Innovative Solutions to Improve Comfort & EfficiencyNEX and PLAY
Discomfort is Expansive
Office Building• Average HVAC technician service call:
$400
• Absenteeism
• Decreased employee performance
• Cost of over heating and over cooling
• Extreme cases of losing employees: cost of re-hiring, re-training, loss of productivity
What about a restaurant?
• Seating capacity: 300
• Open 360 nights / year
• Average 1 dinner / seat / night
• Total 108,000 customers / year
• Some feel air distribution-related discomfort
• 2% of customers would've stayed a bit longer if slightly more comfortable, just enough to buy one last drink or dessert
• Average gross profit per drink or dessert: $3
• Seating capacity: 300
• Open 360 nights / year
• Average 1 dinner / seat / night
• Total 108,000 customers / year
• Some feel air distribution-related discomfort
• 2% of customers would've stayed a bit longer if slightly more comfortable, just enough to buy one last drink or dessert
• Average gross profit per drink or dessert: $3
$6,840 profit / yearConsequence:
Common sources of air distribution related
discomfort
A well designed HVAC System
Performs really well in theoretical or average
conditions
Cold air supplied at low velocity
... Will drop from standard diffusers
While at higher velocity...
Air jets collide and are deflected
How can we improve performance in VAV
applications?
Using a diffuser providing higher tolerance to velocity and temperature variations.
NEX Concave Elements
• Won a new products contest as the Best Heating Component
• Also ideal for cooling and VAV applications
• Innovative architectural look
NEX Concave Elements
• Swirl pattern
• Air diffused in multiple jets of various velocities
• High induction ratio, mixes more air, faster and more evenly
• Higher tolerance to temperature and velocity variations
Another very common issue causing discomfort
• Flex duct with kink or angle
• Up to 80% of airflow could be diffused in one direction
• Same issue with rigid duct and 90 degree elbows
In theory, ASHRAE recommends
• Rarely happens in real world
• Most of the time, not enough space in the ceiling
• Sometimes installer just lazy, poorly trained or trying to save on time and material
NEX + PERFAIR
• 2 layers of air equalizing
• First layer: damper + equalizer integrated in plenum's neck
• Second layer: the Concave Elements. No direct exit, air is forced to swirl inside the plenum
Energy Efficiency
• Stratification & uneven mixing of supplied air with room air causing inaccurate or varying measurements of thermostat and humidistat
• Can result in over-heating / over-cooling
• Equipment on/off and modulation = more energy used to achieve same result as steady conditioning
Return on InvestmentAn HVAC system is a chain of components
A chain is only as strong as its weakest link
Cost adds up... Not Performance!
What about unpredictable factors?
• At design time, impossible to know and plan for everything
• Added furniture and decorative objects might obstruct and deflect air jets
• Cubicle layout modified
• Each individual's tolerance to hot and cold
Solutions available so far
• Blocking air in one or more directions
• Air volume control damper
• Adjustable diffusers, from horizontal to vertical airflow
• VAV diffusers, expansive to purchase and to install
The new solution
PLAY Adjustable Sectors
• Only diffuser allowing for full horizontal adjustment
• Easy to adjust, from the face and without tools
• 1, 2, 3, 4 way and swirl with easy sectors positioning
• Can also be adjusted by as many degrees as required to avoid people and objects
• Innovative architectural look
Example 1 - Cubicle Layout
7/8 comfort ratio1 person complains about the cold
Solution 1 : adjust damper to reduce the volume of cold air
supplied
5/8 comfort ratio
Solution 2 : block one way
5/8 comfort ratio
Solution 3 : block one way + adjust damper for less volume
7/8 comfort ratio
PLAY Solution: adjust horizontal angle just enough to fix issue
8/8 comfort ratio
From Above
From Above
Solved the comfort issue...
In the most energy efficient way
PLAY Adjustable Sectors
• Gives flexibility to quickly solve air distribution issues
• Fewer and cheaper service calls
• Increased general level of comfort
• Can help optimizing energy
Just PLAY with it!
PLAY-R
New design possibilities
Horizontal spread in narrow spaces
Hallways
Blends in perfectly
while supplying air
efficiently
• High tolerance to velocity and temperature variations
• Not affected by angle of air entering diffuser
• High Induction Rate
• Great for limited space in the ceiling
• Choice of 5 Concave Element colors
NEX - Reliability
PLAY - Flexibility• High tolerance to velocity and temperature variations
• Not affected by angle of air entering diffuser
• High Induction Rate
• Great for limited space in the ceiling
• Choice of 5 Concave Element colors
• Optimize Comfort and Energy
• Only diffuser allowing for full horizontal adjustment
• Easy to install, easy to use
• New design possibilities
• Save money on first service call
NEX - Reliability
PERFAIR plenums with Top or Side connexions
PLAY - Flexibility• High tolerance to velocity and temperature variations
• Not affected by angle of air entering diffuser
• High Induction Rate
• Great for limited space in the ceiling
• Choice of 5 Concave Element colors
• Optimize Comfort and Energy
• Only diffuser allowing for full horizontal adjustment
• Easy to install, easy to use
• New design possibilities
• Save money on first service call
Suitable for all types of ceilings (Lay-in, Drywall, Open)
NEX - Reliability
Both can easily replace diffusers in existing buildings
You now have the option!