Upload
vibropac
View
28
Download
9
Embed Size (px)
Citation preview
InfoInfoInfoInfoInforrrrrmationmationmationmationmationSheetSheetSheetSheetSheetFlexiprene™ LiquiPro™ 4-Function Valve
For 300 Series Cartridge Valve Type Liquid Ends
InfoInfoInfoInfoInforrrrrmationmationmationmationmation
Anti-SyphonA positive diaphragm-type anti-syphonfunction makes it possible to meterliquids “down hill”.
Back PressureSupplies approximately 20 psi (1.4 Bar)back pressure to prevent over-pumpingwhen little or no system pressure ispresent.
Priming - Pressure ReleaseThis function makes it easy to depressurizethe discharge line without looseningtubing or fittings. It also allows youto prime your LMI pump while it isconnected to a pressurized line.
Pressure Relief FunctionProvides protection against excessivesystem pressure
Materials of Construction
Part No. Tubing Size Diaphragm Body37368 1/4" O.D. Tubing Flexiprene™ PGC™
37369 3/8" O.D. Tubing Flexiprene™ PGC™
37370 1/2" O.D. Tubing Flexiprene™ PGC™
37371 1/4" NPT Pipe Flexiprene™ PGC™
1910.A 4/98
Part numbers are for 300 Series LiquiPro™ cartridge valve type Liquid Ends only.
© 1998 LMI Milton Roy - All Rights ReservedPrinted in USASpecifications subject to change without notice.
A. PRIMING
1. Connect return tubing to (relief) port.
2. Route tubing to solution tank. Be sure the end of tubing isabove the maximum solution level (Do not submergetubing in solution).
3. Turn Relief Knob 1/4 turn to open.
4. Set pump at 80% speed and 100% stroke. Start pump.When solution begins to flow through translucent returntubing, the pump is primed.
5. Stop pump. Turn Relief Knob 1/4 turn to close.
NOTE:
(a) Pump is normally self-priming if suction lift is no more than5 ft (1.5 m), valves in the pump are wet with water (pump isshipped from factory with water in pump head) and theabove steps (A1 through A4) are followed.
(b) If the pump does not self prime, remove 4-function valve andDischarge Cartridge Valve, and pour water or solutionslowly into discharge port until it is filled. Replace Car-tridge Valve, and follow steps A1 through A4 thereafter.
B. DEPRESSURIZING DISCHARGE LINE
1. It is possible to depressurize discharge line and pump headwithout removal of tubing or loosening of fittings.
Be sure injection check valve is properly installed and isoperating. If a gate valve or globe has been installed, down-stream of the injection check valve, it should be closed. Be certainreturn tubing is connected and run to solution supply tank.
Instruction Instruction Instruction Instruction Instruction SheetSheetSheetSheetSheetFlexiprene™ LiquiPro™ 4-Function Valve
For 300 Series Cartridge Valve Type Liquid Ends
2. Turn Relief Knob 1/4 turn to open.
3. Solution should exit the return tubing. The dischargeline is now depressurized.
4. If injection check valve is of higher elevation thanpump head, disconnecting tubing at injection checkvalve end will allow air to enter and cause solution todrain back to tank.
METHOD OF OPERATION
Flexiprene, LiquiPro and PGC are trademarks of Liquid Metronics, Inc.
Key PartNo. No. Description 37368 37369 37370 373711 34704 4FV Body, 1/4" PGC™ 1
34706 4FV Body, 3/8" PGC™ 134708 4FV Body, 1/2" PGC™ 135864 4FV Body, 1/4" NPT PGC™ 1
2 36260 P/R Cap Asm 1 1 1 13 37367 A/S Cap Asm 1 1 1 14 25628 Nut 4 4 4 45 25627 Screw 4 4 4 46 25631 Coupling Nut 1 1 1 17 25636-10 Tubing 1 1 1 18 10299 Coupling Nut 1 1
10411 Coupling Nut 19 28663 Ferrule 110 26136 Clamp Ring 1