Seminar
Bisecting angle versus Paralleling Bisecting angle versus Paralleling techniquetechnique
INDIAN DENTAL ACADEMYLeader in continuing Dental Education
www.indiandentalacademy.com
Learning ObjectivesLearning Objectives
At the end of the session the learners should be able to-
Enumerate the basic principles of projection geometry.
Describe the bisecting angle and paralleling technique.
Describe advantages and disadvantages of bisecting angle and paralleling technique.
www.indiandentalacademy.com
Contents
Ideal positioning requirements Principles of projection geometry Comparison between paralleling and
bisecting angle technique Conclusion
www.indiandentalacademy.com
Ideal positioning requirement The tooth under the investigation and the film packet
should be in contact or, if not feasible, as close together as possible.
The tooth and film packet should be parallel to one another The film should be positioned with its long axis vetically for
incisors and canines, and horizontally for premolars and molars with sufficent film beyond the apices to record the apical tissues.
The X-ray tubehead should be positioned so that the beam meets the tooth and film at right angles in both horizontal and vertical planes.
The positioning should be reproducible.
www.indiandentalacademy.com
Radiographic techniques The anatomy of the oral cavity does not always
allows these ideal positioning requirements to be satisfied.
In an attempt to overcome the problems, two techniques for periapical radiography have been developed.
- The paralleling technique - The bisected angle technique
www.indiandentalacademy.com
PRINCIPLES OF PROJECTION GEOMETRY (SHADOW CASTING)
BASIC PRINCIPLES:- The focal spot (Source of radiation) should
be as small as possible.
www.indiandentalacademy.com
PRINCIPLES OF PROJECTION GEOMETRY (SHADOW CASTING)
The focal spot – Object distance should be as long as possible.
www.indiandentalacademy.com
PRINCIPLES OF PROJECTION GEOMETRY (SHADOW CASTING)
The Object – Film distance should be as small as possible.
www.indiandentalacademy.com
PRINCIPLES OF PROJECTION GEOMETRY (SHADOW CASTING)
The long axis of the object & the film planes should be parallel.
www.indiandentalacademy.com
PRINCIPLES OF PROJECTION GEOMETRY (SHADOW CASTING)
The X-Ray beam should strike the object & the film planes at right angles.
www.indiandentalacademy.com
There should be no movement of the tube, film or patient during exposure.(Given by Mason & Lincoln)
PRINCIPLE OF PROJECTION GEOMETRY (SHADOW CASTING)
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUESynonyms - Short cone
technique Finger holding
technique
Synonyms - Long cone
technique. Right angle
technique. Extension
paralleling technique
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Based on geometric
principle CIESZYNSKI’S Rule of isometry - Two triangles are equal if they have two equal angles and share a common side.
Based on the fact that x-ray film is supported parallel to the long axis of the tooth being radiographed.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Central ray is
perpendicular to imaginary bisector of angle formed by film & long axis of tooth.
Central ray of the x-ray beam is directed at right angles to both the tooth and the film.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE
Satisfies Rule 1 & 3 of shadow casting.
Size 2 film preferred.
Satisfies Rule 1, 2, 4 & 5 of shadow casting.
Size 1 film preferred anteriors and size 2 film for posteriors.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Target -Film Distance is 6” – 8”
Target – FilmDistance is 16” – 18”
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Use of film holder
is not mandatory Rinn BAI Stable bite block Snap-A-Ray
Use of film holder is mandatory Rinn XCP Precision film
holders Grip film holder Hemostat with bite
block
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE
Film touches tooth at crown portion. Thus, the crown film distance is less than apex film distance.
Film is parallel & away from tooth.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Requires less
exposure Hence kvP is
reduced Divergent rays
used for image formation.
Requires more exposure
Hence kvP is increased
Parallel rays used for image formation.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE
Film placement easier.
Film placement difficult, so discomfort to the patient.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE
Patient can hold the film.
Patient cannot hold the film. Film holder mandatory.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Film holders not
routinely used so vertical and horizontal angulations have to be adjusted.
Use of film holder with a beam alignment device eliminates the need to device vertical and horizontal angulations so distortions eliminated.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Film holders not
used routinely. So chances are less for impingement and causing discomfort.
Film holders used may impinge on oral tissue causing discomfort & gagging to the patient.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE
Distortion of the image.
Image is more or less anatomically accurate.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Increased
elongation or foreshortening of image.
Image has same size & shape as that of object.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Distortion of image
due to oblique exposure & bending of film due to incorrect digital pressure.
Film holders prevent such errors producing anatomically accurate image.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE
Incorrect horizontal angulations may lead to overlapping of the crowns and roots.
Less chances of incorrect horizontal angulations.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE More vertical
angulation. Less vertical
angulation.So maximum chances of overlapping of buccal and lingual cusps.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Less tooth area
underneath the restoration is relevant due to more vertical angulation.
More tooth area underneath the restoration is relevant due to less vertical angulation.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Difficult to visualize
the imaginary bisector and determine the vertical angulation and direct the central ray.
Central rays perpendicular to both film and long axis of tooth.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Superimposition of
the shadow of the zygomatic arch on the teeth
Less vertical angulation causes minimum superimposition of zygomatic buttress of maxilla over the upper roots. Teeth apices & maxillary sinus better seen.
www.indiandentalacademy.com
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Cone cut results
particularly if rectangular collimation used.
PID aims the X-ray beam accurately so there is no coning off or cone cutting.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Shadows of the
alveolar bone tend to fill the interproximal spaces. The loss of bone or pathology is misinterpreted.
Alveolar crest seen in true relationship to the teeth.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE More effective
when palatal vault is deep or shallow, bony overgrowth or children with underdeveloped jaws.
Difficult in shallow palatal vault, small mouth, children, handicapped patients.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Film holders not
used making it comparatively easier to carry Endodontic work.
Use of film holder with a beam alignment device makes it difficult to carry Endodontic work.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Sterilization of
holders not required as they are not used usually.
Unnecessary exposure because patient touches film.
Sterilization must. Holders need to be autoclaved or disposable holders (Styrofoam bite blocks) to be used.
Film holders are used - so no unnecessary exposure.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Vertical
angulations may expose vital organs such as thyroid gland and the lens of the eye.
Lack of extreme vertical angulations cause less exposure to critical organs.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Shifting may lead to
improper centering of the film- cone cutting and/or blurring.
Position indicating device used, so shifting of patients head may not affect much.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Duplication of
technique is difficult.
Hence, comparison in serial radiographs not possible.
Technique is easy to standardize & can be accurately duplicated.
Hence serial radiography is possible.
www.indiandentalacademy.com
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Positioning of the
film in third molar region comparatively easy
Positioning the film in the third molar region very difficult.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Economic
Requires less time
Comparatively expensive because of need of higher KVP machine and film holders.
Requires more time
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Requires less
space. Adjustments can
be made easily.
Does not have any anatomical constraints.
Requires more space.
Adjustments cannot be made so easily.
Have anatomical constraints.
www.indiandentalacademy.com
BISECTING ANGLE PARALLELINGTECHNIQUE TECHNIQUE Can be used when
tooth is longer than film.
More factors to be standardized.
Is difficult to use when the patient is in supine position.
Cannot be used when tooth is longer than film.
Less factors to be standardized.
Not difficult as PID’s are used.
www.indiandentalacademy.com
Conclusion The diagnostic advantages of the accurate,
reproducible images produced by paralleling technique using film holders and beam-aiming device should be regarded technique of choice for periapical radiography.
Periapical radiography is not always as straightforward in practice as it appears in theory.
Although paralleling technique should be regarded as the technique of choice, it is not always possible.
www.indiandentalacademy.com
However, a knowledge of the theoretical requirements of imaging enables the clinician to modify the available techniques to suit individual needs of patients.
www.indiandentalacademy.com
ReferencesReferences
Oral Radiology – White & Pharoah Dental Radiography- Haring Jansen Textbook of Dental & Maxillofacial Radiology – Freny R.Karjodkar Essentials of Dental Radiography & Radiology
third edition – Eric Whaites,