AC
DRIV
ESAC
DRIV
ES
Telephone: 704-588-3246 Fax: 704-588-3249
NEWNEW6500.3 to 150 Hpv/Hz and Sensorless Vector
EXTREMELY SIMPLE SET-UP AND OPERATION
PRE-PROGRAMMED APPLICATIONS
LOCAL OR REMOTE MOUNTABLE KEYPAD
EXCEPTIONALLY COMPACT DESIGN, DINMOUNTABLE TO 10HP
INTERNAL EMC COMPLIANT FILTERS
HIGH TORQUE SENSORLESS VECTOR OPTION
6
ConfigEd Lite PlusLets you…– Set up all parameters– Autotune your application– Chart key variables ON LINE!
…SIMPLE TO INSTALL …SIMPLE TO SET-UP …SIMPLE TO OPERATE
The 650 series inverters provide simple,no-fuss speed control of standard three-phase AC motors from 0.3 to 150 Hp.Sensorless vector versions (standardabove 10 Hp) provide exceptional dy-namic response. They are full of use-ful features including pre-programmedapplications - all designed to simplifyset-up, installation and operation.
With the 650 Series, you are in controlof your application immediately - nocomplicated set-up procedures,no confusing menu navigation;just quick and easy operationstraight from the box.
AC D
RIV
ESAC D
RIV
ES
Telephone: 704-588-3246 Fax: 704-588-3249
*Single-phase supply only.**Replace the 650 with 650V to select the sensorless vector option.
**Replace the 650 with 650V to select the sensorless vector option.
Remote mount keypad and Serial port standard on all 650V model drives (for frames 1, 2, and 3, select650V and replace the ‘S’ in the part number with a ‘R’ to select this option)
For example, change 650/0010/460/SBN to 650V/0010/460/RBN for a standard, 10 Hp, 650sensorless vector controller with a remote mountable keypad.
Brake Switch (optional above 15 Hp) (replace the ‘B’ in the part number with a ‘N’ to omit this option)For example, change 650V/0040/460/SBN to 650V/0040/460/SNN for a standard, 40 Hp, 650sensorless vector controller with a brake switch.
Internal EMC filter (up to 10 Hp) (replace the ‘N’ in the part number with a ‘F’ to select this option)For example, change 650/0010/460/SBN to 650V/0010/460/SBF for a 10 Hp, 650 sensorless vector con-troller with an internally mounted EMC filter.
For external footprint style EMC filters (15 to 150 Hp), see page 26.
7
Options
650**/00F3/230/SNN*650**/00F5/230/SNN*650**/00F7/230/SNN*650**/0001/230/SNN*650**/0002/230/SNN*650**/0003/230/SBN650**/0005/230/SBN650V/0007/230/1BN650V/0010/230/1BN650V/0015/230/1BN650V/0020/230/1BN650V/0025/230/1BN650V/0030/230/1BN650V/0040/230/CBN650V/0050/230/CBN650V/0060/230/CBN
0.25/0.30.3/0.5
0.55/0.750.75/11.5/22.2/34.0/5
5.5/7.5
11/1515/2018/2522/3030/4037/5045/60
1.52.2347
9.616.4222842546880104130
7.5/1011/1515/2018/25
-30/4037/5045/6055/75
28425468-
104130154192
Type Heavy DutyNominal Output
PowerKW/Hp
Current(A)
Standard DutyNominal Output
PowerKW/Hp
Built-inChoke
Built-inBrake Switch
FrameSize
1
2
3
––
C
E
D
F
DC
AC
Optional
220-240V Single and Three-Phase Controllers
YES
–
Current(A)
–
154
7.5/10
650**/00F5/460/SBN650**/00F7/460/SBN650**/0001/460/SBN650**/0002/460/SBN650**/0003/460/SBN650**/0005/460/SBN650**/0007/460/SBN650**/0010/460/SBN650V/0015/460/1BN
650V/0020C/460/1BN650V/0025/460/1BN650V/0030/460/1BN
650V/0040D/460/1BN650V/0050/460/1BN650V/0060/460/1BN650V/0075/460/CBN650V/0100/460/CBN650V/0125/460/CBN650V/0150/460/CBN
0.3/0.50.55/0.75
0.75/11.5/22.2/33.7/5
5.5/7.57.5/1011/1515/2018/2522/3030/4037/5045/6055/75
75/10090/12591/150
1.52
2.54.55.5912
21273845527387105125156180
15/2018/2522/3030/4037/5045/6055/7575/10090/12591/150
–
273445526587105125156180–
Type Heavy DutyNominal Output
PowerKW/Hp
Current(A)
Standard DutyNominal Output
PowerKW/Hp
Current(A)
Built-inChoke
Built-inBrake Switch
FrameSize
C
3
2
E
–
FAC
YES
Optional
380-460V Three-Phase Controllers
D
– –
DC
16
AC
DRIV
ESAC
DRIV
ES
Telephone: 704-588-3246 Fax: 704-588-32498
6500.3 to 150 Hp
STANDARDSThe 650 series meets European andNorth American standards wheninstalled in accordance with relevantproduct manual.
POWER SUPPLIESDigital I/O supply - 24 VDC (50 mA)Analog reference supply - 10 VDC (10 mA)
H
W
D
All dimensions in millimeters/inches.
FRAME 1,2 & 3 FRAME C & D FRAME E & F
STOPJOGREV DIRSTART
SPEEDREFERENCE
STAR
TRE
V D
IRJO
GST
OP
SPEEDREFERENCE
FRAME C-F
FRAME 1,2,3
DimensionsSize Weight
(Kg/Lbs)FrameSize
142/5.6
200/7.9
259/10.2
348/13.7
453/17.8
668/26.3
720/28.9
D
Mounting
H1 H2 W1
1
2
3
C
D
E
F
132/5.2
188/7.4
242/9.5
335/13.2 2
471/17.3
630/24.8 8
700/27.5
142/5.6
173/6.8
200/7.9
208/8.1
245/9.6
312/12.12
349/13.7
74/2.9
74/2.9
97/3.8
201/7.9
252/9.9
257/10.1
257/10.1
0.9/1.9
1.4/3.1
2.7/5.9
9.3/20
17.4/38
22.5/50
29/64
–
–
150/5.9
WH
TECHNICAL SPECIFICATIONPower Supply - Single phase units; 220-240 VAC ±10%;50-60 Hz ±5%Three phase units; 380-460 VAC ±10%; 50-60 Hz ±5%Ambient - 0-40°C (32-104°F); derate 2% per °C to 50°C
(122°F) maximumAltitude - 1000m (3280 ft.) ASL; derate 1% per 100m(328 ft.) above 1000m (3280 ft.) to 5000m (16400 ft.)max.Overload - 150% for 30 seconds (heavy duty)115% for 30 seconds (standard duty)Output Frequency - 0-240 HzEnvironmental Protection - IP20
Analog Inputs - 2; Speed control (0-10V, 4-20mA)Analog Output - 1; User configurable for DEMAND /CURRENT / PID ERROR / RAISE-LOWER OUTPUT (0-10V)Digital Inputs - 2; User configurable start/stop/direction/pre-set speeds (8)Digital Input/Outputs - 2; User configurable as inputs oroutputsDigital Relay Outputs - 1; User configurable relay out-puts (1A @ 240V)All digital outputs configurable for AT SPEED / AT ZERO
SPEED / RUNNING / HEALTHY / TRIPPED.Motor Thermistor Input
AC D
RIV
ESAC D
RIV
ES
Telephone: 704-588-3246 Fax: 704-588-3249 9
SIMPLE TO SETUP
Select from five internal programs to control your ap-plication or manually configure the drive as required.The programs configure the drive’s inputs, outputs and pa-rameter list automatically. The applications include:
SIMPLE TO USE– No languages to learn– Reduced menus show only key parameters– Software programmable with remote keypad option
SIMPLE TO OPERATE
The 6511 keypad is used for configuring and controlling thedrive. Its design includes a back-lit LCD, 4-digit readoutwith indicators for motor rotating and direction, local/remote operation, parameter type (diagnostic or setup),and units. The standard keypad is drive mounted andremovable.The remote keypad option lets the keypad mount up tothree meters from the drive. It also includes a P3 port thatcan be used to program the drive with CELite+ software.
– Basic Speed Control - voltage or current speed de-mand with digital start/stop and direction.
– Manual/Auto Control - switch between a local andremote speed demand signal.
– Preset Speeds - select up to 8 pre-programmed speedsusing digital inputs.
– Raise/Lower - increase and decrease speed from raiseand lower digital inputs.
– PID Control - control pressure, flow, temperature orother variable by monitor transducer feedback.
Parameter Type
Rotation
Start
Raise / Lower Speed Program Menu
Units
Local Remote
Stop