• One of the oldest (1962) and largest Acoustical and AVL Consulting firms.
• National Council of Acoustical Consultants
• National Best and Brightest Companies to Work For
• National Best and Brightest Sustainable Companies
• National Presence
Kenric Van Wyk PresidentPE, INCE Bd. Cert,
LEED AP BD+C EDAC
Over 25 years experience President NCAC
Tim Hamilton Director of AVL
Senior AVL Consultant CTS-D
19 years experience
Certified Crestron Programmer
16 years experience
Tim Heneveld Senior AVL Consultant
American Institute of Architects (AIA) Associate
12 years experience
Mindy Tangney Architectural Coordinator
Certified Technology Specialists infoComm CTS-D
InfoComm provides industry standards as the foundation for quality audiovisual systems.
Harley-Davidson Experience
• PDC 30 Conference rooms
• Harley-Davidson Museum
• Wedding Tent
• Garage
• Bunker
SystemRequirements• 4KUHDorbe6erdisplay• Flexibleguestconnec?onstodisplay• User-friendlycontrols• Integratedaudioandteleconferencing• Flexibleand/orscalablesystem• Flexibleintermsofconfigura?onofthespace
PixelsHow many?
PixelsComponent HD 720p
720 Lines
PixelsBluRay HD 1080p
1080 Lines
Pixels4K
Ultra HD (UHD) 2160 Lines
Projector/Mirrorheat, heat shimmer, consumables
#�8�%#$+0'6��������Z����
14'-3"
VJ-
1
EXISTING RACK
FB-1
S
PROJECTOR -USE EXISTINGPROJ. POWER
PROJECTIONSCREEN
S
S
S
S
S
M
M
M
M
M
M
M
M
M
M
M
M
M
2/AV-2102/AV-210
WP-2
DM-8
2@C5e
CABLING THROUGHTHE FLOOR RACEWAY
CABLES TRAVEL UP THROUGHPILLAR AND ABOVE CEILING TOEXIST. EQUIPMENT RACK
MIRROR
46" LCD MONITOR
VJ-
2
55" LCD MONITOR
NOTE: REUSE EXISTING CEILINGSPEAKERS IN PDC-22
2@C5E1@V52@L
NOTE: CABLES GOTHROUGH PILLAR TOEXISTING RACK
2@C5E
1@M
2@C5E
1@M
1@M
TO EXISTING RACK
1@M
TO EXISTING RACK
1@M
TO EXISTING RACK
1@M
TO EXISTING RACK
1@M
TOEXISTINGRACK
1@M
TO EXISTING RACK
1@S16
1@M
1@S16
1@M
1@S16
1@M
OC
EXIST.
1@S16
S
1@S16
S
1@M
1@S16
SS
1@S16
1@S16
S
S
1@S16
1@S16
1@S16
1@S16
1@M
1@P4
iPlate
LIT PRESENTATIONAREA
2@L
TO EXISTING RACK
PROJECTIONSCREEN
HANGING MICS
9'-6"
46" LCD MONITOR@ 24.2"Hx40.3"Wx5.2"D
EXIST. DOOR8'
812"
9'-6"EXIST. DOOR
8'-2"7'-7"7'-7"
EXISTING SCREEN SIZE 8'
16'
15'-2"4K (4096 X 2160)
CURRENT EDGE BLEND
SCREEN A
STUD WALL FRAMING 16" ON CENTERVERIFY EXACT CONDITIONS IN FIELD.
STUD WALL CONSTRUCTIONVERIFY EXACT CONDITIONS
IN FIELD.
2 X 6 BLOCKING
8'-2"
46" LCD DISPLAY POWER OUTLETMETAL CLAD CABLEWIRES FISHED IN CAVITY
46" LCD MONITOR
7'-5"7'-5"
7'-7"
CEILINGCEILING
EXISTING DOOR
16'14'-23
4"
4'-412"
PROJECTIONSCREEN
HANGINGMICS
8'
812"
9'-6"
1'-6"
OWNER TO REMOVEEXISTING RAISEDFLOOR INPROJECTION ROOM
EXIST. FLOORBELOW
20°
AV NETWORK DROPROOM LOCATION NUMBER
STATIC ORDYNAMIC IP ADDRESS
BUNKER DESK RACK AER-LEFT 0 STATIC
BUNKER DESK RACK AER-RIGHT 4 STATIC
BUNKER DESKTOP 1 STATIC
BUNKER CEILING 1 STATIC
PDC-23 DESK 2 STATIC
PDC-23 PROJECTION 0 STATIC
PDC-23 EXIST. RACK IN STORAGE 1 STATIC
PDC-23 CEILING 1 STATIC
STUD WALL FRAMING 16" ON CENTERVERIFY EXACT CONDITIONS IN FIELD.
STUD WALL CONSTRUCTIONVERIFY EXACT CONDITIONSIN FIELD.
2 X 6 BLOCKING
8'-2"
55" LCD DISPLAY POWER OUTLETMETAL CLAD CABLEWIRES FISHED IN CAVITY 55" LCD MONITOR
6'-10"
7'-4"
CEILINGCEILING
6'-10"
AV JUNCTION BOX SCHEDULEBOX # LOCATION SIZE
MOUNTINGHEIGHT
MOUNTINGTYPE
BOX & COVERPROVIDED BY
CONN. PLATEPROVIDED BY NOTES
FB-1 BUNKER NOTE FLOOR FLUSH EC AV FSR FL-500P
FB-2 BUNKER NOTE FLOOR FLUSH EC AV FSR FL-500P
FB-3 BUNKER NOTE FLOOR FLUSH EC AV EXISTING
PROJ BUNKER 4" SQ. CEILING SURFACE EC AV EXISTING
VJ-1 PDC22-23 1 GANG 8'-2" AFF FLUSH EC AV
VJ-2 PDC22-23 1 GANG 8'-2" AFF FLUSH EC AV
WP-1 BUNKER 2 GANG 0" AFF FLUSH EC AV
WP-2 PDC 23 2 GANG 18" AFF FLUSH EC AV
NOTES:
1. ALL MOUNTING HEIGHTS ARE TO THE BOTTOM OF THE BOX.
PRELIM
INARY
NOT FOR CONSTRUCTIO
N
DATES OF ISSUE
DESCRIPTION
Copyright 2011 Acoustics By Design, Inc. Allinformation on this drawing is the exclusive
property of Acoustics By Design, Inc. and isfurnished for use on the above project only. Nopart of this drawing may be duplicated withoutwritten consent from Acoustics By Design, Inc.
DATE
5/6/11
NO.
DESIGN DEVELOPMENT
MIL
WAUKE
E, W
IAVL
REN
OVATI
ONS
HARLE
Y D
AVID
SO
N
PDC 22-23 AV PLAN
DATE
PLO
TTED
: W
edne
sday
, Ju
ly 2
0,
20
11
12
:08
:18
PM
1/8" = 1'-0"---- ----
TGH, SS
MLT
TGH, SS
5/17/11 DESIGN DEVELOPMENT
7/21/11 FOR REVIEW
SCALE: 1/4" - 1'-0"PDC 22-32 ELEVATION2
SCALE: 1/4" - 1'-0"PDC 22-32 AVL PLAN1
SCALE: 1/4" - 1'-0"SCREEN SIZE COMPARISON11SCALE: 1/4" - 1'-0"
46" WALL MOUTNED MONITOR DETAIL5
SCALE: 1/4" - 1'-0"55" WALL MOUTNED MONITOR DETAIL6
04/28/2011
SCALE: 1/4" - 1'-0"PROJECTOR MOUNT ELEVATION8
SCALE: 1/4" - 1'-0"PROJECTOR MOUNT PLAN7
NO SCALEAV JUNCTION BOX SCHEDULE4
NO SCALEAV NETWORK DROP3
Video WallBezels, consistency, replacement
Microtilesbezel
Prysmbezels can be visible
Prysmdepending on image and angle - bezels are less visible
LED Video WallNo Bezel, higher cost
8k…
13-feet
Apple Retina Display 2dr TAN(.5deg) = 57 ppd
d = distance to display r= pixels per unit
1.2mm Display Best Available
Integrated Design
• Independent
• Qualified
• Experienced
• We know Harley-Davidson