15%/°C) and temperature tolerance (+150°C), and a large magnetic
field range (0to 300 Gauss ).
For spin-dependent scattering to be a significant part of the total resistance, the layers
must be thinner than the mean free path of electrons in the bulk material. And many
ferromagnets the mean free path is tens of nanometers, so the layers themselves must each be
typically <10 nm (100 Å). It is therefore not surprising that GMR was only recently observed
with the development of thin film deposition systems.
CHAPTER 5
CONSTRUCTION OF ISOLOOP MAGNETICCOUPLER
Page | 12
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
Figure 5.1: Isolator Data Travel
Figure 5.1 In a GMR, isolator data travels via a magnetic field through a dielectric
isolation to affect that resistance elements arranged in a bridge configuration.
Figure 5.2: Magnetic Coupler
To put this phenomenon to work, a Wheatstone bridge configuration of four GMR
sensors (see Figure 5.1 & 5.2). The manufacturing process allows thick film magnetic material to
be deposited over the sensor elements to provide areas of magnetic shielding or flux
concentration. Various op-amp or in-amp configuration scan be used to supply signal
conditioning from the bridge’s outputs. This forms the basis of an isolation receiver.
The isolation transmitter is simply coil circuitry deposited on a layer between the GMR
sensors layers and the thick film magnetic shielding layer (see Figure 5.1). Current through this
Page | 13
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
coil layer produce the magnetic field, which overcomes the antiferromagnetic layers there by
reducing the sensor’s resistance.
5.1 Sensor Arrays
GMR elements can be patterned to form simple resistors, half bridges,
Wheatstone bridges, and even X-Y sensors. Single resistor elements are t he sma l l e s t
dev i ce s and r equ i r e t he f ewes t componen t s , bu t t hey have poo r temperature
compensation and usually require the formation of some type of bridge by using
external components. Alternatively they can be connected in series with one differential
amplifier per sensor resistor. Half bridges take up more area on a chip but offer temperature
compensation, as both resistors are at the same t empe ra tu r e . Ha l f b r i dges c an be
u sed a s f i e l d g r ad i en t s enso r s i f one o f t he resistors is some distance from the
other. They can function as field sensors if one of the resistors is shielded from the applied field.
Figure 4 shows a portion of an array of 16 GMR half bridge elements with 5 µm spacing. The
elements are 1.5µm wide by 6 µm h igh w i th a s im i l a r s i z e e l emen t above t he
cen t e r t ap . The bottoms of the stripes are connected to a common ground connection and the
tops of the half bridges are connected to a current supply. The center taps are connected to 16
separate pads on the die. A bias strap passes over the lower elements to provide
a magnetic field to bias the elements.
Page | 14
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
5.1.1 Sensor Arrays
5.2 Signal Processing
Adding signal processing electronics to the basic sensor element increases the
functionality of sensors. The large output signal of the GMR sensor element Introduction
means less circuitry, smaller signal errors, less drift, and better temperature
stability compared to sensors where more amplification isrequired to create a usable output.
For the GMR products, we add a simple comparator and output transistor circuit to create
the world’s most precise digital magnetic sensor. For these products, no amplification of the
sensor’s output signal is necessary. A block diagram of this circuitry is shown in the figure 5.2.1.
Page | 15
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
Figure 5.2.1: Signal Processing Circuit
The GMR Switch holds its precise magnetic operate point over extreme
variations in temperature and power supply voltage. This is a low cost method.
CHAPTER 6
Page | 16
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
WORKING OF A ISOLOOP MAGNETIC COUPLER
In the Isoloop magnetic couplers, a signal at the input induces a current in a planar coil
(see figure no: 5).The current produces a magnetic field, which is proportional to the current
in the planar coil. The resulting magnetic field produces a resistance change in the GMR
material, which is separated from the planar coil by a high voltage insulating material. Since
the GMR is sensitive parallel to the plane of the substrate, this allows a considerably more comp
actconstruction than would be possible with Hall sensors. The resistance change in GMR
ma te r i a l , wh i ch was caused by t he magne t i c f i e l d , i s amp l i f i ed by an
electronic circuit and impressed upon the output as a reproduction of the input
signal. Since changes in the ground potential at the input, output or both doesn’t produce a
current in the planar coil, no magnetic field is created. The GMR material doesn’t change. In this
way safe galvanic signal isolation is achieved and at the same time a corresponding common mode
voltage tolerance.
CHAPTER 7
Page | 17
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
ADVANTAGES OF MAGNETIC COUPLING
The advantages of magnetic coupling include high bandwidth, small footprint, excellent
noise immunity, and temperature stability.
7.1 Bandwidth
I soLoop coup l e r s a r e 5–10 t imes f a s t e r t han t he f a s t e s t opto-couplers,
and have correspondingly faster rise, fall, and propagation times (see Figure 9).
Shorter rise and fall times also reduce power consumption in the device and system by
minimizing time in active regions.
Figure 7.1: Magnetic Couplers Traces
Page | 18
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
7.2 Small Footprint
IsoLoop couplers can be fabricated in <1 mm2 of die area per channel (see Figure 10).
Less board real estate means both more room for other functions and lower prices. Furthermore,
because of their small die size, IsoLoop couplers cost no more than high-performance opto-
couplers.
Figure 7.2: Four-Channel Magnetic Coupler Die
7.3 Noise Immunity
Magnetic couplers provide transient immunity up to 25 kV/µs,
compa red t o 10 kV/µs fo r op tocoup l e r s . T rans i en t immun i ty i s e spec i a l l y i
mportant in harsh industrial and process control environments.
7.4 Temperature Stability
Because the transmission and sensing elements are not subject to semiconductor
temperature variations, magnetic couplers operate to 100°C and above; for most opto-
couplers the upper limit is 75°C. Magnetic couplers are also immune to opto-couplers’ inherent
performance decay with age.
CHAPTER 8
Page | 19
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
DIGITAL ISOLATORS
These devices offer true isolated logic integration in a level not previously
available. All transmit and receive channels operate at 110 Mbd over the full temperature and
supply voltage range. The symmetric magnetic coupling barrier provides a typical propagation
delay of only 10 ns and a pulse width distortion of 2 ns achieving the best specifications of any
isolator device. Typical transient immunity of 30 kV/µs is unsurpassed.
8.1 Dynamic Power Consumption
Isoloop devices achieve their low power consumption from the manner by
which they transmit data across the isolation barrier. By detecting the edge transitions of the
input logic signal and converting these to narrow current pulses, a magnetic field is
created around the GMR Wheatstone Bridge. Depending on the direction of the magnetic
field, the bridge causes the output comparator to switch following the input logic
signal. Power consumption is independent of mark-to-space ratio and solely dependent on
frequency. This has obv ious advan t ages ove r op to - coup l e r s whose power
consumpt ion i s heav i l y dependent on its on-state and frequency. The maximum power
supply current per channel for IsoLoop is:
I (input) =40(f /fmax) (4/5) mA
Where f =operating frequency
fmax= 50 MHz
8.2 Data Transmission Rates
Page | 20
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
The reliability of a transmission system is directly related to the accuracy and
quality of the transmitted digital information. For a digital system, those parameters, which
determine the limits of the data transmission, are pulse width distortion and propagation,
delay skew.
Propagation delay is the time taken for the signal to travel through t he dev i ce .
Th i s i s u sua l l y d i f f e r en t when s end ing a l ow- to -h igh t han when s end ing a
h igh - to - l ow s igna l . Th i s d i f f e r ence , o r e r ro r , i s c a l l ed pu l s e w id th distortion
(PWD) and is usually in ns. It may also be expressed as a percentage:
P W D % = ( Maximum Pulse Width Distortion (ns)/Signal Pulse Width (ns)) x 100%
Propagation delay skew is the difference in time taken for two or more channels to
propagate their signals. This becomes significant when clocking is involved since it is
undesirable for the clock pulse to arrive before the data has settled. A short propagation delay
skew is therefore critical, especially in high data rate parallel systems, to establish and
maintain accuracy and repeatability. The IsoLoop range of isolators all has a
maximum propagation delay skew of 6 ns, which is five times better than any opto-
coupler. The maximum channel to channel skew in t he I soLoop coup l e r i s on ly 3 n s ,
t en t imes be t t e r t han any o the r opto-couplers.
CHAPTER 9
Page | 21
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
COMPARISON BETWEEN OPTOCOUPLER ANDISOLOOP MAGNETIC COUPLER
Unlike typical microsecond Ton/Toff times of opto-isolators, The IsoLoop-isolators also
have identical TON/TOFF times, which produce no pulse-w i d t h d i s t o r t i o n a s
i s t h e c a s e w i t h m a n y o p t o - i s o l a t o r s h a v i n g d i f f e r i n g Ton /Tof f
t imes . P ropaga t i on de l ays a r e l e s s t han 10 n s w i th i n t e r - channe l skewing of
less than 2 ns. Isoloop-isolators have up to four channels per package in a variety of device
direction configurations. These standard devices are great f o r bus i so l a t i on ,
s e r i a l ADCs and DACs , and commun ica t i on i so l a t i on . The work ing r ange
o f op to - coup l e r s i s on ly be tween ze ro and t en megahe r t z . The I soLoop
couplers have data transmission speeds up to100 mega baud. IsoLoop devices will
operate over a wide temperature range of -40 to +100C, compared with the restricted
range of 0 to +70C for opto-isolators. The power consumption of IsoLoop devices is solely
dependent on frequency. This makes for lower power consumption than opto-isolators, whose
power consumption is heavily dependent on state and frequency. With data rates up to
100Mbaud, the IsoLoop technology offers rates of up to ten times that of opto-isolators.
CHAPTER 10
Page | 22
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
CURRENT APPLICATIONS
Magnetic isolators are quickly finding their way into process control and industrial
applications. Isolation of A/D interfaces is one popular use.
Inadd i t i on , magne t i c i so l a to r s ’ combina t i on o f speed and packag ing dens i t
y provides a good method of efficient data channel management when multiple A/Ds need to
be interfaced on the same circuit card. A four-channel part with t h r ee channe l s
go ing one way and one go ing t he o the r i s ava i l ab l e fo r A /D in t e r f ace
app l i c a t i ons . Magne t i c coup l e r s a l so enab l e h ighe r speed f ac to ry networks
such as Profibus and other protocols. These devices are great for bus isolation, serial
ADCs and DACs, and communication isolation. The combination of the fast and high-
density IsoLoop couplers with high packing density allow s ufficient data channel
management where several A/D channels must be isolate don a board.
10.1 Digital Isolation Applications
ADCs DACs Multiplexed Data Transmission Data Interfaces Digital Noise Reduction Ground Loop Elimination
CHAPTER 11
Page | 23
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
THE FUTURE SCOPE
Magnetic field detection has vastly expanded as industry has used
ava r i e t y o f magne t i c s enso r s t o de t ec t t he p r e sence , s t r eng th , o r d i r e c t i on
o f magnetic fields from the Earth, permanent magnets, magnetized soft magnets, and the
magnetic fields associated with current. These sensors are used as proximity sensors, speed and
distance measuring devices, navigation compasses, and current sensors. They can measure these
properties without actual contact to the medium being measured and have become the eyes of
many control systems.
CHAPTER 12
Page | 24
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
CONCLUSION
Magnetic couplers will in time be even faster and have more channels. More types of
integrated bus transceivers will be available. Several manufacturers a r e p l ann ing t o
i n t roduce magne t i c coup l e r s . The U .S . m i l i t a ry i s p rov id ing significant
funding for advanced magnetics coupler development because of the value of their
high speed and noise immunity in aircraft and other systems. It has reported prototype devices
with speeds of 300 Mbaud and switching times of <1ns. Also under development are higher-
density parts (full byte-wide couplers) and more functionality (latching bus transceivers).
Finally, the inherent linearity of are sensitive coil and resistive sensing elements make magnetic
couplers well suited for linear data protocols such as low-voltage differential signaling.
CHAPTER 13
Page | 25
ISOLOOP MAGNETIC COUPLERS REPLACE OPTO-COUPLERS
REFERENCES
1. J .Daugh ton and Y . Chen . "GMR Mate r i a l s f o r Low F i e ld App l i c a t i ons , " IEEE Trans Magn, Vol. 29:2705-2710, 2003.pp.18-21
2. Michae l J . Ca ruso , Tamara Bra t l and , C . H . Smi th , and Robe r t Schne ide r , “A New Perspective on Magnetic Field Sensing,” Sensors Magazine, vol.15, no. 12, (December 2002), pp. 34-46
3. Ca r l H . Smi th and Robe r t W. Schne ide r , “Low-F ie ld Magne t i c Sens ing with GMR Sensors, Part 1: The Theory of Solid-State Sensing,” Sensors Magazine, vol. 16, no. 9, (September 2002), pp. 76-83.
4. Ca r l H . Smi th and Robe r t W. Schne ide r , “Low-F ie ld Magne t i c Sens ing w i t h G M R S e n s o r s , P a r t 2 : G M R S e n s o r s a n d t h e i r A pp l i c a t i o n s , ” Sensors Magazine, vol. 16, no. 10, (October 2002), pp. 84- 91.
5. http://www.circuitcellar.com/library/print/0502/JEFF/4.asp
6 . h t t p : / / w w w . s e n s o r s m a g . c o m /
7. http://www.nve.com/isoloop/news/hispdnr.php
8 . h t t p : / /www.e l ec t ron i c s t a lk . com/news / rho / rho000 .h tml
Page | 26