4
1 VD.BO.I1.02 © Danfoss 06/2013 DEN-SMT/SI Description FV strainer is used in heating and hot- waterservice systems to protect the fittings. The strainer filter traps foreign matters in the pipe water like welding beads, swarf, sand, etc.FV must be fitted in the system flow to protect the fittings from external foreign matters. FV must also be fitted ahead of sensitive components like meters, pumps,control valves to protect against internal foreign matters. Features: Replaceable filter Version with draining ball valve (FVR-D) Main data: DN 10-50 k vs 3-36 m 3 /h PN 25 Temperature: −10 … 130 °C Medium: Circulation water / glycolic water up to 50 % Min. storage and transport temperature: −40 °C Threaded connection Ordering Picture DN (mm) k vs (m 3 /h) FVR Code No. FVR-D Code No. 10 3 065B8234 - 15 4,5 065B8235 065B8241 20 7,9 065B8236 065B8242 25 11,2 065B8237 065B8243 32 17 065B8238 065B8244 40 24,5 065B8239 065B8245 50 36 065B8240 065B8246 Spare parts - Screen Picture DN (mm) FVR, FVR-D Code no. 10 065B8247 15 20 065B8248 25 065B8249 32 065B8250 40 065B8251 50 065B8252 Accessories - Ball valve Picture DN (mm) FVR-D Code no. 10 065B8254 15 20 25 32 40 50 FVR FVR-D Data sheet FVR, FVR-D Strainers

FVR, FVR-D Strainers

Embed Size (px)

Citation preview

Page 1: FVR, FVR-D Strainers

1VD.BO.I1.02 © Danfoss 06/2013DEN-SMT/SI

Description

FV strainer is used in heating and hot-waterservice systems to protect the fittings. The strainer filter traps foreign matters in the pipe water like welding beads, swarf, sand, etc.FV must be fitted in the system flow to protect the fittings from external foreign matters. FV must also be fitted ahead of sensitive components like meters, pumps,control valves to protect against internal foreign matters.

Features:• Replaceablefilter• Versionwithdrainingballvalve(FVR-D)

Main data:• DN10-50• kvs 3-36 m3/h• PN25• Temperature:−10…130°C• Medium:Circulationwater/glycolicwaterup

to50%• Min.storageandtransporttemperature:−40°C• Threadedconnection

OrderingPicture DN

(mm)kvs

(m3/h)FVR

Code No.FVR-D

Code No.

10 3 065B8234 -

15 4,5 065B8235 065B8241

20 7,9 065B8236 065B8242

25 11,2 065B8237 065B8243

32 17 065B8238 065B8244

40 24,5 065B8239 065B8245

50 36 065B8240 065B8246

Spare parts - Screen

Picture DN(mm)

FVR, FVR-DCode no.

10065B8247

15

20 065B8248

25 065B8249

32 065B8250

40 065B8251

50 065B8252

Accessories - Ball valve

Picture DN(mm)

FVR-DCode no.

10

065B8254

15

20

25

32

40

50

FVR FVR-D

Data sheet

FVR, FVR-D Strainers

Page 2: FVR, FVR-D Strainers

2 VD.BO.I1.02 © Danfoss 06/2013 DEN-SMT/SI

Ordering Nominal diameter DN 10 15 20 25 32 40 50

Value kvs m3/h 3 4,5 7,9 11,2 17 24,5 36

Nominalpressure PN 25

Medium Circulationwater,glycolicwaterupto50%

MediumpH Min.7,Max.10

Mediumtemperature °C 0…130

Meshsize µm 500

Numberofmeshes n/cm2 50

Connection InternalthreadRp

Materials

Body(strainer) Dezincificationfreebrass

Plug(strainer) Dezincificationfreebrass

Screen Stainless steel

O-ring EPDM

Body(ballvalve) Brass

Installation positions The medium flow direction must correspond to an arrow on the strainer body. Strainersaretobeinstalledinhorizontalposition with mesh bonet directed downwards. Verticalpositionisalsoallowed(beaware-whenmedium flows upwards strainer retains all foreignparticlesbutisnotabletocollectthem).

Sufficient space to pull out the mesh forreplacement and cleaning must be ensured.

Applications

Data sheet FVR, FVR-D Strainers

Page 3: FVR, FVR-D Strainers

3VD.BO.I1.02 © Danfoss 06/2013DEN-SMT/SI

Pressure temperature diagram

Design

1. Valve body 2. Screen 3. O-ring 4. Plug 5. Draining ball valve

③④

DN15

DN25DN20

DN32

DN40

DN50

DN10

Data sheet FVR, FVR-D Strainers

Sizing - Headlosschart

FVR-D

FVR

Page 4: FVR, FVR-D Strainers

4 VD.BO.I1.02 ProducedbyDanfossA/S©06/2013

Dimensions

Type DNConnection A B C Ch filter D E

Rp mm

FVR

10 ³/₈ 40 12,3 57 26 19

15 ½ 39 15 67 26 19

20 ¾ 49 16,3 81 32 26

25 1 57 19,1 97 39 31

32 1 ¼ 66 21,4 104 48 36

40 1 ½ 74 22 118 55 43

50 2 94 26,3 145 67 56

FVR-D

15 ½ 39 15 67 26 19 84 60

20 ¾ 49 16,3 81 32 26 93 66

25 1 57 19,1 97 39 31 105 72

32 1 ¼ 66 21,4 104 48 36 111 80

40 1 ½ 74 22 118 55 43 122 87

50 2 94 26,3 145 67 56 150 105

FVR FVR-D

B min.

C

Rp

Ch

A

B min.

C

Rp

Ch

AE

G ¼”

D

Data sheet FVR, FVR-D Strainers