Upload
ra-m
View
414
Download
7
Embed Size (px)
DESCRIPTION
POWER PLANT ENGINEERING I HAVE TAKEN
Citation preview
BY
MAHA BARATHI ENGINEERING COLLEGE
RAMANATHAN.R/AP/EEE
UNIT-1
THERMAL POWER PLANT
THERMAL POWER PLANT
TURBINE
Cross section view of turbines
COOLING TOWERS
Working block diagram of
thermal power plant
UNIT-2
HYDRO ELECTRIC POWER
PLANTS
Suited for high head, low flow sites.
The largest units can be up to 200 MW.
Can operate with heads as small as 15 meters
and as high as 1,800 meters.
Pelton Wheels
• Combined action of pressure and moving
water.
• Runner placed directly in the water stream
flowing over the blades rather than striking each
individually.
•L ower head and higher flows than compared
with the impulse turbines.
Reaction Turbines
The inlet is a scroll-shaped tube that wraps around the turbine's wicket gate.Water is directed tangentially, through the wicket gate, and spirals on to a propeller shaped runner, causing it to spin. The outlet is a specially shaped draft tube that helps decelerate the water and recover kinetic energy
Kaplan Turbine
The inlet is spiral shaped.
Guide vanes direct the water tangentially to the
runner.
This radial flow acts on the runner vanes,
causing the runner to spin.
The guide vanes (or wicket gate) may be
adjustable to allow efficient turbine operation
for a range of water flow conditions.
Francis Turbines
Layout of hydro electric power plant
Hydro power plant
UNIT-3
NUCLEAR POWER PLANT
Layout of nuclear power
plant
•Steam outlet
•Fuel Rods
•Control Rods
Inside a Nuclear Reactor
• 235U fissions by absorbing a neutron and producing 2 to 3 neutrons, which initiate on average one more fission to make a controlled chain reaction•Normal water is used as a moderator to slow the neutrons since slow neutrons take longer to pass by a U nucleus and have more time to be absorbed•The protons in the hydrogen in the water have the same mass as the neutron and stop them by a billiard ball effect•The extra neutrons are taken up by protons to form deuterons•235U is enriched from its 0.7% in nature to about 3% to produce the reaction, and is contained in rods in the water•Boron control rods are inserted to absorb neutrons when it is time to shut down the reactor•The hot water is boiled or sent through a heat exchanger to produce steam. The steam then powers turbines.
Nuclear Reactor works
Nucleons more tightly bound in Fission Product Nuclei – Gives
200 Mv Energy per Fission
UNIT-4
GAS AND DIESEL POWER
PLANTS
DIESEL POWER PLANT
UNIT-5
NON CONVECTIONAL
POWER GENERATION
OTEC (OCEAN THERMAL
POWER PLANT)
How Does it Work
•Carnot Efficiency (T1-T2)/T1: in
transferring heat to do work, the
greater the spread in temperature
between the heat source and the heat
sink, the greater the efficiency of the
energy conversion.
•As long as the temperature between
the warm surface water and the cold
deep water differs by about 20°C
(36°F), an OTEC system can produce
a significant amount of power with a
maximum Carnot Efficiency of about
6.7%
•Low Environmental ImpactThe distinctive feature of OTEC energy systems is that the end products include not only energy in the form of electricity, but several other synergistic products.•Fresh WaterThe first by-product is fresh water. A small 1 MW OTEC is capable of producing some 4,500 cubic meters of fresh water per day, enough to supply a population of 20,000 with fresh water.•FoodA further by-product is nutrient rich cold water from the deep ocean. The cold "waste" water from the OTEC is utilised in two ways. Primarily the cold water is discharged into large contained ponds, near shore or on land, where the water can be used for multi-species mariculture (shellfish and shrimp) producing harvest yields which far surpass naturally occurring cold water upwelling zones, just like agriculture on land.
Advantages
WIND POWER PLANT
TIDAL POWER PLANT
AdvantagesThe energy is free – no fuel needed, no waste producedNot expensive to operate and maintainCan produce a great deal of energy
DisadvantagesDepends on the waves – sometimes you’ll get loads of energy, sometimes almost nothingNeeds a suitable site, where waves are consistently strongSome designs are noisy. But then again, so are waves, so any noise is unlikely to be a problemMust be able to withstand
•Noise pollution
•Displace productive fishing sites
•Change the pattern of beach sand nourishment
•Alter food chains and disrupt migration patterns
•Offshore devices will displace bottom-dwelling organisms where they
connect into the
Environmental Impact-
•Earth emits some 44TW of energy. Not
homogeneously
•As a rough rule, 1 km3 of hot rock cooled
by 1000C will yield 30 MW of electricity
over thirty years.
•The heat flux from the center of the Earth
can fulfill human energy demands (Joules
are there, by techniques….)
Geothermal Energy
Hot Water Reservoirs: hot underground water. Large number, but best suited
for space heating
Natural Steam Reservoirs: Steam comes to the surface. This type of
resource is rare in the US.
Geopressured Reservoirs: Brine saturated with natural gas (overpressurized).
This type of resource can be used for both heat and for natural gas.
Geothermal Energy Sources
DRY STEAM: steam moves through turbine and condenses to form water which acts as heat source
FLASH STEAM: extremely hot water is turned or “flashed” into steam from a decrease in pressure, steam drives turbine to produce heat energy
BINARY CYCLE: hot water goes through heat exchanger, heats up another fluid such as isobutane in a closed loop system, second fluid now boils at lower temperature than hot water and turns to steam much faster, steam drives turbine
=> most commonly used (steam = rare)
MAGNETO HYDRO DYNAMICS (MHD) SYSTEM
Contents
1. Introduction2. Need of MHDs3. Principle Of MHD Power Generation4. Types of MHD SYSTEM5. Open Cycle MHD System6. Closed Cycle MHD System7. Diffrence between Open Cycle and
Closed Cycle MHD System8. Advantages OF MHD System9. Disadvantages of MHD System10. Applications11. Conclusion
Introduction
Magneto HydroDynamic (MHD) system is a non-
conventional source of energy which is based upon
Faraday’s Law of Electromagnetic Induction, which
states that energy is generated due to the movement of
an electric conductor inside a magnetic field.
Concept given by Michael Faraday in
1832 for the first time.
MHD System widely used in advanced
countries. Under construction in INDIA.
Need of MHDs
At present a plenty of energy is needed
to sustain industrial and agricultural
production, and the existing conventional
energy sources like coal, oil, uranium etc
are not adequate to meet the ever
increasing energy demands. Consequently,
efforts have been made for harnessing
energy from several non-conventional
energy sources like Magneto Hydro
Dynamics(MHD) System.
Principle Of MHD Power
GenerationFaraday’s law of electromagnetic induction : When an
electric conductor moves across a magnetic field, an emf is induced in it, which produces an electric current .
Lorentz Force on the charged particle (vector),
F = q(v × B) where,
v = velocity of the particle (vector)
q= charge of the particle (scalar)
B = magnetic field (vector)
Comparison between a Turbo
generator and a MHD generator
Types of
MHD SYSTEM
(1)Open cycle System
(2)Closed cycle System
(i)Seeded inert gas systems
(ii) Liquid metal systems
OPEN CYCLE MHD
SYSTEM
HYBRID MHD STEAM PART
OPEN CYCLE
CLOSED CYCLE MHD SYSTEM
DIFFERENCE BETWEEN OPEN
CYCLE AND CLOSED CYCLE
SYSTEM
Open Cycle System Working fluid after generating
electrical energy is
discharged to the
atmosphere through a stack
.
Operation of MHD generator
is done directly on combustion
products .
Temperature requirement :
2300˚C to 2700˚C.
More developed.
Closed Cycle
System
Working fluid is recycled to
the heat sources and thus is
used again.
Helium or argon(with cesium
seeding) is used as the
working fluid.
Temperature requirement :
about 530˚C.
Less developed.
NEED FOR FURTHER
RESEARCH
The MHD channel operates on extreme
conditions of temperature, magnetic and electric
fields .
So, numerous technological advancements are
needed prior to commercialization of MHD
systems .
Search is on for better insulator and electrode
materials which can with stand the electrical,
thermal, mechanical and thermo-chemical
stresses and corrosion.
ADVANTAGES OF MHD
SYSTEM
Conversion efficiency of about 50% .
Less fuel consumption.
Large amount of pollution free power generated .
Ability to reach full power level as soon as started.
Plant size is considerably smaller than conventional fossil fuel plants .
Less overall generation cost.
No moving parts, so more reliable .
DISADVANTAGES OF
MHD SYSTEM Suffers from reverse flow (short circuits) of
electrons through the conducting fluids around the ends of the magnetic field.
Needs very large magnets and this is a major expense.
High friction and heat transfer losses.
High operating temperature.
Coal used as fuel poses problem of molten ash which may short circuit the electrodes. Hence, oil or natural gas are much better fuels for MHDs. Restriction on use of fuel makes the operation more expensive.
APPLICATIONS
Power generation in space craft.
Hypersonic wind tunnel experiments.
Defense application.
CONCLUSION
The MHD power generation is in advanced stage today and closer to commercial utilization. Significant progress has been made in development of all critical components and sub system technologies. Coal burning MHD combined steam power plant promises significant economic and environmental advantages compared to other coal burning power generation technologies. It will not be long before the technological problem of MHD systems will be overcame and MHD system would transform itself from non- conventional to conventional energy sources.
THANK YOU !!