Upload
sm-kumar
View
469
Download
0
Embed Size (px)
Citation preview
DESIGN VERIFICATION OF A RESIDENTIAL BUILDING
ByK.Azarudeen-13BCL0096S.Muthukumar-13BCL0304P.Mohankumar-13BCL0327
PROBLEM DEFINITION
• Design Verification of a residential building using a software - (Staad pro 2015) .
• Residential building of G+1 floor from a location(Pudukottai) is taken for verification
THE DESIGNED PLAN OF BUILDING
SNAPS OF THE BUILDING
VALUES ADOPTED
• SLAB: 0.15m (depth)• BEAM: 0.25m x 0.3m• COLUMN: 0.3m x 0.3m• LIVE LOAD: 3kN/m (maximum adopted)
DESCRIPTION
• The buildings live load and dead load is calculated from the type of material used and the dimensions
• Dimensions of slab, beams, column, footing of a residential building are verified for compliance to Indian Code
• M20 concrete and Fe415 steel have been used for this building• The plan and photos of the building are provided.
3D RENTERING OF THE RESIDENTIAL BUILDING
DEAD LOAD LIVE LOAD
LOAD COMBINATION OF DL & LL
EXCEL SHEET FOR RECTANGULAR BEAM CHECK
EXCEL SHEET FOR ONEWAY SLAB CHECK
EXCEL SHEET FOR TWOWAY SLAB CHECK
Learning basics of IS CODE Books
Designing a residential building
Make an Excel calculation to
design Beam,Coloumn,
Slab
Analysing the building in STAAD pro and
conclusion
Learning basics of
STAAD PRO
Steps involved
PARAMETERS 1st 2nd 3rd 4t
h1st 2nd 3rd 4th 1st
Learning basics of STAAD PRO
Learning basics of ISCODE BooksDesigning a residential building
Make an Excel calculation to
design Beam,Coloumn,
Slab
Verify the calculation values to STAAD PRO output values
2nd 3rd 4th 1st 2nd 3rd 4th
JULY AUGUST SEPTEMBER
OCTOBERACTIVITY CHART
ERRORS & MISTAKES
• Error caused in assigning the dimensions to the particulars
• Beams were not intersected properly which leads to error in calculation
• Not intersecting the slabs.• Assigning live load in wrong directions.• Worksheet assigning errors.• Assuming wrong standard values in calculations.
LEARNIGS
• Design a building using STAAD pro for • 1)Dead load and live load assigning• 2)Dimension assigning• 3) Basic kinds of possible errors• 4) Problems in automatic load design.• Learned to use excel sheet.• IS 875(part2) for residential building.• Basic design of Beams, Colums, Slabs in worksheet and
hand calculations.
REFERENCES
• IS: 875(part 1), IS: 875(part 2)• IS 456:2000, SP-16• https://youtu.be/Ae44Fp8JmKE• staad pro and excel tutorials from youtube
CONCLUSIONS
• The resistance to the live load and dead load is verified for beams,columns,and slabs of the building.
• The results were compared to the actual plan and the safety criteria is checked.